INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

Similar documents
Multi-Mode Annunciators

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Remote Chexit Module (RCM) System. General Information

DE5300 Delayed Egress System. General Information

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Accessories. Desk Top Controls

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Delayed Egress System DORMA EMDE

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Egress Devices for Code Compliant Access-Controlled Egress Doors

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

232xt Wiring Diagrams and Specifications SPECIFICATIONS: REV 1.01

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

Pilfergard Door Alarms

INSTALLATION INSTRUCTIONS EXIT CHECK DELAYED EGRESS EMLOCK 1511S / 1511T

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

WIRING DIAGRAM AND INSTRUCTIONS

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

380 SERIES REMOTE SIREN ETSA380R

CLEANROOM MONITOR CR3A Network - Installation Instructions

Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

DOLKPS1KB Programming & Installation Manual

SP-1000X. Panic Device Power Controller Installation Guide. Rev

v Model No: TIMER Multi-function Timer Module Please note: * eeee on the display indicates a non valid dip-switch setting.

Installation, Operating and Maintenance Manual

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

KP-100A BACKLIT DIGITAL KEYPAD FOR ELECTRIC LOCK AND SECURITY SYSTEM INSTALLATIONS

CORNELL Emergency Response Systems

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

STERLING 10 Control Panel with Remote Keypads ICON and LCD INSTALLATION MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

RESTROOM CONTROL KITS

385 SERIES REMOTE HANDHELD SIREN ETSA385HR

Product Manual SZ1144

SPLIT-DECODED CONTROLLER

Exit Check Integrated Delayed Egress Locks

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Alarm Panel Operating Instructions

Tailgate > Entry Sentry > ES5200

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

EC-P Zone Intruder Alarm System

Honeywell ENERGY SAVINGS KIT

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

MR-2602 Two Zone Fire Alarm Control Panel

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

INSTALLATION/OPERATING INSTRUCTIONS SEQUENCING PANELS

Application, Installation, Operation & Maintenance Manual

3. Compatible Sensor Wiring 4. Batch Contact Wiring See section 9 for simple and advanced mode configuration options.

Exit Check Integrated Delayed Egress Locks

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

AL800ULADA. NAC Power Extender. Installation Guide

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

Mx-MTB HVAC Controller

Addendum for STI-6406 with Dual Access Control

T8411R Electronic Heat Pump Thermostat

VANDAL RESISTANT BACK-LIT WEATHERPROOF RFID ACCESS CONTROL KEYPAD

Z24 Wireless Zone Controller Professional Installation Guide

Installation Manual Premier 412/816/832. Issue 10

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

TABLE OF CONTENTS TABLE OF CONTENTS 1

Exit Stopper. STI-6400 Series

SPLIT DECODED SECURITY KEYPAD

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

DS160/161 Request To Exit PIR sensors Installation Instructions

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

OPERATION & MAINTENANCE MANUAL GUARDIAN SPACE PRESSURE MONITOR WITH REMOTE AUXILLARY ALARM

EVO192 v3.0 Fire and Burglary What s New

Independent Zone Control (I.Z.C.)

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

FMR Installation Instructions. Addressable Fire System Controller

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

DOLKPL1KB DOLKPS1KB DOLKSF1KB

AL600ULADA. NAC Power Extender. Installation Guide

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

Specification/ Data Sheet

Series. Access Power Controllers. Installation Guide

INSTALLATION AND OPERATION INSTRUCTIONS 303, 304, 305, CRH, CRQ, CFA SERIES 2250 WATT MODELS

Conventional Fire Alarm System 2014 V1.2

MODEL MP-1S OVERSPEED UNIT

v3 360 Dual Technology Low Voltage Occupancy Sensor with Light Level, Isolated Relay and Manual On feature

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

Exit Check Integrated Delayed Egress Locks

Product Manual SZ1145

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

SECURITRON MODEL DPA-12 AND DPA-24 DOOR PROP ALARM TIMERS INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATIONN GUIDE & OPERATION MANUAL

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RE6100 Series Helix Security and Automation Platform

Transcription:

