FDCL221-Ex Line adapter (Ex)

Similar documents
FDCL221-M Multi line separator module

Multi line separator module

OOH740-A9-Ex Multi-sensor fire detector

FDOOT241-A9-Ex Multisensor fire detector

FDCIO223 (ES 45) Transponder

OOH740-A9-Ex Multisensor fire detector

Input module, input/output modules

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Input module, input/output module

Output module (230 V)

Mimic display driver, LED ribbon cable

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

ASA linear smoke detector

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DF1101-Ex Infrared flame detector

FDBZ290 Air sampling smoke detection kit

FC724 Fire control panel

FC722 Fire control panel

Interbases. Sinteso FDSB221, FDSB228, FDSB229

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

FC724 Fire control panel

FC722 Fire control panel

FC723 Fire control panel

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Fire control panels FC726 FC726-XA

FDBZ290 Air sampling smoke detection kit

FDCW241 Radio gateway Mounting

FDCL221 Line separator

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDA241, FDA221 Siemens ASD

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDOOT221, FDO221, FDT221

FC2020 Fire control panel

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

SWING radio fire detection system

DC1192 Input /Output module

OH720, OP720, HI720, HI722

DF1151-Ex Infrared flame detector

Fire control panel for modernization

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

FDOOT241-9, FDOOT241-A, FDO241, FDT241

FDA241, FDA221 Siemens ASD

Test units and accessories

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Fire control panels FC360

XC10 Extinguishing control panels

FDCI221, FDCIO221 Input module, input/output module Technical Manual

OOH740, OOHC740 Automatic fire detectors

Building Technologies. FDUL221 en Line tester operating instructions for electricians

DM1131 / DM1133 / DM1134 Manual call points

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Test units and accessories

DT1101A / DT1102A / DO110xA Automatic fire detectors

FC2040. Fire control panel. Sinteso. FS20 series, MP6

Test units and accessories

FDOOT241-A9-Ex Automatic fire detector Technical Manual

FDL241-9 Linear smoke detector Mounting Commissioning

FS20 Fire detection system

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

Sinteso TM product catalog.

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

FDCIO223 Input / output module (transponder)

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

Radio fire detection system

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

FDM273 Radio manual call point Mounting

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

XC10 combined fire detection and extinguishing control

IECEx Certificate of Conformity

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

FDS229 Alarm sounder with supplementary optical indication Technical Manual

XC10 combined fire detection and extinguishing control

CE110I. Piezoelectric accelerometer with integrated electronics. IECEx

FS720 Fire detection system (marine) Technical Manual

SET-2000 Oil/Sludge 12 VDC

Inductive slot sensor

4) Intrinsic Safety Certification

FP120-Z1 Power supply kit A (70 W) Technical Manual

FDCIO223 Input/output module (transponder)

FT2080 Fire terminal (Touch) Mounting Installation

Rosemount 3490 Series

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Synova TM product catalog.

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Manual Isolating Barrier D461R1 (Revision 01)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

SET Installation and Operating Instructions. Level switch for one sensor

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

DOW1171 / DCW1151 Radio fire detection system

OilSET-1000 (12 VDC)

Fire safety products and accessories siemens.com/cerberus

IECEx Certificate of Conformity

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

SET-2000 Hi Level/Oil

Operating Instructions Edition 02/2007

Transcription:

FDCL221-Ex Line adapter (Ex) Addressed (FDnet-Ex/C-NET-Ex) For operating FDnet-Ex/C-NET-Ex peripheral devices in potentially explosive areas Sinteso Cerberus PRO Electrical isolation of Ex and non-ex lines in FDnet/C-NET Operation on stub or loop Status indicator/operating indicator with two LEDs MC link connection Installation in fire control panels or in an installation housing FDCH222

