250mm dia straight pipe length SP4 SP3. Air volume

Similar documents
Installation Instructions

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

GUG-01SL-E GUG-02SL-E GUG-03SL-E

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

Air to Air Heat Exchanger

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

Residential-Use Lossnay

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Lossnay RVX Fresh Series Air Ventilation

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

Heat Recovery Ventilation

Whole Home Heat Recovery Ventilation

GUG-01SL-E GUG-02SL-E GUG-03SL-E

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

with a Breath of Fresh Air

GUF-RD3 GUF-RDH3. OA Processing unit CONTENTS. OA Processing unit R410A

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

OA Processing unit GUF-RD4, GUF-RDH4

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

Manual No.'13 SAF-T-182. updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6

INSTALLATION MANUAL AIR CONDITIONER

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

DESIGN & TECHNICAL MANUAL

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

Fresh Master. Installation Instructions (For use by dealer/contractor) GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3. Models:

DESIGN & TECHNICAL MANUAL

Advanced Ultraviolet Burner Controller

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Supply air hood JSI-UV Installation-, adjustment and user guide

Ventilation. Technical Data. Heat Reclaim Ventilation EEDEN HRV design guide

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

Digital Inverter 4 series 8 & 10HP

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL

PEFY-P20VMS-E, PEFY-P40VMS-E PEFY-P25VMS-E, PEFY-P50VMS-E PEFY-P32VMS-E, PEFY-P63VMS-E

Ventilation. Product Information

DESIGN & TECHNICAL MANUAL

TEVHR. Heat Recovery Ventilator

USER S MANUAL HSC-14/18/24/24A

LOW STATIC HYDRONIC DUCTED UNIT

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

Installation Instructions

Fresh Air Ventilation

Fresh Air Ventilation

ERP PRO VESTA HR. Cross Flow Heat Recovery Unit. User s Manual ÇAPRAZ AKIŞLI IGK

Installation Instructions for Heat Recovery Ventilators with 2 Speed RNC Electronics. RNC Series. Residential Heat Recovery Ventilators (HRV)

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Ducted inverter reverse cycle air conditioning

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Si Heat Reclaim Ventilation - with DX coil - [Applied Models] VKM 50GAV1 VKM 80GAV1 VKM 100GAV1 VKM 50GAMV1 VKM 80GAMV1 VKM 100GAMV1

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

Ventilation. Technical Data. HRV design guide EEDEN HRV design guide

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

SH, VH & SE Models. SH, VH & SE Series Heat & Energy Recovery Ventilators IMPORTANT - PLEASE READ THIS MANUAL BEFORE INSTALLING UNIT

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

HEAT RECOVERY AIR HANDLING UNIT

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

INSTALLATION MANUAL Duct Type Series MH FECA

PUHY-P-Y(S)JM-A PFAV-P-VM-E(-F)

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Model 8120 and 8126 Safety & Installation Instructions

PANEL_RS2. Run / Standby Panel. INSTALLATION MANUAL Version 1.02 MITSUBISHI ELECTRIC FOR INSTALLERS. Page 1 of 25

E Specifications. Ver.1.2. Page: EKMC Product Name. Model Number. 3.Dimensions. Approved by. Checked by.

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

DESIGN & TECHNICAL MANUAL

panasonic.net/id/pidsx/global Lights up when conditions are normal (and at incipient liquid leak detection) Use as a warning Sensor

SERVICE MANUAL CLASSIC 10 SERIAL NUMBER FROM FEBRUARY 2011 (0211) TO PRESENT. DocID: 00G00089E

Central Heating and Ventilation

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

WHHR Midi & Midi Lite

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

Installation/Instruction Manual

Total Heat Exchanger GAE-50D GAE-80D GAE-100D GAE-150D GAE-400D GAE-350D GAE-500D

Engineering Data Book

INSTALLATION AND USER MANUAL

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Modular Supply Make-Up Air Unit

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

INSTALLATION AND USER MANUAL

DESIGN & TECHNICAL MANUAL

SAFETY AND INSTALLATION MANUAL MODEL 8100

Domestic & Commercial Fans

Engineering Data Book

Transcription:

