LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series REMOTE CONTROLLER. Function. Ventilation mode selection. Night-purge (fan speed)

Similar documents
LOSSNAY LINE-UP 250 CMH 50 CMH 150 CMH 100 CMH GUF. Series VL-220CZGV-E VL-100(E)U5-E, VL-50(E)S2-E REMOTE CONTROLLER. Function (Communicating Mode)

Residential-Use Lossnay

Introducing Lossnay. The diagram below provides an overview of how this process takes place inside of the Lossay system.

Whole Home Heat Recovery Ventilation

Lossnay RVX Fresh Series Air Ventilation

250mm dia straight pipe length SP4 SP3. Air volume

GUG-01SL-E GUG-02SL-E GUG-03SL-E

RVX SERIES State-of-the-art Lossnay heat exchange technology, reduces CO2 and saves energy.

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

Central Heating and Ventilation

SYSTEM 139 P indd 139 P indd :26:27 PM :26:27 PM

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

Ducted Air Conditioning

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

Ducted Air Conditioning

Fresh Air Ventilation

Fresh Air Ventilation

Ventilation. Product Information

GUG-01SL-E GUG-02SL-E GUG-03SL-E

WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

High Efficiency, Powerful Heating and Cooling HEAT PUMP PEH-7, 8, 10 AIR COOLED SPLIT-TYPE DUCTED AIR CONDITIONERS. Series

Air to Air Heat Exchanger

Leading edge reverse cycle air conditioning. Ducted and ceiling cassette

Ducted inverter reverse cycle air conditioning

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Hitachi Air Conditioning. Engineered for tomorrow. VRF Systems Ventilation GENERAL CATALOGUE

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

GUG-01SL-E GUG-02SL-E GUG-03SL-E

SELECT LOSSNAY. Select the most appropriate model according to factors such as the shape of the building and ventilation requirements.

Model : LGH-RVX-E TECHNICAL MANUAL. Comfortable air conditioning unit. Lossnay

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Inverter Ducted Air Conditioners

Technology that works fast. Inverter Ducted Systems

Heat Recovery Ventilation

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

RESIDENTIAL PREMIUM INVERTER DUCTED AIR CONDITIONING

Integrated VarIable refrigerant flow ahu/pau (r410a)

AIR CONDITIONING REVERSE-CYCLE INVERTER

ENERGY RECOVERY VENTILATORS. Fresh by nature Cleaner, healthier air from Lossnay

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

AIR CONDITIONING AGAIN, AGAIN & AGAIN ONLY PANASONIC GETS 5 STARS #AIRTHATMOVESYOU

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

INVERTER DUCTED SYSTEMS

Highly Efficient,Powerful Heating and Cooling.

Inverter Ducted Air Conditioners

Units without Remote Controller Units without Remote Controller Panel Units with Wireless Remote Controller

RX5 SERIES. C o n c e n t r a t i n g w h a t w e c a n d o. ENERGY RECOVERY VENTILATORS. m o r e, e v e r a n d d e f i n i t e l y...

Lossnay. Total Heat Exchangers

2 &3-4 Head Multi System

DESIGN & TECHNICAL MANUAL

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

TECHNICAL MANUAL. PACKAGED AIR-CONDITIONER (Split system, Air to air heat pump type) MULTI-TYPE (V-MULTI) PACKAGED AIR-CONDITIONER

Ceiling Mounted Cassette ( Round Flow with Sensing ) Type

Installation Instructions

SKYAIR SERIES SINGLE ZONE HEATING & COOLING SYSTEMS. Up to 20 SEER / Up to 12.0 HSPF / 14.5 EER INVERTER, VARIABLE-SPEED COMPRESSOR

. Creating Maximum Comfort

AIR-HANDLING UNIT (AHU) DESIGN GUIDELINE

Energy-saving operation

Air Conditioner CONTENTS

VENTILATION. Effective heat exchange and fresh air ventilation

STR-600 Impact Dryer

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

Ductless Mini-Split Systems. Comfort... where you need it, when you need it

PRODUCT RANGE: ROOFTOP PACKAGE

ultimate climate control and advanced energy efficiency THE ESP SERIES

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

P-SERIES PRODUCT CATALOGUE AIR CONDITIONER & HEAT PUMP

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

20% ENERGY RECOVERY VENTILATOR SUPPRESSES INDOOR TEMPERATURE CHANGES WHILE PROVIDING FRESH AIR

CONTENTS. Lossnay Unit

Just feel well. 2017/2018 Air conditioning

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

DESIGN & TECHNICAL MANUAL

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Blending Commercial and Residential. MiNi VRF

Domestic & Commercial Fans

Wrap Yourself in Comfort and Quiet Eco-conscious Technologies from Japan

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

USER MANUAL TPS-M5/M55/M555

Wired Remote Control MWR-WE10. Air Conditioner. user manual. imagine the possibilities. Thank you for purchasing this Samsung product.

Local air conditioner

Operation manual. Daikin Altherma low temperature monobloc EBLQ05CAV3 EBLQ07CAV3 EDLQ05CAV3 EDLQ07CAV3

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

JUNE & 3-4 Head Multi System

MSZ-L SERIESES. Luminous and Luxurious Design

ENG. IDEO 325 Ecowatt. Installation Manual

for Light Commercial Use

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

5) Do not start or stop the unit by inserting or pulling out the power plug.

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

CAREFULLY READ THESE INSTRUCTIONS BEFORE USING SAFETY PRECAUTIONS USE OF EXTENSION CORDS

Whole of Home ULTRASLIM. Ducted comfort, for when space is at a premium. That s better. That s Actron.

