The Main Heating Range Guide. The Main Heating range of affordable combi, system and heat only boilers, cylinders and water heaters.

Similar documents
Duo-tec combi, Megaflo system and Solo heat only boilers. Range guide

Baxi 600, 400 & 200 boilers. Range guide

The Baxi HE System Boiler Range/Heat Only Range and Baxi GA System/Combi Boiler Range

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

INDEPENDENT COMBINATION & SYSTEM BOILERS.

A homeowner s guide to the Baxi Neta-tec Combi

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

DOMESTIC BOILER RANGE & ACCESSORIES.

Introduction. Our boilers are among the most efficient available, designed to be easy to install, reliable and economical.

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

DOMESTIC BOILER RANGE & ACCESSORIES FROM IDEAL BOILERS.

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Compact HRE Boiler Range. The smart choice for heating and hot water

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Sirius FS. Working towards a cleaner future

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

NEW BUILD YOUR COMPLETE SOLUTION.

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Unvented Water Heating. Zircon

The Ideal Logic. Combination, Heat Only and System Boilers. Heating Solutions.

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

Combined electric boiler and domestic hot water store

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

Unvented water heating

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

Sirius WH. Working towards a cleaner future

thermocompact High performance system boiler range

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Wall Hung Condensing Boilers. Working towards a cleaner future. heating specialists

UNVENTED STAINLESS STEEL CYLINDERS

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

turbomax plus High performance combination boiler range

Hotflo. Unvented point of use hot water

The iqe Boiler Range. Combination and System T Boilers.

Our Boiler Family Our Boiler Family

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

InTec 2 X HIGH EFFICIENCY BOILERS LOW CARBON SOLUTIONS

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Multipoint Technical Data

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

Amptec. Electric flow boiler

WALL-HUNG COMBINATION

Compact HE. High efficiency combi boiler. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

ecotec plus New high efficiency condensing combination and system boiler ranges

Installation and Service Manual. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Cistern-fed water heating

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Solar thermal domestic hot water system

EcoBlue Combi Installation and Service Manual. Gas Fired Wall Mounted Condensing Combination Boiler. Model Range (09/14)

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

Installation and Service Manual. Titanium Combi Condensing Combination Boiler

Installation and Service Manual Combi. Condensing Combination Boiler

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Neta-tec Plus Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Combi Eco Range. Installation & Service Instructions

Multipoint. Unvented point of use hot water

Instructions for Use Installation and Servicing

aquaplus High performance combination boiler with integrated power store

Platinum Combi HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

Easicom. Quality, reliability, flexibility

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Installation and Service Manual. Promax Combi Condensing Combination Boiler

Installation & Service Instructions. Heatmax Combi HE Range. Condensing Combination Boiler

Duo-tec 2 Combi GA Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Installation and Service Manual. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

SEDBUK & HARP. the complete range of oil and gas fired condensing boilers. Warmflow Boilers HIGH EFFICIENCY

System Eco Elite Range. Installation & Service Instructions

Product Guide Gas-fired and solar thermal. heating and hot water solutions NEW. Greenstar Comfort controls

Unvented water heating

Performa 24 Eco HE. Installation & Service Instructions. Condensing Combination Boiler

Combi Eco Elite Range. User s Guide and Important Warranty Information

WALL-HUNG COMBINATION

Installation and Service Manual. Promax SL Condensing Central Heating Boiler

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Easicom 2. Quality, Reliability, Flexibility

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

THE GREAT BRITISH BOILER. Visit Call Get advice, latest prices and help on choosing the right boiler for you.

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

Stored Water District Heating Interface Units. Heat Interface Units

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Installation and Service Manual. Gold Heat Condensing Central Heating Boiler

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Platinum Combi HE A Range. Installation & Servicing Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

Installation & Service Instructions. Promax SL Range. Supplied by HeatingSpares247.com. Condensing Central Heating Boiler.

