Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Similar documents
LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

CONTENTS. Ventilation for Healthy Living. Lossnay Construction and Principle. General Technical Considerations. System Design Recommendations

Heat pump and energy recovery systems

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

CONTENTS. Lossnay Unit

Whole Home Heat Recovery Ventilation

Heat Recovery Units. Heat Recovery 1

Bill McCullough. Director ERV Products. Dallas, TX

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Residential-Use Lossnay

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

250mm dia straight pipe length SP4 SP3. Air volume

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

Fundamentals of Psychrometrics. By James L. Murphy, Colorado Building Environments Sales Engineer

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

Lossnay. Total Heat Exchangers

Munters Heat Exchangers

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

EU Air Handling Units with SEMCO EXCLU-SIEVE

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

Designing Energy Efficient Outdoor Air Systems

INSTALLATION INSTRUCTIONS ERVR-A3D-X ERVR-C3D-X RETROFIT ENERGY RECOVERY VENTILATOR

Lossnay RVX Fresh Series Air Ventilation

Energy Recovery Ventilators

CHAPTER 4. HVAC DELIVERY SYSTEMS

Review on Waste Heat Recovery Techniques in Air Conditioning Application

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Wall Mounted Air Conditioners with Gas Heat Models AVGA

Scholar III Unit Ventilator

Standards and Guidelines. Presented by: Aric Murray December 12, 2014

TECHNICAL SPECIFICATIONS

DES CHAMPS PRODUCTS 85% 4,400 CFM

MODEL TRC TOTAL RECOVERY FOR ALL CLIMATES - COMMERCIAL APPLICATIONS

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

Liquid Desiccant Air Conditioning Systems

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WGERV-A3A WGERV-C3A WGERV-A5A WGERV-C5A WGSERV-A5 WGSERV-C5

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

GreenPac & GreenPac HGR Heat Pumps & Air Conditioners Models AVP

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

Air System Sizing Summary for AHU/CU-1 Project Name: Wilton Manors Fire Station#16 06/26/2016 Prepared by: L.N.I.

Submittal Data Performance Data Electrical Data

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Energy-Saving Technology for Multi Split-Type Air-Conditioning Systems for Buildings

Air System Sizing Summary for Lobby System Project Name: Existing Lobby 04/04/2005 Prepared by: psuae

AHRI Guideline W (I-P) 2014 Guideline for Selecting, Sizing, & Specifying Packaged Air-to-Air Energy Recovery Ventilation Equipment

Psychrometrics. Outline. Psychrometrics. What is psychrometrics? Psychrometrics in daily life and food industry Psychrometric chart

AIR HANDLING THERMAL CONDITIONS

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST MODELS: WFERV. Bard Manufacturing Company, Inc.

RT-OA TM Rooftop Outdoor-Air (DOAS)

Classic 13 Heat Pumps High Efficiency Vertical Packaged Heat Pumps Models HVPA and HVPSA

INSTALLATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST

SMART ERV Energy Recovery Ventilator. Build It Tight / Ventilate It Right!

Beijing Holtop Artificial Environment Technology Co., Ltd

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

OPERATION INSTRUCTIONS ENERGY RECOVERY VENTILATOR WITH EXHAUST. For Use With Bard 2 Through 5 Ton QW*S Series

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

» WITH REGASORP ROTARY HEAT EXCHANGER

Recent Advances in Energy, Environment and Economic Development

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Roof top SPACE RPC 450Z R407C M011

Tech to Tech May 07 HRV s & ERV s

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Comfort Series. Energy Recovery Ventilator. Why Fresh Air Ventilation is Vital for Today s Energy-Efficient Homes

Trane CDQ Desiccant Dehumidification

Impact of Multi-Stage Liquid Desiccant Dehumidification in a Desiccant and Evaporative Cooling-Assisted Air Conditioning System

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Rotors overview. Quick guide GOST VDI 6022

A Glossary of HVAC Terms

GreenPac & GreenPac HGR Air Conditioners Single stage models AVPA and HVEA and 2-stage models HVESA

