Drying and heating chambers. Series ED FD FED FP M

Similar documents
Drying and heating chambers

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Constant climate chambers. Always the right climate KBF KBF P KBF LQC KMF series

Model KBF 1020 Constant climate chambers with large temperature / humidity range

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Vacuum drying chambers. VD VDL series

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

CO₂ incubators. C CB series

Constant climate chambers

Ultra low temperature freezers

CO₂ incubators. C CB series

BINDER Product catalog

Product Highlights. BINDER Scientific with New Avantgarde.Line Products

Model KBF 240 Constant climate chambers with large temperature / humidity range

Environmental simulation chamber for complex alternating climate profiles

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

Constant climate chamber with ICH-compliant illumination

Model KBWF 240 Growth chambers with light and humidity

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Constant climate chamber with humidity

Constant climate chambers

Model C 170 CO 2 incubators with hot air sterilization

Vacuum drying oven for non-flammable solvents

Constant climate chambers

Model KBWF 720 Growth chambers with light and humidity

New Generation KBF 240 series

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Vacuum drying VD VDL series

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

Constant climate chambers

BINDER Industrial. Product Catalog

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Safety vacuum drying oven for flammable solvents

KMF Environmental test chamber for constant climate

Constant climate chambers

BINDER Scientific Product Catalog

NEW GENERATION. Efficient use of valuable space INCUBATORS

Thermo Scientific Heratherm Heating and Drying Ovens. Efficient, safe and easy

Thermo Scientific Heratherm Heating and Drying Ovens. efficient safe easy. Part of Thermo Fisher Scientific

Plant growth chambers

VD 53 - Vacuum drying oven for non-flammable solvents

Efficient, safe and easy

laboratory & sterilization technology

www

incubator, the best in its class

Thermo Scientific Heratherm Heating and Drying Ovens

Constant climate chambers

Thermo Scientific Heraeus Heating and Drying Ovens

Model Model version Art. No. Model Model version Art. No. BD V 9010/ FD V 9010/ BD 56

Forced Convection. Laboratory Ovens. Isotherm Forced Convection Laboratory Ovens, 110L, 54L and 32L models.

Thermal processing equipment design and craft for laboratories and industry Vilnius, Lietuva

Drying ovens, incubators, cooled incubators

HOT AIR OVEN. NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Environmental Chambers

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

laboratory & sterilization technology

HettCube INCUBATORS SUSTAINABLE. ERGONOMIC. HIGH QUALITY. INCUBATOR. Find out more by visiting:


ENVAIR lab CO2 Tri-Gas Incubator

Smart Oven (SWOF / SWON model) Oven (WOF / WON model) Precise Vacuum Oven (WOV model)

Thermo Scientific Heratherm Microbiological Incubators. safe. Part of Thermo Fisher Scientific

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

1,000W (DAP-60K: 100 W per digestion vessel)

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

ULTRA.GUARD ultra low temperature freezer

good reasons for a Memmert

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Benchtop CO 2 Incubator. the Oasis 6400 series

FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

HSD Dry Cabinet. Outstanding performance

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

HSD Dry Cabinet. Outstanding performance

Biological Incubators Biotech Ovens

FUNCTION LINE HEATING AND DRYING OVENS

VWR symphony CO 2 INCUBATORS

Intelligent. Powerful.

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Thermo Scientific Heratherm Heating and Drying Ovens. efficient

Laboratory thermostatic chambers

Compact Ultra Low Temperature Chamber

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

CO2 Incubators The Complete Line

ICH260C. Climate Chamber. Product specification

VACUUM HEATING AND DRYING OVENS Gentle and safe

Series of all-purpose physical and chemical environmental cabinets meeting the diverse needs of laboratories and research facilities.

BUSINESS SOLUTIONS. Biomedical REFRIGERATORS & FREEZERS FOR BIOMEDICAL NEEDS

Huminator II. Precision Humidity Generator. ww.testo.in

HSD Dry Cabinet

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

ZL Laboratory freezers

Epsilon 1-4 LSCplus Epsilon 2-4 LSCplus

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

OVENS. All our ovens are tested to meet electrical safety standard IEC EN , this standard provides additional security for laboratories.