Water Heating Systems

Installation & Service Instructions. Gold FSB 30 HE. Floor Standing Condensing Boiler. You can rely on

MEGAFLO HE Iss 1

Alpha CD13R,18R and 24R

Transcription:

The Main Heating Range Guide The Main Heating range of affordable combi, system and heat only boilers, cylinders and water heaters. MADE IN BRITAIN i

Contents Main Eco Elite Combi Page 4 High efficiency Main Heating Combi boiler, featuring tried and tested technology. Main Eco Elite System Page 6 With the highest energy efficiency rating possible, the Main Heating Eco Elite System satisfies all hot water and heating requirements. Main Heat Page 8 This heat only boiler has the highest possible efficiency rating and comes in five outputs to suit any job. Technical specifications Page 10 Main unvented cylinder Page 12 Fulfils the hot water requirements of a range of domestic properties. Available as a direct and indirect model. Main solar unvented hot water cylinder Page 16 Fulfils the hot water requirements of a range of domestic properties. Compatible with a range of solar applications. Available as a direct and indirect model. Main water heater Page 20 Two modern, sleek models ideal for properties with a high demand for hot water. Flue options Page 22 Flue positioning and controls Page 24 A clear and simple illustrated guide to the flue systems and accessories required for the Main range. Works loyalty scheme Page 26 Main product support and training Page 27 Main offers a comprehensive aftersales service, expert technical advice and a range of training courses. 2

At Main, we only offer products and services that are straightforward, effective, efficient and don t break the bank. That means a wide range of reliable, easy-to-install, low maintenance boilers, cylinders and water heaters as well as a range of heating controls that save your customers even more money. On top of all that, Main training and support services are there to offer help when you want it. It s everything you need. It s JOB DONE. Our range Main has a wide range of combi, system and heat only boilers in a range of outputs to suit every job. So whether you re replacing an old boiler or installing a new system, we have everything you need to get the job done. Of course, we don t just offer boilers and accessories, we also have a range of unvented hot water cylinders and water heaters to complement them. You ll find all the details you need on all our products in this easy to understand brochure including technical specifications and flue options. Our service To make it easier for you to get the job done, we offer FREE training courses and technical support, so you ll always have the very latest Main product knowledge. And because our dedicated training centres are spread across the UK, you ll always be within easy reach, wherever you are. See page 27 for details. Although our products are easy to install and simple to maintain, sometimes you just need a bit of help and advice. That s why we also have Baxi Customer Support our service division with a dedicated service centre and field engineers. You can reach them on 0344 871 1545 and there s more about them on page 27. Our heritage We ve been designing and building boilers in the UK for more than 75 years, working to the highest standards and ensuring the highest quality. It s given us a proud reputation for excellence in our industry a reputation that s strengthened with each outstandingly reliable boiler, cylinder or water heater we develop. It all means that when you install Main, you install a product you can depend on to get the job done. 3

MAIN ECO ELITE COMBI Automatic Air Vent Overheat Thermostat Sensor Burner Mixing Chamber Cast Aluminium/ Silicon Alloy Heat Exchanger Flue Combustion Checking Points Ignition and Flame Sensing Electrode Air Inlet Silencer Easy installation Like all our boilers, the Eco Elite Combi range is easy to install. A free one-piece pre-plumbing jig is included as standard, helping you get the pipework in the right place, first time. Electrical connections are housed separately to the PCB, making the job quick and easy to finish. Clock and filling loop included in the box as standard. Fan Diverter Valve Water Pressure Sensor Condensate Drain Electrical Power Terminal Expansion Vessel Pump Gas Valve High efficiency All Eco Elite Combi boilers are ErP compliant and have low NOx emissions. That s better for the planet and better for your customers. Low maintenance Built entirely in the UK, using high quality and well finished components. Layout of components allows for straightforward and speedy servicing and repairs. If something does go wrong, though, you can rest assured that our three year parts and labour warranty is there as back up. Dimensions and minimum clearances 5mm 450mm 5mm 175mm min* 780mm 200mm Pressure Gauge 5mm in operation 450mm for servicing *300mm min if using 80/125mm flueing system 345mm Terms and conditions apply, visit mainheating.co.uk for more information. For specifications please see page 10 and for flue options see page 22. 4

