Product Information. Optical fibre water sensor. - Early warning system for ensuring maximum availability of optical transmission routes

Similar documents
Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

Duct Cable GYTS-144B1.3

Optical Fibre Cable Technical Specification. Duct Cable GYTA-72B1.3

FLX380-30x FlexTester OTDR

Dome Fiber Optic Closure SC-221

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

ECP OPTICAL FIBRE SPLICING, TESTING AND COMMISSIONING REQUIREMENTS

Fibre Characterisation and FTTx New challenges

HELKAMA. Optical Fibre Cables

Special Provision No. 683S28 December 2017

Yokogawa Meters & Instruments Releases AQ1200E, AQ1205A, AQ1205E, and AQ1205F OTDR Multi Field Testers

DWDM OTDR with Tunable Laser MTP-200-D100. Hand-held High Performance OTDR. Series

Remote fiber testing to improve SLA s

FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS - Item No. FIBRE OPTIC COMMUNICATION CABLES, IN DUCTS (TEMPORARY) - Item No.

Fibre Optic Basics FIA Summer Seminar 2014

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

FACULTY OF ENGINEERING LAB SHEET OPTICAL COMMUNICATION SYSTEMS EOP4066 TRIMESTER 1 (2013/2014)

OTDR II. Tier-2 Optical Time Domain Reflectometer for Multimode and Single-mode Fiber Cabling

Metal, ceramic, plastic package products

ETSI TS V1.2.1 ( )

Broadband System - H

LAB REPORT SUBMISSION COVER PAGE ETN4106 OPTOELECTRONICS AND OPTICAL COMMUNICATIONS

OPTICAL TIME-DOMAIN REFLECTOMETER

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FTB-730 PON FTTx/MDU OTDR OPTIMIZED FOR ACCESS FIBER DEPLOYMENTS AND TROUBLESHOOTING

Noyes OFL 250B Specs Provided by

M700-Series Multifunction OTDR

Fiber Optic and CAT 5, 6, 7 and 8 Installer Premise Cabling

FTB-7400E Metro/CWDM OTDR METRO/CORE AND CWDM NETWORK FIBER CHARACTERIZATION

Hands-On Fiber Optic ISP / OSP Combo-Tech Splicing, Termination & Testing

Kingfisher KI-3800 Light Source. Inexpensive handheld source for testing and commissioning optical fibre networks. Compact and rugged,

OPTICAL TIME DOMAIN REFELECTOMETER (OTDR): PRINCIPLES

AV6416 OTDR. Product Overview: Main Features:

Datasheet Palm OTDR. Product Summaries

Draft ES V1.1.1 ( )

Hands-On Fiber Optics ISP/OSP - Advanced Combo- Tech

4120 Fire Alarm Network Reference

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

FLX380 and OFL280 FlexTester Series

Securing optical network physical layer with Fiber Monitoring and Management Vratislav Blažek Regional Sales Manager

ANALYSIS OF OTDR MEASUREMENT DATA WITH WAVELET TRANSFORM. Hüseyin ACAR *

Data sheet OpDAT universal cable 1x24 OM4 - bend insensitive

iotdr Series Portable OTDR Test Set iotdr Series OTDR Tester is entirely new portable product released by OPWILL.

Ensuring Cabling Performance in the Customer-Owned Outside Plant

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

STANDARD TEST PROCEDURE PRE-TEST QUALITY OF OPTIC FIBRE CABLE ON DRUMS TYPE OF CABLE :

Quality Assurance and Quality Control of Optical Fibres for CERN

INTERIM EUROPEAN I-ETS TELECOMMUNICATION June 1997 STANDARD

palmotdr Series Handheld OTDR

OFS IV Optical Fibre System

Fiber Tes)ng 101 Essen)als Every Network Analyst Needs to Know. David S(llwell BCNET Oscar Rondon BCNET Gwenn Amice - EXFO

OTDR - FHO5000-xxx. Optical Time Domain Reflectometer

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Field Test Procedure for Optical Fibre Link Measurements

MT-RJ Optical Fiber System Field Testing

MEGOHMETER. PCS ITALIANA srl TECHNICAL DATA DESCRIPTION:

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Data sheet OpDAT mini breakout cable 24x1 OM4 - bend insensitive

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

FG-750 Client API SDN-READY INTELLIGENT OTDR

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

M310 Enterprise OTDR. Designed for Enterprise Network Testing, Troubleshooting and Documentation. or (800) , (603)

FLX380-30x FlexTester3 OTDR

Ensuring the Health of Tomorrow s Fiber LANs Part II OTDR Trace Analysis Become an Expert Troubleshooter with Advanced OTDR Trace Analysis

Data sheet OpDAT breakout cable 12x1 OM4 - bend insensitive, class Dca s1 d1 a1

Field Testing and Troubleshooting of PON LAN Networks per IEC Jim Davis Regional Marketing Engineer Fluke Networks

Test Report for Senko Advanced Components, Report No RES3005 February 22, Test Report. Senko Advanced Components

Fibre (TIA) Field Test Specification

Case No IV/M Ericsson / Raychem. REGULATION (EEC)No 4064/89 MERGER PROCEDURE. Article 6(1)(b) NON-OPPOSITION Date: 21/11/1994

General safety precautions English

General safety precautions English

Technical Specification for the Mastic-Sealed Fiber-Optic Closure System (FOSC 300C)

ITU-T L.12. Optical fibre joints SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

LINEAR HEAT SERIES FIBER OPTIC LINEAR HEAT DETECTION SYSTEM

FTS500 Series. Handheld OTDR Test Set.

