IMPORTANT: Read and save these instructions.

Similar documents
Electric Built-in Ceramic Cooktops

Combination. IMPORTANT: Read and save. these instructions. Par-t No W / Rev. A

Undercounter Dishwasher

Electric Built-in 24 and 27 Thermal Single and Double Ovens 24 and 27 Thermal Convection Single and Double Ovens

Viking Installation Guide

Washer 220/240-volt, 60-Hz Models

Installation. Built-in Full Height Wine Cellar VCWB301

Room Air Conditioners

Microwave Oven Hood Combination

Installation Instructions

IMPORTANT: Read and save these instructions. 24 and 30 Convertible Range Hood. Part No Rev. E

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Care and Cleaning Air Filter...5 Grille and Case...5 Outdoor Coils...5

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm)

Installation Instructions

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Viking Installation Guide

Installation Instructions

Undercounter Dishwasher

Installation Instructions

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

Installation Instructions

Installation Instructions

Multi-Function Cooktop

Room Air Conditioners

Viking Installation Guide

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

Installation. All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Washer. 120~volt 60-Hz. IhilPORTANT: Read and save these instructions. Parts supplied:

INSTALLATION INSTRUCTIONS

Installation Instructions

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

DRYER INSTALLATION INSTRUCTIONS

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

Installation Instructions

Installation Instructions

Helpful Tip: NOTE:

Installation Instructions

Installation Instructions

Downdraft Ventilation

Installation Instructions

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Over-the-Range Microwave Oven Installation Instructions MVH130* MVH230* MVH330*

Installation Instructions

Installation Instructions

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Instructions

Advantium TM. Built-In. Speedcook Ovens. Installation. Instructions

Installation Instructions

Undercounter Refrigeration

Installation Instructions

Installation Instructions

Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

Installation Instructions Wall Ovens

Installation Instructions

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

2 PREPARE THE OPENING

Installation Instructions

Installation Instructions

Installation Instructions

ELECTRIC WALL OVEN INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Viking Installation Guide

Room Air Conditioner & Heat Pump Use and Care Manual

Installation Instructions

Installation Instructions READ BEFORE INSTALLING UNIT For SLO3 Air Conditoner (8,000~12,000 BTU)

INSTALLATION GUIDE Fryer Module

Quick Reference. 27" and 30" Electric Built-in Microwave/ Oven Combination. Table of Contents: If you need assistance: Pages

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation Instructions

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

24 IN. (61 CM) ELECTRIC WASHER/DRYER INSTALLATION INSTRUCTIONS WASHER/DRYER SAFETY DANGER WARNING

GAS COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Induction Cooktops

Installation Instructions

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation Instructions

Transcription:

MPORTANT: Read and save these instructions. MPORTANT: nstaller: Leave nstallation nstructions with homeowner. Homeowner: Keep nstallation nstructions for future reference. Save nstallation nstructions for local electrical inspector s use. Air Conditioner Part No. 1166071

