RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

Similar documents
with a Breath of Fresh Air

Lossnay. Total Heat Exchangers

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

Lossnay. Total Heat Exchangers

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

Lossnay. Total Heat Exchangers (RX4)

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Residential-Use Lossnay

250mm dia straight pipe length SP4 SP3. Air volume

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

Lossnay RVX Fresh Series Air Ventilation

Installation Instructions

INDOOR UNIT PLFY-VAM / VCM PCFY-VGM PKFY-VAM / VGM / VFM PMFY-VBM

Whole Home Heat Recovery Ventilation

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Ventilation. Product Information

Central Heating and Ventilation

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Fresh Air Ventilation

Fresh Air Ventilation

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

CONTENTS. Lossnay Unit

Synergy 405PLUS User Guide Manual

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

The importance of control

DESIGN & TECHNICAL MANUAL

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

Central Heating and Ventilation

Ducted inverter reverse cycle air conditioning

A ducted recovery (ventilation) system Lossnay LGH-RVX

Ducted Air Conditioning

MA Remote Controller PAR-31MAA

GUG-01SL-E GUG-02SL-E GUG-03SL-E

VERSO-P, VERSO-R Series Air Handling Units with C3 Control System Electrical Installation and Operation Manual

WALL MOUNTED AIR CONDITIONER RANGE THE PERFECT CLIMATE.

DESIGN & TECHNICAL MANUAL

MSZ-L SERIESES. Luminous and Luxurious Design

Ducted Air Conditioning

Air Conditioner CONTENTS

DESIGN & TECHNICAL MANUAL

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Lo-Carbon Sentinel Kinetic Horizontal

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Series PEAD SERVICE MANUAL SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS R32/R410A PEAD-SM100JA(L) PEAD-SM125JA(L) PEAD-SM140JA(L) Models PEAD-SM71JA(L)

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

Energy-saving operation

Why do we need fresh air ventilation?

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

WHHR Midi & Midi Lite

DUCTED REVERSE CYCLE AIR CONDITIONING. The Ultimate Comfort Experience... All Year Round.

OA Processing unit GUF-RD4, GUF-RDH4

Home & Office Electronics

Technology that works fast. Inverter Ducted Systems

Heat Recovery Ventilation

GUF-RD3 GUF-RDH3. OA Processing unit CONTENTS. OA Processing unit R410A

DESIGN & TECHNICAL MANUAL

Inverter console UFV system. Compact design and personalised air flow selection

VEX100 series Air handling units with cross-flow heat exchanger

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

GUG-01SL-E GUG-02SL-E GUG-03SL-E

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

Heat Pump Air Conditioning Systems

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

Dee Fly Cube 300 and 370. Heat Recovery ventilation

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

AIR CONDITIONER MALAYSIA S FIRST REVERSE CYCLE SOLAR PV-INVERTER

Come home to a warm welcome

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

GUG-01SL-E GUG-02SL-E GUG-03SL-E

Hi - Wall Split Systems 12K - 18K - 24K

AIR HANDLING UNITS ver B

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

Healthy, comfortable and energy-efficient ventilation

ENG. IDEO 325 Ecowatt. Installation Manual

Air Conditioner. User manual. Wired remote controller MWR-WE11N

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

VENTILATION. Effective heat exchange and fresh air ventilation

DESIGN & TECHNICAL MANUAL

Air to Air Heat Exchanger

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

NOTE: All the illustrations in this manual are for explanation purposes only. Your air conditioner may be slightly different.

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Operating Instructions High-spec Wired Remote Controller

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

Indoor Air Quality Product Brochure.

Transcription:

28.LOSSNAY**2.qxd 11/14/8 4:55 PM Page 3 ENERGY RECOVERY VENTILATORS MODEL RX5 SERIES C o n c e n t r a t i n g w h a t w e c a n d o. m o r e, e v e r a n d d e f i n i t e l y...

28.LOSSNAY**2.qxd 11/14/8 4:55 PM Page 4 Simple and Effective Excellent air quality and unbeatable Heat Efficiency Try blowing into a rolled up piece of paper. The warmth of your breath travels through the paper to your hands. Some 38 years ago, that simple principle led to the development of our most advanced air-conditioning technology. Poor air quality can be attributed to many problems arising in the workplace or in the home. It is believed to contribute to a Fresh air from outside Stale exhaust air Heat exchange unit (LOSSNAY core) significant loss in productivity, low morale and higher rates of sickness among many employees. The object of providing good ventilation alongside air condition in residential and commercial buildings is to provide conditions under which people can live and work comfort and safety. Fresh air supply to the room Stale room air extracted Developed and refined over the past 3 years, the LOSSNAY system has perfected the recovery of waste energy. The units reduce overall energy costs by extracting stale air and then recovering the heating or cooling energy to either warm and cool incoming fresh air. By utilising this energy, the LOSSNAY system can save up to 3% on initial capital costs of heating and cooling plant. 1

