FOGGER INSTALLATION. com. www. NURSERY/GREENHOUSE. Reduce greenhouse temperatures, increase humidity levels or help promote propagation. SENNINGER.

Similar documents
com LOWER APPLICATION INTENSITY www. MECHANIZED IRRIGATION

Lowering Application Intensity

Dan Fogger/Mister.

CLOSE SPACING LEPA BUBBLERS

Sprinkler Systems Design Guide

SPRINKLER SYSTEMS DESIGN GUIDE AUTOMATED WATERING SYSTEMS FOR GREENHOUSE AND NURSERY

WOBBLER TECHNOLOGY Irrigating Orchards and Groves

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

FOGGING & HUMIDIFICATION PAPER STORAGE TEXTILE MILLS LIQUID STORAGE TANKS AIR DUCTS PRODUCE STORAGE ROOMS GREENHOUSES HATCHERIES CONCRETE PIPE CURING

Dry Water in the Greenhouse

Hanging Basket Watering Systems

Tavlit solutions for Oil Palm Tree Irrigation

Sullair Drains for Compressed Air Systems Zero Air Loss and Timed Solenoid

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

Greenhouses. 4/25/2018 DUBI SEGAL

Insty-Pac Steam Humidifiers

Water mist nozzles With anti-drip

ENCLOSED UNIT TECHNICAL MANUAL Items # &

High Performance Hose High Performance Hose

TURFGRASS - ANTHRACNOSE (APPLICATION INTERVAL/TIMING: 14 DAYS)

Antari Low Fog Machine

Pesticide Application Equipment for use In Greenhouses

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

HIGH-PRESSURE ATOMIZING SYSTEM. Humidification and adiabatic cooling. Energy efficient Reduces cooling load Multiple zone capabilities

DuraSpray V Viton gaskets and seals. Model Industrial. DuraSpray

Irrigation Tech II HYDRAULIC TROUBLESHOOTING

N E T A F I M U S A. A Labor Saving. Drip System. for Watering. Potted Plants. 6Nf1AflM. IRRIGATl6N-MART ' GROW MOOE WITH LESS.

NILEATOR ATOR. Dyna-Fog ANILE. Cold Fog ULV Aerosol Applicator. Instruction Manual For Operation, Service and Maintenance

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

100% NON-WETTING jumbo non-clogging orifce. PRECISE HUMIDITY CONTROL Evaporative cooling LOW MAINTENANCE

CHAPTER 3 BASIC STEAM CYCLE

PHIREX AUSTRALIA CATALOGUE & DATA SHEETS. April 2005, Rev 2. Fogex Water Mist Fire Protection System Components PHX-3064

Optimizing the Water Relations of Cuttings During Propagation

Technology Transfer of Greenhouse Aeroponic Lettuce Production Information to Alberta Growers,

3500 SERIES CONVECTION STEAM COOKER PARTS AND SERVICE MANUAL

model NO. LSS GALLON SKID MOUNTED HIGH PRESSURE SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

FEEL THE COOL FEEL THE MIST

USE OF A LOWER RATE WHEN APPLIED ON CEREALS AT THE HERBICIDE TIMING (FEEKES 4-6) - AL, AR, AZ ETC.

Evaluation Of Two Growing Systems For Cut Snapdragon Production: Tray vs. Ground-Bed

Part III. Crop Information

Chapter 5. Editor. Ted W. van der Gulik, P.Eng. Senior Engineer. Authors. Stephanie Tam, P.Eng. Water Management Engineer

Cooling Systems for Georgia Dairy Cattle. Dr. John W. Worley, Extension Engineer

StorOx Works: The Research Speaks for Itself

Vacuum Pumps and Accessories

Is your spraying equipment well adjusted? Orchard Spray Equipment: Set Up and Calibration by Greg O'Sullivan

Your Pope Simple Set Automatic Tap Timer

Cloud Tech Dust Suppression System

Genesis Whole House Chlorination System Page 2

SELF-CONTAINED POWER MISTER

Low Pressure Sprinkler and Fan Cooling System Design for Dairy Facilities

HYDROGEN SULFIDE REMOVAL SYSTEMS

This supplemental label expires December 31, 2017 and must not be used or distributed after this date.

