WHAT LURKS BELOW THE WATERS OF YOUR CENTRAL HEATING SYSTEM?

Similar documents
Common central heating problems

LST Plus Vertical. Plus Vertical 3 models. Lengths: 560mm, 660mm & 760mm. Outputs: 1335 to 1862 watts, 4555 to 6353 Btu/hr

Maintaining optimum system performance

Technical Checklist - Plumbing and Heating Fittings - UK Sizes

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

Boiler Additives And Filtration

Greenstar System Filter

The NEW advanced electrolytic scale inhibitor with intelligent LED monitoring technology from Sentinel

Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump.

Please take time to carefully read through these guidelines before using your Kamco pump.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

INSTALLATION & TECHNICAL MANUAL

LST STANDARD. Safety Series

Trials of Vexo inhibitor in domestic central. heating systems

Installation Instructions Flute Tap Range

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

LST i PLUS. Safety Series

Installation Instructions and User Guide. Heritage Fixed Riser Kit. Models Covered: STC03 (Chrome) STA03 (Gold)

water solar heating SOLAR

Risk Assessment and Control Measures for Household Hot Water Systems

METRO BASIN MONO MIXER CHR

SEALED THERMAL STORE

Carry Out Maintenance Procedures

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

HEAVY DUTY BRASS SHOWER PUMPS

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

CalMag Heating Pack Installation Instructions

Installation and Operating Manual for the EcoStar 500 Oil Condensing Floor Standing Range Output Range kw

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

HYDROPATH Technology The home of

METRO BATH FILLER MOUNTED CHR

IDL/ De Longhi Appliances via Seitz, Treviso Italia

Scale Stopper Plus Installation & Start-Up Guide

PERFORMANCE SHOWER PRODUCTS

ADVANCE ECB ELECTRIC COMBINATION BOILER

imagine a world of soft water

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Technical Bulletin Developed with Glow-worm

AQUABION Galvanic water treatment for limescale & corrosion Frequently Asked Questions (FAQ s) June 2018

INSTALLATION INSTRUCTIONS

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Description of the property and water systems:

MBSY110P+ BASIN MONOBLOC WITH CLICK CLACK WASTE

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Desiccants & Driers. By Norm Christopherson

Eliminator TotalGuard Installation Manual

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

How to keep your home safe and dry. Start here

RECOMMENDATIONS FOR INSTALLATION

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

Installation and servicing instructions

X A M G3/4 G3/

Commercial product range

HW3 Handwash Installation and Operating Instructions

CONCEALED THERMOSTATIC SHOWER MIXER VALVE installation & aftercare instruction

TREVI BLEND SINGLE LEVER SHOWER VALVES. INSTALLER After installation pass to user for future reference

Beautifully Traditional

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Jetflush 4 Instruction Manual

IMPORTANT SAFEGUARDS Ensure that your mains supply voltage is the same as that marked on the underside of your kettle.

INSTALLATION & TECHNICAL MANUAL

Alpha FlowSmart 25 and 50

User and Installation Instructions. Wall Mounted Water Boiler WMB3F/B and WMB3F/W IS435 ECN3461

Go Greener, with Gas.

OPERATION & MAINTENANCE INSTRUCTIONS

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

Dene Bath Shower Mixer

Blueberry Kitchen Sink Tap

Legionnaires Disease Risk Assessment

Cinnamon Kitchen Sink Tap

Domestic Green Deal Advice Training

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

COX714DC. Dual Control Sensor Kitchen Mixer chrome

Bath Shower Mixer

Target Monobloc Kitchen Mixer Chrome

Winchester Heated Towel Rail. Fitting Instructions

Cast Iron Radiators. General Information 2. Block make up 6.

Monza Easyfit Kitchen Sink Mixer

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Installation Instructions & Maintenance Guide 6 Refit Nuts (19) and tighten.

Energy Ambassadors Guide

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

Male elbow, copper x BSP taper male thread

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

PULSACOIL A CLASS USER GUIDE. TEL:

K&W Permanent Metallic Block Seal

Samsung EHS Heat Pump Test

25 per cent of energy used in the home is used to heat water.