28.LOSSNAY**2.qxd 11/14/8 4:57 PM Page 5 LOSSNAY s Energy Recovery Technology and Simultaneous Ventilations (Supply and Exhaust) Contribute to Excellent Indoor air Quality and Significantly Reduce the Outdoor air load. Energy-Recovery Concept by Hyper Eco LOSSNAY Core In summer Temperature difference between air supply and room: 1.7 ºC In winter About 4kg/h of water vapor is recovered. Supply air Dry bulb temperature (ºC) LOSSNAY 27.7 Conventional ventilator 33 Supply air Dry bulb temperature (ºC) LOSSNAY 16 Conventional ventilator Absolute humidity (g/kg'(da)) Relative humidity 13.4 58 2.1 63 Exhaust air Absolute humidity (g/kg'(da)) Relative humidity 5.2 46 1.9 Exhaust air Enthalpy (kj/kg(da)) 62.1 84.6 Enthalpy (kj/kg(da)) 29.2 4.7 Total heat recovered (kw) 7.5 Total heat recovered (kw) 8.2 Outdoor air load (kw) 3.1 1.6 Outdoor air load (kw) 3.1 11.3 Outdoor air load ratio 71 1 Outdoor air load ratio 72.5 1 Room air Outdoor air Room air Outdoor air Dry bulb temperature 26ºC Dry bulb temperature 33ºC Dry bulb temperature 2ºC Dry bulb temperature ºC Air conditioner Absolute humidity Relative humidity 1.5g/kg'(DA) % Absolute humidity Relative humidity 2.1g/kg'(DA) 63% Air conditioner Absolute humidity Relative humidity 7.3g/kg'(DA) % Absolute humidity Relative humidity 1.9g/kg'(DA) % Enthalpy 52.9kJ/kg(DA) Enthalpy 84.6kJ/kg(DA) Enthalpy 38.5kJ/kg(DA) Enthalpy 4.7kJ/kg(DA) Energy-recovery calculating equation Indoor supply-air Outdoor Outdoor Indoor temperature (ºC) = recovery temperature (ºC) { temperature (ºC) temperature (ºC) } Temp Calculation example : 27.7ºC=33ºC _ (33ºC _ 26ºC) 76% * The above applies to the case of LGH-1RX5 ( notch). Energy-recovery calculating equation Indoor supply-air Indoor = _ Outdoor temperature (ºC) temperature (ºC) temperature (ºC) } Temp recovery Outdoor { + temperature (ºC) Calculation example : 16ºC=(2ºC _ ºC) 8%+ºC Every building needs a supply of fresh air to keep its inhabitants healthy and comfortable. Outdoor air though is rarely, if ever, the same temperature as that maintained by the building, s air conditioning system. In the summer, it is too hot. In the winter, it is too cold. This puts added stress on the air conditioner to compensate for the intake of the hot or cold air adding to the expense of operating the system. LOSSNAY all but eliminates this problem with original energy-recovery technology that uses the heat of the stale indoor air to be expelled in order to either heat or cool the incoming fresh air to a temperature much closer to the existing indoor air. This process reduces the load on the air conditioning system without cutting off the supply of vitally necessary fresh air. Stale air exhaust (dirty indoor-air) Outdoors Fresh air induction (fresh air) LOSSNAY Core Construction & Principle Fresh air exhaust (fresh heating/cooling air) SA Indoors RA Stale air induction (dirty heating/cooling air) The basic principle The remarkable technology that permits the intake of fresh air with minimal loss to indoor temperature is know as the LOSSNAY Core. The cross-flow, plate-fin structure of the energy-recovery unit along with a specially processed diaphragm keep supply and exhaust air separate, ensuring that only fresh air is introduced to the indoor environment while also allowing for the efficient transfer of heat. The improvements The microscopically small pores of the diaphragm have been made even smaller, decreasing the rate at which water soluble gases such as ammonia and hydrogen pass through. Further, a new specially processed paper used to make the diaphragm has been developed with high moisture permeability characteristics that aid in the transference of moisture for improved energy exchange. These developments further improve moisture permeability and effectiveness in shielding unwanted gases, resulting in a lower rate of gas transference and more highly efficient energy transfer. 2

28.LOSSNAY**2.qxd 11/14/8 4:59 PM Page 6 Hyper Eco Core Better energy conservation by improved total heat exchange. Introducing the new Hyper Eco Element Mitsubishi's newly developed Hyper Eco Element is on board, offering the industry's best total heat exchange. Energy conservation performance has been improved not only by reducing the air conditioning load associated with ventilation, but also by facilitating humidity penetration. Outdoors (exhaust air) Indoors SA (supply air) Element Structure improve *Cooling, Fan speed, Hz 74% RX4 RX5 (outside air) RA (return air) 73% 72% Hyper Element Humidity does not penetrate easily. Spacerplates Hyper Eco Element Humidity penetration is facilitated. 71% 7% 69% 68% Improved adhesive agent material 67% Adhesive agent with low humidity penetration rate Dividerplates Humidity New adhesive agent with high humidity penetration rate 66% 65% 64% RX Type 25RX Type 35RX Type RX Type 65RX Type 8RX Type 1RX Type 1RX Type 2RX Type Extra Mode Additional energy conservation by using a four-level air volume system that allows more precise control. In addition to the conventional Extra,, and modes, an Extra mode is added to provide a more dynamic range of air volume settings and versatility in a variety of installation environments, yielding much better energy conservation. Using a simplified timer function, it switches to Extra operation when the operation stop button is activated and it is accordingly possible to implement 24-hour energy conservation ventilation. A) Extra B) Extra Extra * The Extra and ventilation modes are selectable by the initial setting. * Extra- not equipped LGH-1RX5 and 2RX5. * The ventilation mode is actually selected in three levels, and the remote controller also displays these three levels. 3

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 7 New function: "By-pass" Ventilation External Control Setting In addition to the automatic damper open/close function, open/close control via external devices is now possible, delivering a By-pass ventilation system that is suitable to the installed environment. Control devices (example) Temperature sensor Humidity sensor Timers Exhaust air "By-pass" operation Damper Return air Fresh air Supply air LOSSNAY core Establish the wire connection by inserting the optional remote display adaptor (PAC-SA88HA-E) in the connector CN16 (Ventilation mode selector). With SW1 is ON, the ventilation mode of LOSSNAY is changed to the By-pass ventilation regardless of the setting on the remote controller. SW1 SW1: By-pass ventilation operation switch (When closed: For By-pass ventilation operation) Remote display adaptor (Optional) PAC-SA88HA-E Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Not used. Insulate completely. Max wiring length 1 m LOSSNAY control board CN16 Fan speed/ Ventilation mode selection Automatic ventilation setting The automatic damper mode automatically provides the correct ventilation for the conditions in the room. The following shows the effect By-pass ventilation will have under various conditions. 1. Reduces cooling load If the air outside is cooler than the air inside the building during the cooling season (such as early morning or at night), By-pass ventilation will draw in the cooler outside air and reduce the cooling load on the system. 2. Night purge By-pass ventilation can be used to release hot air from inside the building that has accumulated in buildings a business district during the hot summer season. 3. Office equipment room cooling During cold season, fresh air can be drawn in and used as is to cool rooms where the temperature has risen due to the use of office equipment. * When the outdoor air tempereture drops lower than 8ºC it changes to the heat exchange ventilation. (Display of the remote controller does not change) * In the case of By-pass ventilation, the supply air temperature slightly rises more than the outside air temperature because of the heat effect around the ducts or the unit motors. CO2 Sensor The system allows you to measure CO2 density and thereby control the amount of fresh air supplied. By connecting a CO2 sensor to the connector CN16, which is added to the LOSSNAY main unit, the setting can be switched to,, or Extra operation, which is selected when the sensor is turned ON. This system produces additional energy conservation. CO2 density Fan speed CO2Sensor CO2 density Fan speed Extra- CO2Sensor Air volume can be set using a pin position. To force fan speed externally CO2 sensor, etc. (When CO2 increases: Closed) SW1 SW1: fan speed operation switch (When closed: For fan speed operation) Remote display adaptor (Optional) PAC-SA88HA-E Brown 1 Red 2 Orange 3 Yellow 4 Green 5 Not used. Insulate completely. Max wiring length 1 m LOSSNAY control board CN16 Fan speed/ Ventilation mode selection When SW1 is "ON", fan speed of the LOSSNAY will be set to ""(Extra-) regardless of the remote control setting. Use this in such a way that it ventilates at or Extra- fan speed normally, and when the external sensor detects contamination of indoor air, it changes to (Extra ) fan speed operation. 4