Come home to a warm welcome

Air to water Heat Pump System

Transcription:

27 SYSTEM

LOSSNAY LINE-UP Application 2 6 2 LGH-RVX Series LGH-RVXT Series Commerical Use GUF Series Optional Unit Dx-Coil unit for Lossnay LGH-RVX/RVXT Series GUG Series VL-22CZGV-E Residential Use VL-(E)U5-E VL-(E)S2-E VL-SR2-E LGH-RVX Series This commercially oriented system can be utilized virtually anywhere with high performance and functions. LGH-RVXT Series Thin large air volume models in LGH series with high performance and functions. Dx-Coil Unit (GUG Series) control equipment working with Lossnay unit and Mr. Slim outdoor unit. GUF Series Heat recovery with heating and cooling system using the heat resource of City Multi outdoor unit. VL-22CZGV-E Centralized ventilation for residential use with sensible heat exchange. VL-(E)U5-E, VL-(E)S2-E Wall mount models. Particularly suitable for houses and small offices. REMOTE CONTROLLER PZ-6DR-E 2 9 Function PZ-6DR-E PZ-4SMF-E (Communicating Mode) LGH-RVX/RVXT VL-22CZGV-E LGH-RVX/RVXT VL-22CZGV-E selection 4 fan speeds 4 fan speeds 2 of 4 fan speeds 2 of 4 fan speeds Ventilation mode selection Energy recovery / Bypass / Auto Heat recovery / Bypass / Auto (available with optional parts P-DUE-E) Energy recovery / Bypass / Auto Heat recovery / Bypass / Auto (available with optional parts P-DUE-E) Night-purge () Any schedule No No No 2 Night-purge (fan speed) Selectable from 4 fan speeds No No No Function setting from RC Yes Yes No No Unit (mm) Bypass temp. free setting Yes Yes (available with optional parts P-DUE-E) No No Heater-On temp. free setting Yes No No No Fan power change after installation Yes Yes No No On/Off r Yes Yes Yes Yes PZ-4SMF-E Auto-Off r Yes Yes No No Weekly r Yes Yes No No 5 Lower case Operation restrictions (On/Off, ventilation mode, fan speed) Operation restrictions (fan speed skip setting) Yes Yes (ventilation mode is available with optional parts P-DUE-E) No No Yes Yes No No Screen contrast adjustment Yes Yes No No 2 Language selection Yes (8 languages) Yes (8 languages) No (English Only) No (English Only) Initializing remote controller Yes Yes No No Filter cleaning sign Yes Yes Yes Yes Lossnay core cleaning sign Yes No No No Unit (mm) Error indication Yes Yes Yes Yes Error history Yes Yes No No 2

LOSSNAYSYSTEM Lossnay ventilation systems are renowned industry-wide for their efficiency. They offer environment-friendly energy recovery and humidity control, and enable air conditioning systems to simultaneously provide optimum room comfort and energy savings. Indoor Air Quality Inside a Building is Optimised Through and Humidity Exchange by Lossnay Lossnay is a total heat exchange ventilation system that uses paper characteristics to perform temperature (sensible heat) and humidity (latent heat) exchange. EA The concept of sensible heat and latent heat exchange using Lossnay core Outside Inside OA Exhaust air outlet (EA) Return air (RA) RA Outdoor air intake (OA) Supply air (SA) SA What can be Improved by Introducing Lossnay? Ventilation with maximised comfort In summer Air similar to the conditions of the cooled (dehumidified) indoor air is supplied. In winter Air similar to the conditions of the heated (humidified) indoor air is supplied. Supply air Dry bulb temperature (ºC) LOSSNAY Conventional ventilator Supply air Dry bulb temperature (ºC) LOSSNAY 6 Conventional ventilator Absolute humidity (g/kg'(da)) Relative humidity (%). 2. 6 Exhaust air Absolute humidity (g/kg'(da)) Relative humidity (%) 5.2 46.9 Exhaust air Enthalpy (kj/kg(da)) 62..6 Enthalpy (kj/kg(da)) 29.2 4.7 Total energy recovery (kw) 7.5 Total energy recovery (kw) 8.2 Outdoor air load (kw)..6 Outdoor air load (kw).. Outdoor air load ratio (%) 29 Outdoor air load ratio (%) Return air Outdoor air Return air Outdoor air Dry bulb temperature 26ºC Dry bulb temperature ºC Dry bulb temperature 2ºC Dry bulb temperature ºC Air conditioner Absolute humidity Relative humidity.5g/kg'(da) % Absolute humidity Relative humidity 2.g/kg'(DA) 6% Air conditioner Absolute humidity Relative humidity 7.g/kg'(DA) % Absolute humidity Relative humidity.9g/kg'(da) % Enthalpy 52.9kJ/kg(DA) Enthalpy.6kJ/kg(DA) Enthalpy.5kJ/kg(DA) Enthalpy 4.7kJ/kg(DA) Heat recovery calculation Indoor supply-air Outdoor temperature (ºC) = temperature (ºC) _ Outdoor temperature (ºC) _ Indoor temperature (ºC) Temp recovery efficiency (%) Heat recovery calculation Indoor supply-air Indoor = _ Outdoor temperature (ºC) temperature (ºC) temperature (ºC) Temp recovery efficiency (%) Calculation example: 6ºC = (2ºC _ ºC) % + ºC Calculation example: ºC = ºC _ (ºC _ 26ºC) 72% *The above applies to the case of LGH-RVX (fan speed 4). *The above applies to the case of LGH-RVX (fan speed 4). + Outdoor temperature (ºC) 29