Selecting the Right Sprayer

HE365A,B Powered Flow-Through Humidifier with

Removing The Potential For Condensation In An Electronic Cabinet

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology

FLOW-THROUGH FURNACE HUMIDIFIER

SHURFLO BLASTER II MARINE WASHDOWN PUMP PRODUCT TECHNICAL DATA SHEET

Your Single Source for Cooling Tower Components! Cross Flow Crown Nozzles

High Pressure Fog System

SYSTEMS for CATALYTIC FILTERS

FREE How to get up and running using waterwise drip irrigation.

Antari X-310 ORDERCODE 60663

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

Automatic Water System Pump SERIES

Z.D.S SS Dispenser

PrimePour TM Operation Manual

PRESSURE FOG HIGH ATOMIZING HUMIDIFICATION SYSTEM

Low Volume Irrigation

Duct Mount Atomizing Humidifier

Residential Duct Mount Builder s Box Media Air Cleaner

Craig R. Miller Parks & Open Space Manager Irrigation

280 SERIES STEAM CONVERTING VALVE SIZING AND SELECTION. 1. Introduction Design Properties Sizing and Selection Criteria...

Controlled Humidity Solutions for Potato Storage

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

High-Pressure Atomizing System

CUFFED FAST-PAC EXTERNAL MOUNT MULTIPLE TUBE ASSEMBLY

DRIP IRRIGATION. Smart Water Use. Features & Benefits

Standard and CELDEK Evaporative Cooler Modules Installation, Operation, and Maintenance Manual

CONDENSING WATER HEATERS GAS FIRED 55 I 80 I 119 I U.S. GALLONS

UltraDry s Features and Benefits

Cool, Clean and Comfortable Nortec HP-Series. Adiabatic In-Duct High Pressure Humidification System... Simply Awesome

The SMART COOLING adiabatic precooling panels will reduce up to 30% of your cooling systems energy consumption!

EVAPORATIVE COOLING AND HUMIDIFICATION. High-Pressure System Wetted Media System

Atomizing Nozzle Humidifiers. Designed for Air Handling Systems, and Manufacturers, Processors and Distributors of Humidity Sensitive Products.

BYPASS AND POWER HUMIDIFIER OWNER S MANUAL

OWNER'S MANUAL Model VPW46H 120V., 60 Hz., 13 Amps. PRESSURE WASHER. FANTOM 94 Main Mill Street, Door 16 Plattsburgh, NY Tel.

DISTILLATION. The Best Distillation Times Two! 4 FI-STREEM Tap/Pretreated 30 Liter Storage Reservoir WP54 50 Liter Storage Reservoir

All about the Use &Care

OWNER S MANUAL. The following parts are included with your Ranger (Model# W01698): (1) Wheel Deflector & Adapter. (1) FlowKeeper Valve

Guidelines for Managing Onion Thrips on Onion

Antari Z-300 ORDERCODE 60661

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

Model Series ELECTRIC WATER SYSTEM PUMP. PumpAgents.com - buy pumps and parts online. Model Series. Automatic Multi-Outlet FEATURES

Ultra-sorb Steam Dispersion Panels

Easy Dose Chemical Injection and Dispensing System DEMA Engineering Company

ENERGY EFFICIENCY PERFORMANCE SAVINGS SERVICE MANUAL R-290

Installation Instructions for. OmniFount

READ AND SAVE THESE INSTRUCTIONS AUTOMATIC HUMIDIFIER. The Best Cure For Dryness OWNER S MANUAL FOR MODELS 448, 558, 568, 600, & 700

Transcription:

Established 1963 FOGGER INSTALLATION NURSERY/GREENHOUSE Reduce greenhouse temperatures, increase humidity levels or help promote propagation.