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 8 Multi-ventilation Mode enables the appropriate supply/ exhaust balance to be selected to suit the usage environment and location Featuring "Multi-ventilation Mode," which allows the air supply/exhaust balance to be varied dynamically. The supply/exhaust balance can be selected to suit the usage environment and location, such as allowing for air exhausted via extractor fans. Modes can be selected easily by setting the connectors on the circuit board. Control switch Hand-held remote control for microprocessor type Ventilation mode Power air supply/exhaust mode Power air supply mode Power air exhaust mode Energy-saving ventilation mode * " notch" can also be further set to "Extra " using the unit switch. Unit setting * Factory setting is "" for both supply and exhaust. Supply airflow Exhaust airflow Air supply Air exhaust Offers choice of 9 air supply/exhaust combination patterns. Air supply and exhaust are "" irrespective of unit setting. Normal office, etc. Smaller offices or tenant buildings, etc. Smoking areas, etc. Providing efficient ventilation while maintaining air supply/exhaust balance... Using LOSSNAY compensates for using extractor fans... Priority on air exhaust... Power air supply /exhaust Power air supply Power air exhaust New Remote Controller PZ-6DR-E A new remote controller for the RX5 series is now available. In addition to boosting the energy conservation performance of the main unit, the remote controller features a variety of new functions which also pursue additional energy conservation. The appearance of the remote controller conforms to Mitsubishi air conditioner interface design standards. Functions that were set using Dip-Switch on the LOSSNAY main unit can now be configured as needed using the new remote controller. This eliminates the need to crawl under the eaves to change operation settings. Also, a newly adopted dot matrix display provides much more information, making it easy to check maintenance indications, operation status display, and explanations required when configuring settings. Dot matrix display ON/OFF button Fan speed Adjustment button Button CLR button Filter button Return button Timer MENU (MONITOR/SET) button Set time buttons Back Ahead OPERATION buttons Back Ahead Function selector button Timer ON/OFF (DAY) button "Extra " fan speed button OPERATION button 5

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 9 Newly Adopted Dot Matrix Display Available in Eight Languages ARIAESTERNA ITALIANO VENTILATION ENGLISH e Geblasebetrieb Deutsch VENTILACIoN ESPANOL VENTILATION FRENCH Energy Saving by Air volume level can be set hourly (max 8 times) and weekly. You can pre-set air volume according to the predictable requirement so that LOSSNAY can automatically operate at only necessary air-speed at the specified time period, which saves power consumption while maintaining the indoor air quality. Besides, once the weekly timer has been set, no switching on-off is required. timer Example A (Hourly) current RX4 series with PZ-41SLB controller 8: new RX5 series with PZ-6DR-E 8: 9: 12: 13: 17: 19: 22: low high low high low extra low Example B (Weekly) high Tolal power consumption in one day : LGH-1RX4-E : 6,6W (14 hours) LGH-1RX5-E : 5,39W (14 hours) Monday to Thursday 1,21W (18%) less 22: 8: 9: 12: 13: 17: 19: 22: low high low high low extra low Friday Saturday to Sunday 8: 9: 12: 13: 17: 22: low high low high extra low 8: 22: extra low Energy Saving by Night Purge Function During the summer season, the Night Purge function draws cooler outside air into the room to suppress temperature rises at night. This energy conservation function reduces the load when air conditioning is started the next morning. While air conditioning and ventilation are not operating, the room temperature rises as a result of heat from the skeleton and equipment. When the outside temperature becomes lower than the room temperature, ventilation starts automatically. When the room becomes sufficiently cool, ventilation is stopped. At night, the outside temperature drops. Hot air is discharged. The air conditioning load required to reach the set temperature the next morning is reduced. The out door temperture () setting can be selected either 17 C or 28 C by using Dip-Switch (SW2-7) in the LOSSNAY control box. Refer to the Instillation Manual for more information. *Do not use the night purge function if fog and heavy rain is expected. The entry of rain water may occur in the night. 6

28.LOSSNAY**2.qxd 11/14/8 5:1 PM Page 1 Control The New Remote Controller PZ-6DR-E enable simple control setting Interlocked with City Multi Interlocked with Air conditioners Interlocked with Mr.Slim LOSSNAY independent M-NET transmission line Slim-LOSSNAY connection cable LOSSNAY RX5 (Max unit) City Multi LOSSNAY RX5 Mr.Slim LOSSNAY RX5 LOSSNAY remote controller PZ-6DR-E can be connected PZ-52SF-E can be used insted of PZ-6DR-E, However, function is limited and connecting position is different. The LOSSNAY remote controller (PZ-6DR-E, PZ-41SLB-E) can not be used with this system. LOSSNAY remote controller PZ-6DR-E PZ-41SLB-E can be connected however function is limited. Centralized Controller System Centralized controller AG-1A Outdoor unit Interlocked with City Multi indoor units Power supply unit (PAC-SC51KUA) Indoor unit Network remote controller LOSSNAY RX5 LOSSNAY remote controller PZ-6DR-E Indoor unit Network remote controller Interlocked with Mr. Slim indoor units Mr.Slim outdoor unit Mr.Slim indoor unit LOSSNAY RX5 Mr.Slim remote controller LOSSNAY units only LOSSNAY RX5 LOSSNAY remote controller PZ-6DR-E LOSSNAY RX5 LOSSNAY remote controller PZ-6DR-E LOSSNAY RX5 Ext. signal source Interlocked with external devices LOSSNAY remote controller PZ-6DR-E 7

