G3/8" DIN ISO 228 THREAD SHOULDER AND DUST CAP MATING SURFACE. STYLE H ESCUTCHEON (SEPARATELY ORDERED) 85 mm DIA. (3-3/8")

Similar documents
RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

RAVEN 5.6K Institutional Sprinklers Pendent and Horizontal Sidewall Quick Response, Standard and Extended Coverage General Description

Sprinkler Identification Number. Page 1 of 6 AUGUST 2018 TFP288. Worldwide Contacts.

FIGURE 1 MODEL RFIII ECLH CONCEALED HSW SPRINKLER ASSEMBLY AND FEATURES. 5/16" (7,9 mm) MIN. 9/16" (14,3 mm) MAX.

WRENCH FLATS NPT 1/2" 7/16" (11,1 mm) NOMINAL MAKE-IN. 1-1/2" (38,1 mm) 2-3/16" (55,6 mm) WRENCH NPT. (12,7 mm) NOMINAL MAKE-IN.

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

WRENCH FLATS 1/2" NPT. 7/16" (11,1 mm) NOMINAL MAKE-IN CENTERLINE OF WATERWAY ESCUTCHEON PLATE SEATING SURFACE

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

special request FACTORY ASSEMBLED UPRIGHT WITH SCREW FIELD ASSEMBLED MODEL S2 SHIELD (SEE INSTALLATION SECTION) WRENCH FLATS *

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Horizontal Sidewall Wet Pipe and Dry Pipe Systems General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright and Pendent Extended Coverage Light and Ordinary Hazard General Description

Series TY-FRB 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Quick Response, Standard Coverage General Description

Sprinkler Identification Numbers. TY3351 Horizontal TY3451 Vertical. Technical Data

Page 1 of 8 DECEMBER 2018 TFP408. Worldwide Contacts.

ESCUTCHEON PLATE SEATING SURFACE. 1-11/16" (42,7 mm) CROSS SECTION

proven to help in the control of residential fires and to improve the chance for occupants to escape or be evacuated. Dry Pipe System Application

* Temperature rating is FIGURE K-FACTOR QUICK RESPONSE SERIES TY-FRB HORIZONTAL SIDEWALL (TY3331) SPRINKLERS

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General Description

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage

Series TY-FRB 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series EC K-factor Extended Coverage (Light Hazard) Pendent and Recessed Pendent Sprinklers General Description

RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe and Dry Pipe Systems General Description

Model TY-FRFS, TY-FS Special, and TY-FS 57, 80, and 115 K-factor Upright and Pendent Flat Spray Sprinklers General Description

Sprinkler Identification Numbers

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Sprinkler Identification Numbers

ESCUTCHEON PLATE SEATING 3/4" NPT SURFACE. 1-1/2" (38,1 mm) CROSS SECTION PENDENT RECESSED PENDENT

RAPID RESPONSE Series LFII Residential Sprinklers 5.8 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

Series TY-B 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage General Description

RAPID RESPONSE Series LFII Residential Sprinklers 5.6 K-factor Horizontal Sidewall, NFPA 13 Optimized Wet Pipe Systems

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Recessed Pendent, Dry Type Wet Pipe and Dry Pipe Systems General Description

O-RING UPRIGHT SHIELD WRENCH FLATS WRENCH FLATS FIGURE 1 SERIES TY-B UPRIGHT (TY3153) AND PENDENT (TY3251) SPRINKLERS

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Model TY-FRFS, TY-FS Special, and TY-FS Flat Spray Sprinklers, Upright and Pendent 57, 80, and 115 K-factor General Description

Model SW-20 and SW K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response)

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Domed-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

Sprinkler Identification Number (SIN)

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard) General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Horizontal Sidewall Wet Pipe Systems

Model ELOC 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick and Standard Response, Extended Coverage

Series TY-B 5.6 and 8.0 K-factor Upright and Pendent Intermediate Level Sprinklers Standard Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.9 K-factor Flat-Plate Concealed Pendent Wet Pipe and Dry Pipe Systems General Description

ILLUSION 11.2 K-factor Extra Large Orifice Concealed Pendent Sprinklers Quick Response, Standard Coverage General Description