Fresh Air Ventilation

Fresh Air Ventilation

Q-Tec TM QC-Series Chilled Water Air Conditioner

Basic Principals of Air conditioning By Dr. Esam Mejbil Abed

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

TDSHS Air Change Requirements and the Basics of Psychrometrics. Presented by: Aric Murray December 06, 2013

Ventilation. Technical Data. Heat Reclaim Ventilation EEDEN HRV design guide

P.O. Box 2758 Windsor, Nova Scotia, B0N 2T0 Ph Fax:

Central Heating and Ventilation

INSTALLATION INSTRUCTIONS WALL MOUNT ENERGY RECOVERY VENTILATOR WITH EXHAUST

MiniCore Ventilator (500, 1000) Series Engineering Guide

Service Step by Step Trouble-Shooting Check-List

Section 4 of 6 DOAS Core Technologies

RSES Technical Institute Training Manual 2 72 hours, 72 NATE CEHs, 7.2 CEUs

Temperature Distribution of Rotary Heat Recovery Units

Heat Recovery Ventilator. LG ventilation system for clean and comfortable indoor life!!! Eco V TM

Roof top SPACE RPC 315Z R407C MA00

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Ventilation. Technical Data. HRV design guide EEDEN HRV design guide

I-TEC ERV Economizer Ventilator System (Vent Code "E")

Transcription:

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV) 1

Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay Lossnay Core history / development and future 2

Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay Lossnay Core history / development and future 3

Why Heat Recovery Ventilator is required IAQ has become one of the most important topics on a worldwide level. * IAQ = Indoor Air Quality Today many people spend most of the time indoor (Office / factory worker, shop retailer, etc.,). - Bad IAQ reduces comfort. - Bad IAQ affects health and well-being. - Bad IAQ makes people feel lethargic and tired. - Bad IAQ may result sick building syndrome / allergic reaction / substance sensitivity risks 4

Why Heat Recovery Ventilator is required Sick building syndrome 4/Mar/2003 Asahi newspaper 24/Jan/2003 Asahi newspaper 5

Why Heat Recovery Ventilator is required Sick building syndrome 29/May/2013 The Sun 19/Mar/2013 Oriental Daily 6

CO2 Concentration (x1000ppm) CO2 Concentration (x1000ppm) Why Heat Recovery Ventilator is required Example: Madison Public School in the U.S. Without Ventilator CLASSROOM With Ventilator CLASSROOM Ventilator turned off 1,000 ppm CO2 LIMIT 1,000ppm CO2 LIMIT School Hours School Hours HOURS HOURS -The ventilator manages to keep the CO2 level under 1,000ppm High CO2 concentration may cause fatigue and affect your ability to concentrate. 7

Why Heat Recovery Ventilator is required Example: Office Building Air-conditioner Stale Air Heat Energy Ventilator or window Fresh Air Mechanical ventilation is important, however, it is waste of energy because it exhausts air-conditioned air... What is the solution.? Aha! HRV is! 8

Why Heat Recovery Ventilator is required Example: Office Building Air-conditioner Fresh Air Heat Energy Stale Air HRV!! Stale Air Heat Energy Fresh Air HRV Recovers Energy! (Temp. and Humidity)! 9

Why Heat Recovery Ventilator is required Cooling load example in summer Type of Load Indoor infiltration load Indoor generated load Outdoor air load Heat from walls Heat from glass -from direct sunlight -from conduction & convection Accumulated heat load in walls Generated heat from people -Sensible heat -Latent heat Generated heat from electrical equipment (lighting etc.) -Sensible heat Sensible heat Latent heat Estimated Load [W/m 2 ] 47.6 26.4 30.0 53.0 Total ------ 157.0 Outdoor air load 53.0W/m2 33.8% Indoor generated load 56.4W/m2 35.9% Indoor infiltration load 47.6W/m2 30.3% Energy loss caused by ventilation Conditions Outdoor air: DB 33 C, RH 63% Indoor air: DB 26 C, RH 50% Ventilation volume: 25m3 /Hr/person Middle floor of a general office building facing south 10

Why Heat Recovery Ventilator is required Lossnay principle Supply fan Lossnay Core (Heat Recovery unit) Exhaust fan SA (Supply Air) [Supply air goes out] EA (Exhaust Air) [Exhaust air goes out] RA (Return Air) [Exhaust air intake] OA (Outdoor Air) [Outdoor air intake] 11