Before you start... Proper installation is your responsibility. Make sure you have everything necessary for correct installation. t is the customer s responsibility to comply with the installation specifications provided. Grounded electrical outlet within reach of the power supply cord is required. See Electrical requirements. t is the customer s responsibility: l To contact a qualified electrical l To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANWNFPA 70 - latest edition,* and all local codes and ordinances. fire, lectrical shock or other personal Check location where air conditioner will be installed. The location should provide: l A window large enough, l Adequate wall support for weight of air conditioner, l An electrical outlet within reach of power supply cord, l Free movement of air to rooms to be cooled. Copies of the standards listed may be obtained from: l National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 Tools and materials needed for fnstallatlon: tape measure socket wrench 7/l 6 socket & l/4 socket v ml ( 2tYx40 * Electrical outlet must be available within reach of power supply cord. Do not use extension cord. mportant: Observe all governing codes and ordinances. Electrical requirements und is required on this und to a gas pipe. l Do Not modify the power supply cord plug. f it does not fit the outlet, have a proper outlet installed by a qualified electrician. l Do Not have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock. l Do Not use an extension cord with this appliance. l Check with a qualified electrician if you are in doubt as to whether the appliance is properly grounded. l Grounding wire must be connected to grounding screw located in lower right corner of air conditioner when air conditioner is in cabinet. Personal njury/product Damage Hazard l Because of the weight and size of the air conditioner, more than one person is needed to move, lift and safely install it. l Handle air conditioner with care. Metal fins on front and rear coils are sharp. l Do Not use the water that collects inside the air conditioner for drinking purposes. t is not sanitary. l Maintain a firm hold on the air conditioner to prevent it from falling out of the window during installation. l Do Not locate air conditioner where cabinet front is exposed to a heat source that raises the surface temperature above 120 F. Failure to follow these instructions could result in personal injury or damage to air conditioner. Specific electrical requirements are listed in the chart. Follow the requirements for the type of plug on the power supply cord. Wiring requirements Disconnect power supply cord from receptacle before servicing. Failure to follow these instructions could result in serious injury or death. Note: Refer to model and serial label for BTU capacity, amperage, voltage and refrigerant charge specifications. Plug type Electrical requiremeni 115volt 12.0 amperer 230~volt and 230/208-votl 12.0 amperes Minimum receptacle wire size gcluige gag e Through-the-wall installations: wood preservative 10, #lo x 1 Parts supplied for installation: f codes permit and a separate grounding wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate. A single-phase, 60-Hz, AC-only, electrical supply is required on a separate circuit. A time-delay fuse or circuit breaker is required - 15amp for models without electric heater and 30-amp for models with electric heater. The fuse size must not exceed the current rating specified on the model and serial label. The model and serial label is located behind the front panel on the base flange. 230~votl and 230/208-voli 16.0 amperes 230~voll and 230/208-votl 24.0 amperes 12 WJW 10 gauge Regrdmended grounding #8 x i 12 hex-head, metal nstallation parts are supplied for doublehung windows up to 40 inches wide. nstallation up to 54 inches can be made with a special, wide window kit available from your dealer or service center. Panel A For your personal safety, this appliance must be grounded. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating, 3-prong grounding-type wall receptacle, grounded in accordance with the National Electrical Code, ANS/NFPA 70 - latest edition*, and all local codes and ordinances. f a mating wall receptacle is not available, it is the personal responsibility and obligation of the customer to have a properly grounded, 3-prong wall receptacle installed by a qualified electrician.

Now start... With air conditioner be installed. in room where it will WNDOW NSTALLATON O H nsert other filler board into window channel on opposite side of cabinet. Push filler board against sidemounting angle and attach with two, l/2 hex-head, Raise window sash. power SP See Panel C for through-the-wall installation. Front view ot unit with front panel removed. side view 5 n Place cabinet in window. Lower sash (window frame) to hold cabinet in place. Measure the distance between the side of the cabinet and inside of the window channel at the top and bottom of the cabinet. Adjust the cabinet until the distance on each side (top and bottom) is the same, so the cabinet is centered in the window. Write down the final measurements. 11 w From the outside, push filler boards as far forward in window channels as possible. 12 n Measure the distance between the channel edge and the filler board. Cut foam blocks l/4 wider. nsert blocks into channel behind filler boards. 1 n Loosen but Do Not remove the grounding wire screw. Disconnect grounding wire.. +A2 4 t &Al + t Kr board c Floor Damage Remove air conditioner from carton and place on cardboard. to floor covering. t 4 +e2- + LB1 + 6 n Add l/8 to both open area measurements. Use a utilitv knife to cut filler boards to fit. 3 n Measure from inside edae of window frame to other inside ed:e. Cut foam seal with square ends to fit. Align foam seal with front edge of window sash and attach seal with adhesive side against underside of sash. f. a: :: mountlng 5 angle seal back of filler board Property Damage Check that air conditioner cabinet is tilted to the outside so that water will run to the outside. to floor covering, window sill or wall. 2 n Attach 3/8 seal strip to the bottom of both side-mounting angles (side with two holes). Cut strips to length 4 front of filler board 4 7 w Apply 3/8 seal strips to bottom and outside of filler boards. The top seal goes on back side of filler boards. 3 n Attach the side-mountina anales. with two, hex-head metal u&g l/4 socket and socket wrench or 1 /S nut driver. Pull cabinet \Ejz window. Attach one two, l/2 hex-head. L-----l 14 w Lower window sash. Place level inside cabinet on the right side. There should be a tilt to the outside of approximately one bubble. Place the level on the left side and check. 15 H Use a 3/32 drill bit to drill starter holes in the cabinet and into the window sill. Fasten cabinet to the sill with two wood. 4 n Pull on handles; slide air conditioner out of cabinet and place on cardboard. Panel B 9 n Place cabinet back into the window with filler board tight against window channel.

