Installation Instructions

Similar documents
250mm dia straight pipe length SP4 SP3. Air volume

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

GUG-01SL-E GUG-02SL-E GUG-03SL-E

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

INSTALLATION MANUAL AIR CONDITIONER

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

Installation/Instruction Manual

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

INSTALLATION MANUAL RHF025EE Series RHF035EE Series RHF050EE Series RHF080EE Series RHF100EE Series

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Safety. Connect the product properly to the ground. (Malfunctioning or power leaks can cause electrical shock.)

General safety precautions English

General safety precautions English

CONTENTS INSTALLATION MANUAL HFC FOR INSTALLER R410A. utilized 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY... 2

General safety precautions English

Kyung Dong Oil Boiler. Contents. 1. General Warnings Safety Warnings

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Split-type Air-Conditioner

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

1. BEFORE INSTALLATION

Split-type Air-Conditioner

Manual No.'13 SAF-T-182. updated December 02,2013 TECHNICAL MANUAL AIR TO AIR HEAT EXCHANGE UNIT SAF150E6 250E6 350E6 500E6 650E6 800E6 1000E6

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

HFC 1. THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY 2. SELECTING THE INSTALLATION LOCATION

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Split-type Air-Conditioner

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

Residential-Use Lossnay

General safety precautions English

General safety precautions English

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Fresh Master. Installation Instructions (For use by dealer/contractor) GUF-50RDH3 GUF-50RD3 GUF-100RDH3 GUF-100RD3. Models:

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

General safety precautions English

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

PARTS & ACCESSORIES INSTALLATION AND SAFETY INSTRCUTIONS ITEM NO.:60010BZGTGLD SAFETY PRECAUTION. Canopy. Downrod. Housing. Transmitter CR2032/3V

INSTALLATION MANUAL Duct Type Series MH FECA

FLOOR TYPE AIR CONDITIONERS

ERP PRO VESTA HR. Cross Flow Heat Recovery Unit. User s Manual ÇAPRAZ AKIŞLI IGK

GDDEM10 DEHUMIDIFIER

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

FULL AUTOMATIC EXTINGUISHING SYSTEM FOR INDUSTRIAL MACHINERY YAC-3A. Table of Contents

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

INSTALLATION INSTRUCTION for ceiling fan

INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

INSTALLATION INSTRUCTIONS

SAFETY AND INSTALLATION MANUAL MODEL 8100

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

Purge Ventilation Unit. Product Manual. ventilation systems TP625

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Residential Gas Hybrid Water Heater

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan

LG Ventilation Kit INSTALLATION MANUAL. Model: PTVK410 / PTVK420. website

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

Installation Instructions

Air to Air Heat Exchanger Installation Manual. Concealed microcomputer control type. Installation Manual 1 English. Installation Manual xx Xxxxx

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

BS-1015BSW. WARNING Indicates a potentially hazardous situation which, if mishandled, could result in death or serious personal injury.

COBRA -H EXTRACTOR 120V

[FLARE CONNECTION TYPE] ATTENTION

MANUAL. OEM (Unit) OZONE GENERATOR (100VA, 200VA and 300VA) INDEX

1. BEFORE INSTALLATION

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

ULTRA LOW TEMPERATURE FREEZER. User Manual

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

1. BEFORE INSTALLATION

Installation Guide. For Models: E-DCF52BNK5C3 E-DCF52FBZ5C3 E-DCF52MWW5C3 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Installer manual AG-WL10

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

Installation Guide. For Models: E-PD52ABZ5C4 E-PD52BP5C4 E-PD52WW5C4 READ THESE INSTRUCTIONS AND SAVE THEM FOR FUTURE USE

1. Included Accessories. Installation Manual. System Controller SC-201-6M-EXT(-OD, -DVC) Requests to Installers

INSTRUCTION MANUAL TABLE OF CONTENTS

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

1. BEFORE INSTALLATION

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Transcription:

