Rope Switches Models that comply with cable break/slack detection with manual reset for Emergency Stop applications Available spans range from 6 to 1 m Trip and latch switch models are available Mimum switch life is 1-million operations Heavy-duty switch housgs withstand harsh environments and outdoor use Switch activates if the rope is pulled, becomes loose or breaks Design meets positive openg requirements for rope pull switches (IEC 6947-5-1) RP-RM83 and RP-LS42 comply with ANSI NFPA 79, ANSI B.19, IEC 624-1, EN 1385 and EN ISO 6947-5-5 for Emergency Stop applications RP-QM72/QMT72, RP-LM4 and RP-QM9 comply with ANSI NFPA 79 and IEC 624-1 for Stop Control applications Photoelectrics Fiber Optic Measurement & Inspection Special Purpose Vision Lightg & Indicators Wireless Light Screens Laser Scanners Controllers & Modules Two-Hand Control Modules Interlock Switches Emergency Stop & Stop Control RP-RM83 page 642 Cable break/slack detection with manual reset Manual reset () design Heavy-duty housg to withstand harsh environments and outdoor use; IP67 rated Rope span up to 75 meters E-stop button with manual reset dicators Additional solid-state auxiliary output for remote tension monitorg Extra contacts for switch monitorg 9 wide at base Rugged metal housg with protective earth termal (IEC 6947-1) RP-LS42 page 643 Cable break/slack detection with manual reset Manual reset () design Rope span up to 75 meters Model with E-stop button for manual reset Quick rope fixg and tensiong dicator Extra contacts for switch monitorg 42 wide at base Insulated device (IEC 6947-5-1) RP-QM72/QMT72 page 644 Manual reset () design Rope span up to 6, or 2 meters Indicator Models with additional contacts for monitorg or dual channel hookup 82 wide at base Rugged metal housg with protective earth termal (IEC 6947-1) Cable break/slack detection (note: does not comply with manual reset requirement per EN IEC 6947-5-5 for Emergency Stop applications.) E-STOP BUTTONS ROPE PULLS ENABLING DEVICES RP-LM4 page 645 Manual reset () and Auto Reset (Trip) models Rope span up to 6 meters Indicator Limit-switch style housg (EN 541) 4 wide at base Rugged metal housg with protective earth termal (IEC 6947-1) Cable break/slack detection (note: does not comply with manual reset requirement per EN IEC 6947-5-5 for Emergency Stop applications.) RP-QM9 page 645 Manual reset () design Rope span up to 1 meters, with switch center Manual reset Extra contacts for switch monitorg 9 wide at base Rugged metal housg with protective earth termal (IEC 6947-1) Cable break/slack detection (note: does not comply with manual reset requirement per EN IEC 6947-5-5 for Emergency Stop applications.) Call for more formation 1.888.373.6767 641
