IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx SIR 06.0082X issue No.:7 Status: Current Date of Issue: 2016-03-30 Page 1 of 4 Applicant: Hawke International A Division of Hubbell Limited A Member of the Hubbell Group of Companies Oxford Street West Ashton-Under-Lyne Lancashire OL7 0NA United Kingdom Certificate history: Issue No. 7 (2016-3-30) Issue No. 6 (2010-9-7) Issue No. 5 (2010-5-21) Issue No. 4 (2009-9-18) Issue No. 3 (2009-6-3) Issue No. 2 (2008-10- 28) Issue No. 1 (2008-2-18) Issue No. 0 (2006-11- 30) Electrical Apparatus: Optional accessory: Type 753, 755, S753, 710 and 711 Compound Filled Cable Glands Type of Protection: Flameproof, Increased Safety, Type n and Dust Marking: Ex db IIC Gb Ex e IIC Gb Ex nr IIC Gc (option applicable to 753, 755, 710 & 711 Cable Glands) Ex tb IIIC Db IP66 Temperature at point of installation. = -60 C to +80 C or -50 C to +60 C Approved for issue on behalf of the IECEx Certification Body: Position: C Ellaby Deputy Certification Manager Signature: (for printed version) Date: 2016-03-13 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the Official IECEx Website. Certificate issued by: SIRA Certification Service CSA Group Unit 6, Hawarden Industrial Park Hawarden Deeside CH5 3US United Kingdom
IECEx Certificate of Conformity Certificate No.: IECEx SIR 06.0082X Date of Issue: 2016-03-30 Issue No.: 7 Page 2 of 4 Manufacturer: Hawke International A Division of Hubbell Limited A Member of the Hubbell Group of Companies Oxford Street West Ashton-Under-Lyne Lancashire OL7 0NA United Kingdom Additional Manufacturing location (s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition: 6.0 IEC 60079-1 : 2014-06 Edition: 7.0 IEC 60079-15 : 2010 Edition: 4 IEC 60079-31 : 2013 Edition: 2 IEC 60079-7 : 2006-07 Edition: 4 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d" Explosive atmospheres - Part 15: Equipment protection by type of protection "n" Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure "t" Explosive atmospheres - Part 7: Equipment protection by increased safety "e" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST & ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/SIR/ExTR06.0104/00 GB/SIR/ExTR07.0131/00 GB/SIR/ExTR08.0137/00 GB/SIR/ExTR09.0071/00 GB/SIR/ExTR09.0144/00 GB/SIR/ExTR10.0084/00 GB/SIR/ExTR10.0212/00 GB/SIR/ExTR16.0069/00 Quality Assessment Report: GB/BAS/QAR06.0061/00
IECEx Certificate of Conformity Certificate No.: IECEx SIR 06.0082X Date of Issue: 2016-03-30 Issue No.: 7 Page 3 of 4 Schedule EQUIPMENT: Equipment and systems covered by this certificate are as follows: These compound filled cable glands are intended to terminate elastomeric insulated circular, unarmoured, single steel/aluminium wire or single/double tape armoured or braided cables (as defined by their model designations clamping mechanism and cable range accommodation) into a threaded entry point on associated flameproof or increased safety equipment without compromising the explosion protection provided by the enclosures in accordance with relevant codes of practice. They consist of a male-threaded, front entry component that is fitted with a compound pot such that a spigot/combination joint is formed, which is intended to screw into an entry point on its associated enclosure. The compound pot contains an epoxy barrier compound, this is retained by the spigot component and makes a flameproof seal around the cable cores that pass through it. Electrical continuity of any armour or braid is effected between the spigot and clamping ring components within the middle nut that is fastened to the front entry component assembly. A sub-assembly, comprising a backnut, seal grip and elastomeric seal, threads onto the middle nut providing additional environmental sealing against the cable outer sheath. The Type 755 compound filled cable glands are formed by inserting an alternative armour ring into the Type 753 range of compound filled cable glands, they are suitable for elastomeric insulated, circular, single steel/aluminium wire armoured, lead or elastomeric inner sheathed cables only. The S753 glands are similar to the 753 but are fitted with a different entry component, compound pot and spigot components. For design options, model codes and gland selection, refer to the certificate Annexe. CONDITIONS OF CERTIFICATION: YES as shown below: 1. The entry component threads will be suitably sealed using a method that is applicable to the associated equipment to which the gland will be attached, this will be in accordance with the relevant, installation code of practice and will ensure that any ingress protection and restricted breathing sealing requirements are maintained. 2. The maximum constructional gap (Ic) of the cylindrical flamepath is less than that required by Table 2 of IEC 60079-1:2003, as follows: 0.083 mm between the compound pot and entry component bore of the 753 and 755 cable glands 0.125 mm between the compound pot and entry component bore of the S753 cable glands
IECEx Certificate of Conformity Certificate No.: IECEx SIR 06.0082X Date of Issue: 2016-03-30 Issue No.: 7 Page 4 of 4 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Refer to ANNEXE. Annex: IECEx SIR 06.0082X Issue 7 Annexe.pdf