Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

Similar documents
Solar air heater duct having triangular protrusions As roughness elements on absorber plate

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

A Review on Comparative Study of Thermal Performance of Artificially Roughened Solar Air Heaters

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Assistant Professor),( Professor), Department of Mechanical Engg., B.I.T. Sindri 3. Professor, Department of Mechanical Engg., N.I.T.

Design and Fabrication of Solar Air Heater to Increase Heat Transfer Rate using Artificial Roughness

THERMOHYDRAULIC PERFORMANCE OF AN EQUILATERAL TRIANGULAR DUCT WITH ARTIFICIAL ROUGHNESS USED IN SOLAR AIR HEATER

Thermo-Hydraulic Performance Evaluation Using W-Discrete Rib in Solar Air Heater

Experimental Investigations on Packed Bed Solar Air Heater

Design and Thermal Analysis of Solar Plate Collector with and Without Porous Medium

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

Greek Symbol η collector efficiency Rim angle

Performance analysis of overlapped solar air heater using CFD

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

Thermal Analysis of Concentric Tube Heat Exchanger Using Louvered Strip Inserts

THE PERFORMANCE STUDY OF A SOLAR FLAT PLATE TYPE AIR COLLECTOR WITH NATURAL AND FORCED CONVECTION

Performance Evaluation of Hybrid Solar Water Heating System Using Wire Screen Packed Solar Air Heater

1, 2

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Performance Analysis for the Double- Pass Solar Air Collector with and Without Porous Media

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Performance Study of Triple Concentric Pipe Heat Exchanger

2. HEAT EXCHANGERS MESA

Global Journal of Engineering Science and Research Management

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET) AN EXPERIMENTAL STUDY OF HEAT TRANSFER IN A CORRUGATED PLATE HEAT EXCHANGER

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Experimental Investigation of a Brazed Chevron Type Plate Heat Exchanger

6340(Print), ISSN (Online) TECHNOLOGY Volume 3, Issue (IJMET) 2, May-August (2012), IAEME

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

Jurnal UMP Social Sciences and Technology Management Vol. 3, Issue. 3,2015

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

Performance Analysis of Solar Air Heater Using Three Wire Mesh

CFD Analysis of a 24 Hour Operating Solar Refrigeration Absorption Technology

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

DESIGN AND ANALYSIS OF PIPE HEAT EXANGERS WITH INSIDE FINS

International Journal of Advance Research in Engineering, Science & Technology SOLAR HUMIDIFIER

ENSC 388: Engineering Thermodynamics and Heat Transfer

FABRICATION OF REFRIGERANT FLOW RATE WITH SPIRALLY COILED CAPILLARY TUBE

EXPERIMENTAL ANALYSIS OF TIP CLEARANCE AND CHORD LENGTH FOR OPTIMUM DESIGN OF AXIAL FLOW FAN IN AIR COOLED HEAT EXCHANGER

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

FLIGHT UNLOADING IN ROTARY SUGAR DRYERS. P.F. BRITTON, P.A. SCHNEIDER and M.E. SHEEHAN. James Cook University

Natural Convection Heat Transfer Augmentation from Heat Sinks using Perforated Fins: A Review

a Heat Exchanger using FEA Tool

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Experimental analysis of condensation heat transfer enhancement of steam at low pressures using modified twisted tape insert

MAL-DISTRIBUTION MODEL OF HEAT EXCHANGERS IN MICRO CHANNEL EVAPORATOR

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Modified Air Cooler with Split Cooling Unit

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Investigation of a Novel Ceiling Panel for Heat and Moisture Control in Buildings

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

IMPROVE THE EFFICIENCY OF HEAT EXCHANGER IN OIL COOLER.

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Experimental Investigation of Heat Transfer Enhancement from Waveform Pin-Fins

PERFORMANCE OF EARTH TUBE HEAT EXCHANGER COOLING OF AIR A REVIEW

Performance of solid desiccant-based evaporative cooling system under the climatic zones of India

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance and Evaluation of Pop Can Solar Dryer for Batch Products

CFD Analysis of temperature dissipation from a hollow metallic pipe through circular fins using Ansys 14.5

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

A REVIEW ON HEAT EXCHANGER

Design, Development and Experimental Investigation of Volumetric Air Receiver

Design and Experimental Studies on Modified Solar Dryer

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Solar Drying Techniques And Performance Analysis: A Review

Simulation on Counter Flow Heat Exchanger for Indirect Evaporative Cooling Applications Avinash Pandey 1 Dr. P.K.Jhinge 2

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

STUDY ON TEMPERATURE, RH AND AIR FLOW VELOCITY DISTRIBUTION INSIDE THE GREENHOUSE EFFECT SOLAR DRYER

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Compression of Fins pipe and simple Heat pipe Using CFD