CROMO manual mixer shower

X62 Tap Range. Please keep these instructions for future reference

CPC-150-ABIAB. Important Installation Notes.

Transcription:

WHAT LURKS BELOW THE WATERS OF YOUR CENTRAL HEATING SYSTEM? The Fernox Guide to typical central heating and hot water problems and their solutions.

CORROSION IN PIPES. LIMESCALE BUILD-UP IN BOILERS. BLACK SLUDGE IN RADIATORS. BACTERIA IN WATER TANKS. LEAKS IN THE SYSTEM. DRUM SOLOS IN BOILERS. Without proper treatment, as soon as water enters a central heating or hot and cold water system, corrosion can occur. And because many signs of trouble go unnoticed (let s face it, no one is that interested in radiators, pipes and valves until they go wrong!), the upheaval and cost in restoring a damaged system can be high. We ve dealt with the problems your system may encounter for nearly 40 years. In the process, we ve become the UK s leading manufacturer of cleansing, restoration and protection products for domestic water systems. PREVENTION IS CHEAPER THAN CURE WITH FERNOX. WE CAN T EMPHASISE TOO STRONGLY THAT ALL THE PROBLEMS WE OUTLINE IN THIS LEAFLET CAN BE AVOIDED BY CLEANSING AND PROTECTING YOUR SYSTEM FROM THE START. BECAUSE, WITHOUT ANY CORROSIVE DEBRIS, THE SYSTEM IS LIKELY TO GIVE YOU MANY YEARS OF COST-EFFECTIVE, EFFICIENT PERFORMANCE.

Central Heating Systems: The Problem Areas. Radiator Cold Spots. Typically caused by the build up of black metal oxide (rust) in the central lower parts of radiators. This corrosive debris can increase your fuel costs between 10 and 35% in five years, whilst reducing the efficiency of the whole system. Cleansing with Fernox Restorer followed by the addition of Fernox Protector will restore system efficiency and prevent corrosion. Radiator Air Pockets. Caused by hydrogen gas build-up as a by-product of electrolytic corrosion (water and metals chemically reacting) in an untreated system. The solution is to cleanse the system with Fernox Restorer and protect with Fernox Protector. Radiator Failure. Existing system radiators should be cleansed with Fernox Restorer, then flushed and treated with Fernox Protector to ensure efficiency. New system radiators must be pre-commission (i.e. before first use) cleansed and protected. Without any protection, brand new radiators can fail completely within a few years (and cost a small fortune to replace, along with the boiler). Boiler Failure. Older, improperly protected boilers suffer boiler noise (drumming, knocking and thumping) due to excessive limescale and black sludge build-up. In the case of failure, the insulating effects of scale and sludge effectively restrict the heat exchanger in the boiler to the point when it overheats and fractures (expensive!). The entire system should be cleansed with Fernox Restorer and protected with Fernox Protector. Pump Seizure & Failure. The abrasive qualities of corrosion debris, hard limescale and bits of solder, flux and copper swarf in the system gradually wear down or cause pumps and actuators (they control the direction of flow) to stick, seize and fail. The whole system should be cleansed and protected. Leaking Valves & Pipes. Usually caused by loose gland nuts, failed O rings or failed packing around the stem of the valve. Valves should be replaced or the joints remade using Fernox Jointing Pastes and Solder. Leaking pipes can be a nightmare to detect especially if they are not visible or accessible see later. Pre-commission cleansing with Fernox Restorer followed by the addition of Fernox Protector will ensure years of effective performance from your central heating system. 3 4 5

