Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Similar documents
Caledonian Flame Retardant Coaxial Cables

Caledonian Fire resistant Coaxial Cables

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (Multicore)

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape Armoured Power Cables (3 Cores)

Caledonian fire Resistant signal & Data cables

Flame Retardant Overall Screened Instrumentation Cables (multicore)

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Multi-Core Fire Resistant Cable

FIRE RESISTANT CABLES

PRODUCT CATALOGUE Norröna

BS /1000V XLPE Insulation LSZH Sheath Cables

SPECIAL ELECTRICAL AND OPTICAL CABLES

Photovoltaic Cables EN H1Z2Z2-K

High Performance LSZH Fire Resistant Cable

Catalogue. Instrumentation & Control Cables

Caledonian. FIREFLIX ire Resistant Coaxial Cables

Catalogue Telecommunication Cables INTRODUCCIÓN

Introduction.

Catalogue Power Cables

Firecel Safety Cables

Compact Module. Category 6A FTP Cabling System 1.1

S Low loss coax cables with foamed PE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Firetuf Cables ZERO HALOGEN, LOW SMOKE (0HLS ) CABLE

Core identification code. J-YY...BD Indoor Cable. J-YY...BD Indoor Cable. VDE 0815 Mutual capacitance. J-YY...BD Indoor Cable. Cu conductor 0.

Telecommunication Cables

Power Cables. Introduction 3 RV 4 RVMV 5 RVSV 6 RVFV 7. ELECWIRES 2 Page

Cable technology for highest safety requirements

Fire alarm cables. for highest safety requirements TRADITION INNOVATION PASSION

SAS Security and Alarm Safety Cables

THE INNOVATIVE CABLE PRODUCER INSTRUMENTATION CABLES FOR THE INDUSTRY - AND PLANT CONSTRUCTION

CATEGORY 6A FTP RJ45 SOLUTION

The Quality Connection. BETAflam Fire Resistant Safety Cables

fire resistant cables

Traction Cable Radox 3 GKW

INTRODUCTION. Our diverse range of world-class Specialty Insulated Wires and Cablesinclude: LV Cables -

Double insulated, electron-beam cross-linked, halogen free photovoltaic wire sunlight resistant. Single conductor, flame retardant insulation.

Table of Contents. TELE-FONIKA KABLE SA (DMCC Branch). 4 TELE-FONIKA Kable Group 6 FLAME-X 950 SERIES 1 11 FLAME-X 950 SERIES 2

OIL & GAS INDUSTRY OTHER INDUSTRIES

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

CMZH Low Smoke 0-Halogen Flame- Retardant Mass Transit Tag

BS EN :2004. Test On Electric And Optical Fibre Cables Under Fire Conditions. WF Report Number. Date: 14 th November 2008.

DNVGL-CP-0402 Edition February 2016

ZH Low Smoke 0-Halogen Flameretardant Identification Sleeves

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

OUR SOLUTION: YOUR CABLE. PRODUCTION OVERVIEW

PHOTOVOLTAIC CABLES. Photovoltaic Cable 2000V/1500V Photovoltaic Cable 2000V/1000V

Company Profile. We are dedicated to providing our customers competitive price and excellent service.

Total Fire Solutions. Includes BS 8519 and the updated BS :

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

Rolling Stock Cables.

FIRE PERFORMANCE CABLE

Single core cables with reduced wall thickness

DNVGL-CP-0399 Edition March 2016

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

Sensor and transducer cables

GCRG. Multi Loose Tube Cables Universal Indoor / Outdoor A/I-DQ(ZN)BH Improved Rodent Protection v7.0. Ordering Information.

GUCN. Central Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)(SR)H Full Rodent Protection v13.

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

CABLES FOR ALARM AND SAFETY SYSTEMS

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

IEC UNE DESIGN. 1. Conductor. 2. Insulation. Cross-linked polyethylene (XLPE) 3. Outer sheath. Flexible PVC, black colour.

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

AFUMEX LSX LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

HELKAMA. Optical Fibre Cables

AFUMEX LSX BASEC APPROVED LOW SMOKE ZERO HALOGEN SCREENED WIRING CABLES BS8436 PRODUCT DATASHEET & APPLICATIONS GUIDE KEY BENEFITS:

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

ENHANCED FIRE PERFORMANCE CABLE

MEDIUM VOLTAGE CABLES INSTRUMENTATION CABLES RUBBER CABLES FIRE RESISTANT CABLES

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

SHIELD TYPE MULTICONDUCTOR MULTIPAIR

STANDARDS INSTALLATION. Certificate No 077m

DNVGL-CP-0401 Edition February 2016

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

BS FP600 achieves the maximum 120 minute rating under the BS test conditions, which is required for fire fighting applications.