Commercial Use Lossnay LGH-RVX (Standard model) Power consumption reduced further with introduction of a DC motor Realized low power consumption with introduction of a high efficiency brushless DC motor. Compared to models with an AC motor, power consumption is reduced. Comparison between new and previous power consumption (New model: 4 at 2V Hz, Previous model: Extra-High at 22V Hz) (W) (W) 5 4 4 Improved Air Volume Range Wide range air volume Each fan speed has a range setting of,, 75 and %, allowing much finer air volume control. When used in combination with the CO2 sensor or r function, the air volume can be controlled according to conditions that realize better performance and reduce power consumption. adjustment function The default fan speed value can be adjusted slightly. Use the PZ-6DR-E remote controller to reset the speed. ) Considering the total hours of Lossnay operation (filter clogging), the fan power can be adjusted automatically after a given period of. 2) After the unit is installed, when if the air volume is slightly lower than the desired airflow, it is possible to make fine adjustments. LGH-RVX/RVXT series model characteristic curves P-Q curve image Static pressure Offers a wide range of airflow variations, from fine to large volume Static pressure default + +2 + +4 % % 75% % 2 4 2 4 LGH-RVXT (Thinner body type) The LGH-RVXT series have a large air volume of - 2, but has a thin body @mm. Installing the unit behind the ceiling is easy. LGH-/RVX-E LGH-//2RVXT-E LGH-RVXT Installation image mm Height: 8mm Height: mm Ceiling GUF Series (Lossnay with Dx-coil unit) Along with Lossnay ventilation, the OA Processing Unit is really two units in one, functioning as the main air conditioner when the load is light and adding supplemental air conditioning when the load is heavy. OA (Outdoor air) Fresh, outdoor-air in a quantity required for ventilation is drawn in by the supply fan. EA (Exhaust air) Heat from the indoor air (both sensible and latent) is recovered by the Lossnay core and vented outside by the The exhaust fan exhaust fan. High efficiency filters (Option) The supply fan Heat recovery unit (Lossnay core) and humidity are exchanged between the supply air and the exhaust air. Maintenance cover Air filter Prevents clogs in the Lossnay core. Dx-coil Cools or heats the drawn in outdoor-air. RA (Return air) The exhaust fan draws in contaminated indoor-air. SA (Supply air) The processed, fresh outdoor-air is vented to the indoor rooms. 22

Commercial Use Lossnay Specifications LGH-RVX Series Electrical power supply Ventilation mode Running current (A) Input power (W) (m /h) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) Specific energy consumption class LGH-5RVX-E 22-V/Hz, 22V/6Hz.4 49 42 95 7 7. 54 8 75.5 74.5.5 4 75 2 8 9. 7 6 79 79 7.4 52 42 95 29 2 A. 54.5 4 75 2 9. 8 6 LGH-RVX-E 22-V/Hz, 22V/6Hz.48 62 2 85 79.5 68 27. 8 52 48 72 22.6 6 5 2 82 76 74.5 2. 7.5 6 7 5 86 8 8 7.48 6 2 85 27.5.29 5 8 52 48 2.6 7 5 2 2. 9 6 7 5 7 2 A LGH-5RVX-E 22-V/Hz, 22V/6Hz. 4 97 6 7.5 7 2.54 26 7 82.5 74 7.26 75 49 4 86.5 2.2 88 88.5 8.5 82 7. 45 97 6 2.5. 72 26 7. 5 75 49 4 2. 88 Electrical power supply Ventilation mode Running current (A) Input power (W) (m /h) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) LGH-RVX-E 22-V/Hz, 22V/6Hz.5 65 9 2 66.5 4.59 75 4 68 8 7 68.26 2 2 8.5 75 72.5 9. 2 5 8 87 82.5 82.5 7 9 2 5.59 8 75 4 68 29.27 5 2 2. 4 5 8 LGH-65RVX-E 22-V/Hz, 22V/6Hz.65 2 6 2 77 68.5 66 4.5. 488 5 68 8 7.5 29.9 49 76 74 22.5 5 6 45 8 86 82 8.72 262 6 2 5.5.86 488 5 68 29. 47 22.6 7 6 45 8 LGH-RVX-E 22-V/Hz, 22V/6Hz.82 5 222 79 7 4.5.8 5 6 67 85 82.5 7.5 72.5.6 6 4 2.5 85 8 8.97 4 222 6.86 5 6 67 85.4 64 4 2.5 2 48 Electrical power supply Ventilation mode Running current (A) Input power (W) (m /h) External static pressure (Pa) (%) Enthalpy exchange efficiency (%) (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) LGH-RVXT Series Electrical power supply Ventilation mode Running current (A) Input power (W) (m /h) Supply External static pressure (Pa) Return (%) Enthalpy exchange efficiency (%) (Measured at.5m under the center Noise (db) of unit in an anechoeic chamber) Weight (kg) GUF Series Electrical power supply Ventilation mode LGH-RVX-E 22-V/Hz, 22V/6Hz 2. 42 2 72.5 7 7.2 7 96 8 74 7. 75 9 4 86.5 77 2.7 2 2 89.5 87 85.5 2. 42 2.2 7 96 2.5 75 9 4.9 2 2 54 LGH-RVX-E 22-V/Hz, 22V/6Hz LGH-RVX-E 22-V/Hz, 22V/6Hz.7 6 47 75 72.5 9.75 82.5 7.5 72.5 2. 2 7.29 75 4 85 8 8.85 8 47 75 4.5.. 7 26. 75 4 4.88 8 5 72.5 7 4 2.2 4 47 8 74 7 6.88 5 2 86.5 77. 42 9 89.5 87 85.5 4.54 85 5 4 2.6 72 47 6.87 2 27.5 49 9 9 LGH-RVXT-E 22-V/Hz, 22V/6Hz LGH-RVXT-E 22-V/Hz, 22V/6Hz LGH-2RVXT-E 22-V/Hz, 22V/6Hz 4. 792 47 75 9.5 2.4 42.5 7 5.5. 76 7 8 7 72 29.5.6 48 75 4 6 8.5 75 74 22.4 6 47 75 9. 4.77 4 7 26.5. 7 75 4 6 2.5 5.4 5 75 72.5 9.5 2. 494 47 8 7.5 7 5.5. 97 2 82.5 77 74.5.9 9 6 8.5 22 5. 96 5 75 4.5 2.2 47 47 4.5.85 2 27.4 45 9 6 2.5 7.6 6 2 4 75 77 68 65.5 4.6 687 75 52 79 7.5 9.4 2 2 47.5 74 7.5 2.57 82 6 74 6 82.5 79 76.5 6. 2 2 4 75. 587 75 52.5. 22 2 47.49 6 74 6 22.5 59 GUF-RD4 22-V/Hz GUF-RD4 GUF-RDH4 GUF-RDH4 22-V/Hz 22-V/Hz 22-V/Hz High Low High Low High Low High Low High Low High Low High Low High Low Running current (A).5..5. 2.2.7 2..77.5..5. 2.2.76 2..77 Input power (W) -265-65 -265-65 4-5 -95 4-55 5-4 -265-65 -265-65 4-5 5-4 4-55 5-4 (m /h) 4 4 4 4 9 9 2 222 2 222 9 9 2 222 2 222 External static pressure (Pa) 4 4 4 4 5 86 5 86 (%) 77.5 79.5 8.5 77.5 79.5 8.5 Enthalpy exchange 68 7 7 74 68 7 7 74 efficiency (%) 65 67 7 65 67 7 capacity (kw) 5.57 (.94). (4.2) 5.57 (.94). (4.2) capacity (kw) 6.2 (2.4) 2. (4.26) 6.2 (2.4) 2. (4.26) Capacity equivalent to the indoor unit P2 P6 P2 P6 Humidifying Permeable film humidifier Humidifier Humidifying capacity(kg/h) 2.7 (heating) 5.4 (heating) Water supply pressure Minimum pressure : 2. 4 Pa Maximum pressure : 49. 4 Pa Noise (db) (Measured at.5m under the center of the unit).5-4.5 29.5-.5 5-6 29.5-.5-9 4-5 -9 5-6.5-4.5 29.5-.5 5-6 29.5-.5-9 4-5 -9 5-6 Weight (kg) 48 82 5 (filled with water 55) 88 (filled with water 96) For LGH-RVX and LGH-RVXT series *The running current, the input power, the efficiency and the noise are based on the rating air volume, and 2V/Hz. *For the specification at the other frequency contact your dealer. *Figures in the chart is measured according to Japan Industrial Standard (JIS B 86). Characteristic Curves are measured by chamber method. For GUF series */ capacity indicates the maximum value at operation under the following condition. : Indoor: 27 C DB/9 C WB Outdoor: 5 C DB/ C WB : Indoor: 2 C DB/.8 C WB Outdoor: 7 C DB/6 C WB *The figures in ( ) indicates heat recoverying capacity of heat exchange core. *Figures in the chart are measured according to Japan Industrial Standard (JIS B 86). Characteristic Curves are measured by chamber method. 22