Series RFII 5.6 K-factor. Flush II Concealed Pendent Sprinklers

RAPID RESPONSE Series LFII Residential Sprinkler 4.4 K-factor Horizontal Sidewall, Dry Type Wet Pipe System General Description

Submittal Packages Detailed with Items and Reviewers

Series DS-1 Dry-Type Sprinklers 5.6K Pendent, Upright, and Horizontal Sidewall Quick Response, Standard Coverage General Description

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

The Series LFII (TY3596) Residential

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

Model ESFR K-factor Dry Type Pendent Sprinklers Early Suppression, Fast Response General Description

RAPID RESPONSE Series LFII Residential Sprinklers 4.2 K-factor Flush Pendent Wet Pipe and Dry Pipe Systems General Description

Model ESFR-17 Dry Type Pendent Sprinklers Early Suppression Fast Response 16.8 K-factor General Description

Series EC-11 and EC-14 Sprinklers, 11.2 K and 14.0 K Upright, and Pendent Extended Coverage Light and Ordinary Hazard General Description

Model CHEC 8.0 K-factor Concealed Horizontal Extended Coverage Quick Response Light Hazard, Sidewall Sprinklers General Description

Series ELO K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage General Description

Model/Sprinkler Identification Number JULY, 2011 WARNINGS

Sprinkler Identification Number (SIN) TY4234. Page 1 of 8 APRIL 2012 TFP Technical Services

Sprinkler Identification Number TY ECLH HSW, 8.0K, 3/4"NPT

Series LFII Residential Sprinklers Flat-Plate Concealed Pendent 4.9 K-Factor General Description

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Series TY-FRL 5.6 and 8.0 K-factor Extended Coverage Horizontal Sidewall Sprinklers Quick & Standard Response (Light Hazard)

Series ELO-231B 11.2 K-factor Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Sprinkler Identification Numbers

Model/Sprinkler Identification Numbers

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-Factor General Description

Model WS TM 5.6 K-factor Specific Application Window Sprinklers, Horizontal and Pendent Vertical Sidewall General Description

Worldwide Contacts.

5.6K Horizontal Sidewall Standard and Quick Response, Extended Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

Series LFII Residential Pendent Sprinklers 4.9 K-factor General Description

Series LFII Residential Flush Pendent Sprinklers 4.2 K-factor General Description

Series DS-1 Stainless Steel Dry-Type Sprinklers 5.6K Pendent, HSW, and Extended Coverage HSW Standard and Quick Response General Description

SENJU SPRINKLER CO., LTD.

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Standard Coverage, Model: RC-QR, K-Factor: 5.6, SIN: SS9561

Series ELO-231 Upright and Pendent Sprinklers. Standard Response, Standard Coverage, General Description

Series LFII Residential Horizontal Sidewall Sprinklers 4.4 K-factor General Description

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Models BB, SD, HIP, and AP Specific Application Sprinklers For Protecting Attics General Description

11.2K * Pendent Extended Coverage, Light and Ordinary Hazard General Description. Model/Sprinkler Identification Numbers (SINs) Technical Data

In the event of this condition, consult the Authorities Having Jurisdiction for guidance and approval.

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

Commercial Flat Concealed Sprinkler, Pendent, Quick & Standard Response, Standard Coverage, Model: CN-QR, K-Factor: 5.

5.6K Pendent, Upright, and Horizontal Sidewall Standard Response, Standard Coverage General Description. Model/Sprinkler Identification Numbers (SINs)

INSTITUTIONAL QUICK RESPONSE FLUSH HORIZONTAL SIDEWALL SPRINKLER VK412 (K5.6) TECHNICAL DATA

INSTITUTIONAL QUICK RESPONSE/QREC FLUSH PENDENT SPRINKLER VK410 (K5.6) TECHNICAL DATA

SENJU SPRINKLER CO.,LTD. Residential Flush Pendent Sprinkler Model ZN-RES,K=4.2 (SIN / SS4421) (PTFE gasketed orifice seal design) General Description