0908HN50 Lossnay Energy Recovery Ventilator Model: LGH-50RSDC-E (0-0V 50Hz) Installation Instructions (For use by dealer/contractor) Contents Safety precautions... Outline drawings... Standard installation examples... Installation method... Function settings... Trial operation...8 This product needs to be installed properly in order to ensure maximum functionality as well as safety. Please make sure to read this installation manual before starting the installation. Installation must be performed by a dealer or installation contractor. Please note that improper installation may cause malfunction or accident. Separate booklet Operating Instructions is provided for the customer. The booklet and this manual must be handed over to the customer after completing the installation. Safety precautions The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below. Do not disassemble Prohibition of use in bath or shower room Connect the grounding wire. The instructions given must be followed. Do not modify or disassemble. (It could cause fire, electric shock or injury.) The Lossnay unit should not be installed where it is highly humid, like a bathroom, or other wet place. (It could cause electric shock or power leakage.) Connect the product properly to ground. (Malfunctioning or power leaks can cause electrical shock.) Use the specified power supply and voltage. (Use of incorrect power supply or voltage could cause fire or electric shock.) Select a place with sufficient strength and install the main unit securely. (It could cause injury if it falls.) WARNING The instructions given must be followed. Wiring work must be performed by qualified professionals, and be implemented safely and securely in accordance with the engineering standards and the extension wiring rules for electrical equipment. (Poor connection or improper wiring work could cause electric shock or fire.) Install a power supply isolator at the power supply side as per local electrical regulations. (It could cause fire if power leakage occurs.) All supply circuits must be disconnected before obtaining access to the terminal devices. Use the specified cable size and connect the cables securely to prevent disconnection when they are pulled. (If there is a defect in the connection, there is a possibility of fire.) Select an adequate place for the opening to introduce outdoor air, where it will not inhale the exhaust fumes like combustion gas, or others, and there is no risk of blockage by snowfall or others. (Shortage of fresh air could put the room in a state of oxygen deficiency.) A duct made of steel must be installed with care not to be connected electrically with metals such as metal, wire, stainless steel plate, or others. (It could cause fire when power leakage occurs.) Prohibited Do not place a burning appliance in a place where it is exposed directly to the air from the Lossnay unit. (It could cause an accident as a result of incomplete combustion.) Do not place an object on or sit on the Lossnay unit. (It could cause electric shock, fire, or other damage.) Do not use at a place where exposed to high temperatures (0 C or higher), naked flames, or in environment with combustible fumes. (It could cause fire.) Do not use in an environment such as a chemical factory, where hazardous gases such as acidic gases, alkaline gases, organic solvent fumes, paint fumes, or gases containing corrosive components are generated. (It could malfunction.) Insulation failure caused by salt or sulphur air and hot spring steam, Rust, fire or malfunction may occur. Installing high quality filters inside outdoor air duct if the Lossnay operates in salt or sulphur air conditions. Do not install this product in a place where it is exposed to ultraviolet light. (UV may damage covering insulation.) The instructions given must be followed. Put on gloves during maintenance. (It could cause injury.) Make sure the power supply isolator is turned off on the power distribution panel when Lossnay is not used for a long period of time after the installation. (It could cause electric shock, power leakage, or fire as a result of deteriorated insulation.) Always use the specified suspension bolts, nuts and washers. (Use of hardware with insufficient strength could result in the product dropping.) The outside ducts must be tilted at a gradient (/0 or more) down toward the outdoor louvres from Lossnay, and properly insulated. (The entry of rain water may cause power leakage, fire, or damage to household property.) The control box cover must be closed after the installation. (Dust or humidity may cause power leakage or fire.) When connecting external devices (electrically operated damper, lamp, monitoring unit, etc.) using output signals of the Lossnay unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment.)

Safety precautions (continued) When using the product where it is exposed to high temperatures and humidity (0 C or higher, RH 80% or higher), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit. The product should not be used under such conditions. Outdoor air may enter the Lossnay owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install also an Electrically operated damper to block the outdoor air. In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an Electrically operated damper to shut them out. When using the product in an environment where there is a window, or opening near the outdoor louvre, where insects are likely to gather around the interior or exterior light, take note that small insects may intrude into the product. In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to confirm the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. *Example of dewing condition Outdoor air: -5 C or lower, dew-point temperature at installation place: 0 C or higher (When the indoor temperature is C or higher with the relative humidity higher than 50%, or other) Outline darawings 9 898 9 9 08 Accessory parts Mounting screws...x Duct connecting flanges...x (double flanges at SA and sides) Power cord opening Wall anchor point (-x0 oval) Control box 80 Maintenance cover Air exhaust fan 0 Bypass damper plate 9 680 05 099 RA (return air) SA (supply air) 6 0 99 0 Ceiling suspension fixture (-x0 oval) Lossnay cores Air supply fan (Air filters) Foot plate 8.5 0 0 Weight : 6 kg (mm)