Characteristic Curves LGH-5RVX-E LGH-RVX-E LGH-5RVX-E mm dia straight pipe length mm dia straight pipe length 2 2m 5m m 5m 6 6 2m 4 4 2 (m /h) 4 (m /h) 2 4 6 2 4 6 2 m LGH-RVX-E LGH-65RVX-E LGH-RVX-E mm dia straight pipe length mm dia straight pipe length 2 LGH-RVX-E LGH-RVX-E LGH-RVX-E 2mm dia straight pipe length 4m m 4m 2 6m 6 6 4m 2m 4 2m 4 4 6 (m /h) 2 4 6 (m /h) 2 4 6 2 4 6 2 4 6 2 4 6 22 26 m 6m 2 mm dia straight pipe length 4m m 2m m 4 2 4 6 (m /h) 2 2 4 6 2 4 6 6 2mm dia straight pipe length 4 6 m m 6 6m 4m 4 2 2 (m /h) m 2 6m 6 4m 2 (m /h) 2 4 4 2 2 2 (m /h) 4 6 6 4 2 2 2 (m /h) 4 6 6 4 LGH-RVXT-E LGH-RVXT-E LGH-2RVXT-E 4 4 2 Supply Return 6 4 4 2 Supply Return 6 4 4 2 Supply Return 6 2(m /h) 4 6 2 (m /h) 4 6 4(m /h) 4 6 GUF-RD4 GUF-RD4 GUF-RDH4 GUF-RDH4 6 Low High mm dia pipe straight length m m 6m 4m 2m 4 6 (m /h) 2 4 6 6 22 Air volume 2 4 6 Low High 2mm dia pipe straight length m m 6m 4m 2m 4 6 4 (m /h) 2 4 6 Low High mm dia pipe straight length m m 6m 4m 2m 4 6 (m /h) 2 4 6 6 22 Air volume 2 4 6 Low High 2mm dia pipe straight length m m 6m 4m 2m 4 6 4 (m /h) 2 4 222

Optional Dx-coil Unit for Lossnay Supply Comfortable Control Product Features Lossnay return air and supply air temperature control are possible with Dx-coil unit which is connectable with Mr. Slim (Power inveter series) Expand the product line-up of Lossnay with temperature control (-2,) by the connection of Dx-coil unit. Suitable for various applications such as offices, shops and schools etc. Target Application Application Examples ( ) Setting Temp. Dx-coil unit RC RA Control s setting range : 7- C / : 9- C / Auto: 9- C Target Temp. ( ) Setting Temp. Dx-coil unit RC RA Control s setting range : 7- C / : 9- C / Auto: 9- C Target Temp. ( ) Setting Temp. Dx-coil unit RC SA Control s setting range : 7- C / : 2- C Target Temp. *Example images of using LGH-RVXT series for reference only. 22