MODEL LGH-100RVX-E SIGN Heat exchange system Heat recovery ventilating system Heat exchanger material Special treated paper plate heat exchanger Cladding Galvanized steel sheet Heat insulation material Self-extinguishing urethane foam Motor DC motor Blower 245mm diameter centrifugal fan Filter Non-woven fabrics filter (Gravitational method 82% EU-G3) Surrounding air condition Shall be between -10 and 40, 80%RH or less Suction air condition Supply fan operation under low outdoor temperature Shall be lower than 40, 80%RH -10 to -15 : Intermittent operation 60 min ON, 10 min OFF. -15 or less : Intermittent operation 55 min OFF, 5 min ON. Function Heat recovery ventilation/ Bypass ventilation, Fan speed 1,2,3,4 Weight 54kg Electrical power supply 220-240V/50Hz, 220V/60Hz Ventilation mode Heat recovery mode Bypass mode Fan speed SP4 SP3 SP2 SP1 SP4 SP3 SP2 SP1 Running current [A] 2.50 1.20 0.50 0.17 2.50 1.20 0.51 0.19 Input power [W] 420 200 75 21 420 200 75 23 Air volume [m 3 /h] 1000 750 500 250 1000 750 500 250 [L/s] 278 208 139 69 278 208 139 69 External static pressure [Pa] 170 96 43 11 170 96 43 11 Exchange Temperature 80.0 83.0 86.5 89.5 - - - - efficiency Enthalpy Heating 72.5 74.0 78.0 87.0 - - - - [%] Cooling 71.0 73.0 77.0 85.5 - - - - Noise [db] 37.0 31.0 23.0 18.0 38.0 32.0 24.0 18.0 Insulation resistance 10MΩ or more Direct strength AC 1500V 1 minute Characteristic curve 350 250mm dia straight pipe length 90 300 100m 80 250 80m 70 Static pressure (Pa) 200 150 100 SP3 SP4 60m 40m 60 50 40 Exchange efficiency (%) SP2 50 SP1 30 0 Air volume 1. The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz. The noise is measured at 1.5m under the center of the unit in an anechoic chamber. 2. Temperature exchange efficiency (%) is based on winter condition. 3. Heat recovery ventilation mode starts automatically while detecting OA temperature lower than 8, even Bypass mode is selected. Remote controller continues to display "Bypass ventilation" in this case. 4. Mitsubishi Electric measures figures in the chart according to Japan Industrial Standard (JIS B 8628), therefore the characteristic curves are measured by chamber method. 5. The noise level at 1.5m away from outlets in the 45 direction is about 21dB greater than the indicated value at fanspeed4. 6. On-site measurements by pitot tube method could be as much 20% difference from JIS test room conditions. If the measuring point is close to sources of turbulence like bends, contractions and dampers etc., it is difficult to measure air volume correctly. A straight duct length more than 10D (D=duct diameter) from the source of turbulence is recommended for correct measurement. On-site measurement should therefore be measured in accordance with BSRIA guideline (Commissioning Air Systems. Application procedures for buildings AG3/89.3(2001)). 7. Use this unit between static pressure 60Pa and 240Pa at Fan speed4. Otherwise the motor protection may work and reduce its output or the noise level might be larger. SPECIFICATIONS 20 0 500 1000 1500 0 50 100 150 200 250 300 350 400 (m 3 /h) (L/s) 1/5

Outline drawings UNIT mm SCALE N.T.S 1. When using the product where it is exposed to high temperatures and humidity (40 or more, RH 80% or more), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit. The product should not be used under such conditions. 2. Outdoor air may enter the Lossnay owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install an electrically operated damper to block the outdoor air. 3. In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an electrically operated damper. 4. In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to check the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. 5. The outside ducts must be tilted at a gradient (1/30 or more) down toward the outdoor louvers from the Lossnay, and properly insulated. (The entry of rain water may cause power leakage, fire, or damage to household property.) 6. The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. If it is expected that the ambient temperature around the place where the Lossnay unit is installed will be high during the summer air conditioning season, it is recommended that the indoor ductwork should be covered with insulation material. 7. Inspection opening (450 450mm or more) must be installed on the filter and Lossnay core removal side. 8. Before starting installation, be sure to fix ceiling suspension fixture with the attached screws according to the installation manual. OUTLINE DRAWINGS 2/5