Residential Flush Horizontal Side-Wall Sprinkler Model HF-RES,K=4.2 (SIN / SS4423) (PTFE gasketed orifice seal design)

Data Sheet 4.19 Issue C

Model/Sprinkler Identification Number (SIN) Technical Data

Series LFII Residential Horizontal Sidewall Sprinklers 4.2 K-factor General Description

UL LISTED. SPRINKLER HEADS IN STOCK: Pendent Upright Horizontal sidewall Concealed. RESPONSE Quick response Standard response

Transcription:

Worldwide Contacts www.tyco-fire.com Model FSC 80 K-factor Flush Sprinkler, Pendent Quick Response, Standard Coverage General Description The TYCO Model FSC 80 K-factor Flush Sprinkler is a quick response standard coverage sprinkler designed for use in areas such as offices, hospitals, churches, schools, apartments, and hotels. For applications in poured concrete ceiling/floor assemblies, a unique Installation Cup is used to form the recessed cavity into which the FSC Sprinkler is installed. For suspended ceiling applications, a Dust Cap is used to protect the FSC Sprinkler above the ceiling panel. The flush design is made aesthetically appealing by concealing the deflector and other operating parts above the link assembly. The FSC Sprinkler, with a heat sensitive solder type release element, is rated as a quick response sprinkler. The TYCO Model FSC 80 K-factor Flush Sprinkler described herein must be installed and maintained in compliance with this document and with the applicable standards CEA 4001 Sprinkler Systems: Planning and Installation or EN12845 Fixed Firefighting Systems - Automatic Sprinkler Systems - Design, Installation and Maintenance, in addition to the standards of any authorities having jurisdiction. Failure to do so IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the INSTALLER WARNING that provides cautions with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. may impair the performance of these devices. Johnson Controls specifically disclaims any liability for damages or injury (including death) arising out of or caused by manipulation, dismantling, or misuse of the FSC Sprinkler or the use or attempted use of the FSC Sprinkler or any component thereof as an instrument unrelated to its intended function as a fire protection device. The owner is responsible for maintaining their fire protection system and devices in proper operating condition. Contact the installing contractor or product manufacturer with any questions. Sprinkler Identification Number (SIN) TY3200 Technical Data Approvals VdS Approved Model FSC Flush Sprinkler is VdS approved for installation per CEA 4001 Sprinkler Systems: Planning and Installation or EN12845 Fixed Firefighting Systems - Automatic Sprinkler Systems - Design, Installation and Maintenance Maximum Working Pressure 12,1 bar (175 psi) Discharge Coefficient 80,6 LPM/bar ½ (K=5.6 GPM/psi ½) Temperature Rating 74 C (165 F) Finishes Sprinkler: White/Gray Escutcheon: White/Gray Physical Characteristics Frame.............................Brass Deflector Assembly..................Bronze Sealing Assembly..Beryllium Nickel w/teflon Link Assembly..................... Copper Button.............................Brass Deflector Guide Pins Stainless Steel Bridge... Stainless Steel Levers... Stainless Steel Plug.............................. Plastic Escutcheon......................... Steel Installation Cup..................... Plastic Installation Cup Insert................Plastic Thread Extension....................Brass Thread Adapter......................Brass Dust Cap.......................... Plastic Design Criteria General Criteria The TYCO Model FSC 80 K-factor Flush Sprinkler is intended to be installed per CEA 4001 Sprinkler Systems: Planning and Installation or EN12845 Fixed Firefighting Systems - Automatic Sprinkler Systems - Design, Installation and Maintenance where Flush Sprinklers are permitted. Only escutcheons shown in Figure 1 can be utilized with the FSC Sprinkler. In all cases, CEA 4001 Sprinkler Systems: Planning and Installation or EN12845 Fixed Firefighting Systems - Automatic Sprinkler Systems - Design, Installation and Maintenance must be followed to ensure proper installation. The FSC Sprinkler can be used in numerous scenarios including installation in concrete ceilings/floors assemblies and suspended ceilings. Page 1 of 8 AUGUST 2018 TFP645