28.LOSSNAY**2.qxd 11/14/8 5:3 PM Page 11 Can Be Used With AG-1A Centralized Controller Controllers are one of the most important and familiar devices in an air conditioning system. Not only does it control to provide optimum air environment but supports operations to minimize running costs and to preserve energy. Through studies and development, we've visualized a new system controller meeting needs with versatile options. With a new coloured touch panel, new functions, and continuation of all the current G-A functions, AG-1A visualizes its functions from basic control to advanced operations and bringing an ultimate controller to reality. Design your control with our new centralized controller; AG -1A. System structure M-NET Switching Hub LAN (1BASE-TX) M-NET M-NET adapter A Control Remote Monitoring PC AG -1A Remote monitoring via a Web browser Power supply unit (PAC-SC51KUA) General Equipment Hub Hub M-NET DIDO Controller (PAC-YG66DCA) Temp/Humidity sensor AI Controller (PAC-YG63MCA) Lights Ventilation Watt hour meter Central Control PC (TG-2A) *Ver. 5. or later AG-1A / GB-A PI Controller (PAC-YG6MCA) Service company /Sales office VPN Router Modem Note : Use a security device such as a VPN router when connecting the AG-1A to the Internet to prevent unauthorized access. Internet Modem VPN Router Mobile phone of service person Remote monitoring PC Remote monitoring via a Web browser Functions Item Controllable unit ON/OFF Operation mode switching Temperature setting Fan speed setting Air flow direction setting Schedule operation Permit / Prohibit local operation Indoor unit intake temperature Error Test run Ventilation interlock External input/output Up to units/groups. Description Run and stop operation for the air conditioner units and general equipment. (To operate general equipment, PAC-YG66DCA is required.) Switches between Cool / Dry / Auto / Fan / Heat. (Group of LOSSNAY unit : automatic ventilation/ vent - heat interchange/ normal ventilation) depending on the air conditioner unit. Auto mode is for City Multi R2 and WR2 series only. Cool/Dry : 19 (67 ) - 3 (87 ) [14 (57 ) - 3 (87 )] Heat : 17 (63 ) - 28 (83 ) [17 (63 ) - 28 (83 )] Auto : 19 (67 ) - 28 (83 ) [17 (63 ) - 28 (83 )] [ ] in case of using middle-temperature on PDFY, PEFY-VML/VMR/VMS/VMH-by setting DipSW7-1 to ON. Yet, PEFY-P-VMH-E-F is excluded. Models with 4 air flow speed settings: Hi/Mid-2/Mid-1/ Models with 3 air flow speed settings: Hi/Mid/ Models with 2 air flow speed settings: Hi/ Fan speed setting (including Auto) varies depending on the model. Air flow direction angles, 4-angle or 5-angle Swing, Auto (Louver cannot be set) Weekly schedule can be set by groups based on daily operation pattern. Individually prohibit operation of each local remote control function (Start/Stop, Change operation mode, Set temperature, Reset filter). Measures the intake temperature of the indoor unit only when the indoor unit is operating. When an error is currently occurring on an air conditioner unit, the afflicted unit and the error code are displayed. This operates air conditioner units in test run mode. The ventilation unit (LOSSNAY) is able to automatically start its operation when operation of the interlocked indoor unit starts. By using optional external input/output adaptor (PAC-YG1HA) you can set and monitor the following. Input : By level signal : "Batch start/stop", "Batch emergency stop" By pulse signal : "Batch start/stop", "Enable/disable local remote controller" Output : "Start/stop", "Error/Normal" : Each unit : Each group : Each block : Each floor : Collective : Not available Operations X X Display *NOTE: Operation and displayed content vary depending on the indoor unit model. 8

28.LOSSNAY**2.qxd 11/14/8 5:6 PM Page 12 List of Remote Controller Settings and Functions The remote controller provides a wide range of functions and features other than the main functions described above, such as sophisticated energy conservation control and an easy to see, easy to use interface. Function(Communicating mode) New Function Extra low fan speed (Except LGH-1RX5 and 2RX5) Weekly timer Simple timer Night Purge mode Multi languages display 24-hours ventilation (Except LGH-1RX5 and 2RX5) Operation function limit Clock display Contact number setting for error situation LOSSNAY core cleaning sign Air volume display by external signal Bypass display by external signal Possible setting from the controller in addition to unit Dip-SW setting Extra / switch setting Multi Ventilation mode Power supply / exhaust when operation starts Pulse input Inter locking mode Automatic recovery following power supply interruption Delay operation at heating or cooling start-up Operation output monitor Exhaust fan stop at outdoor air lower than -ºC Exhaust fan stop during defrosting,exhaust fan speed operation at outdoor air lower than -ºC Bypass automatic ventilation priority setting Filter cleaning sign Maintenance display Total operated hours Total LOSSNAY mode operated hours Error history Carry on function In the use of MELANS M-NET 2 controllers display "Central" indication(use prohibition) New Controller PZ-6DR-E (V Controlling) PZ-41SLB-E (V Controlling) (in unit setting) (in unit setting) (in unit setting) (in unit setting) only auto recover mode (in unit setting) (in unit setting) (in unit setting) (in unit setting) Connect ducts in two different directions (, side) PZ-52SF-E (M-NET) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) (in unit setting) Ducts can be connected in two different directions to the outdoor vents thanks to collars and aperture plates that can be interchangeably placed in two different positions. This flexibility allows for installations close to the surface of a wall and helps avoid cases where the stale air exhaust vent would be blocked by an obstruction of some kind. This makes both planning and installation that much simpler. Standard installation Installation with duct direction changed A space is necessary to prevent the influx of rainwater. Can be installed close to the surface of the wall. Avoid installations where the stale air exhaust aperture would be blocked by lighting or air conditioning units. Lighting, etc. Collar Aperture Plate Changing the duct direction able Remove the collar (factory-standard direction) and the side panel aperture plate and switch their placements. They are both equipped with screw stoppers making the switch extremely simple. The direction of the ducts can only be changed on the outside ( and ). The inside cannot be changed (SA and RA). The position of the suspension bracket is changed to improve workability. By attaching the suspension bracket in the center of the product, the suspension bracket does not need to be moved even when the product is mounted upside down. (Model LGH- to 65) / square duct (LGH-1 2R) / is square duct. This simplifies installation and reduces total installation time. 9

28.LOSSNAY**2.qxd 11/14/8 5:48 PM Page 13 Controllers LOSSNAY remote controller (PZ-6DR-E) 12 13 19 Source power requirement Number of LOSSNAY units controlled by PZ-41SLB-E Power received from a LOSSNAY unit, TM4 1-2 1 Unit: mm LOSSNAY remote controller (PZ-41SLB-E) LOSSNAY M-NET remote controller (PZ-52SF-E) 12 12 7 8 33 7 8 33 *Stock available only. Source power requirement Interface condition for transmission line Number of LOSSNAY units controlled by PZ-41SLB-E 48 Input voltage: 9VDC-VDC,.2A Power received from a LOSSNAY unit, TM4 1-2 Specialized transmission line: DC power+am modulation 1 Unit: mm *Stock available only. Source power requirement Interface condition for transmission line Number of M-NET controlled LOSSNAY 1 16 units controlled by PZ-52SF-E 48 Unit: mm Input voltage: 17VDC 3VDC,.2A Power received from an outdoor unit or a power supply unit via M-NET transmission line. M-NET transmission line: 3VDC+AMI signal (±5VDC) Filters Standard filter Replacement components for the standard air filter supplied with the LOSSNAY LGH main unit. - filter This high- filter (with 65% colorimetricity EU-F7) can be incorporated inside the LOSSNAY unit without the need to attach parts from other systems, as done to date. The main unit external dimensions are unchanged, and processing capacity ranges between 1m 3 /h and 2,m 3 /h. B B A C A C Model PZ-25RF8-E PZ-35RF8-E PZ-RF8-E PZ-65RF8-E PZ-8RF8-E PZ-1RF8-E Dimension (mm) A B C 333 399 47 433 451 565 6 183 183 218 243 243 2 Number of filters per set Supply Exhaust 2 2 2 2 2 2 2 2 2 2 2 2 Applicable model LGH-RX5-E,LGH-25RX5-E LGH-35RX5-E LGH-RX5-E LGH-65RX5-E LGH-8RX5-E,LGH-1RX5-E(2sets) LGH-1RX5-E,LGH-2RX5-E(2sets) Filter material Nonwoven filter Collection (EU-G3) Model PZ-25RFM PZ-35RFM PZ-RFM PZ-65RFM PZ-8RFM PZ-1RFM Dimension (mm) A 327 393 464 427 446 559 B 144 171 171 25 232 232 Number of filters per set 2 2 2 2 2 2 Applicable model LGH-RX5-E,LGH-25RX5-E LGH-35RX5-E LGH-RX5-E LGH-65RX5-E LGH-8RX5-E,LGH-1RX5-E(2sets) LGH-1RX5-E,LGH-2RX5-E(2sets) Filter material Non combustible fiber (Polyester polyolefin) (EU-F7) Incorporation into the main unit is simple, and filter changes can be performed via the main unit inspection opening. 1