4 n nsert the frame in the wall opening. Square and level frame. Nail frame securely to the wall studs. \scregs 20 n Attach front by first removing the two, #8 x 3/8 from base; then insert front tabs into top of cabinet and swing front in place. Attach bottom of front by reinserting the two. Floor Damage Remove air conditioner from carton and place on cardboard. to floor covering. 16 n Secure vertical and angle THROUGH-THE-WALL NSTALLATON supports together. Attach suppofis to bottom of cabinet. But Do Not tiahten bolts at this time. Attach wall rail to angle supports. Slide each support assembly toward house until wall rail is positioned firmly against wall. Note: f your house is constructed of material that could be damaged by wall-mounting support, fasten a board between wall rail and house. 17 n Tighten bolts securely with a 7/l 6 socket-and socket wrench. Tighten angled support bolts last so wall rail fits tightly against house. plaster NSTRUCTONS... FOR SLDE-OUT CHASSS MODEL ONLY. t is the customer s responsibility and obligation to have this product installed by a qualified technician familiar with through-the-wall room air conditioner installations. -f+l trim_ appropriate header f required casfng / gro;;zlng 5 n Loosen but Do Not remove the grounding wire screw. Disconnect grounding wire. Personal njury/product Damage Hazard nstall window-lock bracket to prevent air conditioner from falling out of window. personal injury or product damage. alternate constructlon for plaster l-3/16 clearance f power supply cord x Frame construction apprwhte header f reaulred..-...- thickness. 6 n Pull on handles; slide air conditioner out of cabinet and place on cardboard. plaster l/2 Al trlm 1 n nsert cabinet into wall opening. The top of the cabinet should extend l/2 inch into room. f there is trim, the cabinet should extend l/2 inch in front of trim. 18 n nsert window rail seal behind the top of the lower window sash and against the glass of the upper window. Place window-lock bracket on top of lower window and against upper window sash. Use a 3/32 drill bit to drill a starter hole through the hole in the bracket. Attach window-lock bracket with wood screw. Seal small openings around window with gum-type sealer. Grounding wire from the air conditioner must be connected to the cabinet. electrical shock. alternate construction for plaster Provlde l-3/1 6 clearance for p ;e~$~prd ent l-3/16 clearance for use 26 dlmensl r&n Brick veneer construction 1 n When using a wood, metal or plastic molding, the finish frame should line up with inside wall. f the plastered wall is to be flush with the cabinet and no molding is used, the finish frame must be set l/2 inch into the wall. 19-3/4 (ncludes allowance tor l/2 flange on bottom of cabinet). type of molding. hopetty Damage Check that air conditioner cabinet is tilted to the outside so that water will run to the outside. to floor covering or wall. 8 n Place level inside cabinet on the right side. There should be a tilt to the outside of approximately one bubble. Place the level on the left side and check. 9 n Use the insulation removed in Step 2 to seal opening between cabinet and frame. 10 H Drill four holes on each side and two through the top of the cabinet into the frame. Use ten, #lo x 1 wood (not provided) to attach cabinet to frame. Do Not overtighten or cabinet will distort and provide a poor air seal between cabinet and air conditioner. 19 n nsert air conditioner into cabinet. Reattach grounding wire to grounding screw. Put excess grounding wire between coil and grey beaded foam. Panel C 2 n Cut opening through the wall. Remove insulation. 3 n Use 1 -inch or heavier lumber for wood frame. Measure depth of wall opening and frame. Apply wood preservative to the outside exposed surface.

11 n Place drain c hole in cabinet rail as shown. Electrical Shot k Hazard Grounding wire from the air conditioner must be connected to the cabinet. electrical shock. 13 screk n Attach front bv first removinq the two, #8 x 3j8 from base; then insert front tabs into top of cabinet and swing front in place. Attach bottom of front by reinserting the two. 14 n Caulk all outside wall openings around cabinet. 15 n f needed, install molding around room side of cabinet. f your air conditioner operating properly... is not Check that the circuit breaker is not tripped or house fuse blown. Check that power supply cord is securely plugged into the electrical outlet. f you need assistance... Check your Use and Care Guide for a toll-free number to call, or call the dealer from whom you purchased this appliance. The dealer is listed in the Yellow Pages of your phone directory under Appliances - Household - Major - Service and Repair. When you call, you will need the model number and serial number. Both numbers can be found on the model and serial label located behind the front panel on the front flange of the base. 12 n nsert air conditioner into cabinet. Reattach grounding wire to grounding screw. Put excess grounding wire between coil and grey beaded foam. Printed on recycled paper. 10% post consumer waste/ 50% recovered materials. Part No. 1166071 0 1994 Benton Harbor, Michigan 49022 Printed in U.S.A.