Page 2 of 8 51 mm (2") DEFLECTOR GUIDE PIN BODY G3/8" SHOULDER AND DUST CAP MATING SURFACE SEE FIGURES 4 AND 7 FOR SEPARATELY ORDERED INSTALLATION COMPONENTS MOUNTING SURFACE LINK ASSEMBLY SIDE VIEW 3 mm (1/8") WRENCHING NOTCHES ORIENTATION DOT * STYLE H (SEPARATELY ORDERED) 85 mm DIA. (3-3/8") OPERATED SIDE VIEW (WITH SEPARATELY ORDERED ) DEFLECTOR ASSEMBLY IN OPERATED POSITION 16 mm (5/8") 35 mm DIA. (1-3/8") BOTTOM VIEW INNER LINK OUTER LINK * * USE ONLY ORIENTATION DOT, LOCATED ON OUTER LINK ADJACENT TO WRENCHING NOTCH AND PERPENDICULAR TO DEFLECTOR GUIDE PINS, AS VISUAL INDICATION OF RELATIVE DEFLECTOR ORIENTATION AFTER INSTALLATION. POSITION OF INNER LINK TO ORIENTATION DOT MAY VARY; DO NOT USE INNER LINK AS REFERENCE TO VERIFY DEFLECTOR ORIENTATION AFTER INSTALLATION OR DURING SUBSEQUENT INSPECTION. FIGURE 1 MODEL FSC FLUSH ASSEMBLY WRENCHING NOTCH DEFLECTOR GUIDE PIN WRENCH SLOTS ENGAGE INTERNAL INSTALLATION CUP RIBS WRENCH PRONGS UNIQUELY SPACED TO ENGAGE WRENCHING NOTCHES WRENCH FLAT PARALLEL TO GUIDE PINS WHEN WRENCH ENGAGES (FLAT INDICATES RELATIVE ORIENTATION OF DEFLECTOR AND ORIENTATION DOT) HEX ACCEPTS 27 mm WRENCH SOCKET ACCEPTS 1/2" DRIVE FIGURE 3 W-TYPE 28 INSTALLATION CUP REMOVAL WRENCH SOCKET ACCEPTS 1/2" DRIVE FIGURE 2 W-TYPE 25 INSTALLATION WRENCH

Page 3 of 8 MALE G3/4" ALL PIPE S STRAIGHT PLUGS FITTING AT SYSTEM PRESSURE TEST O-RING RIBS EMBEDDED FITTING (G3/4" OUTLET) ADAPTER MODEL FSC EMBEDDED SYSTEM PIPE FORMED CAVITY IN CONCRETE STRUCTURE INSTALLATION CUP WITH O-RING CUP DETENT GROOVES INSERT CAVITY DETENT DIMPLES FASTENER HOLES 6,4 mm (1/4") 70 mm (2-3/4") DIA. (REF.) 85 mm DIA. (3-3/8") EXPOSED CONCRETE CEILING FIGURE 5 MODEL FSC FLUSH EXPOSED CONCRETE CEILING INSTALLATION MALE G3/4" MALE G1/2" INSTALLATION CUP INSERT ADAPTER FEMALE G1/2" FEMALE G3/8" SHOULDER RECESS EMBEDDED FITTING (G3/4" OUTLET) ADAPTER MODEL FSC EMBEDDED SYSTEM PIPE FORMED CAVITY IN CONCRETE STRUCTURE FIGURE 4 MODEL FSC FLUSH CONCRETE CEILING INSTALLATION COMPONENTS 6,4 mm (1/4") 70 mm (2-3/4") DIA. (REF.) 85 mm DIA. (3-3/8") CEILING FINISH FIGURE 6 MODEL FSC FLUSH FINISHED CONCRETE CEILING INSTALLATION 15 mm (19/32") MAXIMUM