XL Boiler shown with flap down for illustration purposes. 5

MAIN ECO ELITE SYSTEM Automatic Air Vent Overheat Thermostat Sensor Burner Mixing Chamber Cast Aluminium/ Silicon Alloy Heat Exchanger Flue Combustion Checking Points Ignition and Flame Sensing Electrode Air Inlet Silencer Easy installation Like all our boilers, the Eco Elite System range is easy to install. A free one-piece pre-plumbing jig is included as standard, helping you get the pipework in the right place, first time. Electrical connections are housed separately to the PCB, making the job quick and easy to finish. High efficiency All Eco Elite System boilers are ErP compliant and have low NOx emissions. That s better for the planet and better for your customers. Fan Water Pressure Sensor Condensate Drain Electrical Power Terminal Dimensions and minimum clearances Expansion Vessel Pump Gas Valve Pressure Gauge Low maintenance Built entirely in the UK, using high quality and well finished components. 5mm 450mm 5mm 175mm min* 5mm in operation 450mm for servicing Layout of components allows for straightforward and speedy servicing and repairs. If something does go wrong, though, you can rest assured that our three year parts and labour warranty is there as back up. 780mm 200mm *300mm min if using 80/125mm flueing system 345mm Terms and conditions apply, visit mainheating.co.uk for more information. For specifications please see page 10 and for flue options see page 22. 6

7

MAIN HEAT Easy installation No pump overrun with three wire connection, saving time, no extra cables required. It s low in weight, compact and has minimal installation clearances, and can fit in a standard kitchen cupboard. Heat Exchanger Return Pipe Connection Flow Switch Flow Pipe Connection Air Pressure Switch Wiring Terminal High efficiency All Main Heat Only boilers are ErP compliant and have low NOx emissions. That s better for the planet and better for your customers. Low maintenance Built entirely in the UK, using high quality and well finished components. Burner Airbox Fan Protection Thermostat Condensate Trap Gas Valve (behind) Fan Assembly PCB Housing Layout of components allows for straightforward and speedy servicing and repairs. If something does go wrong, though, you can rest assured that our three year parts and labour warranty is there as back up. Dimensions and minimum clearances 5mm min 390mm 5mm min 200mm min 5mm min in operation 500mm for servicing 600mm 50mm min 280mm Terms and conditions apply, visit mainheating.co.uk for more information. For specifications please see page 11 and for flue options see page 23. 8