Thermo Scientific Heratherm Microbiological Incubators

Transcription:

Drying and heating chambers Series ED FD FED FP M EN

Avantgarde.Line: Best in class The newly developed ED, FD, and FED series drying and heating chambers impress with their unparalleled performance. The spatial temperature accuracy is the best on the market. The units supports convenient operation and efficient working. 2

Table of contents Model 23 53 56 115 240 260 400 720 Series Page Drying and heating chambers Avantgarde.Line natural convection ED 6 forced convection FD 6 forced convection and enhanced timer functions FED 7 natural convection ED 10 Drying and heating chambers Classic.Line forced convection FD 10 forced convection and enhanced timer functions FED 11 forced convection and program functions FP/M 12 available not available 3

Drying and heating chambers Avantgarde.Line Drying and heating chambers Avantgarde.Line When it comes to drying, sterilization, or heating, BINDER drying and heating chambers with natural or forced convection ensure quality and reliability every time. Thanks to the extensive redevelopment they have undergone, these all-rounders are even more firmly focused on addressing the requirements of laboratories. Not only does the state-of-the-art design indicate the shape of BINDER product portfolios in the future, the convenient operation and efficiency plus outstanding temperature accuracy thanks to the very latest APT.line technology also make these pioneering units truly stand out. Avantgarde.Line with unparalleled performance Temperature distribution perfect and precise Superior, exceptionally accurate drying chambers Innovative unit design Simple and ergonomic door opening State-of-the-art controller ED 56 Verfügbare GröSSen Series 23 56 115 260 400 720 ED Classic.Line Avantgarde.Line Avantgarde.Line Avantgarde.Line Classic.Line Classic.Line FD Classic.Line Avantgarde.Line Avantgarde.Line Avantgarde.Line FED Avantgarde.Line Avantgarde.Line Avantgarde.Line Classic.Line Classic.Line FP Classic.Line Classic.Line Classic.Line Classic.Line Classic.Line M Classic.Line Classic.Line Classic.Line Classic.Line Classic.Line For information on Classic.Line, see page 8. 4

Avantgarde.Line Drying and heating chambers Get ahead with BINDER technology Completely homogeneous temperature distribution with excellent temperature uniformity and fluctuation thanks to the all-new generation of APT.line technology. Easy, intuitive handling thanks to state-of-the-art controller with LCD display, excellent readability, and various functions. The alphanumeric display makes it easier to communicate with the unit and read the data. Choice of languages as standard: English, German and French. Simple data recording via the USB connector which comes as standard and via Ethernet, which is available as standard for FED and as an option for ED and FD. Excellent energy efficiency and low connected load thanks to low heat dissipation and economical heating system. Figure shows FD and FED Ergonomic door opening based on a window handle principle: 6 o'clock = closed, 4 o'clock = open. 5

Avantgard.Line Series ED, FD Series ED Avantgarde.Line with natural convection Standard features Controller with LCD display Electromechanical control of the exhaust air flap 2 chrome-plated racks Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm USB port ED 56 Technical data of the Series ED Description ED 56 ED 115 ED 260 Basic data Interior volume [L] 57 114 255 Housing dimensions not incl. fittings and connections W x H x D [mm] 560 x 625 x 565 710 x 735 x 605 810 x 965 x 760 Performance Data Temperature Temperature range 15 C above ambient temperature to [ C] 300 Temperature range 8 C above ambient temperature to [ C] 300 300 Temperature uniformity at 150 C [± K] 2,5 2 - Temperature fluctuation at 50 C [± K] 0,4 0,4 - Heating-up time to 150 C [min] 45 60 - Recovery time after 30 seconds door open at 150 C [min] 25 20 - Energy consumption at 150 C [Wh/h] 180 250 - Series FD Avantgarde.Line with forced convection Standard features Controller with LCD display Electromechanical control of the exhaust air flap 2 chrome-plated racks Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm USB port FD 56 6

