Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Similar documents
Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

360º Surface Mount Ceiling PIR Light Controller

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

60W Multi PIR Bulkhead

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

5W LED Energy Saver PIR Bulkhead

360 Surface Mount Ceiling PIR Light Controller

360 Ceiling PIR Light Controller

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

"Options" Sensor Module

BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

High Frequency Sensor

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Programmable Security Light Switch

Security Light Transmitter

CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Emergency Assist Alarm Kit Single Zone

Digital Room Thermostat with Night Set-back

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

Installation & Operating Instructions

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

Compact Movement Activated Sensor Installation Instructions

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

Battery Powered Electronic Programmable Room Thermostat

Professional, Rewireable, Linkable LED Lighting

Cat. No TPT44. Installation & Operating Instructions

Electronic Frost Thermostat

USER GUIDE MOTORISED LED FLOOD LIGHT CAN WE HELP?

Electronic Room Thermostat Cat. No. TRT030

LED Lighting. Solutions

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

Safety! Seasonal INSIDE THIS ISSUE. Small and Powerful LED lighting Energy Saving without compromise.

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

LED Lighting. Solutions

Motion tracking. sensor led light. Installation & operating manual NIGHTWATCHER. Model no: nw1200x

PRODUCT INFORMATION. Uses tough, high quality PC diffuser, resistant to fracture and to ultraviolet light to limit discolouring.

LED Lighting Solutions

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Super. Bright. Lumens! Super. Slim!

Pie Warmer. Instruction manual. Model: GF454-A/GF455-A

PMCSF6 OCCUPANCY SENSOR

Chime Receiver E-996 INSTALLER GUIDE. SF-DCC-RX.qxd 13/04/ :30 Page 1

Installation and Safety Instructions Cone Wall Light with PIR Stainless Steel Model: S083S

Motion Sensor. Specifications

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

, ,

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

Ceiling PIR HS presence detector. Product Guide. Overview. Features

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

LPC3BSP65 & LPC3BDP65

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

LPCMPIRM65 & LPCMPIRDSI65

1. Basic safety information 3 2. Proper use 3

CERAMIC HEATER MODEL NO: DEVIL 350B 230V/110V OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & ORIGINAL INSTRUCTIONS GC ISS 1

Heated Display. Instruction manual. Model: CW147 / CW148

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Integrated PIR detectors

High bay PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Spiral Dough Mixer. Instruction manual. Model: CP821

Product Guide. Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

µdim Microwave Sensors User Manual

OWNERS INSTRUCTION MANUAL

PRODUCT DATA AND INSTALLATION SHEET MWS5-SA STAND ALONE MINIATURE CEILING MOUNTED MICROWAVE PRESENCE DETECTOR

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

High bay PIR presence detector 1-10V dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EBDSPIR-PRM-2CH, EBDSPIR-PRM-2CH-NC

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

KingShield. - Occupancy Detectors NEW. For complete Lighting Control... ORION RANGE. P High performance for optimum switching of all types

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

SHORT WAVE INFRARED PANEL DRYER

INSTALLATION & USER INSTRUCTIONS

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

PPAD-C-230V. Ceiling PIR presence/absence detector. Product Guide. Overview. Features

FMH Range Hoods. Installation, Operation & Maintenance Instructions

SWITCHLITE MRE SLD MAN SWITCHLITE MRE SLD IP55

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

LED Sensor Floodlight AZPOSE XL-S

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Transcription:

Model: PDSM1500 Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

Considerate Lighting pollution bythe incorrectly installing a unit an or area Please be caused aware of annoyance over-lighting over-lighting an area can be limited by carefully can cause to your immediate neighbours. Light considering the location and position of your unit pollution caused by incorrectly installing a unit or 1. Introduction befo re installation. The light spread on halogen over-lighting an area can be limited by all carefully floodlights can reduced by angling the floodlight The PDSM1500 utilises passive infrared technology toof detect heat radiation of considering thebe location and position your unit downwards on the mounting bracket. This will also before installation. lightthe spread onlighting all halogen moving human bodies. UponThe detection, attached load will illuminate concentrate the light on your property and limit the floodlights can be reduced by angling the floodlight for a user-determined time period. An integral daylight sensor ensures all day or potentialinconvenience of thebracket. light shining intoalso your downwards on the mounting This will night-only operation. neighbours windows etc. concentrate the light on your property and limit the Please seeinconvenience Selectinga Location for information potential of the light shining intoon your choosing the optimum locationfor any security light neighbours windows etc. controlled by this unit. Please see Selecting a Location for informationon choosing the optimum location for any security light B A controlled Side View by this unit. A B Side View 3m 3m 1 More sensitive More sensitive 3m detection Up topresence 3m Presence Detection 9m 3m Motion detection Up topresence 10m Motion Detection detection Less sensitive 9m Top View Motion detection 360 Top View 360 Less sensitive 2 2

CC C to to to or or or Lux Time On Time On Time On Time On ea ea ea Lux Dusk/Dawn Lux Lux Dusk/Dawn Dusk/Dawn Dusk/Dawn setting setting D D D 2 2 2 3 3 Mains Mains Supply Mains Supply IN Supply IN IN e e etive tive tive EE E Connect Earth wire Connect Earth wire to wall box Earth terminal Connect Earth wire to wall box Earth terminal to wall box Earth terminal LL L N N N L1 L1 L1 Switched Switched Load Switched Load OUT Load OUT OUT Wall box Wall box Wall box

2. Parts Included PIR Sensor unit. Instruction manual. Please keep safe for future reference. Accessory Pack. Includes cable clamp wiring cover and 2 x screws. 3. Tools & Parts Needed Terminal or Electricians screwdriver. Small philips screwdriver. Wire cutters. Suitable mains interconnect cable. This product is suitable for indoor use only. 4. Selecting a Location The motion detector has a number of detection zones, at various vertical and horizontal angles as shown (see diagram A). 3 A moving human body needs to cross/enter one of these zones to activate the sensor. The best all-round coverage is achieved with the unit mounted at the optimum height of 3m. Careful positioning of the sensor will be required to ensure optimum performance. See diagram A detailing detection range and direction. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS (see diagram B). Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area (extractor fans, tumble dryer exhausts etc.) including opposite any other light sources such as other security lights. Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions. During extreme weather conditions the motion sensor may exhibit unusual behaviour. This does not indicate a fault with the sensor. Once normal weather conditions return, the sensor will resume normal operation.

