Radioactivity dosimeter RD01. User's Manual

Similar documents
MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

RAM GENE-1 ERK. Contamination & Radiation Meter. Operating Manual. Document #PRIR90N2.DOC Version 2.2 October 2009

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

User s Manual. Electronic Personal Dosimeter (For Gamma(X)-ray) NRF30. Fuji Electric Co., Ltd. TN514629i 1/31

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

Personal Radiation Alarm Dosimeter LK Operating Instruction Manual. Contents

stationary dose rate measuring systems

RAD-60 USER GUIDE (ALSO FOR THE RAD-50 MODEL AND ISOTRAK DOSIMETERS)

EcotestVIP PERSONAL RADIOACTIVITY DETECTOR. Operating manual ВIСТ РЭ

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

RAM GENE / RAM GENE-1

Battery-operated, hand-held alarm and measuring instruments for radiation protection

MINI-RADIAC INTRODUCTION

Portable Survey Instruments NISP-RP-01

Dosimeters/Survey meters

Controls Surface mounted pushbuttons Suitable for gloved use. Buttons Side - On/Off Front Menu Scroll Pin Hole Setup access

Radiation Alert Frisker INTERNATIONAL

Contamination Meter Users Manual

LUDLUM MODEL 25 AND 25-1 PERSONAL RADIATION MONITOR USER S MANUAL. October 2014 Serial Number and Succeeding Serial Numbers

Surface Contamination Monitor. Operation Manual

Identify the following features and specifications for the ESP1

HEALTH AND SAFETY MANUAL

LUDLUM MODEL 26-1 FRISKER USER S MANUAL. April 2017 Serial Number PF and Succeeding Serial Numbers

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Nuclear Associates

Using the GammaRAE II Personal Radiation Detector

Kata products Kata DGM-1500 Turva

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Detecting Radiation. Protection through Detection. February Animations in this training work best in Windows XP

TRACERCO T402 and T402HR USER MANUAL

Ranger EXP RADIATION A L E R T

PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER РМ1703МО-1 OPERATION MANUAL

User Manual. Non-contact Infrared Thermometer.

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Radiation Alert Area Monitor

LUDLUM MODEL 26 FRISKER USER S MANUAL. December 2016 Serial Number PF and Succeeding Serial Numbers

Installation and Operation Instructions ELECTRIC FIREPLACE X56WMEF1BLK X56WMEF1WHT

Our Extended Personal Electronic Dosimeter (PED) Family

PRELIMIN INTERNATIONAL

This instruction manual explains the use of three models listed on the left.

LUDLUM MODEL ALPHA, BETA, GAMMA HAND DETECTOR. June 2016 Serial Number and Succeeding Serial Numbers

Radiation Control and Monitoring System on the HTTR

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

CONTAMINATION MONITORING INSTRUMENTATION RCT STUDY GUIDE LEARNING OBJECTIVES:

Instrumentation. Post RDD Event Urban Reoccupancy. James P. Menge PE. The world leader in serving science

RAE Systems. Using the MeshGuard. Protection Through Detection

MetRad1 Handheld Metal/Gamma Detection Unit. Operation Manual. Berkeley Nucleonics Test, Measurement and Nuclear Instrumentation since 1963 BNC

Radiation Safety and Equipment Considerations. Bonnie Meilner Regional Sales Manager LAURUS Systems Inc.

User Guide. MeshGuard Gamma

LUDLUM MODEL AND LUDLUM MODEL ALPHA, BETA, & GAMMA DETECTORS

TRACERCO Radiation Monitor

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Safety Siren Pro Series3 Radon Gas Detector

Homeowner s Installation Instructions & Operating Manual

RadEye Selection Guide 08/2012. Handheld Detection. for Any Scenario

ADVANCED RADIATION DETECTION EQUIPMENT

Homeowner s Installation Instructions & Operating Manual

HEALTH POT MODEL: EHP-G1583G(RD) EHP-G1584G(RD) Owner s Manual. Please read this manual carefully before operating your set.

