Micro/Ultra Filtration System StamoClean CAT 430

Similar documents
Micro/Ultra Filtration System StamoClean CAT 430

Rinse connection adapter CPR 40

Ultrasonic Level Measurement nivopuls FDU 10 S

Turbimax CUE21 / CUE22

Condensate Monitor CGKW. Operator s Manual 42/23-36 EN Rev. 2

Dissolved Oxygen Measurement liquisys S COM 223 / 253

Turbimax CUE21 / CUE22

Weller. Zero-Smog Filter Systems. Tip Extraction. Volume Extraction

OPTISENS TUR 2000 Technical Datasheet

Frost Protection Thermostat

HYGROPHIL H process hygrometer

System Components and Accessories for Sample Gas Conditioning. Data Sheet 10/ EN June 2004

Frost Units for air temperature monitoring

Vacuum Pump V-100 Technical data sheet

Data Sheet. >>AMTAX inter 2

Chlorine / Chlorine Dioxide Measurement liquisys S CCM 223 / 253

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Shop. Item Information. Interface I-100 For V-100/V-7x0. Send item information. Show item in shop. Add item to cart.

Liquiphant T FTL20H. Technical Information

AC THOR. Assembly Instructions

MANUAL FOR MJK LIQUID SAMPLER 780

Pressure Transmitter cerabar S PMC 731/631 cerabar S PMP 731/635 with ma output signal

condensate pumps For air conditioning and refrigeration technology eckerle.com

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

TMS filter system with automatic backwashing

CH cleaning head Sensor cleaning accessory operated by compressed air

PROFIBUS-PA Display RID 261 PROFIBUS-PA

Differential Pressure Transmitter deltabar S PMD 230/235 deltabar S FMD 230/630/633 with ma output signal

Operating Instructions. Condumax CLS15/16/21. Analog sensors For conductive measurement of conductivity in liquids BA01148C/07/EN/01.

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

CIRCO 6 Solar Circulation Unit

Technical Information OUSBT66

ph Measuring System Start-up and maintenance manual e Contents

Refrigeration Dryers TG TI Series

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

Mini Spray Dryer B-290 Technical data sheet

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

Moisture supervision for power transformers

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Level Electrode NRG NRG Original Installation Instructions English

Operation Manual. Time controlled condensate drain unit UFZ. 000_H_uf_UFZ_GB_R00_D011002

INSTRUCTIONS CertoClav EL

Vibracon LVL-A* Level limit switch for liquids, compact design

Gas cooler series RC 1.1

FluidAqua Mobil FAM 5

Technical Information OUSTF10

Hand Held Welding Guns

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, SQUATTING TOILET. To main vacuum line, connection Ø50.

Soliphant M with electronic insert FEM52

Automatic Condensate Drains ECO DRAIN Series

SET-2000 Oil/Sludge 12 VDC

Fume Extraction Solutions. We care for your working environment.

Technical Information OUSAF21

INSTRUCTION MANUAL & 8200 Monitor. Manual Issue 06

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

LS Condensate Removal Pump INSTRUCTION MANUAL REVISION A

UFM-T100H US ES CA Power Alarm Test TM

WATER, OIL, CONTAMINANTS: SEPARATION AND EVACUATION

Ready-to-Use Heat Tracing Solutions for Laboratory Applications. innovations in heat tracing

Technical Guide. Installation, Operation and Care. EP E series 7 step electric boilers 26 and 42 kw

An ISO 9001 : 2008 Certified Company

Operating Instructions

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Extraction systems for the electronic industry. Soldering workstations Soldering smoke extraction systems

Operating Instructions

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operating instructions

Adsorption dryers PDAD

1592P01. for liquids in piping DN

BINDER Scientific Product Catalog

Gas burner automatic safety control MMI / 811.1

Meets the Highest Standards in Sanitary Cleaning

Installation, operating and servicing instructions

A measured step forward

Level Electrode NRG Original Installation Instructions English

Flow Switches. Series VHS, VKS, VH

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Pos. Description Reference

Analog Transmitter AT1000 AT1

Safety vacuum drying oven for flammable solvents

Shop. Item Information. Rotavapor R-300 B-305, SJ24/40, C, P+G, WB, 110V. Send item information. Show item in shop. Add item to cart.