Why Heat Recovery Ventilator is required OA (Outside air) EA (Exhaust air) Exhaust fan 2 of Lossnay cores Damper Filters Maintenance cover Supply fan Control box (circuit board) SA (Supply air) 12

Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay Lossnay Core history / development and future 13

Type of HRV Static type Exhaust Supply Rotary type Supply Indoor Outdoor Indoor Outdoor Exhaust Type Method Material Static Conductive transmission Metal/ plastic/ Paper Rotary Heat / Humidity accumulation Metal/ plastic/ Paper Heat pipe Heat / Humidity accumulation - Rotary and Static type is majority in HRV MITSUBISHI ELECTRIC is the origin of the static type enthalpy recovery core 14

Type of HRV Static type Construction & Principle Indoor Outdoor Partition Plate Spacer Plate General materials for core -Aluminum -Copper -Plastic/ polymer -Paper MITSUBISI ELECTRIC 15

Type of HRV Rotary type Construction & Principle Rotor - A layered honeycomb structure made of paper applied moisture absorbent material. Exhaust Air Fresh air is purged at a purge sector to prevent air leakage from exhaust air to fresh air. Fresh Air Purge Sector Heat and humidity of fresh air is absorbed by the rotor and as the rotor is rotating, it moves into the exhaust air and discharged to outdoor. (In summer case) Exhaust air and fresh air go through the same passage. Drive Motor Rotor rotates by a drive motor. (8rpm) 16

Type of HRV Air leakage and Bacteria return is a problem of Rotary Return Air Exhaust Air Purged Air Bacteria returned! Fresh Air Supply Outdoor Fresh Air Lower ventilation rate than actual performance of blowers. Strong possibility of bacteria return! 17

Type of HRV Item Static-type Lossnay Wheel type Construction Static transmission type. As the supply air and exhaust air pass through different passage, the air passages are completely separated. Heat and humidity accumulation type. Supply air and exhaust air flow into the same air passage because of its rotarytype construction. Moving parts None: Fixed core Used (rotor driven with belt by gear motor) Rotor core(8rpm). Air leakage Gas transmission Bacteria Gas transmission (Ammonia 2.8%) Gas transmission (Ammonia: 45-57%) Low (As air intake/exhaust are separate, transmission is low. High (As air intake/exhaust are the same, transmission is high) Space, size Core size and pressure drop become very big for large air volume unit. Difficult to arrange rotary core inside small size HRV. 18

Contents Why Heat Recovery Ventilator(HRV) is required Type of Heat Recovery Ventilator Feature of MITSUBISHI ELECTRIC Lossnay Lossnay Core history / development and future 19

Feature of MITSUBISHI ELECTRIC Lossnay Mitsubishi Electric Lossnay Core = Enthalpy Recovery Indoor Outdoor Enthalpy= Sensible Heat (Temp.) + Latent Heat (Humidity) -Sensible Heat => Heat conduction by temp. difference -Latent Heat => Vapor transition by vapor pressure difference 20

Feature of MITSUBISHI ELECTRIC Lossnay Heat Recovery Calculation [Summer example] Supply Air Lossnay (Enthalpy Recovery) Sensible HRV General Fan Exhaust Air D.B. ( C) 28 28 33 Model: LGH-100RVX-E A.H. (g/kg) R.H. (%) Enthalpy(kJ/kg) 13.3 56 62.1 20.1 84 79.5 20.1 63 84.6 Sensible efficiency: 76% Enthalpy eff. (cooling): 71% Ventilation rate : 1,000m3/h Recovered heat (kw) 7.5 1.7 0 Outdoor air load (kw) 3.1 8.9 10.6 OA load ratio (%) 29 84 100 Outdoor Air Indoor Air DB: 33 C DB: 26 C AH: 20.1g/kg (DA) Air Conditioner AH: RH: 10.5g/kg (DA) 50% RH: Enthalpy: 63% 84.6kJ/kg (DA) Enthalpy: 52.9kJ/kg (DA) 21