HIn3550 Magnetic Field Monitor User's Manual

HEALTH POT MODEL: EHP-E1881G(WH) EHP-E1882G(OR) Owner s Manual. Please read this manual carefully before operating your set.

DMC 3000 Quick User s Guide

SERVICE MANUAL REFRIGERATION

Any scenario. Maximum protection. Radiation detection solutions for safety and security

1126 Series Ceiling Mount PIR Motion Detector

Homeowner s Installation Instructions & Operating Manual

910A DOSIMETER CHARGER, AC-POWERED

E1000 Portable gas detector

Any scenario. Maximum protection.

MODEL 951 RADIATION DETECTOR

Maximize safety and productivity. Thermo Scientific Nuclear Power Radiation Detection and Monitoring Solutions

LUDLUM MODEL 44-2 GAMMA SCINTILLATOR. February 2018 Serial Number PR and Succeeding Serial Numbers

OWNER S MANUAL CLEANING ROBOT

Advanced Radiation Detection Equipment

IMR EX610. Portable Gas Detector. Operation Manual

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

21st Century of Energy Efficient cooking! Premium Induction Cooker Model: CT-IN-739A

Chapter 5 Inspection and maintenance

PCS 2000 CONTROLLER USER GUIDE PCS 2000 CONTROLLER. Contents

LUDLUM MODEL 44-9 ALPHA, BETA, GAMMA DETECTOR. February 2010 Serial Number PR and Succeeding Serial Numbers

IMPORTANT INSTRUCTIONS OPERATING MANUAL

HEALTH AND SAFETY PROGRAM 406 IONIZING/NONIONIZING RADIATION PROTECTION

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

ß-Aerosolmonitor FHT 59 C

LUDLUM MODEL RK2 RESPONSE KIT. October 2017 Serial Number and Succeeding Serial Numbers

Instruction Manual QUICK 855PG PROGRAMMABLE SMD REWORK STAION

HRS55PG PROGRAMMABLE SMD REWORK STAION. Instruction Manual. Thank you for purchasing our SMD Rework station. The unit is exclusively designed for

Portable Air-conditioner

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

TRACERCO Radiation Monitor. Instruction and Maintenance Manual for Model No. T202

IMPORTANT SAFETY INFORMATION:

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

TAIJI HOTCABI Towel Warmer

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

HV2R ROTARY LASER INSTRUCTION MANUAL

IMPORTANT SAFEGUARDS Danger! Danger of burns!! Important!

DMC 2000 Personal Electronic Dosimeter

Gallery Electric Fireplaces

Victoreen Primalert 35 Area Radiation Monitor

Transcription:

Radioactivity dosimeter RD01 User's Manual 2011

Contents Introduction 2 Technical specifications 4 How does RD01 work? 5 How to use RD01? 7 Power 10 How to carry out measures correctly? 11 Warranty 12 Precautions 13 Storage and transportation 14 Introduction Purpose Radiation dosimeter ICDE RD01 is designed for measuring the product radioactivity level, detecting objects contaminated with radioactive elements and gauging the accumulated radaiation dose. Base Kit The base kit of radiation dosimeter RD01 consists of: Radiation dosimeter RD01 pcs 2 batteries (AAA size) 2 pcs Warranty cupon 1 pcs Rigid paperboard box 1 pcs 2

Geiger - Mueller Tube (inside) Liquid Crystal Display Red light (alarm) Buzzer Yellow light (mode) Push button (Menu-ON) Push button (Sound-OFF) Green light (sound mode) 3

Technical specifications Sensitive to radiation Detector Measurement units Range of indicated radiation level β, γ, & χ-rays Geiger-Muller counter μr/h or mr/h to 100000 μr/h (1000 μsv/h) Measurement basic relative errors ±20% Alarm threshold (LED and sound alarm) Time of measurement Display format of indication Power supply Power voltage range Time of continuous work of the device Display Dimension, max height x width x thickness Weight: (without batteries) Operating temperature range 4 From 100 μr/h ( 1 μsv/h ) 4 seconds Continuously, numerical, 2 digit 2 x AAA batteries 2.0-3.5 V >=100 hours LCD 2 digits, monochromatic 129 x 69 x 20 mm 49 g from 10 to +60 C