28.LOSSNAY**2.qxd 11/14/8 5:11 PM Page 14 A Breath of Freshness in Restaur Restaurants A restaurant can never be too clean and its air never too fresh The atmosphere of a restaurant is crucial to securing customers and making them happy enough to come back for more. Cleanliness is the key to an attractive atmosphere and restaurants devote significant effort to ensuring the premises are sanitary. Sanitation and cleanliness, however, are not enough. No matter how clean a restaurant may look, if there are bothersome odors lingering in the air, all those efforts go to waste and the restaurant s clean image is tarnished. For these reasons, we invite restaurant owners to leave the air to LOSSNAY. LOSSNAY s superior ventilation capabilities ensure that every breath is a breath of freshness keeping guests happy. LOSSNAY also keeps owners happy with its remarkable heat recovery technology that supplies fresh outdoor air with minimal change to indoor temperature, saving on energy and expense. If it s LOSSNAY... Ventilators work to exhaust stale air and supply fresh, clean air free of the odors associated with cooking, cigarettes, and the people working and dining. Change in room temperature is kept to a minimum during ventilation thanks to the heat-recovery function. The ventilators operate very quietly so those in the midst of enjoying their meals will not be bothered by any excess noise. A large array of ventilators is available to match the layout of just about any restaurant. What would you most like to see improved in restaurants? 52.3% Improvement in overall cleanliness Others: No response Promotion of waste prevention: 5.4% Improvement in atmosphere: 6.5% Reduction of time required for food to reach the table: 12.% Improvement in employees attitude toward customer service: 2.5% 1996 Foodstuffs Consumption Monitor, Second Periodic Survey (Ministry of Agriculture, Forestry and Fisheries, Japan) 11

28.LOSSNAY**2.qxd 11/14/8 5:12 PM Page urants, Offices, and Schools Offices Schools Fresh air improving the overall quality of working life Many office buildings today are heavily insulated air-tight structures with little or no natural ventilation. The unnatural environment created by air conditioners without added ventilation is a breeding ground for bacteria. Factor this in with the accumulation of pollutants and odors in the form of cigarette smoke, formaldehyde, pollen, dust, and carbon dioxide, and the necessity of ventilation becomes ever more apparent. In fact, poorly ventilated buildings can give rise to Sick Building Syndrome, a malady that is known to cause headaches, sore eyes, itching, and concentration loss. This results not only in discomfort at best and sickness at worst for the building s occupants, but also the reduced productivity of the workforce. Fresh air, effectively ventilated throughout the building, is therefore essential to the overall quality of working life. If it s LOSSNAY... Creating the best possible environment for our children to succeed Children deserve all the help we can give for them to grow up healthy, happy, and prosperous. No matter how good a school s curriculum, no matter how positive and enthusiastic the teacher, a child who does not feel well will have a hard time learning. The constant flow of fresh air is nowhere as important as it is in our schools. In classrooms where large numbers of students are gathered for long periods of time, carbonic gases have the tendency to accumulate, decreasing the levels of oxygen that are vital for alertness and concentration. This is especially true during the winter months when windows tend to remain closed. LOSSNAY ventilates fresh outdoor air into classrooms to replenish the supply of oxygen and expels not only carbon dioxide, but also other pollutants and odors that inevitably sully the air. If it s LOSSNAY... Simultaneous forced-air supply and exhaust introduces fresh, outdoor air into the building, effectively ventilating even fully airtight structures. The continuous influx of fresh, outdoor air and the exhaust of stale, indoor air ensure that the indoor oxygen level is maintained at just the right balance for comfort and health. Multiple split-type units operate independently of one another, simplifying system set up and ensuring a layout that optimally matches nearly any office design. Occupants have the luxury of breathing fresh air at all times even in highly air-tight buildings. LOSSNAY operation can be interlocked with air-conditioning system operation. LOSSNAY s sound attenuation qualities prevent outside noise from penetrating into the room, helping to maintain a quiet environment for productive study. Heat that is commonly lost due to ventilation is collected and reused thanks to the LOSSNAY Core, reducing air conditioners energy load and cutting operating costs. Heat-exchange technology prevents fluctuations in temperature for significant energy savings when either heating or cooling a room. O2 concentration and deficiency O2 Concentration 21 1 5 21% Normal air 18% Safety minimum 16% Increased respiration and pulse 12% 1% 8% Dizziness, nausea,loss of Paleness of muscle strength skin, vomiting. Comatose (precursors Unconsciousness (death in 8min) to death) 6% Convulsions, respiration stops, death 12

28.LOSSNAY**2.qxd 11/14/8 5:12 PM Page 16 Specifications / Dimensions LGH- to 1RX5 LGH-1 and 2RX5 13

28.LOSSNAY**2.qxd 11/14/8 5:12 PM Page 17 LGH-RX5-E Model Frequency / Power source Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LOSSNAY ventilation Extra Extra.44-.46 96-11 1 42 1.2-1.7 1-82. 75. 73. 27.5-28.37-.38 8-9 1 42 6.6-7.1 65-7 82. 75. 73. 26.5-27.25-.25 53-59 11 31 3.6-4.1 35-4 84. 77.5 76.5 22-23.5 LGH-RX5-E Hz / Single phase 22-24V.14-. 3-35 7 19 1.4 14 85.5 81. 81. 18 2 Under.8A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 6dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra.45-.46 97-11 1 42 1.2-1.7 1-28.5-29.37-.38 81-91 1 42 6.6-7.1 65-7 27-28.25-.26 54-61 11 31 3.6-4.1 35-4 23-24.14-. 3-35 7 19 1.4 14 18-19 9 8 7 3 3 Hz/Single phase 22V Temperature exchange (Heating) (Cooling) 1mm dia pipe length 9 8 7 3 3 Hz/Single phase 24V Temperature exchange (Heating) (Cooling) 1mm dia pipe length 6 25 2 2m 6 25 2 2m 2 2 m 2 2 m m mh 2 O 1 5 Pa 1 1 Extra low 1 1 2 2 1m 5m mmh 2O 1 5 Extra low 1 2 3 4 6 7 1 2 3 4 6 7 (exhaust air outlet) Air exhaust fan 12 768 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13x2 oval) 65 RA (return air) (outside air intake) LOSSNAY core 13 78 Core, air filter, - Efficiency filter, fan, Maintenance space SA (supply air) Power supply cable opening 65 Air supply fan Maintenance cover filter(sold separately) attachment position 13 3 97.5 11 Pa 1 1 1 1 2 2 1m 5m 735 53 More than 6 1 ~2 12 Inspection opening 2 782 Control box 273 95 3 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 14