Absolute Humidity (g/kg (DA)) Feature of MITSUBISHI ELECTRIC Lossnay Heat Recovery Calculation [Summer example] Relative Humidity (%) Outdoor air load 100% 71% Recovered by Lossnay 100 90 80 70 60 50 40 Supply of Sensible HR 29% Outdoor 20.1 Psychrometric Chart Supply Exhaust 17.3 13.3 Return(Indoor) 10.5 10.0 0 10 Dry Bulb Temperature [ o C] 20 26 28 30 33 32 40 50 22

Feature of MITSUBISHI ELECTRIC Lossnay Type of MITSUBISHI ELECTRIC HRV Ceiling suspended -Air volume is 150 2000 m3/h -Ducting for 4 paths -Can be concealed behind the ceiling Cassette -Air volume is 150 500 m3/h -Ducting for 2 paths -Panel is exposed under the ceiling (Sold only in Japan) 23

Feature of MITSUBISHI ELECTRIC Lossnay Type of MITSUBISHI ELECTRIC HRV Wall mounted - Mainly residential use - 100m3/h - Install on the wall like air conditioner s indoor unit - Supply and exhaust air through 2 hole on the wall 24

Feature of MITSUBISHI ELECTRIC Lossnay Type of MITSUBISHI ELECTRIC HRV Ceiling suspended with humidifier and DX coil - Air volume is 500 and 1000m3/h - Supplemental heating / cooling by using with MTSUBISHI ELECTRIC air conditioning system - Connecting to water pipe for humidifying 25

Feature of MITSUBISHI ELECTRIC Lossnay Type of MITSUBISHI ELECTRIC HRV Floor standing - Outdoor installation possible (Applied models only) - Air volume 500-10000m3/h - Humidifier model, heating / cooling model existing 26

Feature of MITSUBISHI ELECTRIC Lossnay Type of MITSUBISHI ELECTRIC HRV Hong Kong school model - Strong fire proof construction - Ceiling suspended (Not concealed) 27

Contents Why Heat Recovery Ventilator(HRV) is required Feature of MITSUBISHI ELECTRIC Lossnay Type of Heat Recovery Ventilator Lossnay Core history / development and future 28

Lossnay Core history / development and future 1943 Nakatsugawa Works is Established 1945 Began manufacturing electric fans 1968 Began manufacturing duct fans First in Japan! 1970 Began marketing the Static enthalpy HRV Major innovation in dramatically decreasing the amount of energy wasted from conventional building ventilation! World s First! Original Lossnay Unit 29

Lossnay Core history / development and future The invention of Lossnay In 1969, Mr. Masataka Yoshino invented the principle of Lossnay. 30

Lossnay Core history / development and future The trigger of invention 31

Lossnay Core history / development and future Humidity transfers, and also gasses that are easily dissolved in water such as CO2, NO2 transfers. Ordinary Paper Higher humid air Water Vapor CO2 NO2 The contaminants passes through the plates during ventilation and returns to the room. Specially Treated Paper (Made of Cellulose Fibers) *for the former series Humidity transfers, but gasses such as CO2, NO2 do not transfer. Water Vapor Higher humid air CO2 Water Vapor NO2 CO2 Lower humid air NO2 Most of the contaminants do not return to the room during ventilation. Hyper Eco Core (Made of Specially Treated Cellulose Membrane) *For the Current Series More humidity transfers while the amount of gasses go through the plate decrease. Higher humid air Water Vapor Lower humid air Gas(CO2) Molecule The amount of air returning to the room decreases to less than 1%*, and the total heat exchange performance has been improved by the change of material. (*Tested by Mitsubishi Electric) Water Molecule Lower humid air 32

Lossnay Core history / development and future Hyper Eco Core <New adhesive> Our Patent Hyper Core Hyper Eco Core 33

Lossnay Core history / development and future Core future development for better energy recovery For better humidity efficiency + Absorbent material (Volume, selection) + Spacer Plate (Thinner plate) For better Temperature efficiency + Try to new construction of Air stream (Changing partition plate shape and material.) 34

Lossnay for school in Hong Kong Total over 20,000 units are installed. Lossnay units are supporting to Hong Kong Children s Education. 35