Flexible Installation Flexible Connection to Lossnay The length of the connection cable (accessory) between the Lossnay and Dx-coil unit is about 6m, so flexible installation is possible (two units can be installed close together or far apart with straight or bent ducting). To Keep High Static Pressure 2 P-Q curve image. Lossnay unit 2. Lossnay unit + Dx-coil unit. Lossnay unit (fan power up +4) + Dx-coil unit Dx-coil unit static pressure loss is kept to minimum, making it possible to maintain high static pressure using the fan power up function of the Lossnay. The fan power up function is only available when used with the PZ-6DR-E Lossnay remote controller. (m /h) Drain Pump Equipment A built-in drain pump makes, attaching the drain hose in the ceiling cavity easy, resulting in simple and fast installation. Max 5mm from the bottom of unit Max mm User-friendly System Control Flexible Remote Controller Selection (A) One remote controller Dx-coil unit remote controller ON/OFF / (B) Two remote controllers Lossnay remote controller ON/OFF Vent. mode ON/OFF / When using only one remote controller, the Lossnay fan speed is fixed at fan speed or 4. When using two remote controllers, all of Lossnay function is available. *: Both of Lossnay unit and Dx-coil unit will synchronously switch to ON and OFF. *2: When one of the two remote controllers is turned ON, the other remote controller turns ON synchronously. Dx-coil unit remote controller Priority Mode Selection priority mode (factory setting) or priority mode are selectable when Lossnay unit fan speed is controlled by a CO2-sensor or a BMS (analogue input (-VDC) or a volt-free input). *During fan speed or 2, the Dx-coil unit is always thermo-off Operation mode or Fan order Actual fan speed from external input Temp. priority priority FS4 FS4 FS4 FS FS FS FS2 FS FS2 FS FS FS FS4 FS4 FS4 FS FS FS FS2 FS2 FS2 FS FS FS 2

Specifications GUG Series GUG-SL-E GUG-2SL-E GUG-SL-E Refrigerant Electrical power supply Input power Running current Weight Function Connectable Lossnay unit Capacity [kw] SHF Performance index Air flow range at and Connectable outdoor unit Ext. piping Required optional parts Connectable Lossnay unit Capacity [kw] SHF Performance index Air flow range at and Connectable outdoor unit Ext. piping Required optional parts Connectable Lossnay unit [m /h] Air Volume [L/s] External static pressure [Pa] GUG-SL-E (Connection to LGH-RVX-E or LGH-65RVX-E) R4A 22-V / Hz, 22V / 6Hz (Supplied from outdoor unit) / Fan: 2.5W, : 2.4W Less than.a 2kg *Accessories: Approx. kg / / Auto / Fan *Auto is only available for RA temperature control 9 5 LGH-RVX-E 75 2 4 59 26 RA (Return Air) temperature control LGH-RVX-E 6.5 ( 2.4 + 4. ) 5.6 ( 2. +.6 ).66 4.9 4. - 5 m /h PUHZ-ZRP5 Diameter Liquid / Gas: 6.5 / 2.7 Maximum length: m, Maximum height: m 5 7 LGH-65RVX-E 7.7 (.2 + 4.5 ) 6.6 ( 2.6 + 4. ). 4.72 5. - m /h PUHZ-ZRP5 Diameter Liquid / Gas: 6.5 / 2.7 Maximum length: m, Maximum height: m 6 95 RA (Return Air) temperature control SA (Supply Air) temperature control GUG-2SL-E (Connection to LGH-RVX-E or LGH-RVX-E) R4A 22-V / Hz, 22V / 6Hz (Supplied from outdoor unit) / Fan: 2.5W, : 2.4W Less than.a 26kg *Accessories: Approx. kg / / Auto / Fan *Auto is only available for RA temperature control RA (Return Air) temperature control / SA (Supply Air) temperature control [Must be set at initial setting and not possible to change from remote controller] LGH-RVX-E. ( 4. + 6. ) 8. (. + 5. ). 4.62 4.76 - m /h PUHZ-ZRP Diameter Liquid / Gas: 6.5 / 2.7 Maximum length: m, Maximum height: m PAC-SHRJ-E and PAC-SHRJ-E LGH-RVX-E. ( 4. + 6. ) 8. (. + 5. ). 4.62 4.76 - m /h PUHZ-ZRP Diameter Liquid / Gas: 6.5 / 2.7 Maximum length: m, Maximum height: m PAC-SHRJ-E and PAC-SHRJ-E Ventilation specifications LGH-65RVX-E LGH-RVX-E 488 6 6 4 5 45 222 67 5 6 7 8 LGH-RVX-E.2 ( 5. + 8. ). ( 4.2 + 7. ).66 4.42 4. - m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m LGH-RVX-E.4 ( 5. + 6. ) 9.5 ( 4.2 + 5. ).7 5.9 5.4 - m /h PUHZ-ZRP Diameter Liquid / Gas: 6.5 / 2.7 Maximum length: m, Maximum height: m PAC-SHRJ-E and PAC-SHRJ-E, 2 LGH-RVX-E 7 9 7 2 8 Refrigerant Electrical power supply Input power Running current Weight Function Connectable Lossnay unit Capacity [kw] SHF Performance index Air flow range at and Connectable outdoor unit Ext. piping Connectable Lossnay unit Capacity [kw] SHF Performance index Air flow range at and Connectable outdoor unit Ext. piping Connectable Lossnay unit [m /h] Air Volume [L/s] External static pressure [Pa] GUG-SL-E GUG-SL-E (Connection to LGH-RVX-E or LGH-RVX-E) (Connection to LGH-RVXT-E, LGH-RVXT-E or LGH-2RVXT-E) R4A 22-V / Hz, 22V / 6Hz (Supplied from outdoor unit) / Fan: 2.5W, : 2.4W Less than.a kg *Accessories: Approx. kg / / Auto / Fan *Auto is only available for RA temperature control RA (Return Air) temperature control / SA (Supply Air) temperature control [Must be set at initial setting and not possible to change from remote controller] RA (Return Air) temperature control LGH-RVX-E 2.7 ( 7.7 +. ) 5.8 ( 6. + 9.5 ).68 4. 5.27-22 m /h PUHZ-ZRP Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: 75m, Maximum height: m LGH-RVX-E 6.6 ( 7.7 + 8.9 ).4 ( 6. + 7. ).85 5.46 5.2-22 m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m, 47 LGH-RVX-E, 7 75 4 9 LGH-RVX-E 2.8 (. +.5 ).4 ( 8.4 +. ).76 5.2 5.86-26 m /h PUHZ-ZRP Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: 75m, Maximum height: m LGH-RVX-E 9.5 (. + 9.2 ) 5.9 ( 8.5 + 7.4 ). 6. 5.85-26 m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m 2, 5 5 LGH-RVX-E,, 47 2 59 26 9 7 LGH-RVXT-E 2.4 ( 7.4 +. ) 5.7 ( 6.2 + 9.5 ).68 4.7 5. - 22 m /h PUHZ-ZRP Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: 75m, Maximum height: m SA (Supply Air) temperature control LGH-RVXT-E 6. ( 7.4 + 8.9 ). ( 6.2 + 7. ).86 5.6 5. - 22 m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m Ventilation specifications LGH-RVXT-E, 47, 7 75 4 9 LGH-RVXT-E 2.8 (. +.5 ).4 ( 8.4 +. ).76 4.86 5.59-26 m /h PUHZ-ZRP Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: 75m, Maximum height: m LGH-RVXT-E 9.5 (. + 9.2 ) 5.9 ( 8.5 + 7.4 ). 6. 5.54-26 m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m 2, 5 45 LGH-RVXT-E,, 47 2 82 6 9 9 LGH-2RVXT-E 26. ( 2. + 4. ) 22. ( 9.8 + 2.5 ).87 4.75 4.59 7 - m /h PUHZ-ZRP Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: 75m, Maximum height: m LGH-2RVXT-E 2.6 ( 2. + 9.5 ) 7.6 ( 9.8 + 7.8 ).95 5.97 5. - 26 m /h PUHZ-ZRP7 Diameter Liquid / Gas: 9.52 / 5.88 Maximum length: m, Maximum height: m 2, 4 4 LGH-2RVXT-E,875,2 52 47 79 5 6 74 9 2