80 Avenida Acaso, amarillo, a. 90 (80) 9-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUTIONS EA SERIES DOOR PROP/EXIT ALARM Model EA-SN Model EA-78 Model EA-708 (cylinder not included) The SD EA Series offers Exit Alarm, Forced Door Alarm, and Door Propped/Held Open Alarm monitoring capabilities to any controlled opening. It may be used as a standalone device or easily integrates with any access control system. Units are typically mounted adjacent to the opening, and provide local visual and audible alarm annunciation. An integral key switch is available for local bypass & alarm reset controls. A built-in alarm relay is also included for. FEATURES Exit alarm on door opening Door prop alarm after adjustable timed delay Manual or automatic alarm reset Local 8dB Piezo buzzer alarm Integral LED status indicator Main relay output for remote alarm notification Auxiliary relay output for door position status or bypass/alarm status Optional key reset/bypass switch ompact universal mounting EA SERIES TEHNIAL SPEIFIATIONS Input Power: 60mA @ or VD (Auto-sensing) Mounting: EA-SN: Single Gang, /" Thick aluminum plate w/ security screws (-/8" depth recommended) EA-708, -78: Double Gang, /" Thick aluminum plate w/ security screws Alarm Sound Level: 8dB @ ft, Piezo Buzzer Status Indicator: Bi-color LED Trigger (DPS) Input: Dry, N/ or, field selectable Reset/Bypass (ontrol) Input: Dry, or N/, field selectable Alarm (Main) Output: Form, A @ 0VD (Resistive) Auxiliary Output: Form, A @ 0VD (Resistive) Wiring: Overall Dimensions: Screw terminals EA-SN: "h x."w x.6" d EA-708, -78: "h x "w x.87"d P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-7 Page Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email engineer@sdcsecurity.com

EA Series Board Layout (Back View): s 6 N *The state of the Main & Aux. relays are shown when the unit is not powered. 7 N onfiguration Jumpers Numbered through. By default, all jumpers have been set to OFF. Use the () supplied jumpers, as required. See the table below for a functional description of each jumper. Adjustable Alarm Timer Determines the amount of time a door can be propped open before an alarm is activated. Adjustable from to 60 seconds. Turn clockwise to increase time. Input Power Terminals Requires a or VD +/- 0% power supply (auto-sensing). ontrol Input Terminals Dry input used for bypass & alarm reset. Field-selectable as normally open (default) or normally closed. In a secure state, a held input will bypass the unit. In an alarm state, a momentary input will reset the alarm providing the door is closed. This input is factory pre-wired for key switch model EA-78. Door ontact Input Required for all models. Monitors the open/closed status of the door. Fieldselectable as normally open or normally closed (default). 6 onfiguration Jumpers Jumper OFF Jumper ON = Latching Alarm Disabled (Alarm resets on door closure) Enabled. (Requires use of ontrol Input to reset an alarm OR Jumper #) = Alarm Auto Reset Disabled Auto-reset 60 sec. after door closure. (Requires Jumper # to be ON) = ontrol Input Polarity Normally Open Normally losed = DPS Input Polarity Normally losed Normally Open = Aux. Relay Function Follows DPS Input Follows Bypass/Alarm State Alarm Relay Output Relay is energized when the unit is powered. An alarm state or loss of power will de-energize the relay. 7 Auxiliary Relay Output Relay may be configured to follow the DPS input OR to follow a bypass/alarm state. P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-7 Page