Page 4 of 8 Installation Poured Concrete Ceiling/Floor Application For poured concrete ceiling/floor applications, TYCO Model FSC 80 K-factor Flush Sprinklers must be installed in accordance with Steps 1 through 12 of this procedure: Step 1 Step 2 Step 3 Step 1. Center Cup Insert at intended sprinkler location and fasten to concrete form with either nails or screws. Step 2. Ensure O-ring is properly fitted beneath threads on neck of installation cup. Screw Installation Cup into sprinkler fitting ensuring top of installation cup is flush against face of sprinkler fitting. Step 3. Align Installation Cup with Cup Insert and press against concrete form. Ensure Installation Cup snaps into place, fully engaging Cup Insert, and is flush against concrete form. Step 4 Step 5 Step 6 Step 4. Connect pipe to sprinkler fitting per manufacturer s recommendations. Repeat steps 1 through 4 for remaining sprinkler locations in system. Perform system pressure test only after pipes have been properly connected to all sprinkler fittings. Note: Installation Cup serves as sprinkler fitting plug during system pressure test. Step 5. After required pressure test has been successfully performed, pour concrete ceiling/floor. Ensure concrete is distributed evenly around installation cup, sprinkler fitting and pipe. CAUTION Use extreme caution when distributing concrete around pipe so as not to nick or split pipe. Failure to do so may result in equipment damage and/or system failure. Step 6. After concrete has cured, remove concrete form with attached Cup Insert.

Page 5 of 8 Step 7 Step 8 Step 9 Step 7. Insert W-Type 28 Wrench (Ref. Figure 3) into installation cup cavity, fully seating and engaging internal cup ribs. Applying 27 mm hex wrench or 1/2 inch drive, unscrew Installation Cup from sprinkler fitting. Ensure O-ring is removed with Installation Cup from sprinkler fitting outlet and sprinkler cavity. Note: Apply ceiling finish or coating before proceeding to sprinkler installation in remaining steps. Step 8. Apply sealant (not included with sprinkler kit) to external threads of adapter. Hand-tighten Adapter into sprinkler fitting. Ensure adapter shoulder is flush against face of fitting. internal threads of adapter. Failure to do so may prevent proper assembly of remaining components. Step 9. Apply sealant to external threads of sprinkler inlet. With hex end of thread extension oriented toward sprinkler inlet, hand-tighten onto sprinkler threads until recess is seated on sprinkler thread shoulder. sprinkler guide pins and internal waterway of sprinkler inlet. Failure to do so may result in equipment failure. Step 10 Step 11 Step 12 Step 10. Assemble Escutcheon onto sprinkler body. Ensure Escutcheon is flush against sprinkler body mating surface. Apply sealant to external threads of thread extension. sprinkler guide pins and internal waterway of thread extension. Failure to do so may result in equipment failure. Step 11. Engage Sprinkler by W-Type 25 Wrench (Ref. Figure 2). Hand-tighten (19 N m [14 lb-ft] Maximum) assembly into Adapter. Ensure Escutcheon is flush against ceiling mounting surface and Sprinkler is oriented as intended (refer to Figures 1 and 2 for orientation details). Note: W-Type 25 Wrench engages Sprinkler in only one way. When Sprinkler is engaged by Wrench, flat on Wrench is parallel to sprinkler deflector guide pins, indicating during installation relative sprinkler deflector orientation. Step 12. Remove W-Type 25 Wrench.

Page 6 of 8 Installation Suspended Ceiling Application For suspended ceiling applications, TYCO Model FSC 80 K-factor Flush Sprinklers must be installed in accordance with Steps A through F of this procedure: Step A Step B Step C Step A. With reference to dimensions provided in Figure 8, install sprinkler fitting at proper distance above finished suspended ceiling level and cut clearance hole centered on sprinkler fitting through ceiling panel. Note: Ensure ceiling panel is properly installed before proceeding to sprinkler installation in remaining steps. Step B. Assemble Dust Cap onto Sprinkler. Ensure Dust Cap is flush against sprinkler body mating surface. Step C. Apply sealant to external threads of sprinkler inlet. With hex end of thread extension oriented toward sprinkler inlet, hand-tighten onto sprinkler threads. sprinkler guide pins and internal waterway of sprinkler inlet. Failure to do so may result in equipment failure. Step D Step E Step F Step D. Assemble Escutcheon onto sprinkler body. Ensure Escutcheon is flush against sprinkler body mating surface. Apply sealant to external threads of thread extension. sprinkler guide pins and internal waterway of thread extension. Failure to do so may result in equipment failure. Step E. Engage Sprinkler by W-Type 25 Wrench (Ref. Figure 2). Hand-tighten (19 N m [14 ft- lb] Maximum) assembly into sprinkler fitting. Ensure Escutcheon is flush against ceiling mounting surface and Sprinkler is oriented as intended (refer to Figures 1 and 2 for orientation details). Note: W-Type 25 Wrench engages Sprinkler in only one way. When Sprinkler is engaged by Wrench, flat on Wrench is parallel to sprinkler deflector guide pins, indicating during installation relative sprinkler deflector orientation. Step F. Remove W-Type 25 Wrench.