Tether and Umbilical Cables for Remotely Operated Vehicles

outdoor and indoor campus backbone, building backbone (riser) FDDI, Gigabit Ethernet and ATM Easy to install direct burial halogen-free

THE MYSORE UNIT OF RPG CABLES MANUFACTURES A RANGE OF INSTRUMENTATION CABLES

Duct Cable GYTS-144B1.3

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 28 ELEC. SAFETY & SECURITY SECTION CONDUCTORS AND CABLES FOR ELECTRONIC SAFETY AND SECURITY

UV RESISTANT ACCORDING TO HD 605 RULE

Shipboard & Offshore Cables

System Circuit integrity in the event of fire. Safety cables and systems from a pro. Cabling Solutions

POINT OBSTRUCTION CONTROLLER POC TOUCHSCREEN CONTROLLERS

Tratos Railway Cables

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

Overmoulded Cable Assembly Selector Guide

Havells Fire Survival Cables

The Quality Connection. Cable fire protection Flammability tests on ship and offshore cables

UNIKA Universal Cable Cable Specialist

FIRE RESISTANT CABLES FP200 GOLD

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Author Owner Issue Authority Name: Gordon MacKenzie Title: Senior Engineer Engineering Design and Standards

Flexible Power Cable DLO

Transcription:

ADDISON Flame Retardant RG59 B/U Coaxial cables Plain copper wire braid PE Solid Bare Copper PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design adapted to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABLE CONSTRUCTION Conductors: Copper clad steel, solid according to IEC(EN) 60228 class 1. Insulation: PE compound. Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30 C - +70 C Temperature range during installation (mobile state): -5ºC - +60ºC 134 Caledonian

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Minimum bending radius: 8 x Overall Electrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 66 Insulation resistance 67 nf/km >2000 Mohm.Km Shield coverage 95% DC resistance Inner conductor 158 Ω/km Outer conductor 9.0 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 7.4 2.26 100 10.7 3.26 200 15.7 4.79 400 22.7 6.92 500 25.7 7.84 600 28.7 8.75 860 34.8 10.61 1000 38.0 11.59 Return Loss Frequency(MHz) Return Loss (db) 30-300 MHz >31dB 300-600 MHz >28dB 600-900 MHz >24dB CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km FGD-RG59 B/U 0.58 ± 0.03 3.70 ± 0.10 m 120 x 0.15 6.20 60.3 300/500V Rated Voltage MIL-C-17 N Standard Flame Retardancy** NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 Reduced Fire Propagation** NF C32-070-2.2(C1) IEC60332-3-22/EN50266-2-4 ADDISON 135

ADDISON Flame Retardant RG59 B/U CWB/SWB/SWA Armoured Coaxial Cables RG59 B/U CWB/SWB/SWA PVC Outer Sheath Copper Braid Screen PE Insulation Copper Clad Steel/Bare Copper PVC Inner Sheath CWB/SWB/SWA AppliCAtion These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. StAnDARDS Basic design adapted to MIL-C-17 FiRE performance Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABlE ConStRUCtion Conductors: Copper clad steel or bare copper, solid according to IEC 60228 class 1. insulation: PE compound. overall Screen: Plain copper wire braid inner Sheath: Thermoplastic PVC compound. Armouring: CWB: Copper Wire Braid SWB: Steel Wire Braid SWA: Steel Wire Armour outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. physical AnD thermal properties temperature Range: -30 C - +75 C Minimum Bending Radius: 15 X Overall 136 Caledonian