Wiring diagrams M 1 EXHAUST FAN MOTOR M 2 SUPPLY FAN MOTOR REACTOR CN9 CN10 CN119 TAB3,4 LED6 Lower Printed Circuit Board Bypass monitor or Preheater signal output (*1) Malfunction monitor output (*1) Exhaust or Supply fan monitor output (*1) PZ- 61DR-E 2nd remote controller (Max 2 controllers) 2nd Lossnay unit (Max 15 units) M-NET transmission cable Uncharged A-contact COM Shield Wire 12V or 24V DC Mr.Slim (non-polar) (*1) MAX 240VAC 1A MIN 220VAC 100mA 24VDC 1A 5VDC 100mA 7 8 9 10 1 2 A B S 1 2 3 TM3 TB5 TM2 SA1 SA2 CN26 CN32 X15 X14 X13 CN17 LED3 TM4 Upper Printed Circuit Board LED4 LED2 LED1 SW2 SW5 CN118 CN19 CN18 GM TAB5 TAB2 TAB1 CN7 CN5 CN22 TH1(OA) TH2(RA) ISOLATOR(Field supply) LINE FILTER L N PE TM1 L N POWER SUPPLY M1: Motor for exhaust fan M2: Motor for supply fan GM: Motor for By-pass damper TH1: Thermistor for outside air TH2: Thermistor for return air SW2,5: Switch (Function selection) TM1: Terminal block (Power supply) TM2: Terminal block (External control input) TM3: Terminal block (Monitor output) TM4: Terminal block (Transmission cable) TB5: Terminal block (M-NET Transmission cable) TAB1,TAB2:Connector (Power supply) TAB3,TAB4:Connector (Reactor) Definition of symbols X13: Relay contact X14: Relay contact X15: Relay contact CN5: Connector (Thermistor RA) CN7: Connector (Motor for By-pass damper) CN9: Connector (Fan motor) CN10: Connector (Fan motor) CN17: Connector (Fan speed 1/2/3/4) CN18: Connector CN118: Connector CN19: Connector CN119: Connector CN22: Connector (Thermistor OA) CN26: Connector (By-pass, 0-10VDC Fan speed control) CN32: Connector (Remote control selection) SA1: Address setting rotary switch (10 digit) SA2: Address setting rotary switch (1 digit) LED1 to LED5: Inspection indicator lamp LED6: Power supply indicator lamp SYMBOL : Terminal block : Connector on PCB 1. With this product, the wiring installation method will vary according to the design of the system. 2. Perform electrical installation to meet local electrical regulations. 3. Always use double insulated PVC cable for the transmission cables. 4. Wiring work must be performed by qualified professionals. 5. All supply circuits must be disconnected before obtaining access to the terminal devices. WIRING DIAGRAMS 3/5