Condensation pipe not shown. 9

ECO ELITE SPECIFICATIONS Main Eco Elite Combi/System Units Main Eco Elite 25 Combi Main Eco Elite 30 Combi Main Eco Elite 24 System Main Eco Elite 28 System Sales code (boiler only) 7219409 7219410 7219411 7219412 Controls Concealed user controls 3 3 3 3 On/off switch with reset 3 3 3 3 User adjustable DHW temperature 3 3 3 3 User adjustable CH temperature 3 3 3 3 LED temp/status/fault diagnosis display 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs 2 digits/3 LEDs Integral 24 hour electro-mechanical timer Standard Standard N/A N/A Integral 7 day electronic timer Optional Optional N/A N/A Gas Gas supply connection mm 22 22 22 22 Natural gas 3 3 3 3 LPG (propane) N/A N/A N/A N/A Nominal inlet supply pressure NG mbar 20 20 20 20 Maximum gas rate m 3 /hr 2.76 3.17 2.76 3.10 Heat Input Central Heating (CH) kw Max Gross (QnHs) 28.92 32.54 28.92 32.54 kw Min Gross (QnHs) 8.68 9.77 8.68 9.77 Heat Output CH non-condensing kw Max (Pn) 25.94 28.63 25.94 28.63 kw min (Pn) 7.61 8.56 7.61 8.56 Heat Output CH condensing kw max (Pnc) 26.95 30.20 26.95 30.20 kw min (Pnc) 8.37 9.42 8.37 9.42 Heat Input Domestic Hot Water kw Max Gross (QnwHs) 28.92 33.30 N/A N/A Heat Output Domestic Hot Water kw Max (Pn) 24.88 30.00 N/A N/A Maximum domestic hot water flow rate l/min @ 35 C rise 10.2 12.3 N/A N/A SAP 2009 Annual Efficiency (PCDB/SEDBUK) % 89.00 88.70 89.10 88.80 NOx class 5 5 5 5 ErP product information NOx mg/kwh 25 30 25 30 Sound Power Level, Indoors LWA db 50 50 48 50 Space Heating Efficiency Class A A A A Water Heating Declared Load Profile XL XL N/A N/A Water Heating Efficiency Class A A N/A N/A Electrical Electrical supply Volts/Hz 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz Permanent live required Power consumption Watts 105 105 105 105 External fuse rating Amps Amps 3 3 3 3 Internal fuse rating Amps F2L F2L F2L F2L Ingress protection rating IPX 4D IPX 4D IPX 4D IPX 4D (without electro-mechanical timer fitted) 24 hour pump exercise Pump overrun Integral boiler only frost thermostat Mechanical and hydraulic Compartment ventilation requirement None None None None Pre-plumbing/wall mounting jig Central heating flow and return connections mm 22 22 22 22 Condensate discharge connection m mm 21.5 21.5 21.5 21.5 Integral automatic bypass Min domestic hot water flow rate l/min 2 2 N/A N/A Min domestic hot water operating pressure bar 0.15 0.15 N/A N/A Maximum DHW system pressure bar 8 8 N/A N/A Safety discharge pressure bar 3 3 3 3 Integral expansion vessel capacity litres 8 10 8 10 Max capacity of central heating system litres 125 125 125 125 Filling loop included CH system inhibitor required Yes Yes Yes Yes Concentric flue system (60/100 & 80/125) Standard telescopic horizontal flue kit length mm 315-500 315-500 315-500 315-500 Max equiv length horizontal/vertical (60/100mm) m 10 10 10 10 Max equiv length horizontal/vertical (80/125mm) m 20 20 20 20 Equivalent length per 135º bend m 0.5 0.5 0.5 0.5 Equivalent length per 93º bend m 1 1 1 1 Twin pipe flue system Diameters mm 80/80 80/80 80/80 80/80 Max equiv length horizontal/vertical (parallel pipes) m 15/15 15/15 15/15 15/15 Equivalent length per 135 bend m 0.25 0.25 0.25 0.25 Equivalent length per 91.5 Bend m 0.5 0.5 0.5 0.5 Weights Max installation lift weight kg 45 45 42.2 42.2 Gross packaged boiler weight kg 51 51 48.5 48.5 10

HEAT SPECIFICATIONS Main Heat Units Main 12 Heat Main 15 Heat Main 18 Heat Main 24 Heat Sales code (boiler only) 7219393 7219394 7219395 7219396 Controls Concealed user controls Yes Yes Yes Yes LED operating status display Yes Yes Yes Yes Gas Gas (Natural Gas/LPG) NG NG NG NG Inlet supply pressure mbar 20 20 20 20 Maximum gas rate m³/hr 1.34 1.64 1.94 2.31 Heat input central heating (CH) kw max gross (QnHs) 13.34 16.88 20.18 24.5 kw min gross (QnHs) 10.2 10.2 10.2 10.2 Heat output CH non-condensing kw max (Pn) 11.82 15.24 17.81 22 kw min (Pn) 9.14 9.14 9.14 9.14 Heat output CH condensing kw max (Pnc) 12.81 16.49 19.27 23.8 SAP 2009 Annual efficiency (PCDB/SEDUK) % 88.7 89.4 88.7 88.8 NOx class 5 5 5 5 ErP product information NOx mg/kwh 20 20 20 19 Sound power level, Indoors Lwa db 38 46 49 52 Space heating efficiency class A A A A Electrical Electrical supply Volts/Hz 230/50 230/50 230/50 230/50 Permanent live required No No No No Power consumption Watts 80 80 80 80 External fuse rating Amps 3 3 3 3 Boiler IPX rating (electrical protection) IPX2 IPX2 IPX2 IPX2 Integral boiler only frost thermostat No No No No Mechanical Gas supply connection mm 22 22 22 22 Central heating connections mm 22 22 22 22 Condensate drain connection mm 21.5 21.5 21.5 21.5 Upward piping route mm Yes Yes Yes Yes Hydraulic Safety discharge pressure bar 3 3 3 3 Compartment ventilation required No No No No Concentric flue systems Concentric flue diameter mm 70/110 70/110 70/110 70/110 Concentric standard flue length mm 800 800 800 800 Max. equivalent vertical length (Ø 70/110) m 4 4 4 4 Max. equivalent horizintal length (Ø 70/110) m 4 4 4 4 Twin flue system Twin pipe flue diameter mm 80/80 80/80 80/80 80/80 Max. equivalent vertical length m 75 75 75 75 Max. equivalent horizontal length m 75 75 75 75 Plume displacement kit Compatibility Weight Gross packaged boiler weight kg 36.2 36.2 36.2 36.2 Max installation lift weight kg 26.0 26.0 26.0 26.0 11