VTI Services Technical Bulletin (TB) OTDR Measurement of Installed Optical Fibre Cabling Permanent Links and Links

FTB-720 LAN/WAN Access OTDR OPTIMIZED FOR MULTIMODE AND SINGLEMODE ACCESS NETWORK TESTING

Ensuring Cabling Performance in the Customer-Owned Outside Plant. Keith Foord Product Manager Greenlee Communications

Hands-On CAT 5/6 & Fiber Optic Installer

M700-Series OTDRs. or (800) , (603)

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

The Rise of Tier 2 Testing

Certified Fibre Optic Specialist - Testing

AE3100A~M Series 2-and 4-Wavelength Handheld OTDR

Fibre Specification Standards

A. General: Horizontal and backbone cabling shall be verified in accordance with ANSI/TIA/EIA-568-C and the addendum for fiber optic testing.

FTBx-740C-DWC TUNABLE OTDR C-BAND DWDM METRO ETHERNET LINK CHARACTERIZATION

GAMMA OTDR application consists of main window and menu. Using menu user can operate in different modes of application.

Fiber Optics for Todays Industry Applications

palmotdr Series Handheld OTDR

SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND NETWORKS Transmission media and optical systems characteristics Optical fibre cables

WG Buried Fibre Cable Long Perimeter Detection System

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

Extensive range of models covering all telecom testing applications. Flexible design, allowing up to three wavelengths in a single module

OUTDOOR BLINDS + EXTERIOR VENETIAN BLINDS

Tether and Umbilical Cables for Remotely Operated Vehicles

Basic Professional Fiber Optic Installation

Transcription:

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Product Information Optical fibre water sensor - Early warning system for ensuring maximum availability of optical transmission routes PI Page 1

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Optical Fibre Water Sensor 1. Requirements for optical cable networks Competitiveness among telecommunication service providers has created high demands on quality, reliability and availability within the optical transmission field. Providers not only run networks, but also tend more and more to rent out single fibres to customers. Optical cable transmission channels are used day and night to carry huge quantities of data and consequently practically 100% availability is expected of them. Breakdowns cause considerable financial loss, installation and measurement procedures necessary for carrying out repairs involve high costs and should therefore be avoided as far as possible. Reality? According to the statistics of the ITU and the Deutsche Telekom AG, faults in monitored cable networks are distributed between WAN and LAN as follows: LAN WAN 0,93 faults per 100 cable-km 1,22 faults per 100 cable-km Distribution according to fault area 19% fibre fault 28% joint fault 31% sheath fault 22% others PI Page 2

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product 2. Reasons for water leakage into joint-boxes and consequences 2.1 Reasons for water leakage into joint-boxes installation cable joint-box nature Cable sealing Cable immobilisation Blind plug Joint-box sealing Shrinkage of cable end Damaged (holes) cable sheath (double sheath) Construction Test method 2.1 Consequence of water leakage into joint-boxes Plant roots Extreme temperature changes If water penetration goes unnoticed for any length of time the fibres may break, thereby causing network failure due to the product-specific characteristics of both optical fibres and splice protection. Pic. 1: Example: Fibre breakage caused by water leakage into the joint-box (Location: Rheinufer Düsseldorf, cable had been laid 11/2 years previously, 5 fibres broken in 3 splice cases) PI Page 3

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Average stress, kpsi 3. Reasons for fibre breakage 3.1 Characteristic properties of optical fibres Optical fibres have reached a satisfactory state of development for the fulfilment of most standard requirements. If breakage does occur after fibres have been immersed in water for a long time, this is due to stress cracking corrosion, caused by water diffusion in component parts. Si-O-Si +OH - Si-OH + - O-Si This process intensifies the fine surface cracks already present as a result of fibre production proce-dures. This is further aggravated by mechanical wear and tear (e.g. the relative narrowness of the bend Ø in splice cassettes or joint-boxes makes them vulnerable.) Cable durability is thus consider-ably impaired (IDiag. 1) and ends in fibre breakage [1]. Attenuation increase in glass fibres in a damp environment Diag. 2 shows attenuation increase in optical fibres in a damp environ- ment, caused by a diffusion of hydrogen in the fibre core. Low attenuation values between 1200 and 1500 nm in atmospheres with a high concentration of hydrogen can only be permanently reached by using glass fibres with a hermetically sealed metal coating [1]. Stress at beginning 100 kpsi Humidity 50% Temperature 23 Hermetic-sheated fibre (n = 100) plastic-sheated fibre (n = 22) Time Diagr. 1 Diagr. 2 Sources: [1] Ray Chaudhuri, S. and Schulze, P.C.: Hermetic Coating on Optical Fibres, SPIE s 1996. Cambridge Symposium on Optoelectronics and Fiber Optic Applications in Science and Engineering, 21-26.9.1986 Cambridge, Massachusetts, USA PI Page 4

