COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST

Similar documents
Incident Summary (II )

Direct Vent Training & Installation Instructions for Venting 40/50 gallon models Telescoping Vent Kit (standard)

Flues and chimney systems

A totally renewable heat source

tççç= ÜÉ~íáåÖ çéíáçåë

TONAdin triple-wall insulated chimney of round design. TONAtec plus air/flue chimney for all fuel types (specifically biogenic solid fuels)

A totally renewable heat source

Flues and chimney systems

Combustion Air System DVL. DuraBlack. Triple-wall stovepipe system designed to provide air for combustion through its components. ULC S641.

Z-DENS Z-FLEX. Polypropylene Vent Systems for High Efficiency Condensing Appliances. Single Wall Rigid Flexible Liner Concentric

Importance of a Draught Regulator

Chimney Renovation Kit

Technical Bulletin. Concealed extended flues

Forced Draft Boiler Flue Gas Venting: Problems & Solutions. Presented by Steve Connor and Patrice Gouin January 27, 2016

Air and technology System solutions with a perspective... System solu

Technical Guidance CE Marking of Metal Chimneys and Flues

Fundamentals of Making Energy-Saving and Cost-Efficient Boiler Exhaust Systems Design Solutions and Applications

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

CHAPTER 8 CHIMNEYS AND VENTS

FOR 24/7 EXPERT SUPPORT PLEASE CALL: Technical Support: Warranty Support:

FLANGED CORR/GUARD CORR/GUARD INSTALLATION INSTRUCTIONS

"Let's provide you with a superior User Experience delivering Ease-of-Mind."

Mechanical chimney draught & heat recovery

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

clearfire Large capacity condensing boilers 4,000 to 12,000 MBTU/hr

Residential Product Selection Guide

GB162 Concentric Horizontal Vent Kit

UltraOil Condensing Oil Boiler

Condensing Boilers. High Efficiency. Proven Reliability, American-Made Home Heating Comfort. ANYWHERE UNMATCHED

CHAPTER 8 CHIMNEYS AND VENTS

EXCEL. ULTRABlack THE MOST DURABLE, EASIEST TO INSTALL RESIDENTIAL CHIMNEY SYSTEM YOU CAN BUY NEVER EVER BUY ANOTHER STOVE PIPE

TW-Pro. Twin Wall Insulated Flue System EN T600 N1 W V2 L50040 G50 / O40

CHIMNEYS AND VENTS CHAPTER 8

CHAPTER 6. HEATING PRODUCTION EQUIPMENT AND SYSTEMS

NEW * for buildings 2-24 floors

Technical Bulletin MODELS AFFECTED SW3, SW3T SW4, SW4T SW5, SW5T

CHIMNEY INSTALLATION. Technical Bulletin #1

Bring In the Fresh Air

REHAU Radiant Heating Systems. A warm welcome

Corr/Guard PRESSURE RATED VENTING SYSTEM IMPORTANT: DO NOT INSTALL WITHOUT FIRST READING THESE INSTRUCTIONS VERY CAREFULLY.

DRUM DRYERS FOR THE WOOD PELLET INDUSTRY

Venting Supplement. Direct Vent Through-Roof or Through-Unused-Chimney. Water Boiler Series 3 & 4

The intelligent alternative for flue gas venting systems

C. Manufactured double wall chimneys for fuel fired equipment. D. NFPA 54 - National Fuel Gas Code; National Fire Protection Association; 2009.

BUDERUS. Quality. Versatility. Efficiency. Superior Design. Comfortable. Efficient. Intelligent Heating. Conventional Gas Boilers

HIGH-EFFICIENCY COMMERCIAL PRODUCTS

Fire Chief Wood/Coal Burning Furnaces

Put the V back in HVAC

Energy Options for Residential Heating. Juergen Korn, P.Eng.

SMALL DIAMETER CORR/GUARD & SLEEVED CORR/GUARD

Consumer Features & Benefits of Energy Efficient Products

High impact design for low-energy homes

Riva Studio Dedicated Sealed External Air Kit

State of New Jersey BOARD OF PUBLIC UTILITIES 44 SO. CLINTON STREET 7 TH FLOOR P.O. BOX 350 TRENTON, NEW JERSEY

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

TECHNICAL TRAINING IN DRYING WITH BIOMASS BASED DRYERS INTRODUCTION TO DRYING AND BIOMASS DRYERS

R A N G E C O N C E P T

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

DK-HEAT RECOVERY FOR TRANSCRITICAL CO 2 REFRIGERATION SYSTEMS

Technology Menu Hospitality Laundry

AMBIRAD.... Vision Radiant Tube Heating Systems...

WHHR Midi & Midi Lite

THE BURNING ISSUE FOR BODYSHOPS

By Bernard Dalsin Mfg. Co. Installation and Operating Instructions Read these instructions and keep them for future reference

AUTOMATION OF BOILERS USING LABVIEW

EXHAUST SYSTEMS COMMERCIAL CHIMNEY LINING SYSTEMS.

NO ONE PUTS MORE INTO THEIR POOL HEATERS

Technology Menu Commercial Laundry

84 PROFESSIONAL - IN A CATEGORY ALL ITS OWN

Gas wall system and combination boilers. Why Vaillant? For more technology and experience. atmotec plus turbotec plus atmotec pro turbotec pro

PelletVent Pro. Biofuel venting system. UL 641, ULC S609, and ULC/ORD C441.