Standard installation examples Electrically operated damper (Protection against the intrusion of cold air while Lossnay is stopped in winter) (To be provided by the customer) Lossnay unit In a region where there is risk of freezing in winter, it is recommended to install an Electrically operated damper, or the like, in order to prevent the intrusion of (cold) outdoor air while Lossnay is stopped. This product is designed to use horizontally as the figure or upside down. Do not install vertically with the product suspension fixture. The outside sir intake must be located where no rainwater or fog comes in to prevent the intake of water. Example <Installation vertically> <Installation horizontally> Wall Anchor bolt (to be provided by user) More than 5 00 Supply air grille Maintenance space 00 Maintenance space 00 Return air grille Supply air grille Return air grille Keep the unit more than 5mm away from the wall. Top/bottom reverse installation is not available for this unit Return air grille Downward gradient of duct: /0 or more (toward wall side, provide m or more) (to prevent rain water from seeping in) Downward gradient of duct: /0 or more (toward wall side, provide m or more) (to prevent rain water from seeping in) Anchor bolt (to be provided by user) SA (supply air) Supply air grille RA (return air) Maintenance space 00 Maintenance space 000 Duct Floor should be on the floor by foot plate. Duct Return air grille RA SA (return air) (supply air) Supply air grille Do not install the unit on the ceiling plate directly to prevent the unit from falling, and making vibration and noise. (mm)

Installation method Installing the Lossnay unit ) Preparing the anchor bolts Mount the washers (outer diameter of > mm for M0) and nuts onto the pre-recessed anchor bolts (M0), as shown in the figure below. Duct connecting flange (Accessory parts) Anchor bolt (M0) ) Attaching the duct connecting flanges Use the supplied screws to secure the duct connecting flanges to the Lossnay unit. All mounting screws for the ceiling suspension fixture should be tighten even if the unit is installed vertically. If wall material is wood, tighten up by wood screws. Confirm whether strength of wall is enough. When suspending Lossnay unit from the ceiling, do not handle it in such a way that force will be applied to the control box. Install the anchor bolts to ensure the product's weight or earthquake load. (Correctly rated wire / chain may also be used) ) Connecting the ducts () Fasten the duct securely to the duct connecting flange, and wrap aluminum tape (not included) around the joints so that there is no air leakage. () Suspend the ducts from the ceiling so that their weight will not be applied to the Lossnay unit. () All ducts must be covered with heat-insulating material in order to prevent condensation from forming. Heat-insulating material Aluminum tape Mounting screw Outdoor duct Lossnay unit Before attaching the duct connecting flanges, check that no foreign matter (scraps of paper, vinyl, etc.) has found its way inside to Lossnay unit. Attach the duct connecting flanges with the packing at the SA and RA sides. ) Mounting Lossnay unit <Installation horizontally> () Loose the screw on the ceiling suspension fixture. () Turn the fixture around the loosened screw by 90 degrees to set it at level. () Fix the fixtures securely on the fan body by tightening the loosened screw and accessory mounting screws. () Hang the ceiling suspension fixtures on the anchor bolts and adjust in such a way that Lossnay unit is level. (5) Tighten up securely using double nuts. <Installation vertically> () Wall anchor point should be hang by M0 anchor bolt. () Tighten up securely using washar (more than p6mm) and M0 nut. Ceiling suspension fixture Mounting screw <Installation horizontally> Anchor bolt Duct connecting flange Before attaching the ducts, check that no (debris or any other) foreign matter (scraps of paper, vinyl, etc.) has found its way inside the ducts. Do not touch the damper plate inside Lossnay unit when connecting the ducts. If it is expected that the ambient temperature around the place where the Lossnay unit is installed will be high during the summer air conditioning season, it is recommended that the indoor duct work be covered with insulation material. Do not carry out the following types of duct construction. (Doing so could cause a drop in the air volume and generate abnormal noises.) Extremely sharp bends Multiple bends Bends right next to the outlet Extreme reduction in the diameter of the connected ducts Loosen <Installation vertically> Anchor bolt Wall anchor point Ceiling suspension fixture (Not, in use)