Fogger The Fogger is Senninger s solution for reducing greenhouse temperatures and increasing humidity levels. It creates ideal conditions for plant propagation by distributing extremely fine droplets with excellent pattern uniformity. Cooling and Humidification Fogging systems are extremely efficient tools for controlling greenhouse climate conditions. Climate control in a greenhouse results from the exchange of energy between hot air and the extremely fine droplets created by Senninger s Foggers. As water droplets are released, they quickly convert from liquid to vapor due to their small size and the high temperatures in a greenhouse. During this process, they absorb the hot air at a rate of 16,726 calories per ounce (or 590 calories per gram) of evaporated water, which helps cool the air temperature and increases humidity levels inside a greenhouse by approximately 6 to 9 F or 4 to 6 C. The overall results and effectiveness of this system depend on outside temperature and humidity levels. Propagation Oversaturation is a mon cause of plant diseases, such as fungi and moss, and a danger to greenhouse growers attempting propagation. Foggers can create the ideal conditions for plant propagation by reducing air temperatures and increasing humidity levels inside a greenhouse without wetting plant leaves. Due to the Fogger s smaller droplet size, there is also less soil saturation and more oxygen available to growing plants. The Fogger can also be used for foliar feeding, and to apply insecticides and fungicides. It saves time and provides a uniform application. FEATURES Droplets averaging 65 microns in size at 60 psi (4.1 bar)* Uniform blanket of droplets for propagation and chemical applications Built-in check valve provides instantaneous on-off and prevents line drainage Simple, tool-free assembly and disassembly for cleaning and servicing Engineering-grade UV-resistant thermoplastic construction for protection from corrosion Operating pressures: 45 to 60 psi (3.10 to 4.1 bar) Flow averages per nozzle: 1.6 gph (6.05 L/hr) Easily retrofits existing fogger systems Two year warranty on materials, workmanship and performance; nozzles are warranted to maintain correct orifice size for five years * Droplet size measured using the Sauter Mean diameter Fogger VS. Mister Comparision 1 Fogger Mister Ideal for plants susceptible to root disease YES NO Remended for propagation of seeds and non-rooted cuttings YES NO Remended for propagation of rooted cuttings NO YES Cooling & Humidity Control YES NO

Assembly Fogger Select a Fogger Assembly Senninger s Foggers can be installed either as a single head fogger or on a 4-way adapter. Each configuration provides different precipitation rates. Built-in Check Valve Senninger Foggers e with a built-in check valve that prevents leakage when a system is shut off and assures a consistent start-up time. The unit is easy to take apart for cleaning and servicing. (1) Firmly grasp the retainer assembly and the nozzle by the pointed ears. (2) Pinch the pointed ears together until you hear a click to open the Fogger. To rebine the parts, simply place the retainer assembly on the nozzle and firmly grasp the pointed ears of each part. Pinch the nozzle and the retainer assembly in different directions until they tighten. 1. 2. 3. Fogger with 1/4" barb base Fogger with 3/8" BSW base Four Foggers with 3/8" BSW base 1. FOGDA24-250BRB For installation of one Fogger with 1/4" barb base Double Barb Connector - 0.25", PE Slip Over Weight - 1 ounce, Vinyl Tubing - 0.25"- 24" length, (1) Fogger with 1/4" barb connection 2. FOGDA24-375BSW For installation of one Fogger with 3/8" BSW base Double Barb Connector - 0.25", PE Slip Over Weight - 1 ounce, Vinyl Tubing - 0.25", 24" length, Fogger Nipple x Barb Connector, (1) Fogger with 3/8" BSW connection 3. FOGDA24-375BSW-4 For Installation of four Foggers with 3/8" BSW base Double Barb Connector - 0.25", PE Slip Over Weight - 1 ounce, Vinyl Tubing - 0.25" - 24" length, Fogger Nipple x Barb Connector, Fogger 4-Way Cross Adapter, (4) Foggers with 3/8" BSW connection 2