Characteristic Curves LGH-RVX-E Without GUG-SL-E 2 With GUG-SL-E 4 6 (m /h) 2 4 6 2 4 6 6 LGH-65RVX-E Without GUG-SL-E 2 With GUG-SL-E 4 6 2 6 2 4 6 22 26 4 6 (m /h) LGH-RVX-E Without GUG-2SL-E 2 With GUG-2SL-E 4 6 2 6 (m /h) LGH-RVX-E LGH-RVX-E LGH-RVX-E 2 Without GUG-2SL-E With GUG-2SL-E 6 (m /h) 2 Without GUG-SL-E With GUG-SL-E Without GUG-SL-E With GUG-SL-E 6 2 2 2 (m /h) (m /h) 6 2 4 4 6 4 6 *Note The graphs below show the supply air only. LGH-RVXT-E LGH-RVXT-E 4 4 2 Without GUG-SL-E With GUG-SL-E Without GUG-SL-E With GUG-SL-E 6 4 4 2 2 2 (m /h) (m /h) 6 4 6 4 6 LGH-2RVXT-E RA temperature control Without GUG-SL-E With GUG-SL-E SA temperature control Without GUG-SL-E With GUG-SL-E 4 4 2 6 4 4 2 4 4 (m /h) (m /h) 4 6 4 6 6 Attention. The running current and input power are based on 2V/Hz. 2. The cooling and heating capacities are based on the air conditions listed below and the rated airflow of fan speed 4. Indoor: 27 CDB/9 CWB Outdoor: 5 CDB/ CWB Indoor: 2 CDB/5 CWB Outdoor: 7 CDB/6 CWB. The first figure in ( ) of the capacity specification is the heat recovery energy of the Lossnay unit. The second figure is the capacity specification for the Dx-coil connected to the outdoor unit. 4. Performance index is the calculated value at the temperature conditions above and is reference purpose only. Performance index = Total capacity total power consumption of outdoor unit and Lossnay unit 5. The external static pressure listed in the tables includes the static pressure loss of the Dx-coil unit when using a cm straight duct between the Lossnay and Dx-coil units. When the duct work between the Lossnay and Dx-coil units is longer and/or bent, the pressure loss of the duct work should be included in the pressure loss calculation. 6. The designed airflow of the system (Lossnay, Dx-coil and duct work) at fan speed and 4 should be kept within Airflow range at and listed in the tables. This range is shown as the solid line in graphs of the characteristics curve. If the Lossnay airflow is out of this range, the compressor of the outdoor unit may stop for self-protection purposes. 7. By installing the Dx-coil unit with a Lossnay unit, the air blow noise level is quieter at fan speed 4. Please refer to the Direct Expansion coil unit for Lossnay catalogue. 8. Refrigerant leakage contributes to climate change. Refrigerant with lower global warming potential (GWP) would contribute less to global warming than a refrigerant with higher GWP, if leaked to the atmosphere. This appliance contains a refrigerant fluid with a GWP equal to 975. This means that if kg of this refrigerant fluid would be leaked to the atmosphere, the impact on global warming would be 975 s higher than kg of CO2, over a period of years. Never try to interfere with the refrigerant circuit yourself or disassemble the product yourself and always ask a professional. 226

Residential Use Lossnay Mitsubishi Electric offers you decentralized ventilation and centralized ventilation solutions for optimising your indoor air quality by Lossnay. Decentralized Ventilation Solution Install the wall mounted Lossnay in each room. The heat recovery system provides fresh air at a comfortable air temperature. Total heat exchangers effectively reduce heat loss. 2F VL-(E)S2-E bed room bed room bed room down bath room 2F : VL-(E)S 2 -E VL-SR 2 -E F porch up living room toilet dining room kitchen F : VL-(E)U 5 -E VL-(E)U5-E Centralized Ventilation Solution One Lossnay unit provides -hour ventilation for the entire house, from living room and bedrooms to the bathroom. The heat recovery system provides fresh air at a comfortable air temperature. Sensible heat exchanger effectively reduces excess humidity in the winter. 2F OA EA bed room bed room RA SA bed room down bath room F porch dining room up living room toilet kitchen : VL-22CZGV-E 227