28.LOSSNAY**2.qxd 11/14/8 5:13 PM Page 18 LGH-25RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LOSSNAY ventilation Extra Extra.52-.55 113-129 2 69 8.2-8.7 8-85 79. 69.5 68. 26-27.47-.48 12-114 2 69 5.1-6.1-6 79. 69.5 68. 25-26.26-.27 56-62 5 43 2-2.5 2-25 81.5 74. 72.5 2-21.5.17-.18 36-42 29.9 9 83.5 77.5 76. 18-19 LGH-25RX5-E Frequency / Power source Hz / Single phase 22-24V 2 Under.9A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 1dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra.53-.55 1-131 2 69 8.2-8.7 8-85 26.5-27.5.47-.48 13-1 2 69 5.1-6.1-6 25.5-26.5.26-.27 56-63 5 43 2-2.5 2-25 2.5-22.17-.18 36-42 29.9 9 18-19 9 Hz/Single phase 22V 9 Hz/Single phase 24V 8 Temperature exchange 8 Temperature exchange 7 (Heating) 7 (Heating) 6 (Cooling) 6 (Cooling) mmh 2O 25 2 1 5 Pa 2 2 1 1 Extra low 1 1 2 2 3 3 1 dia pipe length 4m 3m 2m 1m 4 mmh 2O 25 2 1 5 Pa 2 2 1 1 Extra low 1 1 2 2 3 1 dia pipe length 4m 3m 2m 1m 4 1 2 3 4 6 7 8 9 1 (exhaust air outlet) Air exhaust fan 12 768 Position where duct direction change is possible Bypass damper plate Ceiling suspension fixture (4-13x2 oval) 65 RA (return air) 735 53 More than 6 1 ~2 12 Control box 273 Maintenance cover filter(sold separately) LOSSNAY core attachment position 63 78 63 95 3 3 142 16 782 3 1 2 3 4 6 7 8 9 1 (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space Inspection opening 2 SA (supply air) Power supply cable opening 65 Air supply fan Position where duct direction change is possible Air filters (EU-G3) Unit: mm

28.LOSSNAY**2.qxd 11/14/8 5:13 PM Page 19 LGH-35RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LOSSNAY ventilation Extra Extra.92-.92 195-212 3 97.8-16.3 5-16 8. 71.5 71. 32-32.74-.74 16-169 3 97 7.6-8.2 75-8 8. 71.5 71. 28.5-29.5.5-.51-116 21 58 2.5-3.1 25-3 85. 76.5 75.5 21.5-23.28-.3 58-69 1 32.9 9 88. 81.5 81. 18 LGH-35RX5-E Frequency / Power source Hz / Single phase 22-24V 29 Under 2.4A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 1dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra.93-.94 197-217 3 97.8-16.3 5-16 32.5-32.5.77-.77 164-173 3 97 7.6-8.2 75-8 29.5-3.5.51-.52-116 21 58 2.5-3.1 25-3 21.5-24.28-.3 58-69 1 32.9 9 18 9 8 Hz/Single phase 22V Temperature exchange (Heating) 9 8 Hz/Single phase 24V Temperature exchange (Heating) 7 3 7 3 6 3 25 3 2 (Cooling) 1mm pipe dia length 6 3 25 3 2 (Cooling) 1mm dia pipe length 2 2 3m 2 2 3m m m H 2 O 1 5 Pa 1 1 Extra low 1 1 2 2 3 3 4 4 2m 1m m m H 2 O 1 5 Extra low 2 4 6 8 1 12 14 Air exhaust fan (exhaust air outlet) 124 Position where duct direction change is possible Bypass damper plate 875 Ceiling suspension fixture 8 (4-13x2 oval) RA (return air) 874 6 921 (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space More than 6 1~2 124 LOSSNAY core 64 Inspection opening 2 SA (supply air) Power supply cable opening 8 Air supply fan 55 Control box 3 Maintenance cover filter(sold separately) attachment position 888 64 95 142 16 Pa 1 1 1 1 2 2 3 3 4 4 2m 1m 2 4 6 8 1 12 14 55 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 16

28.LOSSNAY**2.qxd 11/14/8 5:14 PM Page 2 LGH-RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LGH-RX5-E Frequency / Power source Hz / Single phase 22-24V LOSSNAY ventilation Extra Extra 1.2-1.25 255-286 139.3-.8 1-5 78. 69. 66.5 33-34 1.-1. 27-228 139 6.6-9.2 65-9 78. 69. 66.5 3.5-32.85-.85 175-19 39 18 4.1-6.1 4-6 81. 71. 68. 26.5-28.4-.4 8-95 18 1. 1 86. 78. 77. 19 32 Under 3.A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 16dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra 1.25-1.25 26-29 139.3-.8 1-5 34-35 1.-1. 21-23 139 6.6-9.2 65-9 31-32.5.85-.85 18-195 39 18 4.1-6.1 4-6 27-29.4-.4 8-95 18 1. 1 19 9 8 4 Temperature Hz/Single phase 22V exchange 9 8 4 Hz/Single phase 24V Temperature exchange 7 35 3 Enthalpy exchange (Heating) 7 35 3 (Heating) (Cooling) 6 mmh 2O 3 25 2 1 Pa 3 2 2 1 1 5 Extra low (Cooling) 2mm dia pipe length 6m m 4m 3m 2m 1m 6 mmh 2O 3 25 2 1 5 Pa 3 2 2 1 1 Extra low 2mm pipe dia length 6m 1 2 3 4 6 7 1 2 3 4 6 2 4 6 8 1 12 14 16 18 2 2 4 6 8 1 12 14 16 18 2 Air exhaust fan (exhaust air outlet) 124 Position where duct direction change is possible Bypass damper plate 875 Ceiling suspension fixture 65 RA (return air) LOSSNAY core 79 888 SA (supply air) Power supply cable opening 65 Air supply fan Control box Maintenance cover 3 filter(sold separately) attachment position 79 3 3 116 745 95 163 (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space More than 6 1~2 124 Inspection opening 2 192 28 m 4m 3m 2m 1m 7 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 17