Fogger Cooling Remended Installation: Cooling and Humidity Control Models 4 Heads Min. Installation Height 3 to 6 ft (0.9 to 1.8 m) Spacing Between Foggers 3 to 10 ft (0.9 to 3 m) Spacing Between Laterals 5 to 15 ft (1.5 to 4.6 m) COOLING: System Design Considerations A ventilation system is necessary to produce a cooling effect. If dry air is not introduced into the greenhouse as the Fogger cycles on and off, temperatures could rise along with humidity levels. Most fogging systems used for cooling release droplets for a very short time, with approximately 10 seconds between each round of fogging. The duration of a fogging event depends on the air velocity inside the greenhouse. The type of ventilation system installed determines the velocity. In most locations, the ventilation system should introduce dry air around 20 times per hour in order to maximize the cooling effect. Fogging Duration: Cooling Air Velocity Interval between Fogging* Duration of Fogging* 0.10 m/s 10 seconds 1-2 seconds 0.50 m/s 10 seconds 3-5 seconds 1.0 m/s 10 seconds 10 seconds *The duration of fogging and the intervals between fogging events need to be modified according to local conditions. The timing provided is just a starting point. The timing provided is based on the typical 4-way fogger installation. GENERAL GUIDELINES: Cooling & Humidity Control Mount Foggers as high as possible Install drops perpendicular to the lateral line Avoid spraying against roof or greenhouse structure 120-140 mesh filtration remended 4-Way Fogger units should be placed at 45 angles to one another. 3

Humidification Fogger Typical Installation for Humidfication or Cooling HUMIDIFICATION: System Design Considerations Some greenhouse plants will suffer serious damage if humidity levels drop below 30% inside a greenhouse. If more humidity is needed, the greenhouse s ventilation system can be turned off. Determining how often foggers should be on, as well as the amount of time between fogging events, depends on the desired level of relative humidity. In general, systems used to increase humidity run for a very short amount of time, with the duration of fogging ideally lasting 1 to 3 seconds. A controller can help manage the necessary interval between fogging events. Fogging Duration: Humidification Humidity Interval between Fogging Duration of Fogging 30-40% 60 seconds 1 second 40-50% 90 seconds 1 second 50-60% 120 seconds 1 second *The duration of fogging and the intervals between fogging events need to be modified according to local conditions. The timing provided is just a starting point. For crops that are not sensitive to wetting, the duration of fogging can be extended or the interval between events can be shortened. The timing provided is based on the typical 4-way fogger installation. 4

Fogger Propagation PROPAGATION: System Design Considerations Compared to cooling and humidification, propagation generally requires more foggers spaced closer together. GENERAL GUIDELINES: Propagation For wide benches up to 8 ft (2.4 m) in width, install two lines of Foggers equally distanced from the center of the bench to achieve a more uniform application Do not install Fogger lines more than one foot (0.3 m) from the edge of a bench 120-140 mesh filtration remended Remended Installation: Propagation Models Installation Height 4 Heads *Above the plant 1.5 to 2.5 ft (0.5 to 0.8 m) Spacing Between Foggers 3 ft (0.9 m) For propagation, mount the Fogger 1.5 to 2.5 feet (0.5 to 0.8 m) above the bench with 3 feet (0.9 m) spacing between heads. 5

Components Regulators COMPONENTS: Pressure Regulators Recognizing the importance of maintaining correct system pressure and uniform distribution, Senninger offers various models of reliable pressure regulators to meet specific flow and installation requirements. Senninger regulators maintain a constant preset outlet pressure with varying inlet pressures, which alleviates pressure differences that can cause an applicator s area of coverage to change. Flow Range 0.1 7 gpm (23 1590 L/hr) Preset Operating Pressure 10 40 psi (0.69 2.76 bar) Maximum Inlet Pressure 80 120 psi (5.52 8.28 bar) Inlet Sizes ¾" F hose, ¾" NPT (F) Outlet Sizes PRLG PRL PSR PMR-MF 0.1 8 gpm (23 1817 L/hr) 6 45 psi (0.41 3.10 bar) 100 150 psi (6.90 10.34 bar) ¾" NPT (F), ¾" F hose 0.5 15 gpm (114 3407 L/hr) 6 50 psi (0.41 3.45 bar) 100 135 psi (6.89 9.31 bar) ¾" NPT (F) 2 20 gpm (454 4542 L/hr) 6 60 psi (0.41 4.14 bar) 100 150 psi (6.90 10.34 bar) ¾" NPT (F), 1" NPT (F), 1" F BSPT ¾" M hose, ¾" NPT (M) ¾" NPT (F) ¾" NPT (F) ¾" NPT (F), 1" NPT (F), 1" F BSPT

Made in U.S.A. 16220 E. Highway 50, Clermont, FL 34711 Phone (407) 877-5655 Fax (407) 905-8249 International Fax (407) 905-8239 Website: senninger. E-mail: info@senninger. 14 FIG 12 MS782