E-STOP BUTTONS ROPE PULL SWITCHES ENABLING DEVICES RP-RM83 Series 7. 185. 85.5 85.5 onle AUTOCAD, STEP, IGES & PDF 53. 9. 53. 9. ACCESSORIES PAGE 647 RP-RM83F-75LT.. and RP-RM83F8LT.. Models RP-RM83F-75LR.. and RP-RM83F8LR.. Models Components for wire rope assembly kits (page 647) RP-RM83 Series E-Stop and Stop Control Device Actuation Contacts* Contacts Action/ Contact State* Aux. Status Output Length 75 m Model Length 38 m Contact Config. & Switch Diagram (Rope ed) 2 NO Yes RP-RM83F-75LTE RP-RM83F8LTE Yes RP-RM83F-75LRE RP-RM83F8LRE RP-RM83F-75LT RP-RM83F8LT RP-RM83F-75LR RP-RM83F8LR SD1 & SD2 (p. 648) SD3 & SD4 (p. 648) Cable ed Cable NC = Normally Contact, NO = Normally Contact * RP-RM83 rope pulls comply with IEC 6947-5-1 Positive g requirements. See data sheet or and s for more formation/clarification. 642 More formation onle at bannerengeerg.com
RP-LS42 Series onle AUTOCAD, STEP, IGES & PDF Components for wire rope assembly kits (page 647) Photoelectrics Fiber Optic Measurement & Inspection Special Purpose Vision Lightg & Indicators Wireless 294. 294. Light Screens Laser Scanners 4. 4. 4. 4. Controllers & Modules Two-Hand Control Modules Interlock Switches Emergency Stop & Stop Control ACCESSORIES PAGE 647 45. RP-LS42 Series E-Stop and Stop Control Device Actuation RP-LS42F-..L Model Length 42. Contacts* 45. 42. RP-LS42F-..LF Model Contact 45. Action/ Contact State* 42. RP-LS42F-..LE Model (with E-Stop Button) Model Contact Config. & Switch Diagram E-STOP BUTTONS ROPE PULLS RP-RM83 RP-LS42 RP-QM72/QMT72 RP-LM4 RP-QM9 ENABLING DEVICES RP-LS42F-25L 25 m 2 NO RP-LS42F-25LE RP-LS42F-25LF SD7 RP-LS42F8L (Rope ed) 37.5 m 2 NO RP-LS42F8LE RP-LS42F8LF SD6 (p. 648) RP-LS42F-75L 75 m 2 NO RP-LS42F-75LE RP-LS42F-75LF SD5 (p. 648) Cable ed Cable NC = Normally Contact, NO = Normally Contact * RP-LS42 rope pulls comply with IEC 6947-5-1 Positive g requirements. See data sheet or and s for more formation/clarification. Call for more formation 1.888.373.6767 643
E-STOP BUTTONS ROPE PULL SWITCHES ENABLING DEVICES RP-QM72/QMT72 Series 69. 181.5 RP-QMT72 Models 82. onle AUTOCAD, STEP, IGES & PDF RP-QM72 Models 142. Components for wire rope assembly kits (page 647) ACCESSORIES PAGE 647 RP-QM72/QMT72 Series Stop Control Device Actuation Length Contacts* Contact Action/ Contact State* Model Contact Config. & Switch Diagram 6 m RP-QM72D-6L SD8 (Rope ed) open closed m RP-QM72D-L closed open 2 m RP-QMT72D-2L m 4 NC open open RP-QMT72F-L SD9 SD1 SD m 1 NO open RP-QMT72E-L SD closed open open Cable ed Cable NC = Normally Contact * RP-QM72/QMT72 rope pulls comply with IEC 6947-5-1 Positive g requirements. See data sheet or and s for more formation/clarification. 644 More formation onle at bannerengeerg.com