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com ElECtRiCAl properties Impedance 75±5Ω Capacitance 67 nf/km Velocity ratio 66% Insulation resistance >2000 Mohm.Km Shield coverage 95% DC resistance Inner conductor 161 Ω/km Outer conductor 8.5 Ω/km AttEnUAtion Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) 50 7.4 2.26 100 10.7 3.26 200 15.7 4.79 400 22.7 6.92 500 25.7 7.84 600 28.7 8.75 860 34.8 10.61 1000 38.0 11.59 REtURn loss Frequency(MHz) Return Loss (db) 30-300 MHz >31dB 300-600 MHz >28dB 600-900 MHz >24dB ConStRUCtion parameters Cable Code Inner Conductor Insulation Outer Sheath Overall Weight Thickness Thickness mm mm mm mm kg/km RG59 B/U CWB 0.58 1.4 1.2 9.78 146 RG59 B/U SWB 0.58 1.4 1.2 9.78 114 RG59 B/U SWA 0.58 1.4 1.2 10.8 220 300/500V Rated Voltage MIL-C-17 N Standard Flame Retardancy** NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 Reduced Fire Propagation** NF C32-070-2.2(C1) IEC60332-3-22/EN50266-2-4 ADDISON 137

ADDISON Flame Retardant RG6 A/U Coaxial cables Tinned Copper Wire Braid PVC Outer Sheath Bare Copper Foam PE Insulation Al/polyester Foil or Al Foil Screen1 APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design adapted to MIL-C-17 FIRE PERFORMANCE 140 Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** Caledonian EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABLE CONSTRUCTION Conductors: Bare copper copper wire, solid according to IEC(EN) 60228 class 1. Insulation: Foamed PE compound. creen1: Aluminium/polyester or aluminium tape. creen2: Tinned copper wire braid. Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. Physical AND THERMAL PROPERTIES Temperature Range During Operation (Fixed State): -30 C - +70 C

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Temperature Range During Installation (Mobile State): -5 C - +60 C Minimum Bending Radius: 8 X Overall Electrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 82 Insulation resistance 54 nf/km >5000 Mohm.Km Shield coverage AL foil(100%)+al 70% DC resistance Inner conductor 23.1 Ω/km Outer conductor 31 Ω/km Attenuation Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Return Loss 50 5.0 1.5 100 6.4 1.96 200 9.2 2.8 500 14.5 4.4 600 15.9 4.9 800 17.7 5.4 1000 21.9 6.7 1350 24.9 7.6 1750 29.0 8.8 2050 33.1 10.1 2400 36.4 11.1 Frequency(MHz) Return Loss (db) 30-300 >28dB 300-600 >24dB 600-900 >22dB ADDISON 141

ADDISON CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km FGD RG6 A/U 1.02 4.57 ± 0.20 96 x 0.12 7.00 81.6 300/500V Rated Voltage MIL-C-17 N Standard Flame Retardancy** Reduced Fire Propagation** NF C32-070-2.1(C2) NF C32-070-2.2(C1) IEC60332-1-2/EN50265-2-1 IEC60332-3-22/EN50266-2-4 142 Caledonian

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com flame Retardant RG6 Quad shield coaxial cables RG6 Quad shield Al-maylar Screen Aluminium Wire Braid Screen Al-maylar Screen Aluminium Wire Braid Screen Solid Bare Copper Foam PE Insulation PVC Sheath Application These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. STANDARDS Basic design adapted to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABLE CONSTRUCTION conductors: 18AWG bare copper wire, solid according to IEC 60228 class 1. Insulation: Foam PE. screen1: Aluminium-maylar. screen2: Aluminium wire braid. screen3: Aluminium-maylar. screen4: Aluminium wire braid. Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. PhysIcal and THERMAL PRoPERTIES ADDISON 143

ADDISON Temperature Range: -30 C - +75 C Minimum Bending Radius: 815 X Overall Electrical Properties AWG 18 Conductor mm 1.0 Impedance Ω 75+/-5 Attenuation@100MHz db/100m 6.9 Attenuation@200MHz db/100m 9.0 Attenuation@300MHz db/100m 11.8 Attenuation@400MHz db/100m 13.1 Attenuation@500MHz db/100m 15.4 Attenuation@900MHz db/100m 21.5 Attenuation@1700MHz db/100m 29.4 Capacitance pf/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 21.4 Shield DCR Ω/km 7.5 Inductance μh/m 0.32 Time Delay ns/m 4 CONSTRUCTION PARAMETERS Cable Code Inner Conductor Insulation Sheath Overall Weight Thickness Thickness mm mm mm mm kg/km FGD RG6 A/U CWB 1.0 1.8 1.2 10.8 181 FGD RG6 A/U SWB 1.0 1.8 1.2 10.8 177 FGD RG6 A/U SWA 1.0 1.8 1.2 11.8 267 144 Caledonian