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Air operated diaphragm pumps. Catalogue 2011 rev 1

Operating Instructions!

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

Technical Information OUSTF10

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

LABORATORY ULTRA ZERO AIR GENERATOR. ZAC-ULT Series USER MANUAL

Gas cooler series TC-Standard+

Drester High performance Gun Cleaner for all paint systems

C Note! LGI16... Burner Controls. Building Technologies

Filters & Centrifugal Separators

Manufacturer declaration. 3-A, Installation and Cleaning Instructions. VEGAPULS 63 Hygienic process fittings. Document ID: 46197

Transcription:

Technical Information TI 338C/07/en/10.03 No. 51508729 Micro/Ultra Filtration System StamoClean CAT 430 Long-term Stable Membrane Filter for Immersion Operation in Activated Sludge Basins or Wastewater Application The CAT 430 is a patented ultra filtration system for process instruments in sewage treatment plants. CAT 430 can be used for all Endress+Hauser analyzers. CAT 430 transports clear samples from the activated sludge basin to the measuring devices. Expensive pump installation in the activated sludge basin is no longer necessary. Applications are: In activated sludge basins Outlets of sewage treatment plants Your benefits Ultra filtration without the disadvantages of conventional ultra filtration No additional pump necessary Minimum energy consumption Minimum maintenance required Filtrate quantity can be optimised by number of filter elements Minimum dead volume ensuring a representative sample Large carrying distance up to 100 m Cleaning without chemicals Quality made by Endress+Hauser ISO 9001

Function and system design Measuring principle The centrepiece of the system is a flat membrane filter element which is suspended directly in the wastewater basin or channel. A hose pump, located in a pump box on the rim of the basin, is connected to the filter element by means of a thin PE tube. The pump creates a vacuum between the membrane and the carrier plate of the filter element. This vacuum causes the filtrate to pass through the filter membrane. Suspended materials, particles, algae and bacteria are collected on the surface of the membrane. However, thanks to an alternating pumping action with time delays, the layer on the surface of the membrane is never allowed to build up which means that intervals of more than one month are achieved between cleaning cycles. The minimum specified intervals must be maintained. Parallel connection of two or four filter elements means that the sampling quantity can be increased to up to 1 l/h approx. The hose pump pressure alone transports the sample from the pump box to the analyzer over a distance of 20 m. For distances up to 100 m, a sample transportation unit is used whereby a certain sampling quantity is transported to the analyzer by means of compressed air. A collecting vessel is used to collect the sample on the analyzer side. This vessel is mounted as close as possible to the analyzer and also serves to filter out air bubbles. The individual measuring devices draw in samples from this vessel while surplus samples can drain away by means of a tube attached to the centre of the collecting vessel. Measuring system Version with hose pump A complete measuring system comprises: a CAT 430 filter system a collecting vessel a CA 71xx analyzer Optionally, a sensor with flow assembly can also be integrated into the measuring system. If an assembly with low dead volume and flow resistance is used (see "Accessories"), the sensor can be installed in line with the analyzer s inlet. 1 2 3 9 A Endress Hauser B 4 5 6 7 8 C07-CAT430xx-14-14-00-xx-001.eps Measuring system 1 Pump box 5 Collecting vessel 2 Timer 6 Analyzer 3 Control unit 7 Activated sludge basin 4 Y-piece 8 Membrane filter A Filtrate line to the analyzer (PTFE1.5/3 mm, < 20 m 1 ) 9 Hose pump B Filtrate line from the filter elements (PE, 4.5 m (14.76 ft), with heating, max. length 17 m (55.78 ft)) 1) 0.06/0.12 inch, <65.62 ft 2 Endress+Hauser

Version with diaphragm pump A complete measuring system comprises: a CAT 430 filter system a collecting vessel a CA 71xx analyzer Optionally, a sensor with flow assembly can also be integrated into the measuring system. If an assembly with low dead volume and flow resistance is used (see "Accessories"), the sensor can be installed in line with the analyzer s inlet. 1 2 3 9 A Endress Hauser B 4 5 6 7 8 Measuring system 1 Pump box 5 Collecting vessel 2 Timer 6 Analyzer 3 Control unit 7 Activated sludge basin 4 Diaphragm pump 8 Membrane filter A Filtrate line to the analyzer 1 9 Y-piece B Filtrate line from the filter elements (PE, 4.5 m (14.76 ft), with hose heating) C07-CAT430xx-14-14-00-xx-001.EPS 1) Two sample hoses are integrated in a protecting hose: 1 x 1.5/3 mm (0.06/0.12 inch) PTFE hose (standard) and 1 x 2/4 mm (0.08/0.16 inch) PE hose (spare). Endress+Hauser 3