Page 7 of 8 ALL PIPE S STRAIGHT FITTING (G1/2" OUTLET) MALE G1/2" FEMALE G3/8" SHOULDER RECESS SHOULDER CLEARANCE HOLE DUST CAP MODEL FSC CEILING PANEL 70 mm (2-3/4") DIA. 40 mm (1-1/2") DIA. 85 mm DIA. (3-3/8") FACE OF FITTING FIGURE 8 MODEL FSC FLUSH SUSPENDED CEILING INSTALLATION MOUNTING SURFACE 50 mm (2") 6,4 mm (1/4") DEFLECTOR GUIDE PIN CAVITY DUST CAP FIGURE 7 MODEL FSC FLUSH SUSPENDED CEILING INSTALLATION COMPONENTS Care and Maintenance TYCO Model FSC 80 K-factor Flush Sprinklers must be maintained and serviced in accordance with this section: Service inspections should be made on a regular basis to detect possible damage or alterations to the sprinkler and escutcheon. Inspections should include making certain that the escutcheon is held fast to the mounting surface. Damaged or altered sprinklers are to be replaced immediately to avoid personal injury and to prevent use for causing personal injury, as well as to maintain the sprinkler system in an operative condition. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprinklers damaged by dropping, striking, wrench twist/slippage, or the like, must be replaced. Frequent visual inspections are recommended to be initially performed for sprinklers installed in potentially corrosive atmospheres to verify the integrity of the materials of construction as they may be affected by the corrosive conditions present for a given installation. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the approval agency and standards of any other authority having jurisdiction. Contact the installing contractor or product manufacturer with any questions. Sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes.

Page 8 of 8 Limited Warranty For warranty terms and conditions,visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for availability. When placing an order, indicate the full product description and Part Number (P/N). Sprinkler Assemblies, Concrete Ceiling Application Specify: Model FSC 80 K-factor Flush Sprinkler, Quick Response, Standard Coverage, 74 C (165 F), with (specify) finish, with Thread Extension and Adapter, P/N (specify): White...50-313-4-165 Gray...50-313-9-165 Sprinkler Assemblies, Suspended Ceiling Application Specify: Model FSC 80 K-factor Flush Sprinkler, Quick Response, Standard Coverage, 74 C (165 F), with (specify) finish, P/N (specify): White...51-313-4-165 Gray...51-313-9-165 Style H Escutcheons (85 mm Diameter) White...56-313-4-010 Gray...56-313-9-010 Concrete Ceiling Application Installation Components Concrete Ceiling Installation Kit (Includes: Installation Cup, O-ring, Cup Insert)............................ 91-313-1-110 Installation Cup with O-ring...... 91-313-1-100 Cup Insert...91-313-1-004 Thread Extension.............. 91-313-1-008 Adapter....91-313-1-007 Suspended Ceiling Application Installation Components Dust Cap...91-316-1-010 Thread Extension.............. 91-313-1-008 Thread Extension and Adapter Thread Extension...............91-313-1-008 Adapter....91-313-1-007 Sprinkler Wrench Specify: W-Type 25 Sprinkler Installation Wrench, P/N 56-314-1-001 Installation Cup Wrench Specify: W-Type 28 Installation Cup Removal Wrench, P/N 56-000-4-301 1400 Pennbrook Parkway, Lansdale, PA 19446 Telephone +1-215-362-0700 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TEFLON is a registered trademark of DuPont