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product / 3. Reasons for fibre breakage 3.2 surrounding conditions Fibre breakage within one year is possible at ph-values 2 3 (f.ex. at brown forest soil, forest soils, streets and motor ways Example 1: ph-value in German forest soils Distribution of the ph-values in 10-30 cm soil depth Average ph-values Brown forest soil ph 2,2 4,9 animal husbandry ph < 4 forest soil ph 2,8 road salt ph < 4 high moor ph 3-4 Source: (German) Federal Research Institute for forestry and timber industry PI Page 5

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product / 3. Reasons for fibre breakage Example 2: Distribution of the ph-values in the topsoil of the Berlin conurbation Source: (German) Federal Institute for earth science and raw materials PI Page 6

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product 4. How to avoid network failures caused by water leakage into the joint-box 1. Use water sensor type 1550 and/or type 1625 within joint-boxes Use water sensor type 1310 and/or type 1550 within buildings, manholes or tunnels Fix the water sensor within the splice cassette, open the top of the sensor and lay the fibre into the sensor Close the top of the sensor Close the joint-box etc. Place the joint-box inside the manhole in such a way that the sensor is at the lowest point 2. Monitoring of optical cable networks A quick, simple method of servicing optical cable networks by means of water sensors is to carry out regular measurements (OTDR, Optical Power Meter, Remote Test System) on dark or active fibres at wavelengths 1310 nm, 1550 nm or 1625 nm, and to compare the resulting graphs with standard requirements. In this way cable lines of over 100 km can be quickly monitored and faults easily and precisely identified. In principle we recommend to clear disturbances within 6 months after detection or before there is danger of frost. An activated water sensor can be changed (after fault clearing, drying of joint-box, installation of a new sensor and measurement) without any interruption or disturbance in the functioning of the network. PI Page 7

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product Optical Fibre Water Sensor 5. How the water sensor works the water sensor will be activated within less than 5 minutes after water penetration the water sensor causes reversible attenuation changes in the monitored single mode fibre, which can be detected by measurement (optical power meter or OTDR) the fault position can be located precisely the attenuation change is reversible and will disappear after changing the sensor no damaging of the fibre Example 1: Sensor type WS1625 nm for monitoring of dark and active fibres [sensor type WS1625 Deutsche Telekom MNr. 401 861 28] at wave length attenuation change 1310 nm approx. 0,02 db 1550 nm 0,50 db 1625 nm 0,6-1,10* db OTDR measurement traces 1625 nm without water /with water *depends on the macrobending behaviour of the fibre Example 2: Sensor type WS1550 nm for monitoring of dark fibres at wave length attenuation change 1310 nm > 0,09 db 1550 nm > 1,8 db 1625 nm > 2,7dB OTDR measurement traces 1550 nm without water with water PI Page 8

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product 6. Dimensions of the water sensor 6.1 Water Sensor for installation into standard splice cassettes The Water Sensor will be clicked into the space provided for it opposite the splice holder in the splice cassette. Dimensions [mm] Water Sensor Type WS 1625 and WS 1550 6.2 Water Sensor for installation into FIST splice modules (Tyco Raychem) The Water Sensor will be sticked into the space provided for it in the splice module. Dimensions [mm] Type WS 1625 FIST and WS 1550 FIST PI Page 9

C:\Users\Public\Dieter Dokumente\Wolf\Wolf Info\Sensor\Englisch\[WO]-E Water Sensor (Product 7. Tips on how to instal the Water Sensor for reliable fault detection 1. Installation Ensure that the fibre is free of grease before laying it inside the water sensor Check that the fibre has enough space for some movement and that it shows no pressure marks Check that the fibre has unimpeded passage (measurement) Locate the exact position of the water sensor and record it in the event-table/ route plan. If location is not satisfactory, use a RTU/ OTDR with wider dynamic range or another type of instrument as necessary. (Advice obtainable from Wolf KT) 2. Labelling the joint-box Tx Cable LWL-Water sensor Rx Tape a label indicating the position of the water sensor onto the outside of the joint-box Place the joint-box inside the manhole in such a way that the sensor is at the lowest point Warning tape Sensor Attach a warning sign to the joint-box 3. Filling the manhole Check again that the water sensor is at the bottom of the joint-box and that the warning sign on the top is clearly visible PI Page 10