Installation method (continued) Electrical installation With this product, the wiring installation method will vary according to the design of the system. Perform electrical installation to meet local electrical regulations. * Always use double insulated PVC cable for the transmission cables. * Wiring work must be performed by qualified professionals. * All supply circuits must be disconnected before obtaining access to the terminal devices. Names of components in control box LED CN9 CN8 LED Line filter CN Transformer CN0 AC Reactor TM LED CN TM CN TM CN TM CN6 Fuse CN CN5 LED SW SW CN CN6 Wire connection diagram Connect the wires shown as dotted lines. Be sure to connect the ground wire. A power supply isolator must be installed when wiring power supply to unit. Always use a single pole isolator for the main switch power connection. All supply circuits must be disconnected, and do not touch the components for more than 5 minutes, before obtaining access to the terminal devices. If using earth leakage breaker for isolator, rating of sensed current should be more than 0mA. (SA) M () M WHITE(W) 5 (V) BLACK(U) WHITE(W) 5 (V) BLACK(U) CN9 6 5 BLACK BLUE GREEN BROWN BLACK BLUE GREEN BROWN LED CN GREEN LED LG-08DC -E-M High voltage (LEFT) CN6(red) CN5 CN GREEN / YELLOW CN8(red) CN0 CN CN FUSE 6.A/50V YELLOW BROWN Control Box CN(red) BLUE Reactor LINE FILTER Transformer POWER SUPPLY 0-0V 50Hz Isolator LED LED GREEN V TM PB SW 5 LG-08DC -E-C CN5 (RIGHT) () BLUE(-) COM TM CN6 CN TH(RA) TH() BROWN BLUE GREEN / YELLOW CN TM L N PE L N TM 0 9 8 GREEN / YELLOW YELLOW LS Malfunction monitor output MAX MIN AC0V A AC0V 00mA DC V A DC 5V 00mA GM monitor output MAX MIN AC0V A AC0V 00mA DC V A DC 5V 00mA Power By-pass condition select Fan speed 5 Fan speed Fan speed Fan speed Fan speed Fan speed select MARK :Terminal block :Connector :Connector on PCB Symbol explanation M: Motor for exhaust fan M: Motor for supply fan GM: Motor for Bypass damper LS: Micro switch TH: Thermistor for outside air TH: Thermistor for return air TM: Terminal block (Power supply) TM: Terminal block (Fan speed selection) TM: Terminal block (By-pass mode selection) TM: Terminal block (Monitor output) LED(red): Power supply indicator lamp LED(red): Inspection indicator lamp LED(green): Inspection indicator lamp LED(green): Inspection indicator and trial operation lamp CN: Connector (Power supply) CN: Connector (Transformer primary) CN: Connector (Motor for By-pass damper) CN: Connector (Reactor) CN5: Connector (Reactor) CN6: Connector (Supply fan motor) CN: Connector (Exhaust fan motor) CN8: Connector (Signal for supply fan motor) CN9: Connector (Signal for exhaust fan motor) CN0: Connector (Signal line) CN: Connector (Transformer secondary) CN5: Connector (Signal line) CN6: Connector (Thermistor) CN: Connector (Micro switch) 5

Installation method (continued) Connecting the power supply cable ) Remove the screws and the control box cover ) Connecting the power supply cable Pass the power cable through the bush* and connect to the TM terminal block using the round terminals. Connect the ground wire to the ground terminal and secure tightening the bush. (*: for PG connector or the like) Ground wire TM Screw Control box cover PG connector (customer preparation) Power supply cable operating method Fan speed select Operated fan speed is followed as below table by the fan speed select contacts. Fan speed select contact Fan speed All contacts : OFF OFF : ON Fan speed : ON Fan speed : ON Fan speed : ON Fan speed 5 : ON Fan speed 5 Multi contacts : ON Higher fan speed operate Fan operating may be delayed from the time of contact ON depending on the select timing. By-pass condition select By-pass damper is automatically operated based on the and RA temperature. Power By-pass condition select ( * ) When turning on Power By-pass contact with any fan speed contacts on, unit operation becomes power By-pass mode. Always separate the power supply cable and the cable to the control unit by 0 cm or more to prevent malfunctioning of the unit. If the length of the stripped power cables wires is too long, the conductors may touch and short out. Power supply cable size :.5 mm or more. () Refer to the wiring diagram and screw down the ground wire and the cables to the terminal block. () Secure the power supply cable with the PG connector and the Transmission cables with the cord clip. Upon completion of the wiring connections, replace the control box cover. ) Connecting the cables for fan speed select and Bypass condition select Connect the cables and the contacts as below. Put the wires deeply to the holes of contact with pushing the button. Confirm no unconnected wire. TM Button TM TM Transmission Cable Bush Cord clip com 5 PB V TM V PB Insert the cutting Bush Ventilation priority mode Power By-pass condition select ) The following system configuration can be created. Connect the necessary parts. () If you would like to connect to a Electrically operated damper, etc., or would like to fetch operation monitor output. () If you would like to fetch Malfunction monitor output. () When connect to an Electrically operated damper, etc., or take operation monitor output: Connect the power supply from the Electrically operated damper to 8 and 9 of the monitor output terminal block (TM) with reference to the wire connection diagram. TM Power supply x Electrically operated damper Lamp or monitoring unit () When take Malfunction monitor output: Connect to 0 and a of the monitor output terminal block (TM) with reference to the wire connection diagram. TM Power supply x Lamp or monitoring unit Fan speed select It is recommended to connect Malfunction monitor output to check the malfunction externally. contact: VDC 0 ma cable for operation: 0.5mm to.0mm maximum length: 0m from terminal block peeling wire length: 9~0mm Power By-pass mode is not available even if only PB contact is on. ( * ) Be sure to connect Fan speed 5 wiring. 6