5. Installation IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation. All fittings should be installed by competent person in accordance with IEE Wiring Regulations (BS7671) Do not attempt to install if you are suffering from nausea or dizzy spells or on medication with similar side effects. If in any doubt, consult a qualified electrician. After choosing a suitable location (see previous section) install the unit as follows: The unit is suitable for connection to a 230 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1.5 sq. mm gauge is used. An isolating 4 switch should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes. This product can be fitted to standard 16mm UK back boxes.

6. Connection Switch off the main power supply or wall switch. Connect the mains supply cable Live core (brown) to L and Neutral core(blue) to N terminal. Connect the lighting cable Neutral core (blue) to the same N terminal and Lighting Live core (brown) to the L1 terminal on the unit (see diagram D):NEUTRAL (Blue) LIVE (Brown) LIVE (Brown) N L1 Load L Connect the Earth wire (Green/yellow) to the Earth terminal on wall box. When wiring is complete, set the two adjustment controls on the side of the unit (diagram C) to the following positions: TIME Fully anti-clockwise (Test Mode). 5 DUSK Fully clockwise. Fit the sensor unit to ceiling wall box and secure it with two fixing screws provided.

7. Setting up Walk Test Procedure TIME Fully anti-clockwise (Test Mode) DUSK Fully clockwise The unit will now operate during daytime as well as at night, illuminating the lamp for approx. 5 seconds each time. This allows testing to be carried out to establish whether the sensor is covering the required area. The lamp will immediately illuminate as the unit goes through its warm-up period. After approximately 1 minute the lamp will extinguish. Try to remain outside the detection area during the warm-up period. Walk around the sensor to establish the detection area. The sensor will detect within an approximately 9 metre diameter circle from the centre of the sensor location with a 3m ceiling. As you cross a detection zone the lamp will illuminate. 6 Now stand still until the lamp extinguishes (this should take approx. 5 seconds). Start moving again after 2 seconds. As you cross each zone the lamp will illuminate. Repeat the above, walking at various distances and angles to the unit. This will help you to confirm the detection pattern. Setting Up for Automatic Operation When walk tests are complete, the unit can be adjusted for automatic operation: The TIME setting controls how long the unit remains illuminated following activation & after all motion ceases. The Time control knob at fully anti-clockwise is Test Mode, slightly adjust to above the T is minimum time approx. 1 min, whilst the maximum time (fully clockwise) is approx. 30 minutes. Set the control to the desired setting between these limits.

The DUSK control determines the level of darkness required for the unit to start operating. The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise. The unit will now start operating at dusk. If you require the light to activate earlier, wait until the ambient light level reaches the level of darkness at which you wish the lamp to become operative, SLOWLY(a small step at a time) rotate the control in a clockwise direction until a point is reached where the lamp illuminates in response to a hand moving below the unit. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite bright), adjust the control slightly anti-clockwise. If the unit starts to operate too late (ie. dusk), adjust the control slightly clockwise. 7 Continue to adjust until the unit operates as desired. Once the unit is set up as desired, ease the unit back into position under spring pressure.

8. Troubleshooting Guide Problem Solution Lamp stays ON all the time at night. Cover PIR lens with a thick cloth. If the light turns out, check detection area for heat or reflective source. If the light stays on, check wiring. See Connection. PIR keeps activating for no reason (at random). Turn off at the isolation switch. Turn back on again after 30 seconds. Leave for approximately 15 minutes. PIR sensor will not operate at all. Check that the power is switched ON at the power supply or isolation switch. If light activates, check area for false activation from heat, wind or reflective source. Turn OFF the power to the unit and check the wiring connections. 8 Check the lamp. If the lamp has failed, replace. Ensure that the lamp is seated correctly in the lampholder. Please note that the unit will not detect through glass. (e.g. in a glazed porch). The PIR sensor will not operate at night. The level of ambient light in the area may be too bright to allow operation at the current DUSK setting. During the hours of darkness, adjust the DUSK control slowly clockwise until the lamp illuminates. Refer to previous section for more details. Unit activates during the daytime Adjust the DUSK Control setting anti-clockwise to lower the level of ambient light required for activation.

9. Technical Specifications Motion Detection Range: Up to 10 metres diameter (4.5m Radius) at mounting height of 3m Presence Detection Range: Up to 3 metres diameter (1.5m Radius) at mounting height of 3m Detection Angle: 360º Power Supply: 230 V AC ~ 50Hz Maximum Switchable Load: 1500W Halogen or Fluorescent/low energy lighting. Not suitable for discharge lighting. 250W fan load 9 Time On Adjustment: 1 minute 30 minutes Dusk Level Adjustment: Day & night or night only operation Environmental Protection: IP55

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. 10

HELPLINE 020 8450 0515 or email helpline@timeguard.com For a product brochure please contact: Designed in the U.K. 67-058-426 Zerofour September 2011 Timeguard Limited. Victory Park, 400 Edgware Road, London NW2 6ND Sales Office: 020 8452 1112 or email csc@timeguard.com