How does RD01 work? The RD01 unit utilizes the Geiger-Mueller (GM) tube to detect radiation (Beta, Gamma and X-Ray a.k.a. Roentgen rays). Radiation passes through the GM-tube and causes gas ionizationto occur with inside the tube. When ionization has achieved a certain level, an electrical discharge takes place. Each of the discharges is detected electronically and registered within the RD01 s microprocessor. Depending on the frequency of discharges, the level of radiation is calculated by the IC chip ia a count during a certain period of time. Units Radiation levels are shown in micro-roentgens/hour (μr/h) or milli- Roentgens/hour (mr/hr) where 1000 μr/h = 1 mr/h and 1000 mr/h = 1 R/h. The abbreviation mrtg is equivalent to mr. There are many different units to measure radiating doses. Roentgen - in use since 1928 to measure generated radiation or exposure dose. Sievert - in use since 1979, where 100 Roentgen = 1 Sievert, provided that only the biological effect of radiation is considered. 5

If you want to convert the units to Sieverts (SI derived unit), use this conversion chart: Displayed Red light Roentgens per hour Sieverts per hour Danger level after 1 hour 10 off 10 μr/h 0.1 μsv/h 99 off 99 μr/h 0.99 μsv/h.12 flashes 0.12 mr/h 1.2 μsv/h 1.0 flashes 1.0 mr/h 10 μsv/h 10 flashes 10 mr/h 0.1 msv/h 99 flashes 100 mr/h 1 msv/h EE flashes 1 R/h 10 msv/h EE flashes 10 R/h 100 msv/h EE flashes 100 R/h 1 Sv/h Background radiation Low level radiation Not recommended to stay here Daily human limit rate Do not stay here Substantial exposure Strong exposure Extreme danger 50% chance of death 6

How to use RD01? Beginning to use the device: Install the power source, for more information how o install power source, please consult the paragraph Power. Turn the device on by pressing and holding he button ON down for one full second. The mode radiation power is on, whenever the RD01 unit is turned on, it performs calculations non-stop. Press and hold the OFF button down for 1 second to turn off the unit. Display modes There are two display modes available: Radiation power mode (or dosa rate mode), which shows current radiation level; and Radiation dosa mode, which shows total or accumulated radiation dosa since the unit has been turned on. To switch between the display modes, press MENU (ON) button for less than 1 second. When radiation dose mode is on, a yellow light will turn on. 7

Alarms If the radiation dosa rate gets higher than around 100 µr/h, a red light will flash rapidly and an alarm will sound with a continuous beeping sound. If the battery gets low the red light will flash once every 8 seconds. The alarm beeps can be turned on/off by changing into one of four different sound modes (see Sound modes ). The red alarm light can not be switched off without switching off all device. Sound modes Each of the electrical discharges gives the user a clicking sound. If the radiation dosa rate gets higher than around 100 µr/h, an alarm will sound with a continuous beeping sound. The clicks and alarm beeps can be turned on/off by changing into one of the four different sound modes. If the SOUND button is pushed for less than one second (when the unit is on), the sound modes are cycled through Modes 1-2- 3-4-1-... These Modes will not affect measurements or display readings: Mode Clicks Alarm Green LED flashing #1 on on off #2 off on once every 2 seconds #3 on off twice every 2 seconds #4 off off twice every 2 seconds, the second light is longer 8

