HOA6480 Series Barcode Sensor Infrared Products

Similar documents
The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

HIH-4602-L Series Humidity Sensors


Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

HIH-4000 Series Humidity Sensors

HFX Fiber Optic Component 50 Mbps, 650 nm LED

FSS-SMT Series. Low Profile Force Sensor

V-Basic Standard V15 Series

HIH-5030/5031 Series Low Voltage Humidity Sensors

FEATURES AND BENEFITS

High Temperature Industrial VRS Magnetic Speed Sensors

General Purpose Industrial VRS Magnetic Speed Sensors

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Linear Current Sensors

Potential Applications

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

Interactive Catalog Replaces Catalog Pages

MICRO SWITCH GSX Series

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

MICRO SWITCH GLL Series

MICRO SWITCH V15W Series Watertight Miniature Switches

Installation Instructions for the

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Installation Instructions for the 600 Series Optical Encoders

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Installation Instructions for the

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

HIH-4030/31 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

MICRO SWITCH NT Series

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

MICRO SWITCH NT Series

1HP Series. Aerospace-Grade Pressure Switch High Pressure Series. precise, demanding requirements of aerospace and defense applications.

HIH-4010/4020/4021 Series Humidity Sensors

CONDUCTIVITY SPECIFICATIONS TEMPERATURE SPECIFICATIONS. PDFINFO p a g e

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

WARNING MISUSE OF DOCUMENTATION

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Wireless Panel-Mount Monitor

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Interactive Catalog Replaces Catalog Pages

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Issue 1. MICRO SWITCH Rocker Switches TP Series. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS PORTFOLIO VALUE TO CUSTOMERS

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

MICRO SWITCH BX/BX2 Series

FF-ST4 Series. Type 4 Safety Light Curtains. Potential Applications. Features

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

LCZ Series Hall-effect Zero Speed Sensors

Intrinsically Safe Transmitters, Option Code 2n

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 4. Datasheet

High Sensitivity Latching Digital Hall-effect Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-T3 SS460S-LP

Airflow Sensors Line Guide

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Sensor Evaluation Kit, SEK001

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

HIH-4602 A & C Series.

Quadrature Speed and Direction Sensors

MICRO SWITCH Sealed Subminiature Basic Switches ZD Series Issue 3. Datasheet

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Guide to Hazardous Location Approvals:

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

AMR 4-Pin Quadrature Sensor Integrated Circuit

Airflow Sensors Line Guide

Fiber Optics and Liquid Level Sensors Line Guide

Selecting Honeywell Board Mount Pressure Sensors

Sensing and Control. Figure 1. SMART Position Sensor, 100 and 180 Arc Configurations

MICRO SWITCH BAF/DTF Series

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Force Sensors Line Guide

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

MICRO SWITCH E6/V6 Series

TruStability Board Mount Pressure Sensors

Transcription:

HOA6480 Series Barcode Sensor Infrared Products DESCRIPTION The HOA6480 Series is a reflective barcode sensor that incorporates a VCSEL (Vertical Cavity Surface-emitting Laser) emitter and phototransistor detector in a custommolded plastic package. The VCSEL technology allows the sensor to operate with a very low drive current. The phototransistor drives an operational amplifier with an open-collector output, providing users with flexibility in their interface designs. FEATURES Class IIIB VCSEL Digital output Depth of field: 4,5 mm ±0,5 mm [0.180 in ±0.20 in] Focal length: 4,5 mm [0.180 in] Resolution: 0,254 mm [0.010 in] Choice of pin, wire or custom termination DANGER The HOA6480 Series provides a digital output that allows it to be interfaced with most decoding equipment. The 4,5 mm [0.180 in] focal length allows measurement with no contact and the 0,254 mm [0.010 in] resolution works well in most barcode applications. The HOA6480 typical scan speed is 254,0 mm [10.0 in] per second. A choice of pin, wire or custom termination allows flexible interconnections and the reflective sensor configuration promotes easy mounting. POTENTIAL APPLICATIONS Barcode verification in dispensing and processing equipment Line or edge detection Encoding Data collection from manufacturing lines, robotic operations, production instrumentation/control units, automated sorting and screening equipment and analytical systems such as medical analysis. (Note that carbon black ink is required for this device to sense lines.) INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM PEAK POWER 5 mw WAVELENGTH 820-860 nm CLASS IIIb LASER PRODUCT

HOA6480 Series Barcode Sensor TESTING PROCESS Each HOA6480 Barcode Sensor is precisely tested using automated testing equipment and a custom fixture. During the testing process, the test fixture holds each sensor at a distance of approximately 4,5 mm [0.180 in] from a rotating wheel with a diameter of 89,0 mm [3.5 in] and a height of 15,2 mm [0.600 in]. One half of the wheel consists of a 50 % duty cycle barcode of alternating black and white stripes of the same size (0,38 mm [0.015 in] wide and 16,2 mm [0.600 in] tall). The other half of the wheel has a sample barcode of a known value. The wheel rotates at 1 RPS (~254,0 mm [10.0 in] per second). Power, ground and output connections are applied to the sensor loaded into the test fixture. Custom software in the test system evaluates the duty cycle collected by the sensor and sets the desired duty cycle between 40 % and 60 %. The software then reads a sample barcode and verifies that an accurate and complete barcode signal has been collected. REFLECTIVITY The sensor output will be below 1.1 V when presented with a 50 % reflective surface at 6,35 mm [0.250 in] (Kodak Grey Scale #3, CAT 152 7662). ELECTRICAL CHARACTERISTICS (25 ºC [77 ºF] unless otherwise noted) Parameter Min Typ. Max Unit Condition Supply current 15 ma all Voltage high 4.5 Vdc black surface Voltage low 1.0 Vdc white surface Voltage low (d=6,35 mm [0.250 in]) 1.1 Vdc 50 % reflective surface Output short circuit (sourcing) Vo = 0 V 2 16 ma Output short circuit (sinking) Vo = 5 V 20 60 ma ABSOLUTE MAXIMUM RATINGS Operating temperature range -40 ºC to 85 ºC [-40 ºF to 185 ºF] ELECTRICAL CONNECTIONS Vcc 5 Vdc Ground Output open collector SCHEMATIC 7 4 1 NO CONNECTION Vcc +5 V GND VCSEL DET 3 OUTPUT 2 www.honeywell.com/sensing

Infrared Products MOUNTING DIMENSIONS (For reference only mm/[in].) R 1,27 [0.05] 10,16 [0.40] 5,08 [0.20] 3,81 [0.15] 13,46 [0.53] 13,46 [0.53] 7 NC 4 Vcc 3 Vo 1 GND 24,89 [0.98] 27,18 [1.07] 13,21 [0.52] 6,35 [0.25] 13,97 [0.55] 2,54 [0.10] 9,14 [0.36] 5,08 [0.20] 8,89 [0.35] 13,97 [0.55] 27,94 [1.10] 10,16 [0.40] R 1,52 [0.06] Honeywell Sensing and Control 3

ORDER GUIDE Catalog Listing HOA6480-001 HOA6480-002 Description Barcode sensor with pins Barcode sensor with 609,6 mm [24.0 in ] wires WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 11 West Spring Street Freeport, Illinois 61032 www.honeywell.com/sensing 006472-1-EN IL50 GLO Printed in USA June 2005 2005 Honeywell International Inc.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: HOA6480-001