Decentralized ventilation: VL-(E)S2-E, VL-SR2-E and VL-(E)U5-E Product Merit Air supplied and Exhausted Simultaneously Supply and exhaust air simutaneously while transferring the heat. SA RA OA EA Energy Efficient Total heat exchanger minimizes heat loss. Achieve over %* temperature efficiency. *VL-D(E)U5-E at low fan speed in2v Hz *VL-(E)S2-E at low fan speed in 2V Hz The low noise level is good for bedrooms and children s rooms. RA Sound Insulation A sound insulation effect reduces noise generated outside. Normal conversation Moderate Phone ringing Loud Whisper Faint Quiet On the Train In the library 5dB* db* VL-(E)S2-E VL-(E)U5-E *Condition: Hz, 2V, low fan speed Sound of leaves Sound Insulation Effect Sound Source Side Average sound pressure db Sound Receiving Side Average sound pressure db Difference.4 6.2 4.2 *Tested based on VL-8S2-AE *Measured by average sound pressure level of more than db in Hz according to JIS A46. VL-8S2-AE is Japanese dedicated model with equivalent of VL-(E)S2-E Product Features Stylish Design Match any interior décor to create a comfortable room. VL-(E)S2-E VL-SR2-E VL-(E)U5-E Easy Maintenance The only maintenance required is cleaning the outside-air filter and exhaust-air filter. Filters are easily accessible, making quick and thorough cleaning possible. Outside air filter Lossnay Core (Heat exchanger) Core handle Exhaust air filter Exhaust air filter Lossnay Core (Heat exchanger) VL-(E)S2-E Outside air filter VL-(E)U5-E Flexible Installation for Only VL-(E)S2-E and VL-SR2-E Not only horizontal installation but also vertical installation are available. It can fit various types of rooms with flexible installation. Horizontal Installation Vertical Installation Example 2

Centralized ventilation: VL-22CZGV-E Product Merit Newly Developed Heat Exchanger During ventilation, Lossnay recovers warmth in the winter and keeps air cool in the summer. Reducing heating and cooling loads with a maximum exchange efficiency of 86%*. Normal Square Heat Exchanger Simple structure contributes to minimize pressure loss and reduce power consumption. New Diamond Heat Exchanger Due to the diamond design, air passages are longer and help realize higher exchange efficiency. Wider Length Energy Efficient The highest energy-saving performance in its class. (8.5W* minimum input power) Saves heating and cooling costs by minimizing energy loss that occurs during ventilation. Quiet At an ultra quiet 4dB*, it is the quietest product in its class. Blocks outside noise for a more comfortable environment. * Product Features Fan Speed Precise Adjustment Function Each main fan speed value can be further adjusted slightly. Use the PZ-6DR-E remote controller to adjust the speed. ) Considering the total hours of Lossnay opertaion (filter clogging), the fan power can be adjusted automatically after a given period of. 2) After the unit is installed, when if the air volume is slightly lower or higher than the desired air flow, it is possible to make a fine adjustments. ( 4 is available only down and 2 down) Static pressure P-Q curve image +2 + Original - -2 2 4 Multi Ventilation (Power Supply and Exhausted) Mode This mode allows the air supply/ exhaust balance to be varied dynamically. The supply/ exhaust balance can be selected to suit the usage environment. Normal Mode Power Supply Mode Power Exhaust Mode Relax Adjust the indoor pressure balance in case a separate exhaust is installed Increase indoor pressure to prevent unfiltered drafts from coming in Keep steam inside of the shower room Prevent odors from spreading Weekly Timer Operation patterns for each day of the week. ON/OFF and airflow can be set using the weekly r function (up to eight zones per day). This function contributes to enhanced energy-saving operation. Monday to Friday : 5: 8: 7: 9: 2: 2:59 4 Saturday sleeping breakfast go to working place dinner shower 2: sleeping : 8: : : : 22: 2:59 2 4 Sunday sleeping breakfast relax lunch shopping shower sleeping : 8: : : : 7: 9: 2: 2:59 2 4 229 sleeping breakfast relax lunch go out in the family dinner shower sleeping *Example for reference only.