RP-LM4 Series Photoelectrics Fiber Optic Measurement & Inspection Special Purpose Vision 147.5 4.5 onle Lightg & Indicators 6. 6. 37.5 4. 37.5 4. RP-LM4D-6L Model RP-LM4D-6 Model RP-LM4 Series Stop Control Device AUTOCAD, STEP, IGES & PDF Components for wire rope assembly kits (page 647) Wireless Light Screens Laser Scanners Controllers & Modules Two-Hand Control Modules Interlock Switches Emergency Stop & Stop Control Actuation Trip Length 6 m Contact* Contact Action/ Contact State* open closed closed open Model RP-LM4D-6 RP-LM4D-6L Cable ed Cable NC = Normally Contact * RP-LM4 rope pulls comply with IEC 6947-5-1 positive g requirements. See data sheet or and s for more formation/clarification. RP-QM9 Series Contact Config. & Switch Diagram SD13 (p. 65) SD14 (p. 65) ACCESSORIES PAGE 647 E-STOP BUTTONS ROPE PULLS RP-RM83 RP-LS42 RP-QM72/QMT72 RP-LM4 RP-QM9 ENABLING DEVICES 137. onle AUTOCAD, STEP, IGES & PDF 6. 9. 26. Components for wire rope assembly kits (page 647) RP-QM9 Series Stop Control Device Actuation Length Contacts* Contacts Action/ Contact State* Model Contact Config. & Switch Diagram (Rope ed) 1 m (5 m each side) 2 NO RP-QM9F-1L SD15 (p. 65) Cable ed Cable NC = Normally Contact, NO = Normally Contact * RP-QM9 rope pulls comply with IEC 6947-5-1 Positive g requirements. See data sheet or and s for more formation/clarification. Call for more formation 1.888.373.6767 645
E-STOP BUTTONS ROPE PULL SWITCHES ENABLING DEVICES Rope Switches Specifications Contact Ratg g Solid-State Output Ratg European Ratg Contact Material 1A @ V ac, 1A @ V ac, 6A @ V ac, 6A @ V dc 2.5 kv max. transient tolerance NEMA A3 P3 Rated operational voltage: U e = 1 to 3V dc Rated operational current: I e = 5 ma Utilization category: DC13 Protected agast reverse polarity and short circuit. Utilization categories: AC15 and DC13 U i = 5V ac, I th = 1A Rated Surge Capacity: 2.5 kv (RP-RM83 only) Silver-nickel alloy RP-RM83 models (4-6 Hz) U e V I e /AC-15 A I e /DC-13 A 6.55 3.27 All others (4-6 Hz) U e V I e /AC-15 A I e /DC-13 A 1 6 1 1 6.4 Maximum Switchg Speed RP-RM83 models: 2 operations per mute All others: 5 operations per mute Recoended Rope Size 4 models: 2 diameter steel rope 42 & 72 models: 3 diameter steel rope 83 models: 2-5 diameter steel rope (3 recoended) 9 models: 4 diameter steel rope Maximum Rope Length RP-LM4D-6/6L and RP-QM72D-6L: 6 m RP-LS42F-75L/75LE/75LF: 75 m RP-LS42F8L/38LE/38LF: 37.5 m RP-LS42F-25L/25LE/25LF: 25 m RP-QM72D-L: m RP-QMT72D-2L: 2 m RP-QMT72E-L and RP-QMT72F-L: m RP-RM83F-75LTE/LT/LRE/LR: 75 m RP-RM83F8LTE/LT/LR/LRE: 38 m RP-QM9F-1L: 1 ; equal lengths up to 5 m on either side of switch Short Circuit Protection 1 amp Slow Blow, 15 amp Fast Blow. Recoended external fusg or overload protection. Mechanical Life RP-RM83: 1, operations All others: 1 million operations Wire Connections Screw termals with pressure plates accept the followg wire sizes Stranded and solid: 2 AWG (.5 2 ) to 16 AWG (1.5 2 ) for one wire Stranded: 2 AWG (.5 2 ) to 18 AWG (1. 