Series FED Avantgard.Line Technical data of the Series FD Description FD 56 FD 115 FD 260 Basic data Interior volume [L] 60 116 259 Housing dimensions not incl. fittings and connections W x H x D [mm] 560 x 625 x 565 710 x 735 x 605 810 x 965 x 760 Performance Data Temperature Temperature range 15 C above ambient temperature to [ C] 300 300 300 Temperature uniformity at 150 C [± K] 1,7 1,7 - Temperature fluctuation at 150 C [± K] 0,3 0,3 - Heating-up time to 150 C [min] 15 20 - Recovery time after 30 seconds door open at 150 C [min] 5 5 - Energy consumption at 150 C [Wh/h] 290 340 - Series FED Avantgarde.Line with forced convection and enhanced timer functions Standard features Adjustable fan speed Controller with LCD display with enhanced timer functions Electromechanical control of the exhaust air flap 2 chrome-plated racks Class 2 integrated independent adjustable temperature safety device (DIN 12880) with visual alarm Ethernet interface USB port FED 260 Technical data of the Series FED Description FED 56 FED 115 FED 260 Basic data Interior volume [L] 60 116 259 Housing dimensions not incl. fittings and connections W x H x D [mm] 560 x 625 x 565 710 x 735 x 605 810 x 965 x 760 Performance Data Temperature Temperature range 10 C above ambient temperature to [ C] 300 300 300 Temperature uniformity at 150 C [± K] 1,4 1,2 - Temperature fluctuation at 150 C [± K] 0,3 0,3 - Heating-up time to 150 C [min] 15 20 - Recovery time after 30 seconds door open at 150 C [min] 5 5 - Energy consumption at 150 C [Wh/h] 290 340-7

Drying and heating chambers Classic.Line Drying and heating chambers Classic.Line > 250.000 sold units of this technology As well as the new Avantgarde.Line drying and heating chambers, we also offer a wide selection of drying and heating chambers from our tried-and-tested Classic.Line and it goes without saying that these products offer outstanding levels of quality and process reliability too. You can choose from drying chambers with natural convection and forced convection, as well as programmable material test chambers. Classic.Line with tried-and-tested performance Fast and uniform tempering Temperature range up to 300 C Short heating up and recovery times User-friendly multi-functional control ED 400 Available sizes Series 23 56 115 260 400 720 ED Classic.Line Avantgarde.Line Avantgarde.Line Avantgarde.Line Classic.Line Classic.Line FD Classic.Line Avantgarde.Line Avantgarde.Line Avantgarde.Line FED Avantgarde.Line Avantgarde.Line Avantgarde.Line Classic.Line Classic.Line FP Classic.Line Classic.Line Classic.Line Classic.Line Classic.Line M Classic.Line Classic.Line Classic.Line Classic.Line Classic.Line For information on Avantgarde.Line, see page 4. 8

Classic.Line Drying and heating chambers Get ahead with BINDER technology Uniform drying conditions regardless of the sample size and number of samples thanks to BINDER APT.line preheating chamber technology. Convenient work environment thanks to the BINDER inner chamber concept: rack with tilt protection, no permanent fixtures, stainless-steel inner chamber. Wide range of applications thanks to wide temperature range up to 300 C. The FP and M series also impress with their adjustable air change rates and large power reserves. Individual programming via LCD screen controller with comprehensive program functions. The process parameters can be displayed differently. (M series) 9

Classic.Line Series ED, FD Series ED Classic.Line with natural convection Standard features Adjustable exhaust air flap Controller with timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm ED 400 Technical data of the Series ED Description ED 23 ED 400 ED 720 Basic data Interior volume [L] 20 400 720 Housing dimensions not incl. fittings and connections W x H x D [mm] 435 x 495 x 520 1.235 x 1.025 x 765 1.235 x 1.530 x 865 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 300 Temperature uniformity at 150 C [± K] 2,8 3 3,6 Temperature fluctuation at 150 C [± K] 0,5 0,5 0,5 Heating-up time to 150 C [min] 28 71 84 Recovery time after 30 seconds door open at 150 C [min] 28 31 34 Series FD Classic.Line with forced convection Standard features Adjustable exhaust air flap Controller with timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm FD 23 10

Series FED Classic.Line Technical data of the Series FD Description FD 23 Basic data Interior volume [L] 20 Housing dimensions not incl. fittings and connections W x H x D [mm] 435 x 495 x 520 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 Temperature uniformity at 150 C [± K] 2,5 Temperature fluctuation at 150 C [± K] 0,3 Heating-up time to 150 C [min] 25 Recovery time after 30 seconds door open at 150 C [min] 6 Series FED Classic.Line with forced convection and enhanced timer functions Standard features Adjustable fan speed Adjustable exhaust air flap Controller with expanded timer functions 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm Computer interface: RS 422 FED 720 Technical data of the Series FED Description FED 400 FED 720 Basic data Interior volume [L] 400 720 Housing dimensions not incl. fittings and connections W x H x D [mm] 1.235 x 1.025 x 765 1.235 x 1.530 x 865 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 Temperature uniformity at 150 C [± K] 3,8 3 Temperature fluctuation at 150 C [± K] 0,7 0,3 Heating-up time to 150 C [min] 29 29 Recovery time after 30 seconds door open at 150 C [min] 6 8 11