Residential Lossnay Specifications : VL-S2-E (Pull-Switch ), VL-ES2-E (Wall-Switch ) *Figures in the chart is measured according to Japan Industrial Standard (JIS B 86) on shutter knob open position. Dimensions VL-(E)S2-E Electrical power supply 22V/Hz 2V/Hz V/Hz 22V/6Hz High Low High Low High Low High Low (m /h) 5 5 52.5 6 54 7 54 7 Power consumption (W) 9 4 2 4.5 2 5 2 5.5 (%) 86 85 68 68 Noise level (db) 6.5 4 7 5 7.5 5.5 7.5 5.5 Weight (kg) 6.2 Specific energy consumption class C Mounting plate temporary fixing hole position Edge of main unit Mounting holes 5 6 Air intake/exhaust hole 2 wall hole (Left : exhaust, Right : intake) (522) min from nearest obstruction Air intake/exhaust hole Indoor-air exhaust (Left : exhaust, Right : intake) Fresh-air supply 2.5 4 4.5 Pitch 2x8=6 9.5 6min from nearest obstruction 5 26 Indoor-air exhaust Terminal block 26.5 2 Power and connection cable pullout area (6).5 (82) 9min from nearest obstruction 2min from nearest obstruction 4 2 97.6 Outer dia 96 Outer dia Shutter knob position (4) Open position Exhaust only position Close position Outside-air intake : VL-S2-E : VL-ES2-E Outside-air intake 6 Exhaust to outside 4 Indoor-air 58.5 Indoor-air exhaust exhaust Wall thickness 522 68 to 6 9 About 4 4 x 8.5 mounting holes B (Knocking hole) 5 4 x 5 mounting holes A Unit (mm) : VL-SR2-E (Remote Controller ) *Figures in the chart is measured according to Japan Industrial Standard (JIS B 86) on shutter knob open position. Dimensions VL-SR2-E Electrical power supply 22V/Hz 2V/Hz V/Hz 22V/6Hz High Low High Low High Low High Low (m /h) 5 5 52.5 6 54 7 54 7 Power consumption (W) 9 4.5 2 5 2 5.5 2 6 (%) 86 85 68 68 Noise level (db) 6.5 4 7 5 7.5 5.5 7.5 5.5 Weight (kg) 6.2 Specific energy consumption class C Mounting plate temporary fixing hole position 26 26.5 2 Power and connection cable pullout area Edge of main unit Mounting holes 5 6 Air intake/exhaust hole 2 wall hole (Left : exhaust, Right : intake) (522) min from nearest obstruction Air intake/exhaust hole Indoor-air exhaust (Left : exhaust, Right : intake) Fresh-air supply 2.5 4 4.5 Pitch 2x8=6 9.5 (6).5 (82) 6min from nearest obstruction 5 Indoor-air exhaust 9min from nearest obstruction 2min from nearest obstruction 4 2 97.6 Outer dia 96 Outer dia Shutter knob position Remote controller (4) 54 Open position Exhaust only position Close position Outside-air intake Outside-air intake 6 88 Exhaust to outside 4 Indoor-air 58.5 Indoor-air exhaust exhaust Wall thickness 522 68 to 6 9 4 x 8.5 mounting holes B (Knocking hole) 5 4 x 5 mounting holes A Unit (mm) 2

: VL-U5-E (Pull-Switch ), VL-EU5-E (Wall-Switch ) *Figures in the chart is measured according to Japan Industrial Standard (JIS B 86) on shutter knob open position. VL-(E)U5-E Electrical power supply 22V/Hz 2V/Hz V/Hz 22V/6Hz High Low High Low High Low High Low (m /h) Power consumption (W) (%) Noise level (db) 7 6.5 55 5 7 7 6 5 6 4 72 6 7 79 27 4 7 57 7 Weight (kg) 7.5 Specific energy consumption class B Dimensions Terminal block Require to be secured Edge of main unit 42 Mounting plate Mounting holes 6 6 97 87 95.5 4 (Adjustable) 5 Front panel (Close position) 9 95 75 (Adjust able) (min) 75 (Adjust able) Air intake hole Power cord hole (max) 85 to wall hole Air exhaust hole 267.5 292 85 to wall hole 5 22 554 62 6min from nearest obstruction 6min Indoor-air exhaust Front panel (Open position) 2 Pitch 2x=.5 2.5 265 min from nearest obstruction 2min Outer dia 75 2 : VL-U5-E : VL-EU5-E Outer dia 79 2 Front panel louver (Vertical position) 5 Fresh-air supply 2 4 75 Shutter knob 62 (Open position) Shutter knob (Closed position) Front panel louver (Horizontal position) 22 7 54 Wall thickness 226 to 5 6 Unit (mm) : VL-22CZGV-E VL-22CZGV-E Electrical power supply 22-V/Hz 22V/6Hz Ventilation mode Heat recovery mode 4 2 Running current.6.29. Input power (W) 5.5 (m /h) 2 65 2 64 46 External static pressure (Pa) 64 (%) 82 85 Noise level (db) 9 Weight (kg) Specific energy consumption class A *Figures in the chart is measured according to Japan Industrial Standard (JIS B 86). Characteristic Curves are measured by chamber method.. 8.5 65 86 4 Characteristic Curve mm dia straight pipe length 4 5m 4 2 m 5m 6 4(m/h) 2 4 6 Dimensions 4 9 27 229 Power-supply cable opening Ceiling suspension fixture Duct connecting flange (SA) SA (Supply air) EA (Exhaust air) Duct connecting flange (EA) 885 46 8 74 9 Drain outlet 72 775(Ceiling suspension fixture) 85 5 Exhaust-air filter case Drain pan 8 8(Ceiling suspension fixture) 2 RA (Return air) OA (Outdoor air) 2 62 Supply-air filter case 6 8 86 99 295 Duct connecting flange (RA) Auxiliary fixture Duct connecting flange (OA) Unit (mm) 2

Accessories Optional Parts for VL-(E)S2-E and VL-SR2-E Filter, Extension Pipe and Stainless Hood Type High Efficiency Filter Replacement Filter Extension Pipe Joint Stainless Hood Design P-HF2-E P-F2-E P-P-E P-PJ-E P-VSQ5-E Feature Upgrated high-performance filter. Standard grade replacement filter. Total length when connected to the joint is mm. Joint for extension pipe Stylish stainless hood Optional Parts for VL-(E)U5-E Filter and Extension Pipe Type High Efficiency Filter Replacement Filter Extension Pipe Joint Design P-HF5-E P-F5-E P-P-E P-PJ-E Feature Upgrated high-performance filter. Standard grade replacement filter. Total length when connected to the joint is mm. Joint for extension pipe Screw-in method Optional Parts for VL-22CZGV-E Bypass damper : P-DUE-E 9 6 7 9 57 2-.5 Mounting bracket mounting hole 2-.5 Mounting bracket mounting hole 4 52 4 4-.5 Duct connecting flange mounting hole 2 Unit (mm) Filter Type High Efficiency Supply Air Filter Medium Efficiency Exhaust Air Filter Standard Replacement Filter Design P-22SHF-E P-22EMF-E P-22F-E Classification (EN779:22) M6 G4 G 22