Function settings Trial operation SW SW Trial operation monitor out put with delay function Setting for exhaust fan in cold region operation mode Ventilation priority mode during ventilation setting input on Operating monitor output By-pass auto ventilation priority setting Auto air volume increasing during bypass setting Not to used Decreasing exhaust fan power Increasing exhaust fan power Decreasing supply fan power Increasing supply fan power Normal operation Trial operation monitor out put with delay function * (TM 89) SW Not available Available Exhaust fan speed setting in cold region operation mode * SW Not fixed Exhaust fan : speed 5 fixed Ventilation priority mode during ventilation setting input on SW Bypass ventilation mode fixed Lossnay ventilation mode fixed * Below 8 C, even SW- is fixed any setting, ventilation mode should be Lossnay ventilation. 5 Operating monitor output (TM 89) SW 5 Not available 5 Available * During SW- on, operating monitor out is prior to operation motor out put with delay function. 6 By-pass auto ventilation priority setting SW SW All switches are OFF at factory setting. 6 When outdoor temperature is C or higher within hours, then bypass ventilation starts by comparison and RA. Auto air volume increasing during bypass setting SW *Cold region operation mode The unit operation is based on the measured temperature as below. mode temperature SA fan fan Normal -0 C< Continuous running Continuous running SA intermittent -5 C<<-0 C SA stopped Not increasing. 8 Fan speed fine-tuning SW ON OFF or or <-5 C When unit is in by-pass operation except power by-pass mode, the unit fan speed is automatically increased step. All supply air fan speeds are default settings. Each supply air fan speed settings except power bypass mode are increased. Each supply air fan speed settings are decreased. All exhaust fan speeds are default settings. Each exhaust fan speed settings except power bypass mode are increased. Each exhaust fan speed settings are decreased. * monitor out put with delay function Corresponds to operation mode output (TM 89) Supply fan with following function - Start the output (TM 89) 0 seconds after supply fan operates but also when the thermistor for outside air (TH) detect -5 C or lower. - Stop the output (TM 89) when thermistor for outside air (TH) detects a temperature higher than -5 C or stop the supply fan or malfunction of TH. - Lossnay continues to operate for minutes, after stopping the output (TM 89) - Error code is shown on the remote controller and stop the output in case of followings. ) TH detects higher than 5 C within 5 minutes after the output starts. ) TH detects -0 C or lower, 60 minutes after the output starts. ) TH detects continuously 0 C or higher for more than minute. Repeat 0min. Stop / 60min. running Repeat 55min. Stop / 5min. running Continuous running Continuous running Fan speed 5 is fixed in SA fan stopped operation in the case of SW-. SA : supply air : exhaust air : outside air 6 When outdoor temperature is 8 C or higher within hours, then bypass ventilation starts by comparison and RA.

Trial operation After the system has been installed and before the ceiling panel is installed, make sure that wires are properly connected, then test the system s operation. () Remove the control box cover. () Turn the trial operation switch (SW-) On. LED will be on with the Fan speed setting and with By-pass ventilation operating for min. Then, it will change to energy recovery ventilation mode. () Turn the trial operation switch (SW-) Off. () Install the cover in its original position on the control box. Trouble shooting Cause of failure LED (red) Small PCB (right) LED indication (Blinking) LED (green) LED (red) Large PCB (left) Supply fan over current failure Twice - Once - LED (green) Exhaust fan over current failure - Twice - Once Shortage of power supply voltage Twice - times - Over voltage of power supply Twice - times - Supply fan motor operating failure Twice - 5times - Exhaust fan motor operating failure - Twice - 5times Supply fan motor sensor failure Twice - 6 or times - Exhaust fan motor sensor failure - Twice - 6 or times Communication failure between upper and lower PCB 9times 9times 9times 9times Damper failure times - - - Outside air sensor failure times - - - Room air sensor failure 5times - - - External interlocked unit failure 8times - - - If troubles occur as above, turn off all fan speed contacts immediately and contact to your dealer. The unit may not operate properly if the power supply voltage is lower than the rating voltage. (0-0V) Motor operation stop running HD OFFICE: TOKYO BLDG., --, MARUNOUCHI, CHIYODA-KU, TOKYO 00-80, JAPAN AUTHORIZED REPRESENTATIVE IN EU: MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 QQ, U.K.