LED Status Indicator: Door Status Unit ondition LED Status Main Relay losed Secure Solid Green G Energized De-energized Energized Open Pre-alarm (-60 sec.) Solid Green G Energized Energized Energized Open Alarm Solid Red R De-energized Energized De-energized losed Bypassed Flashing Green G Energized De-energized De-energized Open Bypassed Flashing Green G Energized Energized De-energized *Relay state shown with N/ Door ontact Key Switch Operation (EA-708 or 78 only): TE: Unit must be Secure to be Bypassed. Door must be closed to reset an alarm condition. Aux. Relay* (Jumper OFF) Aux. Relay (Jumper ON) Bypass EA-78 Reset Bypass (Maintained) 90 ounter-clockwise. Key may be removed. Return to vertical position to re-secure. Alarm Reset (Momentary) lockwise. Key returns to vertical position upon release. EA Series Operational Modes: Bypass EA-708 Reset See Page for Mortise Key ylinder installation Bypass (Maintained) Turn counter-clockwise until OFF switch is activated. Reactivate the switch to re-secure. Alarm Reset (Momentary) Turn clockwise until momentary switch is activated. Wiring Example # Non-latching (auto-resetting) Exit Alarm or Door Prop Alarm. Opening the door will initiate the pre-alarm timer. losing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger. Alarm resets on door closure. Bypass the alarm by activating the integral key switch or via remote bypass switch. or VD N/ SD Model TR-, TR-, or 600 Series Door ontact: SD Model M- or similar EA-SN: Optional Remote Bypass; Pre-wired for model EA-78 Auxiliary Relay follow DPS input (a) All jumpers are set OFF (default) (b) Adjust the alarm delay timer (-60 seconds), as required. (c) Install & terminate a N/ door contact. (d) Install & terminate optional output relays, as needed. See page for relay descriptions. (e) Apply power & test. P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-7 Page

Wiring Example # Latching (Manually Reset) Exit Alarm/Door Prop Alarm. Opening the door will initiate the pre-alarm timer. losing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger & latch. Alarm must be reset by using the integral key switch (EA-708 or EA-78 only), or by remote control switch. Bypass the alarm by activating the integral key switch or via remote switch. s N or VD N/ SD Model TR-, TR-, or 600 Series Door ontact: SD Model M- or similar EA-SN: Requires Remote Reset Switch; Pre-wired for model EA-78 N Auxiliary Relay changes state when the unit enters bypass mode or alarm mode (a) Jumpers & are installed. Jumpers,, & are set OFF. (b) Adjust the alarm delay timer (-60 seconds), as required. (c) Install Remote reset switch. Required for EA-SN; Optional for EA-708 or EA-78. (d) Install & terminate a N/ door contact. (e) Install & terminate optional output relays, as needed. See page for relay descriptions. (f) Apply power & test. Wiring Example # Double-Door Latching Exit Alarm/Door Prop Alarm with Timed Reset. Opening the door will initiate the pre-alarm timer. losing the door before the timer expires resets the timer. If the door remains open and the timer expires, an audible alarm will sound and the Main Relay will trigger & latch. The alarm will automatically reset 60 seconds after door closure. The alarm may also be reset by using the integral key switch (EA-708 or EA-78 only), or by remote control switch. Bypass the alarm by activating the integral key switch or via remote bypass switch. s N or VD N/ N/ SD Model TR-, TR-, or 600 Series Door ontacts: SD Model M- (x) EA-SN: Requires Remote Reset Switch; Pre-wired for the EA-78 N Auxiliary Relay changes state when the unit enters bypass mode or alarm mode (a) Jumpers, & are installed. Jumpers & are set OFF. (b) Adjust the alarm delay timer (-60 seconds), as required. (c) Install Remote reset switch. Required for EA-SN; Optional for EA-708 or EA-78. (d) Install & terminate N/ door contacts in series. (e) Install & terminate optional output relays, as needed. See page for relay descriptions. (f) Apply power & test. P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-7 Page

EA-708 Mortise Key ylinder Installation: ASSEMBLY DETAIL SOUND DAMPENER All Exit Alarm Assemblies are shipped with a sound dampening cap loose in the box. Switch Mounting Bracket triangular tabs Locknut Install the unit without the cap for full volume. Install the unit with the cap as shipped for complete dampening. Install the unit with the center hole punched out for partial dampening Key ylinder SD Part# YL-KD Or supply compatible to -/8 standard or interchangeable core mortise key cylinders (not included) ENTER HOLE AS SHIPPED Use tailpiece supplied with SD Part# YL-KD, or Ilco 86G-00-0 Standard am equivalent. Faceplate Adjustable Switch Assembly ENTER HOLE PUNHED Ensure that the cam makes contact with the center of the switch plunger. omplete the wiring connections by carefully routing the () white & () yellow wire leads behind the board. Terminate the () yellow wires to ontrol terminal A. Terminate the () white wires to ontrol terminal B. SWITH WIRING (Reset) (Bypass) A B OM OM P:\INSTALLATION INST\Accessories\INST-DOOR PROP.vsd Rev A 07-7 Page