Power supply Control box connection Analyzer compartment 230 V AC, 50/60 Hz, 130 VA 115 V AC, 60 Hz For electric band heater > 20 m (65.62 ft): 15 VA per meter electric band heater, socket 230 V AC, 50/60 Hz, earth leakage breaker protected Control unit terminal assignment 3 4 7 8 9 13 14 15 19 20 23 24 1 2 3 1 2 5 6 10 11 12 16 17 18 21 22 25 26 N L PE PROG. RESET b d 4 5 6 c e L N a f PE C07-CAT430xx-04-14-00-xx-004.EPS Control unit terminal block a Control b Thermal switch 24 V c d Filtrate hose heater 24 V Pump e f Electric band heater Housing heater T 1 Assignment T 1 Assignment T 1 Assignment 1 24 V to hose heater 10 Phase L housing heater 19 not connected 2 24 V from thermal switch 11 Phase L to control 6 20 Phase L mains supply 3 not connected 12 Phase L to control 2 21 not connected 4 not connected 13 Zero conductor (as required) 22 not connected 5 24 V to thermal switch 14 Electric band heater zero cond. 23 PE electric band heater 6 24 V to hose heater 15 Mains supply zero conductor 24 PE mains supply 7 Phase L from relay 16 Housing heater zero conductor 25 PE housing heater 8 Phase L electric band heater 17 Pump zero conductor 26 not connected 9 Phase L pump contin. operation 18 Control zero conductor 1) T = terminal You have to connect terminals 15, 20 and 24. You have also to connect terminals 8, 14 and 23 if using an electric band heater for the sample carrying tube. All other connections have been made at the factory. 4 Endress+Hauser

1 2 3 PROG. RESET 4 5 6 StamoClean Cat 430 Performance characteristics Filtrate volume with hose pump Filtrate volume with diaphragm pump Sample transportation distance with hose pump Sample transportation with diaphragm pump Separation performance Life cycle approx. 250 ml/h per filter element approx. 450 ml/h per filter element max. 20 m (65.62 ft) max. 100 m (328.10 ft) Precipitation of particles, colloids and high molecular substances (0.1 µm) approx. 1 to 2 years Cleaning interval Filter element: PTFE hose: PE hose: 2 to 6 months, depending on contamination level 1 to 2 months 3 weeks Chemical resistance ph 1... 13 Installation Installation instructions control box Version with hose pump 1 2 a 3 4 5 11 10 9 8 7 6 C07-CAT430xx-06-14-00-xx-005.EPS Control box 1 Manometer 7 Pg hose gland and filtrate line to the analyzer 2 Cable duct 8 Pg hose gland for filtrate line from filter 3 Hose pump 9 Pipe socket with micro thermostat 4 Timer 10 Y shaped fitting 5 Connection box 11 Housing heater 6 Pg cable gland for mains connection a Transport securing Endress+Hauser 5

Version with diaphragm pump Control box C07-CAT430xx-06-14-00-xx-004.EPS 1 Manometer 8 Pg hose gland for filtrate line from filter 2 Cable duct 9 Pipe socket with micro thermostat 3 Vent screw 10 Y fitting 4 Timer 11 Housing heater 5 Connection box (see Electrical connection ) 12 Diaphragm pump 6 Pg cable gland for mains connection 13 Vent 7 Socket and filtrate line to the analyzer Installation instructions filter elements 7 6 1 Detail A 1 2 3 4 5 6 7 8 Filtrate line to pump T-piece Filtrate hose PVC thread cap Retaining slide Filter element Mounting guide pipe Hexagon nut 5 2 8 3 Detail A 4 Slide with filter element and filtrate line C07-CAT430xx-06-14-00-xx-003.EPS 6 Endress+Hauser