28.LOSSNAY**2.qxd 11/14/8 5:14 PM Page 21 LGH-65RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LGH-65RX5-E Frequency / Power source Hz / Single phase 22-24V LOSSNAY ventilation Extra Extra 1.7-1.8 3-38 6 181 11.2-12.2 11-12 77. 68.5 66. 34-34.5 1.5-1.5 38-322 6 181 6.1-8.2 6-8 77. 68.5 66. 32-33 1.2-1.2 248-265 52 144 4.1-5.1 4-8. 7.5 68.5 28.5-31.5.6-.6 12-14 265 74.8 8 86. 78. 77. 22 4 Under 4.4A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 1dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra 1.7-1.8 3-385 6 181 11.2-12.2 11-12 34.5-35 1.5-1.5 31-335 6 181 6.1-8.2 6-8 32.5-33.5 1.2-1.2 2-265 52 144 4.1-5.1 4-28.5-3.5.6-.6 12-14 265 74.8 8 22-22.5 9 8 Temperature Enthalpy Hz/Single phase 22V exchange 9 8 Hz/Single phase 24V Temperature exchange 7 6 45 4 35 3 4 4 3 3 Enthalpy exchange exchange (Cooling) (Heating) 2mm dia pipe length 7 6 45 4 35 3 4 4 3 3 Enthalpy (Heating) exchange (Cooling) 2mm dia pipe length 6m mmh 2 O 25 2 1 5 Pa 2 2 1 1 Extra low m 4m 3m 2m 1m mmh2o 25 2 1 5 Pa 2 2 1 1 Extra low m 4m 3m 2m 1m 1 2 3 4 6 7 8 9 1 25 75 1 125 1 175 2 225 2 25 75 1 125 1 175 2 225 (exhaust air outlet) Air exhaust fan 133 Position where duct direction change is possible Bypass damper plate 895 Ceiling suspension fixture (4-13x2 oval) 7 RA (return air) 954 692 11 (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space More than 6 1~2 133 Inspection opening 2 SA (supply air) Air supply fan Control box Power supply cable opening Maintenance cover 7 386 95 LOSSNAY core 79 98 filter(sold separately) attachment position 79 192 28 2 3 4 6 7 8 9 2 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 18

28.LOSSNAY**2.qxd 11/14/8 5:14 PM Page 22 LGH-8RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LOSSNAY ventilation LGH-8RX5-E Frequency / Power source Hz / Single phase 22-24V Extra Extra 1.75-1.75 38-4 8 222 14.8-.3 145-1 79. 71. 7. 33.5-34.5 1.6-1.6 345-37 Weight (kg) 53 Starting current Under 3.8A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 16dB greater than the indicated value.(at Fan speed) 8 222 1.7-12.2-12 79. 71. 7. 32-33 1.45-1.45 3-34 7 194 8.2-9.7 8-95 8.5 72.5 71.5 3-31.6-.65 125-145 355 99 2 2 87.5 79.5 79.5 22 By-pass ventilation Extra Extra 1.75-1.75 38-4 8 222 14.8-.3 145-1 34.5-35.5 1.6-1.6 345-37 8 222 1.7-12.2-12 33-34 1.45-1.45 3-34 7 194 8.2-9.7 8-95 31-32.6-.65 12-145 355 99 2 2 22 9 8 7 Enthalpy Hz/Single phase 22V exchange (Heating) (Cooling) Temperature exchange 9 8 7 Enthalpy Hz/Single phase 24V Temperature exchange exchange (Cooling) (Heating) 6 mmh 2O 4 3 2 1 Pa 4 3 2 1 Extra low 2 4 6 8 1 12 2mm dia pipe length 1m 8m 6m 4m 2m 6 m m H 2 O 4 3 2 1 Pa 4 3 2 1 Extra low 2 4 6 8 1 1 1 2 2 3 3 Air exhaust fan (exhaust air outlet) 165 Position where duct direction change is possible Bypass damper plate 11 Ceiling suspension fixture (4-x2 oval) RA (return air) 14 69 136 2mm pipe dia length 12 1m 8m 6m 4m 2m 1 1 2 2 3 3 (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space More than 6 1~2 SA (supply air) Power supply cable opening 165 Air supply fan 389 Inspection 399 opening Control box Maintenance cover 95 LOSSNAY core filter(sold separately) attachment position 79 1144 79 242 258 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 19

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 23 LGH-1RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LGH-1RX5-E Frequency / Power source Hz / Single phase 22-24V LOSSNAY ventilation Extra Extra 2.3-2.4-535 1 278 16.3-17.3 16-17 8. 72.5 71. 36-37 2.1-2.1 445-475 1 278 1.2-11.2 1-11 8. 72.5 71. 34-35 1.7-1.7 3-38 755 21 5.6-6.1 55-6 83. 74. 73. 31-32.5.9-.9 175-2 4 1 1.8 18 87. 8. 79. 21-22 59 Under 4.6A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 17dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra Extra 2.3-2.4 51-5 1 278 16.3-17.3 16-17 37-38 2.1-2.1 46-485 1 278 1.2-11.2 1-11 35-36 1.7-1.7 365-395 755 21 5.6-6.1 55-6 32-33.9-.9 175-2 4 1 1.8 18 21-22 9 8 Hz/Single phase 22V Temperature exchange (Heating) 9 8 Hz/Single phase 24V Temperature exchange (Heating) 7 (Cooling) 7 (Cooling) 6 4 3 4 3 2mm dia pipe length 1m 6 4 3 4 3 2mm dia pipe length 1m 8m 8m 2 O m m H 2 1 Pa 2 1 6m 4m Extra low 2m 2 4 6 8 1 12 14 mmh 2 O 2 1 2 1 Extra low 2 4 6 8 1 12 6m 4m 2m 14 1 1 2 2 3 3 4 1 1 2 2 3 3 4 Air exhaust fan (exhaust air outlet) 165 Position where duct direction change is possible Bypass damper plate 11 Ceiling suspension fixture (4-x2 oval) RA (return air) 1231 917 1263 Pa (outside air intake) Core, air filter, - Efficiency filter, fan, Maintenance space More than 6 1~2 165 Inspection opening SA (supply air) Power supply cable opening Air supply fan Control box Maintenance cover 399 LOSSNAY core filter(sold separately) attachment position 79 1144 79 242 258 95 Position where duct direction change is possible Air filters(eu-g3) Unit: mm 2

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 24 LGH-1RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LGH-1RX5-E Frequency / Power source Hz / Single phase 22-24V LOSSNAY ventilation Extra 3.5-3.5 76-83 1 417 16.3-17.8 16-175 8. 72. 7.5 38-39 3.2-3.2 69-74 1 417 13.3-13.8 13-135 8. 72. 7.5 36-37.5 2.9-2.9 63-68 13 361 9.7-1.2 95-1 81. 72.5 71.5 33.5-35 Under 7.3A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 19dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra 3.5-3.5 765-835 1 417 16.3-17.8 16-175 39-4.5 3.2-3.2 695-745 1 417 13.3-13.8 13-135 37.5-39 2.9-2.9 635-685 13 361 9.7-1.2 95-1 35.5-37 9 Hz/Single phase 22V Temperature exchange 9 Hz/Single phase 24V Temperature exchange 8 8 7 (Cooling) (Heating) 7 (Cooling) (Heating) 6 4 4 6 4 4 3 3 3 3 (m mh 2 O) 2 1 (Pa) 2 1 1 1 2 2 (m mh 2 O) 1 2 3 4 6 7 Bypass damper plate Air exhaust fan 11 Ceiling suspension fixture (4-x3 oval) (exhaust air outlet) 14 69 27 69 145 RA (return air) (outside air intake) 27 SA (supply air) 11 Core, air filter, - Efficiency filter, fan, Maintenance space 1~2 27 Air supply fan Control box Maintenance cover Power supply cable opening LOSSNAY core 44 1144 filter(sold separately) attachment position 79 7 2 1 (Pa) 2 1 1 1 2 2 1 2 3 4 6 7 More than 6 Inspection opening 399 798 242 258 Air filters(eu-g3) 242 258 Unit: mm 21