Classic.Line Series FP Series FP Classic.Line with forced convection and program functions Standard features Adjustable fan speed Adjustable exhaust air flap Controller with time-segment and real-time programming 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm Computer interface: RS 422 FP 53 Technical data of the Series FP Description FP 53 FP 115 FP 240 FP 400 FP 720 Basic data Interior volume [L] 53 115 240 400 720 Housing dimensions not incl. fittings and connections W x H x D [mm] 635 x 620 x 575 835 x 705 x 645 1.035 x 825 x 745 1.235 x 1.025 x 765 1.235 x 1.560 x 865 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 300 300 300 Temperature uniformity at 150 C [± K] 2 1,8 2 2,5 2 Temperature fluctuation at 150 C [± K] 0,3 0,3 0,3 0,3 0,3 Heating-up time to 150 C [min] 24 30 27 35 39 Recovery time after 30 seconds door open at 150 C [min] 5 8 10 17 20 12

Series M Classic.Line Series M Classic.Line with forced convection and advanced program functions Standard features Adjustable fan speed Program-controlled ventilation flap Color LCD controller with time-segment programming 2 chrome-plated racks Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm Computer interface: RS 422 M 720 Technical data of the Series M Description M 53 M 115 M 240 M 400 M 720 Basic data Interior volume [L] 53 115 240 400 720 Housing dimensions not incl. fittings and connections W x H x D [mm] 635 x 790 x 680 835 x 865 x 750 1035 x 985 x 850 1.235 x 1.185 x 870 1.235 x 1.695 x 970 Performance Data Temperature Temperature range 5 C above ambient temperature to [ C] 300 300 300 300 300 Temperature uniformity at 150 C [± K] 1,3 1,5 1,5 1,5 1,9 Temperature fluctuation at 150 C [± K] 0,3 0,3 0,3 0,3 0,3 Heating-up time to 150 C [min] 15 16 19 18 21 Recovery time after 30 seconds door open at 150 C [min] 3 3 3 3 3 13

Product overview Product overview Drying and heating chambers Model 23 53 56 115 240 260 400 720 Series Drying and heating chambers Avantgarde.Line Natural convection ED Forced convection FD forced convection and enhanced timer functions FED Natural convection ED Forced convection FD Drying and heating chambers Classic.Line forced convection and enhanced timer functions Forced convection and program functions Forced convection and advanced program functions FED FP M EXCERPT FROM OPTIONS AND ACCESSORIES Data Logger Kits Various different systems for recording temperature and humidity values Reinforced shelves to ensure safe and stable storage of heavy test specimens Access ports with silicone plug for connections to several measuring instruments SUCCESSFUL QUALIFICATION IQ/OQ qualification folder Supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, and QM certificate in accordance with ISO 9001 14

Product overview Temperature and timer functions Temperature range ambient temperature plus Delayed OFF Delayed ON Temperaturedependent delayed OFF Programming function Weekly program function Fans Computer interface Temperature safety class Temperature alarm Controller Page 8 C / 15 300 C USB 2 visual LCD 6 10 C 300 C USB 2 visual LCD 6 10 C 300 C Adjustable USB/ Ethernet 2 visual LCD 7 5 C 300 C RS422 2 visual LED 10 5 C 300 C 2 visual LED 10 5 C 300 C Adjustable RS422 2 visual LED 11 5 C 300 C Adjustable RS422 2 visual LED 12 5 C 300 C Programmable RS422 2 visual LCD 13 available not available 15

BINDER GmbH Tuttlingen, Germany Tel +49 7462 2005 0 Fax +49 7462 2005 100 info@binder-world.com www.binder-world.com Representative Office for CIS Moscow, Russia Tel +7 495 988 15 16 Fax +7 495 988 15 17 russia@binder-world.com www.binder-world.ru BINDER Asia Pacific (Hong Kong) Ltd. Kowloon, Hong Kong, P.R. China Tel +852 39070500 Fax +852 39070507 asia@binder-world.com www.binder-world.com BINDER Inc. Bohemia, NY, USA Tel +1 631 224 4340 Fax +1 631 224 4354 usa@binder-world.com www.binder-world.us BINDER Environmental Testing Equipment (Shanghai) Co., Ltd. Shanghai, P.R.China Tel +86 21 685 808 25 Fax +86 21 685 808 29 china@binder-world.com www.binder-world.com 7002-0274_V09-2015 Deviations from the figures, information, and technical data are reserved.