Lossnay model selection advices 1. Operating environment Install this product in an environment where the temperature ranges from -10 to +40 and the relative humidity is less than 80%RH. If condensation is expected to form, the fresh outside air should be treated. 2. Do not use under high temperature and humidity condition Condensation will occur and water will gather inside the Lossnay cores under high temperature and humidity condition, such as warm swimming pool, bathroom, greenhouse or foggy places. 3. Condition of outdoor, indoor and return air Avoid using Lossnay under air condition with acid, alkalis, organic solvent, oil mist, paint, or harmful gas as pesticide, corrosive gas, etc. 4. Insulation failure caused by salt or sulphur air and hot spring steam, rust, fire or malfunction may occur. Installing high quality filters inside outdoor air duct if the Lossnay operates in salt or sulphur air conditions. 5. Intake of mist or outdoor air during off-mode operation Outdoor air or mist may flow through the duct into your room when Lossnay is in off-mode in windy and foggy areas. To prevent intake of outdoor air or fog, a damper is advised to be installed. 6. Entry of insects When using the product in an environment where there is a window, or opening near the outdoor hood, so that insects are likely to gather around the interior or exterior light, take note that small insects may intrude into the Lossnay filters. 7. By-pass ventilation In the case of By-pass ventilation, the supply air temperature slightly rises more than the outside air temperature because of the effect around the ducts or the unit motors. 8. Usage of M-NET. When solely using Lossnay units, power supply unit is required to connect to centralised controller. Number of power supply units or the transmission boosters should correspond with the connected Lossnay units. Caution for installation 1. Do not modify the unit as it may cause malfunction. 2. Do not install Lossnay unit vertically or on an incline. It may cause malfunction or decrease performance. 3. Leave sufficient space for maintenance purposes. 4. The location of the air inlet Take care in locating air inlet to prevent intake of dirty air or disgusting smell from exhaust gas of factory, air from rubbish disposal, etc. 5. Take precautions when using the product in a quiet location. 6. Heat insulation foam for duct Take care as below to prevent duct condensation. 1 The two outdoor ducts (OA and EA) must be covered with heat-insulating material in order to prevent condensation. 2 If it is expected that the ambient temperature around the place where the Lossnay unit is installed will be high during the summer air conditioning season, it is recommended that the indoor ductwork should be covered with insulation material. 3 Outdoor air may come into the unit when not in operation the pressure difference between indoor and outdoor or the outdoor wind. In this case you should install a damper. 4 It is possible for condensation and freezing to occur in the cold regions inside the unit because of the outdoor air condition or humidity condition above ceiling. Make sure to install supplemental insulation foam. 5 In the case that air condition around Lossnay unit is high temperature in summer, it is recommended that there are heat insulation foam on indoor side duct to prevent heat recovery decreasing by warming indoor duct. In winter, it is possible to cool indoor side duct without heat insulation foam on indoor side duct. 7. Prevent entry of rainwater into Lossnay unit Install weather louver or "Weather cover" for OA inlet & EA outlet. This is to prevent rainwater entering the Lossnay unit. Ducts to outdoor (OA and EA) should decline by 1/30 or more. 8. Install the anchor bolts to ensure the product s weight or earthquake load. Correctly rated wire/chain may also be used. 9. Do not install this product in a place where it is exposed to ultraviolet light. UV may damage covering insulation. 10. Electrical Work A single pole isolator must be installed at the origins of mains power supply. Use single flush box, to support remote controller. Must connect ground wiring. When connecting external devices (electrically operated damper, lamp, monitoring unit, etc.) using output signals of the Lossnay unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment) SAFTY NOTES 4/5

11. Duct heater In the case of installing a duct heater interlocked with Lossnay, be sure to observe the following: 1 Select a duct heater in compliance with local and national laws, ordinances, and standards. Select a duct heater that has obtained the CE mark. 2 Always select a heater that is equipped with a non-self-resetting safety device. Do not directly supply power from the Lossnay unit to the duct heater. Doing so could cause fire. 3 Install a circuit breaker for the duct heater in compliance with all applicable laws, ordinances, and standards. 4 Install the duct heater separated from the product by a distance of 2 m or more. Failure to do so may result in equipment damage due to the transmission of residual heat from the heater. 5 When using a heater without a temperature control function, select a heater with a capacity that is matched to the air volume. 6 Do not use the heater outside the set air volume. If the heater s capacity is too larger, this may result in the heater frequently turning ON/OFF. If the heater s capacity is too small, this may result an inability to heat. 7 Ensure that the duct heater and Lossnay are wired and that the Lossnay function settings have been configured, and then always check operation by trial operation. Maintenance and lifetime Remove all dust and dirt on air filters and Lossnay cores at regular intervals to prevent a deterioration in the Lossnay function. Refer to each model's operation instructions for the suggested maintenance period and methods. General indication of lifetime of the main parts is as below. Time below is unrelated to guaranteed period for service. And parts exchange period varies with usage condition. Lossnay cores Air Filters High efficiency filters Motor : Around 10 years with maintenance at stated periods. : Around 5 years with maintenance at stated periods : 3000 hours : 30000 hours SAFTY NOTES 5/5