MAIN UNVENTED CYLINDER Easy installation Front access to controls and connections for easy installation. Designed to work with the Main Heat and Main Eco Elite System range of boilers providing you with the complete solution to your project, with no compatibility issues. PERFECT FOR YOUR CUSTOMERS: Replacing existing cylinders Suitable for low mains pressure areas Ideal for homes with more than one bathroom Indirect and direct models available Energy efficient Coil-in-coil heat exchanger ensures rapid heat recovery while promoting energy efficiency. All cylinders are manufactured in the UK where we inject 50mm of polyurethane foam between the cylinder and the casing to increase insulation and save energy. Compatible with: Main Eco Elite System Low maintenance High grade stainless steel inner cylinder prolongs product life and ensures low maintenance. The Incoloy 800 alloy sheathed elements are designed to resist corrosion, a common problem with other unvented cylinders. Main Heat Our indirect heating coil is fitted with an electric immersion heater as back up, leaving you and your customers confident they will have hot water whenever they need it. We re so confident of the quality of our unvented cylinder, we offer a one year parts and labour warranty, and will guarantee the stainless steel shell for a further 24 years. Terms and conditions apply, visit mainheating.co.uk for more information. For specifications please see pages 14-15. See page 27 for more details. 12

B 13

SPECIFICATIONS Element Long-life removable Incoloy 800 sheathed element, rated 3.0kW @ 240V. Direct models are fitted with two 3.0kW immersion heaters as standard. Outer casing A combination of resilient thermoplastic mouldings and plastic coated corrosion proofed steel sheet. Thermal insulation CFC/HCFC free (ODP ZERO) fire retardant expanded polyurethane. 50mm thickness. Inner container High grade stainless steel, pressure tested to 15 bar. Primary coil 22mm diameter stainless steel. Coil in coil design for improved performance. Thermostat Element thermostat adjustable from 10 C to 70 C. Safety features Temperature and pressure relief valve, factory set to operate at 10 bar and 90 C. High limit thermostat, factory set at 80 C. Direct models Manually re settable cut-out on heating element operates at 80 C. Indirect models Must be wired in series with the supplied two-port motorised valve to provide primary over temperature protection. Anode None required. Approvals KIWA approved for water regulations and building regulation G3. Manufactured in the UK in a BS EN ISO 9001:2008 registered factory. CE marked for compliance with LVD, EMC and pressure equipment directives. Installation Main unvented cylinders must be installed by a competent installer in accordance with local regulations: England and Wales Building regulation G3. Scotland Technical standards P3. N. Ireland Building regulation P5. Fixing Feet on bottom moulding for floor mounting. Plumbing connections Inlet/Outlet, 22mm compression fittings / ¾ BSP parallel thread. Primary coil 22mm compression fittings / ¾ BSP parallel thread. Temperature and pressure relief valve 15mm compression outlet. Cold water control Integrated cold water control set comprising pressure reducing valve and strainer factory set at 3.5 bar, expansion relief valve factory set at 6 bar and check valve. 22mm compression fittings. Mains pressure Min 1.5 bar, Max 16 bar. A 2-port motorised valve is supplied with indirect models. Flow rates Up to 55 litres per minute @ 6 bar pressure. Operating pressure 3.5 bar. Expansion relief valve pressure 6.0 bar. Operating temperature Recommended 60 C. Adjustable 10-70 C. Water expansion Remote expansion vessel 12 litre vessel supplied with 120 and 150 litre models. 18 litre vessel supplied with 170 and 210 litre models. 24 litre vessel supplied with 250 and 300 litre models. Minimum water supply requirements Recommended minimum supply pressure 1.5 bar/20 l/min flow rate. If there are any doubts about water supply pressure or flow rates, please contact our Specification Advice Team to discuss on 0845 026 4620. Secondary circulation Via 22 x 22 x 15mm swept tee, which should be fitted to the inlet pipework. Secondary Circulation is not recommended for direct units being used with off-peak electricity tariffs. Pressure testing Units are tested to 15 bar. Tundish 15mm compression inlet and 22mm compression outlet. Electrical Indirect models Controls should be wired to the boiler, programmer etc., in accordance with the control scheme being used. Direct models Connection is direct to terminals in the immersion heater which must be permanently connected to the supply through a double-pole lined isolating switch with a minimum breaking capacity of 13A. All electrical wiring must conform to the latest IEE Wiring Regulations. 14