1 1 2 2 3 6 3 6 7 4 8 4 7 9 8 5 10 5 C07-CAT430xx-06-14-06-xx-001.EPS Filter element holder for open channel 1 Wall mounting, flat steel 30 x 8 mm 2 Square pipe 50 x 30 x 3 mm 3 Thread adapter nut G1¼, hose nozzle D25 4 Taper nipple R1¼ 5 Thread adapter nut G1¼, cable gland Pg 7 6 Hexagon nut M10 11 Filter element holder for basin 7 Cap G1 8 Flat seal 48 x 33 x 2 mm 9 Flat steel 60 x 8 mm 10 Flat steel 30 x 8 mm 11 Slide for filter element, square pipe 50 x 30 x 3 mm 11 C07-CAT430xx-06-14-06-xx-002.EPS Environment Ambient temperature range 25 to 50 C ( 13 to 122 F) Air humidity 0 to 95 %, no splash water Ingress protection IP 54 Endress+Hauser 7

Process Sample temperature 5 to 50 C (41 to 122 F) Mechanical construction Holders and filter elements dimensions 200 100 200 100 108 108 1500 / 1800 75 525 1500 / 1800 400 500 120 100 150 500 120 400 30 30 12 12 160 160 Holder for open channel, side view C07-CAT430xx-06-14-00-xx-006.EPS Holder for basin, side view C07-CAT430xx-06-14-00-xx-007.EPS Ø12 450 150 180 350 C07-CAT430xx-06-14-00-xx-008.EPS C07-CAT430xx-06-14-00-xx-001.EPS Detail wall mounting, front view Filter element 8 Endress+Hauser

50 20 24 3 3 Ø40 G1 G1 Adapter for mounting a 2nd filter plate C07-CAT430xx-06-14-00-xx-009.EPS Dimensions control box 400 327 30 200 400 420 4 x Ø 8.5 Control box dimensions, left front view, right side view C07-CAT430xx-06-14-00-xx-003.EPS Weight Control box with hose pump Control box with diaphragm pump Filter unit, 1 filter element Filter unit, 2 filter elements Filter element Filter element holders 12 kg (26.5 lb) 15 kg (33.1 lb) 2 kg (4.4 lb) 4 kg (8.8 lb) 1 kg (2.2 lb) 18 kg (39.7 lb) Materials Housing heater Resistance heater, 230 V, ~ 50 W, splash-proof, on Al-heat exchanger plate Filter element PVC carrier plate, PES membrane Filter element holders Stainless steel, 1.4301 (AISI 304) Mounting guide pipe Stainless steel, 1.4301 (AISI 304) Endress+Hauser 9

Human interface Display and operating elements 1 2 3 PROG. RESET 4 5 6 Operating elements C07-CAT430xx-19-14-00-xx-002.eps Timer: Trumeter 7955 X C07-CAT430xx-19-14-00-xx-011.EPS 1 Heating / Power on 2 Control 3 Evacuate (pump continous operation) Ordering information Product structure Sample volume A 250 ml/h; 1-2 StamoLys CA 7X, incl. 5 m hose to filter and pump box B 500 ml/h; 3-4 StamoLys CA 7X, incl. 5 m hose to filter and pump box Y Special version acc. to customers specification Length of the sample tube (from pump box to analyzer) 1 up to 20 m (65.62 ft), with hose pump 2 up to 100 m (328.1 ft) with hose pump, 100 m (328.1 ft) hose, compressed air is needed 3 up to 100 m (328.1 ft) with hose pump+internal compressor and 100 m (328.1 ft) hose 4 up to 100 m (328.1 ft) with diaphragm pump and 100 m (328.1 ft) hose 5 up to 100 m (328.1 ft) with diaphragm pump and 50 m (164.05 ft) hose 9 Special version acc. to customers specification Fittings (from pump box to analyzer) A Without sample hose heater D With 8 m (26.24 ft) sample hose heater F With 18 m (59.06 ft) sample hose heater Y Special version acc. to customers specification Power supply 0 230 V AC 1 115 V AC Sampling between filter and pump box A with heating B without heating Mounting pump box 2 Wall mounting 3 Basin rim mounting and protection cover 4 Special housing for additional CSM resp. CNM 750 9 Special version acc. to customers specification! Note! CAT 430 - Please, order basin rim holders separately. See "Accessories". Assembly A No assembly Y Special version acc. to customers specification complete order code 10 Endress+Hauser