Fernox products. Designed to be more efficient, more effective, more reliable. The Fernox Restorer Range. Restoring internal order. neutral universal cleansers for pre-commissioning new systems in accordance with BS7593:1992 removes sludge and scale and restores heating efficiency in existing systems suitable for use with all known makes of power flushing machine non-acid neutral formulations, COSHH-rated zero (0) easy to use the system can run during application the Superconcentrate cartridge injects directly into the radiator in minutes compatible with all metals and materials commonly used in heating systems Dealing with Micro and Macro Leaks: Some airtight, watertight solutions. A leaking radiator valve is usually easily detected; either by damp patches or the telltale green oxidized copper pipework below a valve. Restoration work should be carried out using Fernox LS-X jointing compound. Pin hole leaks are caused by oxidations (and therefore corrosion) of metal at points of natural stress, i.e. joins or bends. To stop small leaks and weeps, simply add Fernox Leak Sealer LS-I to the system via the header tank or other suitable point of application using a Fernox Injector. Alternatively, Fernox Superconcentrate Leak Sealer can be injected directly into a radiator. The Fernox Protector Range. Protecting the asset. provides long-term protection against corrosion of all metals, including aluminium prevents build up of black sludge effective scale reducer prevents pumps and actuators sticking prevents hydrogen gas build-up saves on fuel bills through improved efficiency the Superconcentrate cartridge injects directly into the radiator in minutes Protector Alphi-11 is a combined antifreeze and inhibitor compatible with all metals and materials commonly used in heating systems Soldered joints, because they shrink unevenly during setting, can become porous. Minor pores can become active months or years after installation and are extremely difficult to locate. Cleansing the joints with wet and dry emery paper, followed by a smear of Fernox LS-X External Leak Sealer will prove effective.

Hot and Cold Running Water: What stops it? In a word, limescale. The calcium and other minerals in hard water react to form hard deposits of scale. These in turn build up into deposits that restrict water flow and your boiler s efficiency. They re equally effective in fouling up showerheads, taps, kettles and immersion tanks. Three Ways to Stop Scale in its Tracks. 1. The Fernox Electronic Water Conditioner: Built-in Prevention I. The Fernox Electronic Water Conditioner uses a microprocessor to magnetise calcium particles so that they cling to themselves rather than metal surfaces. As a result, the calcium remains in suspension and runs through the system without building up to form limescale. To fit, simply follow the instructions. No plumbing work is necessary, nor are the services of a professional plumber. 2. Fernox Quantomat: Built-in Prevention II. This in-line scale reducer is connected to the mains in horizontal or vertical pipework. It prevents the build up of limescale, and saves on future bills and maintenance. Each Fernox Quantophos H refill sachet lasts up to six months. Some knowledge of plumbing is required and full instructions are included. 3. Fernox Superconcentrate Limescale Preventer: Hands-on Prevention. Fast, effective scale reducer and preventer. Simply add one 450 g sachet to the cold water tank, and see its effects working for months. The product is completely safe to use. Bacteria in Water: Worth a closer look. Water tanks in lofts often have unwelcome visitors: birds, squirrels, mice, insects and wasps are some of the usual suspects, both dead and alive! To ensure that health risks such as Legionella and E.coli bacteria are avoided, the UK Health and Safety Executive recommend that water systems should be cleaned and chlorinated once a year. Fernox Sterox is provided in a complete kit to chlorinate a hot and cold domestic water system. Full instructions to this simple task are included in the pack. Emergency Repairs: Well worth the effort. Lady Luck usually determines a householder s fate when it comes to leaks, breakdowns and stoppages usually on a Friday afternoon, or the start of a bank holiday! So it makes sense to have a few sensible products to keep you ticking over until a long-term professional repair can be done. If your boiler suddenly starts sounding like a military parade, Fernox Boiler Noise Silencer will reduce the rattle and hum until it is cleansed and protected. Fernox Leak Fix is ideal for temporary repairs to valves and pipework, as is Fernox Fix-It (which you can apply to any surface). Fernox Leak Tester Spray is an effective gas leak detector that uses a pump action spray to reveal the trouble spot. 4. Fernox DS-3 Limescale Remover: Fast and Effective. To remove scale, Fernox DS-3 Limescale Remover works effectively in kettles, showerheads and hot water cylinders. A concentration of 5-10% by volume is recommended. A colour change from yellow, through green, to blue indicates when the descaling power is exhausted.

YOU RE CLOSE TO THE ANSWERS WITH FERNOX. We offer a 24-hour help line seven days a week. Call 0870 870 0362 for information and advice on any of our products. You can be sure of a professional answer. Cookson Electronics, Forsyth Road, Sheerwater, Woking, Surrey, GU21 5RZ Sales Tel: 0870 601 5000, Sales Fax: 0870 601 5005, Technical: 0870 870 0362 Email: sales@fernox.com Website: www.fernox.com