Dimensions and performance HOT OUTLET T&P VALVE Ø 550 315 A PRIMARY FLOW PRIMARY RETURN COLD INLET 354 - indirect 306 - direct B 595 45 25 30 45 Nominal Capacity (litres) Direct Type Indirect Dimensions A (mm) Dimensions B (mm) kw Rating Coil Heat Up Time (mins) Recovery Times Heating Time Direct (mins) ErP Rating Product Code Standing Heat Loss (kw/h per 24hr) 120 931 616 121 C 720635901 120 931 616 12.5 27 23 29 B 5133561 150 1114 800 152 C 720636001 150 1114 800 12.5 38 24 37 C 5133562 170 1241 927 173 C 720636101 170 1241 927 16 33 25 35 C 5133563 210 1499 1184 215 C 720636201 210 1499 1184 16 41 29 43 C 5133564 250 1752 1437 260 D 720636301 250 1752 1379 18 40 30 43 D 5135327 300 2065 1751 315 D 720636401 300 2065 1694 19 47 35 49 D 5135328 1.47 1.7 1.92 2.3 2.22 2.52 Unvented cylinder specification enquiries Telephone: 0845 026 4620. 15

MAIN SOLAR THERMAL UNVENTED HOT WATER CYLINDER Energy efficient Unlike some other twin coil cylinders, our cylinders have a purpose designed solar heating coil at the base of the cylinder, ensuring maximum heat input and efficiency from the solar source. Easy installation Comes with all the benefits of the Main unvented cylinder plus a whole lot more. Designed specifically for solar applications to make sure it does the job perfectly. To make things simple, the Main solar cylinder is compatible with most solar thermal systems now available in the UK. The remote expansion vessel can be located in various places, to suit your installation requirements. PERFECT FOR YOUR CUSTOMERS: Provides low carbon domestic hot water Fast filling showers and baths Powerful hot water from your solar thermal water heating system Compatible with: Main Eco Elite System Low maintenance High grade stainless steel inner cylinder prolongs product life and ensures low maintenance. We re so confident of the quality of our unvented cylinder, we offer a one year parts and labour warranty, and will guarantee the stainless steel shell for a further 24 years. Main Heat *Savings vary depending on type of solar system used, location and usage patterns. See page 27 for more details. For specifications please see pages 18-19. 16