Design and Development of Water Cooled Condenser for Domestic Refrigerator

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

DESIGN AND ANLYSIS OF MODIFIED HYBRID SOLAR SYSTEM USING NANO FLUIDS

Heat Transfer Enhancement in Shell and Tube Condenser

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Experimental Analysis of Heat Exchanger and Simulation of Result Using Solid Works Software

Transcription:

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography Amit Kumar Gautam¹, Dr. J. L. Bhagoria² ¹M.Tech. Scholar, Mechanical Engineering, ²Professor, Mechanical Engineering Department MANIT Bhopal (M.P.) India Abstract :The actual aim of this study is to enhancement of the transfer of heat from a double inclined artificially roughened ribbed rectangular duct, by using Liquid Crystal thermography technique. This artificially roughened rectangular duct has aspect ratio of 5.0. The investigation has relative roughness height (e/dh) of 0.034, angle of attack of fluid flow (α) of 60 0 for a fixed relative pitch of 10 and Reynolds number (Re) range of 4000 12000. In this study Liquid Cristal Thermography (LCT) is used to determine the heat transfer distribution on the ribbed surface. Results has been compared with those of the smooth duct on similar flow conditions to determine the enhancement in heat transfer coefficient. Keywords Solar Air Heater, Heat Transfer, Artificial Roughness, Liquid Cristal Thermography 1. Introduction The energy demand is rise incessantly and speedily, and it's not possible to satisfy the long run demand with the current on the market exhaustible energy sources. So, the technology is that specialize in harnessing new and renewable sources of energy. Further, the traditional energy sources area unit inflicting associate threat risk to the earth life. The utilization of alternative energy is intelligent possibility for the utilization of human beings that is available freed from value, in abundant and may be a clean supply for numerous applications. In this study heat transfer coefficient of rib roughened square channel is measured by using liquid crystal thermography technique. LCT is a optical thermal visualization technique in which thermo chromic liquid crystal (TLC) response to temperature. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2384

Thermo chromic liquid crystals (TLC) are materials that change their reflected colour as a function of temperature when illuminated by white light. More artificial roughened element geometries over the duct has been investigated by many authors in the last few years. Sandeep Jaiswal, K. R. Aharwal (2015) done his investigation on Transient Analysis of Transverse Ribbed Rectangular Duct by Liquid Crystal Thermography and it has been observed that the enhancement of heat transfer for proposed rib roughness arrangement. Momin, J.S. Saini, S.C. Solanki (2002) shows in his work, results of an experimental study of the effect of geometrical parameters of V-shaped rib elements on transfer of heat and fluid flow characteristics of an artificial roughned rectangular duct of solar air heater with absorber plate having V-shaped ribs on its underside has been reported. Sahu and Bhagoria (2005) was done performance analysis of solar air heater duct having straight discrete ribs P/e= 6.67-20, e/d= 0.0338, AR= 8, α= 90 0, Re= 3000-12000 with this value of parameters maximum value of Nusselt number was reported. 2. The Experiment a. Apparatus In this apparatus the main components are heater, rectangular test section, orifice meter, U tube manometer, illuminating light system, camera, data logger, computer, centrifugal blower and motor. Fig.1 Schematic Diagram of Experimental setup 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2385

The test section is a rectangular channel with AR= 5.0, width= 200mm, height= 40mm and a length= 1500mm, constructed with 12mm thick Cast Acrylic sheet. Heater is used to heat up the incoming air. Toshiba s 3CCD camera is used to capture the thermal images. 20w LED light source is used as a illuminating system. b. Roughness Geometry Roughness geometry parameters are Range of Reynolds number (Re) is 4000-12000, Relative roughness pitch (P/e) =10, Angle of attack (α) =60, Diameter of rib (e) is 1mm, Width of plate (w) is 200mm, Length of plate (L) is 1500mm and Relative roughness height (e/d) has been chosen 0.034. Fig. 2 Actual image of 60 double inclined ribs geometry Fig. 3 Schematic diagram of double inclined (60 degree) rib geometry 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2386

c. Experimental Procedure Liquid Cristal Thermography technique is used to measure temp. distribution in the duration of heat transfer from hot air to the test surface. Apply the thermo chromic liquid crystal sheet on to the surface of the test section in the duct. Liquid crystal sheets used in this experiment is in the temperature range of 55 C to 60 C. The test section initially must be kept at constant temperature level and after that quickly exposed to a high temperature flow. Maintain the temperature with in the range of liquid crystal sheet. When air is maintain with in the range of LC sheet, then air is allow to pass through the main test section and during this bypass line is closed by operating three way valve. Measure and record the temperature response of LC sheet. Temperature response of LC sheet is captured by 3CCD Camera with suitable illuminating light source system and the temperature is recorded by data logger. After recording temperature and colour image of the LC sheet in different points of test section, we made a relationship between colour and temperature. Now the colour response of the LC sheet and their variation with temperature can be used to get exact temperature of any point of the test section. d. Data Reduction The convective heat transfer coefficient is determined by using following relationship. Heat Transfer Coefficient : Nusselt Number : h = Qa / Ap (Tpav-Tfav) Nu = h x Dh / k Reynolds Number : Re = V Dh /υ where, Qa is a heat gained by air, Ap is a surface area of the rectangular plate, υ is a kinematic viscosity of air at Tfav, Dh is a hydraulic diameter of duct, k is a thermal conductivity of air. 3. Results and Discussion Calibration of liquid crystal sheet of specific band width of temperature range 55 0 C to 60 0 C is performed and after that calibration comparison of colour images hue value with that graph we can calculate exact temperature on the test surface. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2387