Properties FDCL221-Ex line adapter (Ex) Eco-friendly Environmentally friendly processing Reusable materials Electronic parts and synthetic materials can be separated Features Protected electronics Integrated operating indicator Integrated LED for signaling the isolation of the Ex area Function The line adapter electrically isolates Ex and non-ex areas It is not necessary for the housing to be connected to local ground The line adapter limits current and voltage in the Ex area and can also separate the Ex stub The power required for the line adapter to supply itself is taken from the FDnet/C- NET It is not necessary to connect an external power supply Operation possible on an FDnet/C-NET line or a stub There is therefore no separator function available on the non-ex side The line adapter has two connections for the detector line (FDnet/C-NET) in the non- Ex area and a connection in the Ex area (FDnet-Ex/C-NET-Ex) Two LEDs for displaying the operating status and faults, and for localizing the device Use The line adapter must not be installed in the Ex area The line adapter is used where the operation of Ex peripheral devices is required and isolates the Ex and non-ex areas The line adapter only makes it possible to operate FDnet-Ex and C-NET-Ex devices. There are other safety barriers (SB2, SB3) available for collective systems. Changing from existing collective systems to addressable Sinteso and Cerberus PRO fire detection systems Observe national regulations Ex installations must be carried out by qualified technical personnel Observe acceptance and documentation specifications Application on FDnet Area not at risk Area at risk FDnet Ex stub line 1 (FDnet-Ex) Ex stub line 2 (FDnet-Ex) FDnet 2

Application on C-NET Area not at risk Area at risk C-NET Ex stub line 1 (C-NET-Ex) Ex stub line 2 (C-NET-Ex) C-NET Installation The line adapter can be accommodated in an intermediate distributor in the riser zone on different floors, or at the former location of the collective control panel. Ideally, it is installed as close to the Ex area as possible because the cable lengths permitted in the Ex area, which are calculated individually in each case, are limited. Installation materials, protective spacing, and necessary markings in potentially explosive areas must correspond to the national directives. Observe specifications for insulation between Ex and non-ex lines. Installation in fire control panels or in an installation housing The separator can be installed on U-rails TS35 in the fire control panels FC20xx or FC72x or in an installation housing FDCH222. W = 22.5 mm, H = 117.6 mm, D = 113.8 mm 3

Technical data Dimensions (W x H x D) 22,5 x 117,6 x 113,8 mm Operating temperature -25 +60 C Storage temperature -30 +75 C Air humidity 95 % rel. Communication protocol FDnet/C-NET//FDnet-Ex/C-NET-Ex Color Black/blue Protection category according to EN 60529 IP20 System compatibility FDnet C-NET FS20, AlgoRex, SIGMASYS FS720 Operating voltage Nominal voltage (U n) Maximum voltage (U m) DC 12 33 V AC 253 V Operating current (quiescent)/(max. load) 1.5 μa / 25 ma Characteristics Uo 28 V Io 92 ma Po 644 mw Lo < 2.9 mh Co < 82 nf Linear output characteristics Ex classification IECEx Directive 94/9/EC: (ATEX Directive) [Ex ia Da] IIC, Ta = -25 +60 C [Ex ia Ga] IIIC, Ta = -25 +60 C II (1) G [Ex ia Ga] IIC, Ta = -25...+60 C II (1) D [Ex ia Da] IIIC, Ta = -25...+60 C Standard for potentially explosive area EN 60079-0:2012; EN 60079-11:2012; EN 60079-26:2007; EN 54-18 Ex approvals EC-type examination certificate IECEx EN 54 approvals VdS BVS 12 ATEX E 094 BVS 12.0079 G213108 4

Details for ordering Type Art. no. Designation Weight FDCL221-Ex S54329-F4-A1 Line adapter (Ex) 0.240 kg FDCH222 S54329-F10-A1 Installation housing 0.500 kg BPZ:5644780001 U-rail TS35, 122 mm long 0.040 kg BPZ:5644230001 U-rail TS35, 288 mm long 0.090 kg You will find additional information in the following documents: Equipment overview, doc no. 008164 (Sinteso), A6V10225323 (Cerberus PRO) For system compatibility, see the lists of compatibility, doc no. 008331 (Sinteso) and A6V10229261 (Cerberus PRO) Line adapter FDCL221-Extechnical manual, doc no. A6V10333771 Planning, mounting/installation, commissioning, maintenance/servicing of fire detection installations FS20 and FS720 in potentially explosive areas, doc no. A6V10324618 5

Siemens Schweiz AG Infrastructure & Cities Sector Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 www.siemens.com/buildingtechnologies 2014 Copyright by Siemens Switzerland Ltd Technical specifications and availability subject to change without notice. Document no. A6V10349349_c_en_-- FD20/FD720 manual Edition 06.2014 Register 8/8