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com Flame Retardant RG11 A/U Coaxial Cables Plain Copper Wire Braid Screen PE Tinned Copper Binder PVC Outer Sheath APPLICATION The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments. STANDARDS Basic design adapted to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABLE CONSTRUCTION Conductors: Tinned copper wire, stranded according to IEC(EN) 60228 class 2. Insulation: Low density PE. Overall Screen: Plain copper wire braid Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance ADDISON 145

ADDISON standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. Physical AND THERMAL PROPERTIES Temperature Range During Operation (Fixed State): -30 C - +70 C Temperature Range During Installation (Mobile State): -5 C - +60 C Minimum Bending Radius: 8 X Overall Electrical Properties Impedance 75±5Ω Capacitance Velocity ratio(%) 66 Insulation resistance Shield coverage 97% DC resistance Inner conductor Outer conductor Attenuation 67 nf/km >2000 Mohm.Km 20.5 Ω/km 4.5 Ω/km Frequency(MHz) Attenuation (db/100 m) Attenuation (db/100ft) Return Loss 50 4.2 1.28 100 6.2 1.89 200 9.3 2.84 400 13.8 4.21 500 15.5 4.73 600 17.1 5.21 860 20.1 6.13 1000 23.4 7.13 Frequency(MHz) Return Loss (db) 30-300 MHz >30dB 300-600 MHz >27dB 600-900 MHz >25dB 146 Caledonian

Caledonian Flame Retardant Coaxial Cables www.caledonian-cables.co.uk www.addison-cables.com CONSTRUCTION PARAMETERS Cable Code Conductor Insulation Screen No.x Overall Approx. Weight mm mm No. x mm mm kg/km FGD RG11 A/U 7 x 0.40 7.25 ± 0.18 192 x 0.18 10.3 ± 0.18 150 300/500V Rated Voltage MIL-C-17 N Standard Flame Retardancy** NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 Reduced Fire Propagation** NF C32-070-2.2(C1) IEC60332-3-22/EN50266-2-4 ADDISON 147

ADDISON Flame Retardant RG11 A/U CWB/SWB/SWA Armoured Coaxial Cables PVC Outer Sheath Tinned Copper Braid Aluminium+polyester/Aluminium Tape PE Solid Bare Copper PVC Inner Sheath Tinned Copper Drain Wire Braid or Wire Armoured APPLICATION These 75Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments. STANDARDS Basic design adapted to MIL-C-17 FIRE PERFORMANCE Flame Retardance (Single Vertical Wire Test)** Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* EN 60332-3-22 (cat. A); IEC 60332-3-22; BS EN 60332-3-22; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design. CABLE CONSTRUCTION Conductors: 14AWG solid bare copper. Insulation: Low density PE compound. Screen1: Aluminium/polyester or aluminium tape. Screen2: Tinned copper braid. Inner Sheath: Low smoke and halogen-free polyolefin, coloured black. Armour: cwb: copper Wire Braid swb: Steel Wire Braid swa: Steel Wire Armour Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance 148 Caledonian

Caledonian Flame Retardant Optic Fiber Cables www.caledonian-cables.co.uk www.addison-cables.com standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request. Physical AND THERMAL PROPERTIES Temperature range during operation (fixed state): -30 C - +75 C Minimum bending radius: 15 x Overall Electrical Properties AWG 14 Conductor mm 1.6 Impedance Ω 75+/-5 Attenuation@100MHz db/100m 4.5 Attenuation@270MHz db/100m 7.6 Attenuation@540MHz db/100m 10.8 Attenuation@750MHz db/100m 12.8 Attenuation@1000MHz db/100m 14.8 Capacitance pf/m 53.5 Velocity of Propagation % 83 Conductor DCR Ω/km 8.5 Shield DCR Ω/km 12.1 Inductance μh/m 0.32 Time Delay ns/m 4 CONSTRUCTION PARAMETERS Cable Code Inner Conductor Insulation Thickness Sheath Thickness Overall Weight mm mm mm mm kg/km FGD RG11 A/U CWB 1.6 2.7 1.7 15.2 349 FGD RG11 A/U SWB 1.6 2.7 1.7 15.2 344 FGD RG11 A/U SWA 1.6 2.7 1.7 16.2 468 300/500V MIL-C-17 N Rated Voltage Standard Flame Retardancy** NF C32-070-2.1(C2) IEC60332-1-2/EN50265-2-1 Reduced Fire Propagation** NF C32-070-2.2(C1) IEC60332-3-22/EN50266-2-4 ADDISON 149