m ₁ m ₂ m ₃ m ₄ m ₅ Fig.4 Actual thermal images of ribs in different mass flow rate S. m (kg/s) V (m/s) Re Nu No. 1. 0.00739 1.27 3490 5.91 2. 0.01044 1.80 4928 7.94 3. 0.01279 2.21 6032 9.74 4. 0.01476 2.55 6956 10.54 5. 0.01648 2.86 7749 12.31 Table.1 Results for 60 inclined ribs 80 70 60 50 Qair 40 30 20 10 0 60 rib Smooth plate 0 2000 4000 6000 8000 10000 Re Fig. 5 comparison between Qair and Re for 60 ribs and smooth plate 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2388

8 7 6 5 h 4 3 2 1 0 60 rib Smooth plate 0 2000 4000 6000 8000 10000 Re Fig. 6 comparison between h and Re for 60 ribs and smooth plate 14 12 10 8 Nu 6 4 2 0 60 rib Smooth plate 0 2000 4000 6000 8000 10000 Re Fig. 7 comparison between Nu and Re for 60 ribs and smooth plate 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2389

4. Conclusions Experimental test is performed with the liquid crystal thermography technique for the selected design parameters of artificial rib geometry to find the local Nusselt number and this results of artificial roughened duct has been compared with the smooth duct on similar flow condition to determine heat transfer. It is observed that the enhancement of heat transfer for proposed rib geometry is better than the smooth duct. References [1] Aharwal K.R., B. K. Gandhi, J.S. Saini, (2008) Experimental investigation on heat-transfer enhancement due to a gap in an inclined continuous rib arrangement in a rectangular duct of solar air heater, Renewable Energy 33, 585 596. [2] Sandeep Jaiswal, K. R. Aharwal (2015) An Experimental Investigation of Heat Transfer in A Discrete Rib Roughened Channel Volume 5, Issue 6, June 2015 [3] Sandeep Jaiswal, K. R. Aharwal (2015) Transient Analysis of Transverse Ribbed Rectangular Duct by Liquid Crystal Thermography Vol. 4 Issue 04, April-2015 [4] Yadav AS, Bhagoria JL. A CFD based heat transfer and fluid flow analysis of a conventional solar air heater. J Eng Sci Manag Educ 2013;6(2):137 46. [5] ASHRAE Standard 93. Method of testing to determine the thermal performance of solar collectors. Atlanta: American Society of Heating, Refrigeration and Air Conditioning Engineers; 2003. [6] Momin AME, Saini JS, Solanki SC. Heat transfer and friction in solar air heater duct with v-shaped rib roughness on absorber plate. Int J Heat Mass Transf 2002;45:3383 96. [7] Bhagoria JL, Saini JS, Solanki SC. Heat transfer coefficient and friction factor correlations for rectangular solar air heater duct having transverse wedge shaped rib roughness on the absorber plate. Renew Energy 2002;25:341 69. [8] Saini RP, Verma J. Heat transfer and friction factor correlations for a duct having dimple-shaped artificial roughness for solar air heaters. Energy 2008;33:1277 87. [9] Varun RP, Saini, Singal SK. Investigation of thermal performance of solar air heater having roughness elements as a combination of inclined and transverse ribs on absorber plate. Renew Energy 2008;33:1398 405. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2390

[10] Layek A, Saini JS, Solanki SC. Effect of chamfering on heat transfer and friction characteristics of solar air heater having absorber plate roughened with compound turbulators. Renew Energy 2009;34:1292 8. [11] Karmare SV, Tikekar AN. Experimental investigation of optimum thermo-hydraulic performance of solar air heaters with metal rib grits roughness. Sol Energy 2009;82:6 13. [12] Aharwal KR, Gandhi BK, Saini JS. Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate. Int J Heat Mass Transf 2009;52:5970 7. [13] Bopche SB, Tandale MS. Experimental investigations on heat transfer and frictional characteristics of a turbulator roughened solar air heater duct. Int J Heat Mass Transf 2009;52:2834 48. [14] Kumar A, Bhagoria JL, Sarviya RM. Heat transfer and friction correlations for artificially roughened solar air heater duct with discrete W-shaped ribs. Energy Convers Manag 2009;50:2106 17. [15] Varun A, Patnaik, Saini RP, Singal SK, Siddhartha. Performance prediction of solar air heater having roughened duct provided with transverse and inclined ribs as artificial roughness. Renew Energy 2009;34:2914 22. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 2391