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 25 LGH-2RX5-E Model Ventilation mode Fan speed Current (A) Power consumption (W) Air volume (mmh2o) (Pa) Temperature exchange Noise (db) Weight (kg) Starting current (m 3 /h) (L/s) Heating Cooling (Measured at 1.5m under the center of panel in an anechoeic chamber) LGH-2RX5-E Frequency / Power source Hz / Single phase 22-24V LOSSNAY ventilation Extra 4.8-4.8 135-11 2 556 16.3-16.8 16-165 8. 72.5 71. 39.5-4 4.2-4.2 91-98 2 556 1.2-1.7 1-8. 72.5 71. 37-38 3.4-3.4 7-785 8 439 6.1-6.6 6-65 83. 73.5 72. 32.5-34 118 Under 11.9A Less *The Air outlets noise (45 angle,1.5meters in front of the unit) is about 2dB greater than the indicated value.(at Fan speed) By-pass ventilation Extra 4.8-4.8 14-111 2 556 16.3-16.8 16-165 4.5-41 4.2-4.2 9-98 2 556 1.2-1.7 1-38-39 3.4-3.4 72-785 8 439 6.1-6.6 6-65 33.5-35 9 8 Hz/Single phase 22V 9 8 Hz/Single phase 24V 7 Temperature exchange (Heating) (Cooling) 7 Temperature exchange (Heating) (Cooling) 6 4 4 6 4 4 (m mh 2 O) 3 2 1 (Pa) 3 2 1 1 1 2 2 (m mh 2 O) 1 2 3 4 6 7 Bypass damper plate Air exhaust fan 11 Ceiling suspension fixture (4-x3 oval) (exhaust air outlet) (outside air intake) 1231 917 27 27 917 1272 RA (return air) SA (supply air) Core, air filter, - Efficiency filter, fan, Maintenance space Air supply fan Control box Maintenance cover 399 798 Power supply cable opening LOSSNAY core filter(sold separately) attachment position 44 79 7 3 2 1 (Pa) 3 2 1 1 1 2 2 1 2 3 4 6 7 11 More than 6 1~2 Inspection opening 27 1144 242 258 Air filters(eu-g3) 242 258 Unit: mm 22

28.LOSSNAY**2.qxd 11/14/8 5: PM Page 26 Wiring Diagrams LGH-RX5 to 1RX5 M2 SUPPLY FAN MOTOR BLACK GREY YELLOW (*2) C CN1 BROWN RED TAB3 TAB5 GREEN/YELLOW TM1 L TAB1 BLUE N TAB2 BROWN PE POWER SUPPLY 22-24V Hz Isolator L N M1 EXHAUST FAN MOTOR BLUE WHITE (*2) C CN9 CN1 CN7 BLUE RED TR YELLOW RED GM LS CN32 CN16 TH1() CN5 TH2(RA) TM3 X12 X11 6 7 8 By-pass or Delay2 monitor output 6, 7 Malfunction monitor output 7, 8 MAX 24VAC 1A 24VDC 1A MIN 22VAC 1mA 5VDC 1mA TM2 1 2 3 12V or 24V DC Mr.Slim (non-polar) 1 3 SW2 SW5 SA1 SA2 TB5 A External control input Unchanged a-conntact NOTE 1.TM1, TM2, TM3, TM4, TB5 shown in dotted lines are field work. 2.Isolator should be provided by the customer. 3.Be sure to connect the grounding wire. B S CN2 SW1 X1 CN6 TM4 Sheild Wire M-NET transmission MELANS cable 1 9 2 1 TB5(M-NET) A B S BROWN BROWN Operation or Delay1 monitor output MAX 24VAC 2A MIN 22VAC 1mA 24VDC 2A 5VDC 1mA PZ- 6DR-E M-NET *Attention transmission cable Sheild Wire With this product, the wiring installation method will vary according to the design of the system. 2nd or later main units Perform electrical installation to meet local electrical regulations.. Always use double insulated PVC cable for the transmission cables.. Wiring work must be performed by qualified professionals.. All supply circuits must be disconnected before obtaining access to the terminal devices. (*1) 2nd remote controller (Max.2remote controllers installable cable) 2nd LOSSNAY unit (Up to max units) Transmission cable (non-polar) *When the optional Remote Controller PZ-6DR-E is used as the M-NET System,connect it to 1 2 of TM4 terminal block,and connect M-NET transmission wire to A, B on TB5 terminal block. TM4 (*1) Optional Remote controller 2 (PZ-6DR-E) 1 2nd remote controller (Max.2 remote controllers installable) (*1)PZ-41SLB-E and PZ-52SF-E cannot be used when using PZ-6DR-E (*2) LGH-1RX5 has 2 capacitors per mortor as following drawing. M CN16 (Unchanged a-conntact) BROWN HI LO EXTRA-LO BY-PASS C C RED YELLOW GREEN 23 Definition of Symbols *Specifications may be subject to change without notice. M1: Motor for exhaust fan CN1: Connector (Transformer primary) M2: Motor for supply fan CN2: Connector (Transformer secondary) C: Capacitor CN5: Connector (Thermistor) GM: Motor for By-pass operation CN6: Connector (Microswitch) LS: Microswitch CN7: Connector (Motor for By-pass operation) TH1: Thermistor for outside air TAB3: Tab connector(fan motor) TH2: Thermistor for return air TAB5: Tab connector (Fan motor) SW1: Switch (Main/Sub change) CN9: Connector (Fan motor) SW2, 5: Switch (Function selection) CN1: Connector (Fan motor) TM1: Terminal block (Power supply) CN16: Connector (//By-pass switch) TM2: Terminal block (External control input) CN32: Connector (Remote control selection) TM3: Terminal block (Monitor output) SA1: Address setting rotary switch (1 digit) TM4 : Terminal block (Transmission cable and monitor output) SA2: Address setting rotary switch (1 digit) TB5 : Terminal block (M-NET Transmission cable) SYMBOL : Indicates terminal block. TAB1,TAB2: Connector(Power supply) : Connector. : Board insertion connector or fastening TR1: Control circuit transformer connector of control board. X1,X11,X12: Relay contact