2 ) for two wires Cable Entry M2 x 1.5 threaded entrance Adapter supplied to convert M2 x 1.5 to ½" - 14 NPT threaded entrance Construction RP-LS42F-..L/..LE/..LF: High-impact thermoplastic housg; zc die-cast actuator All others: Alumum alloy die cast Environmental Ratg RP-LS42F and RP-RM83F models: NEMA 4; IEC IP67 All other models: NEMA 4; IP65 Operatg Temperature RP-LS42F-..L/..LE/..LF: -25 to +7 C All other models: to +8 C Weight RP-LM4D-6:.22 Kg RP-LM4D-6L:.26 Kg RP-LS42F-..L:.48 Kg RP-LS42F-..LE and RP-LS42F-..LF:.65 Kg RP-QM72D-6L:.49 Kg RP-QM72D-L:.52 Kg RP-QMT72D-2L, RP-QMT72E-L and RP-QMT72F-L:.64 Kg RP-QM9F-1L: 3.8 Kg RP-RM83F-75LT and RP-RM83F-75LTE: 1 Kg RP-RM83F-75LR and RP-RM83F-75LRE:.77 Kg RP-RM83F8LT and RP83FLT8: 1 Kg RP-RM83F8LR and RP-RM83F8LRE:.77 Kg Certifications (RP-RM83 and RP-LS42 only) s and s RP-LM4 models: SD13 & SD14 (p. 65) RP-LS42 models: SD5, SD6 & SD7 (pp. 648-649) RP-QM72/QMT72 models: SD7, SD8, SD9, SD1 & SD RP-RM83 models: SD1, SD2, SD3 & SD4 (p. 648) RP-QM9 models: SD15 (p. 65) Wire Rope Assembly Kits (g Sprgs ordered separately) Description Rope Length 1 m Rope Length 2 m Rope Length 4 m Rope Length 5 m Rope Length 8 m 3 steel rope, eye bolts, clamps and thimbles RPAK-CH2-1 RPAK-CH2-2 RPAK-CH2-4 RPAK-CH2-5 RPAK-CH2-8 3 steel rope, eye bolts, pulleys, clamps and thimbles RPAK-CHP2-1 RPAK-CHP2-2 RPAK-CHP2-4 RPAK-CHP2-5 RPAK-CHP2-8 3 steel rope, eye bolts, clamps, thimbles and turnbuckle RPAK-CH2-1-TA RPAK-CH2-2-TA RPAK-CH2-4-TA RPAK-CH2-5-TA RPAK-CH2-8-TA 3 steel rope, eye bolts, pulleys, clamps, thimbles and turnbuckle RPAK-CHP2-1-TA RPAK-CHP2-2-TA RPAK-CHP2-4-TA RPAK-CHP2-5-TA RPAK-CHP2-8-TA Used With RP-QM72/QMT72 Models 646 More formation onle at bannerengeerg.com
Components for Wire Rope Assembly Wire Ropes Thimbles Clamps Turnbuckles Eye Bolts eys g Sprgs RPA-P1-1 Models Package Quantity Description Used With RPA-C1-1 1 m RPA-C1-2 2 m 2 steel wire rope with.5 red PVC jacket (untermated) RP-LM4 models RPA-C1-1 1 m RPA-C2-1 1 m RPA-C2-2 2 m 3 steel wire rope with.5 red RPA-C2-4 4 m PVC jacket (untermated) RPA-C2-5 5 m RPA-C2-8 8 m RPA-C3-2 2 m 4 steel wire rope with.5 red RPA-C3-1 1 m PVC jacket (untermated) RP-QM9 models RPA-T1-4 4 pcs Thimble for 2 wire rope RP-LM4 models RPA-T2-4 4 pcs Thimble for 3 wire rope RPA-T3-4 4 pcs Thimble for 4 wire rope RP-QM9 models RPA-CC1-4 4 pcs Clamp for 2 wire rope RP-LM4 models RPA-CC2-4 4 pcs Clamp for 3 wire rope RPA-CC3-4 4 pcs Clamp for 4 wire rope RP-QM9 models RP-LM4 models RPA-TA1-1 1 pc #4 Turnbuckle RPA-TA2-1 1 pc #5 Turnbuckle RP-QM9 models RP-LM4 models RPA-EB1-1 1 pc 1/4" - 2 Eye bolt (3 bolt shaft) RPA-EB2-1 1 pc 5/16" - 18 Eye bolt (3 bolt shaft) RP-QM9 models 1 pc RPA-P1-1 ey for -le use RPA-DP1-1 ey for corner turns (9-18 ) RP-LM4 models RP-QM9 models RPA-DP1-1 RPA--1 1 pc g Sprg #1 RP-QM9 models RPA--1 1 pc g Sprg #2 RP-QM9 models RPA-S3-1 1 pc g Sprg #3 (75 m) (75 m) RPA-S5-1 1 pc g Sprg #5 (38 m) RPA-S4-1 1 pc g sprg assembly with built- eye bolt, cable