/13 Price - $5.00

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

about your house Before You Start an Energy-Efficient Retrofit Mechanical Systems

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

Green Building Practice Summary 3/10/2011

GWS. Venting Manual. Gas-Fired Water Boilers. Hazard definitions. Contents. Venting method definitions

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Advanced Venting Systems

Bosch 80% AFUE Gas Furnace BGS80 Model

Energy consumption in properties

Leading European manufacturer of fireplace stoves and fireplace inserts

90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer

ENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.

RADIANT HEAT. Construction Automotive Industry

A BRIGHT IDEA FOR THE GREEN BUILDING INDUSTRY WHITE ARMOR HIGH REFLECTANCE COOL ROOF GRANULES

TopGas Wall Hung Condensing Gas Boiler

JENROLL EXPG the gas-heated, self-contained ironer

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

FLEXIT S4 X/TT - A4 X/TT S7 X/TT - A7 X/TT

G215 G315 Cast Iron Residential Boilers

Automating functions. Simplifying operations. Modernizing protection. Bebco EPS 5500 Automation for Purge and Pressurization

Madhu Honap HONEYWELL THERMAL SOLUTIONS INTRODUCTION

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

Transcription:

COMBINATION SOLUTION FOR COLLECTIVE FLUE, AIR VENTILATION AND EXHAUST SAVING PLACE IN THE SLEEVE SO IT CAN BE DESIGNED SMALLER ONLY ONE ROOF TERMINAL IMPROVING THE AESTHETIC ASPECT TIME- AND COST-EFFECTIVE AS ONLY ONE CHIMNEY HAS TO BE PLACED

Combination solution for collective flue, air ventilation and exhaust The OPSINOX TRIPLE FLOW product range, combines the air flows from both the heating boilers as the ventilation systems in a single chimney. The OPSINOX TRIPLE FLOW consists of 3 concentric ducts in which the air flows from the heating boilers as the ventilation system can be foreseen. The flue gases are discharged through the inner duct and blown out at the top op the roof cap, where as the fresh air for the combustion boiler is supplied via a second inner duct. The outer duct takes care of the removal of contaminated ventilation air, which is blown away laterally in the top element. Easy installation The OPSINOX TRIPLE FLOW is easy to install by the proven system of modular chimney elements with male/female connections. The individual elements are supplied with a clear installation plan so that the chimney can always be assembled correctly. Safe combustion and healthy ventilation The OPSINOX TRIPLE FLOW is designed for the connection of closed heating boilers whose combustion circuit is completely separated from the living areas, what makes the risks associated to poor combustion impossible. Proper ventilation is the base for a healthy indoor environment at your home, so it is important the ventilation system can operate optimally. By connecting the Healtbox from Renson on the OPSINOX TRIPLE FLOW, you lay the foundation of a healthy apartment! Developed in collaboration with the Renson Healthy Apartment Concept As leader in the market in ventilation, Renson is the perfect partner for Opsinox, Belgium s largest producer in flue ducts, to develop this innovation successful. The Renson and Opsinox engineers have developed the patented OPSINOX TRIPLE FLOW system for the purpose of a use- and ease effective installation, which goes hand in hand with a flawless and low maintenance system. Scope The OPSINOX TRIPLE FLOW is the ideal solution for all your projects where multiple units are connected to a central chimney where a decentralized heating and ventilation system is required. This allows each user to enjoy the many benefits offered by its own boiler and its own ventilation system, but still having to provide only one central exhaust duct.

In the top element the various air flows are vented out in a different direction in order to rule out merging of flows Easy connection of the heating boiler and the Renson Healthox

Space saver By already providing the OPSINOX TRIPLE FLOW at the design phase, the technical ducts can be dimensioned up to a 50% smaller. With the ever-rising real estate prices, every square meter useful floor area translate itself directly in increased profitability of the project. An Opsinox representative helps you determine the minimum achieve tube dimensions for your project. Aesthetic Done with tangle on roof outlets. The OPSINOX TRIPLE FLOW needs only one element to eliminate both your combustion gases and ventilation air. Besides the aesthetic advantage, a reduction in the number of roof passages means also a lower heat loss through the roof, as the number of construction nodes are reduced to an absolute minimum. In a sector increasingly seeking for energyefficient homes, it is important to avoid these construction nodes as much as possible! Time and cost saving For the project leader, it is often a challenge to keep track of the many subcontractors and suppliers on site. While traditionally the ventilation system and flue ducts are placed by various parties and placed at different times, the Opsinox Triple Flow can be placed by one team only. Scenarios where after placing the chimney free duct space appears to be too small for ventilation ducts, belong to the past!

Migratory cap OVTOP Adapter TOP Top element Roof passage 10-35 Roof passage 30-45 Storm collar Roof passage for a plat roof Wall support with extension up to 750mm Connection Wall support with extension up to 500mm Duct element long Duct element small BR500 Connection Bottom element on wall support OVBODEM Adapter bottom Condensate tray ventilation duct Duct element small Bottom element on wall support Bottom element