Reading current radiation in Power mode In Power mode yellow light is off. If the decimal point is not shown and the red light is not flashing, unit is reading low radiation levels and shows it in μr/h (e.g. 09 9 μr/h). If the decimal point is shown the unit shows radiation levels in mr/h (e.g..15 0.150 mr/h or 150 μr/h). If the decimal point is not shown but the red light is flashing radiation levels are shown in mr/h (e.g. 12 12 mr/h). In power mode readings are correct up to 25 mr/h. If dosa rate exceeded the 100 mr/h, unit will show EE on the display. Reading total radiation in Dose mode Reading total radiation in Dose mode if yellow light is on. The radiation dose is shown always in mr. Dose mode measuring rate is up to 100 mr. If dosa exceeded the 100 mr, unit will show EE on the display. 9

Power AAA type batteries can be used to power the device. To install, remove or change the battery, undo the screw on the back of the unit, open the case and unplug the battery. Strictly observe polarity when you install power elements, otherwise the device may fail. If the battery gets low the red light will flash once every 8 seconds the readings are still accurate at this state. If the battery gets too low, the unit will turn itself off. When the device is turned off, you can leave the power elements installed, the batteries and accu-mulators are not spent if the device is in standby mode. If the unit is not used for extended periods of time to save the battery power it is recommended to remove it from the unit. 10

How to carry out measures correctly? Measuring radiation background of objects: 1. Measure the level of radiation background several meters away from the target; 2. Move the device directly to the target and measure radiation background as close as possible to the target; 3. Compare the resulting data with the radiation background level measured in step 1. The difference of readings in step 1 and step 2 will represent the radiation background of the target. To evaluate radioactive contamination of liquids, the unit must be placed above open surface of the liquid. To protect the unit from contact with the liquid, it is recommended that the unit should be wrapped in a polyethylene bag, but ensuring that the wrapping is one layer of plastic only. 11

Warranty The warranty period for the device is 12 months, the warranty period begins after the ultimate user receives the device. The manufacturer guarantees efficient operation of the device provided that the user observes the operating conditions, safety measures, and requirements to storage and transportation described in this manual. If any malfunctions are detected in the device, the warranty period shall be extended for time uring which the device is under warranty repairs and the ultimate user is unable to use the device. Warranty repairs are done at the manufacturer's factory. This guarantee shall be void if: the serial number of the device is not the same as the number in the guarantee coupon; the guarantee coupon is not available or illegible because of damage, corrections or erasures; requirements to shipment, storage and operation described herein are violated; malfunction is caused by third party actions or a force majeure; the device or its component parts has signs of shock or other mechanical impact (scatches; cracks, chips, loose parts inside the case, color spots on the display, etc.); malfunctions are caused by foreign objects, liquids and insects inside the device; the user does or attempts to disassemble and repair the device. The name of the device is written on the case. The serial number is written in the battery holder. The manufacturer does not seal the device. Please send all your comments to our e-mail addresses at our official website: www.icdelectronics.com 12

Precautions Do not drop the unit. Protect the unit from shock and other mechanical impacts that can damage it. Do not use the unit in conditions of high humidity, under or in contact with water. Do not leave the unit in intensive sun light or high temperatures. Do not leave the unit for a long time near devices that generate strong magnetic fields and where strong electrical magnetic signals are generated. Do not perform measurements close to cell phones and microwaves, this may affect the unit's readings Do not try to repair the device on your own. Strictly observe polarity when you install power elements, otherwise the device may overheat and fail. Prevent foreign objects from getting inside the device through the or perforation on the side of the device or during the removal or installation of batteries. Maintenance The unit s maintenance includes: removal of dust from the outer surface of the device; timely changing or charging the power elements; if the device is not used for a long time (more than 2 weeks), power elements must be uninstalled; clean the display with soft cloth only. 13

Storage and transportation Protect unit from moisture and temperature above 40 C. The packed device can by shipped by any type of transport over any distance; the package ensures safety of the device during transportation and storage, provided normal climatic conditions. During shipment, the unit must be protected against humidity and overheat. Until operation, the device must be stored in the factory package, in a warehouse with air temperatures from -5 C to +40 C and maximum relative air humidity 80% (at temperature +25 C). The device may not be stored without the package. If the device remained at below-zero temperatures for a long time, it must be left indoors for 2 hours before use. 14

Made in the EU Enjoy your new RD01!