thimble, clamp, tensiong and RPA-S6-1 1 pc overload protection (75 m) (75 m) (38 m) (25 & 38 m) Photoelectrics Fiber Optic Measurement & Inspection Special Purpose Vision Lightg & Indicators Wireless Light Screens Laser Scanners Controllers & Modules Two-Hand Control Modules Interlock Switches Emergency Stop & Stop Control E-STOP BUTTONS ROPE PULLS ENABLING DEVICES Termal Cover SI-LS42-COVER Replacement termal cover Indicator Lamps SI-PL3T-R 1 pc Red with M2 x 1.5 (V ac/dc) SI-PL3A-R 1 pc Red with M2 x 1.5 (V ac) SI-PL3T-G 1 pc Green with M2 x 1.5 (V ac/dc) SI-PL3A-G 1 pc Green with M2 x 1.5 (V ac) RP-LS42 RP-QM72/QMT72 RP-RM83 RP-QM9 Call for more formation 1.888.373.6767 647
E-STOP BUTTONS ROPE PULL SWITCHES ENABLING DEVICES Contact/s SD1 - RP-RM83F-75LTE/LRE Series SD2 - RP-RM83F8LTE/LRE Series Cable or (156N) Set Pot 228N (3N) - - - - 2 Aux. Aux. -6-4.8-4 +4 +4.8 +6 Cable or (91N) Set Pot 133N (175N) - - - - 2 Aux. Aux. -6-4.8-4 +4 +4.8 +6 Page 642 Page 642 SD3 - RP-RM83-75LT/LR Series SD4 - RP-RM838LT/LR Series (156N) - - - - -6-4.8-4 (91N) - - - - -6-4.8-4 Set Pot 228N Set Pot 133N Cable or (3N) +4 +4.8 +6 Cable or (175N) +4 +4.8 +6 Page 642 Page 642 SD5 - RP-LS42F-75L Series SD6 - RP-LS42F8L Series (18N) Set Pot N 21-22 334 41-42 -5.8 (15N) Set Pot 14N 21-22 334 41-42 -5.8 Cable ed or Cable (3N).8 +5 Cable ed or Cable (175N).8 +5 Transition Page 643 Transition Page 643 More on next page 648 More formation onle at bannerengeerg.com
Contact/s SD7 - RP-LS42F-25L Series (6N) Set Pot 8N 21-22 334 41-42 -5.8 SD8 - RP-QM72D-6L Series Cable ed 9N 2 4 Photoelectrics Fiber Optic Measurement & Inspection Special Purpose Vision Lightg & Indicators Wireless Light Screens Cable ed or Cable (1N) Transition.8 +5 Page 643 Cable N 6 Page 644 Laser Scanners Controllers & Modules Two-Hand Control Modules Interlock Switches Emergency Stop & Stop Control SD9 - RP-QM72D-L Series SD1 - RP-QMT72D-2L Series Cable ed 15N 1.5 Cable ed 5N 2 E-STOP BUTTONS ROPE PULLS ENABLING DEVICES 5 Cable N 7.5 Cable 18N 13 Page 644 Page 644 SD - RP-QMT72F-L Series SD - RP-QMT72E-L Series 45 46 Cable ed 8N 334 45-46 2 Cable ed 8N 334 2 6 6 45 46 Cable 2N 8 Cable 2N 8 45 46 Page 644 Page 644 More on next page Call for more formation 1.888.373.6767 649
E-STOP BUTTONS ROPE PULL SWITCHES ENABLING DEVICES Contact/s SD13 - RP-LM4D-6 Series SD14 - RP-LM4D-6L Series Cable ed Cable 5N 7N 1.6 3.6 4.4 5. Cable ed Cable 5N 7N 1.2 3.2 4.8 Transition Page 645 Transition Page 645 SD15 - RP-QM9F-1L Series 4 3 - - - - 7N Lock Cable ed or Lever Right Left 3 Lock 4 7N Page 645 65 More formation onle at bannerengeerg.com
Web Only The followg standard products are still available from Banner. Please go onle to bannerengeerg.com for full descriptions and technical references. PICO-GUARD Grids & Pots PICO-GUARD Interlock Switches PICO-GUARD E-Stop 654 More formation onle at bannerengeerg.com