Scope of delivery Version with hose pump The scope of delivery comprises: 1 Pump box, complete with filtrate line connected, length 4.5 m (14.75 ft), hose heating 24 V 2 Hose clamps 44-49 mm (1.73-1.93 inch), set screw M8 4 Plastic brackets 1 Cushion with screw 1 Collecting vessel with PE hose 10/8 mm (0.31/0.39 inch), length 2.5 m (8.2 ft) 1 PE hose roll 4/2 mm (0.16/0.08 inch), length 2.5 m (8.2 ft) 1 PVC hose roll 4/2 mm (0.16/0.08 inch), length 2.0 m (6.65 ft) 1 or 2 Filter plate(s) (depending on ordered version) 1 or no assembly (depending on ordered version) 1 Filtrate line with PE filtrate hose 4/2 mm(0.16/0.08 inch), min. length 20 m (65.62 inch) depending on ordered version 1 Acceptance certificate 1 Mini screw driver 1 Dummy plug 2 Silicon hose nozzles 2 Tierap 1 Operating Instructions BA 317C/07/en Version with diaphragm pump The scope of delivery comprises: 1 Pump box, complete with filtrate line connected, length 4.5 m (14.75 ft), hose heating 24 V 2 Hose clamps 44-49 mm (1.73-1.93 inch), set screw M8 4 Plastic brackets 1 Cushion with screw 1 Collecting vessel with PE hose 10/8 mm (0.31/0.39 inch), length 2.5 m (8.2 ft) 1 PE hose roll 4/2 mm (0.16/0.08 inch), length 2.5 m (8.2 ft) 1 PVC hose roll 4/2 mm (0.16/0.08 inch), length 2.0 m (6.65 ft) 1 PTFE hose roll 3/1.5 mm (0.12/0.06 inch), length 2.5 m (8.2 ft) 1 or 2 Filter plate(s) (depending on ordered version) 1 or no assembly (depending on ordered version) 1 Filtrate line with PE filtrate hose 4/2 mm(0.16/0.08 inch), min. length 20 m (65.62 inch) depending on ordered version 1 Acceptance certificate 1 Allen key 4 mm (0.16 inch) 1 Allen key 4 mm (0.16 inch) with handle, length 200 mm (7.87 inch) 1 Fitting 3 mm (0.12 inch) 1 Dummy plug 1 Operating Instructions BA 380C/07/en Certificates and approvals 4 approval Declaration of conformity The product meets the legal requirements of the harmonised European standards. Endress+Hauser confirms compliance with the standards by affixing the 4 symbol. Accessories Adapter for mounting a 2nd filter plate, order no. 51511355 (2 adapters needed per filter plate) Filter element holder with vertical retaining slide, 1.50 m, for basin order no. 51511353 Filter element holder with vertical retaining slide, 1.80 m, for basin order no. 51511354 Filter element holder with horizontal retaining slide, 1.50 m, for open channel order no. 51511373 Filter element holder with horizontal retaining slide, 1.80 m, for open channel order no. 51511374 Flow assembly with reduced dead volume order no. 51509332 Endress+Hauser 11

Documentation StamoClean CAT 430 with hose pump, Operating Instructions, BA338C/07/en, order no. 51508731 StamoClean CAT 430 with diaphragm pump, Operating Instructions, BA380C/07/en, order no. 51514215 StamoLys CA 71 AM, Analyzer for Ammonium, Technical Information, TI353C/07/en, order no. 51512286 StamoLys CA 71 NO, Analyzer for Nitrite, Technical Information, TI355C/07/en, order no. 51512290 StamoLys CA 71 PH, Analyzer for Phosphate, Technical Information, TI356C/07/en, order no. 51512292 Endress+Hauser GmbH+Co. KG Instruments International P.O. Box 2222 D-79574 Weil am Rhein Germany Tel. (07621) 975-02 Tx 773926 Fax (07621) 975 345 e-mail: info@ii.endress.com Internet: http://www.endress.com 11.01 TI 338C/07/en/10.03 No. 51508729 FM+SGML 6.0 / ProMoDo / Printed in Germany / DT