C 17

SPECIFICATIONS Siting the unit The Main solar cylinder must be installed vertically. Although location is not critical, the following points should be considered: The Main solar cylinder should be sited to ensure minimum dead leg distances, particularly to the point of most frequent use. Avoid siting where extreme cold temperatures will be experienced. All exposed pipework should be insulated. The discharge pipework from the safety valves must have minimum fall of 1:200 from the unit and terminate in a safe and visible position. Access to associated controls and immersion heaters must be available to provide for the servicing and maintenance of the system. Where these controls are installed against a wall a minimum distance of 250mm must be left. Ensure that the floor area for the Main solar cylinder is level and capable of permanently supporting the weight when full of water. Wherever possible the mains supply pipe should be 22mm. We suggest the minimum supply requirements should be 1.5 bar pressure and 20 litres per minute flow rate. The Main solar cylinder has an operating pressure of 3.5 bar which is controlled by the cold water combination valve assembly. The cold water combination valve assembly can be connected to a maximum mains pressure of 16 bar. Outlet/terminal fittings (taps, etc.) The Main solar cylinder can be used with most types of terminal fittings. All fittings, pipework and connections must have a rated pressure of at least 6 bar at 80 C. Operational summary Maximum mains pressure 16 bar. Operating pressure 3.5 bar. Expansion vessel charge pressure 3.5 bar. Expansion relief valve setting 6 bar. T&P relief valve setting 90 C/10 bar. Maximum primary circuit pressure. (Auxiliary coil, indirect only) 3 bar. Maximum primary circuit pressure 6 bar (Solar coil). Important note: THE MAIN SOLAR CYLINDER MUST BE INCORPORATED INTO A FULLY PUMPED SOLAR PRIMARY CIRCUIT. CONTROL OF THE SOLAR PRIMARY IS ACHIEVED BY THE USE OF EXTERNAL CONTROLS NOT SUPPLIED WITH THE UNIT. CONTROL MUST BE VIA A PURPOSE DESIGNED SOLAR HYDRAULIC STATION AND SOLAR DIFFERENTIAL TEMPERATURE CONTROLLER. Pipe fittings All pipe fittings are made via 22mm compression fittings directly to the unit. The fittings are threaded ¾ BSP male parallel should threaded pipe connections be required. Cold feed A 22mm cold water supply is recommended, however if a 15mm (½ ) supply exists which provides sufficient flow this may be used (although more flow noise may be experienced). A stopcock or servicing valve should be incorporated into the cold water supply to enable the Main solar cylinder and its associated controls to be isolated and serviced. Drain tap A suitable draining tap should be installed in the cold water supply to the Main solar cylinder unit between the expansion valve and the heater at as low a level as possible. It is recommended that the outlet point of the drain pipework be at least 1 metre below the level of the heater. Expansion vessel The expansion vessel is pre-charged at 3.5 bar and must be connected between the expansion valve and the Main solar cylinder. Secondary circulation The secondary return pipe should be in 15mm pipe and incorporate a check valve to prevent backflow. A suitable WRAS approved bronze circulation pump will be required. Outlet Hot water distribution pipework should be 22mm pipe with short runs of 15mm pipe to terminal fittings such as sinks and basins. Installation Connection to solar primary circuit The lower (solar) coil of the Main solar cylinder must be connected to a fully pumped solar primary circuit. The connections are suitable for 22mm copper pipe direct to the compression fittings provided. The connections are also threaded ¾ BSP male parallel should BSP be required. Plumbing connections Direct units require the following pipework connections. Cold water supply to and from inlet controls. Outlet to hot water draw off points. Discharge pipework from valve outlets to tundish. Connection to the auxiliary primary circuit (Auxiliary/ Indirect unit only). Primary connections are 22mm compression. However, ¾ BSP parallel threaded fittings can be fitted to the primary coil connections if required. Electrical supply Main solar units are fitted with 1x3kW immersion heater on indirect units and 2x3kW immersions on direct units as standard. The Main solar cylinder MUST be earthed. The circuit must be protected by a suitable fuse and double pole isolating switch with a contact separation of at least 3mm in both poles. 18

Dimensions and performance Ø 550 373 D 415 C A 595 45 25 30 45 HOT OUTLET T&P VALVE AUXILIARY FLOW AUXILIARY RETURN PRIMARY FLOW PRIMARY RETURN COLD INLET B Nominal capacity (litres) Indirect Dimensions (mm) Solar coil Auxiliary A B C D surface volume Surface area (litres) area (m 2 ) (m 2 ) Auxiliary coil Rating (kw) Heat up (mins) Recovery (mins) ErP Rating Product code 190 1401 1085 784 925 1.1 120 0.61 11.9 42 22 C 720634701 210 1499 1186 1012 1026 1.1 120 0.68 15.2 33 35 C 720634801 250 1752 1438 1143 1279 1.1 145 0.79 15.2 40 30 D 720634901 300 2065 1752 1440 1592 1.1 175 0.79 17.4 42 32 D 720635001 19

MAIN WATER HEATER PERFECT FOR YOUR CUSTOMERS: Provides hot water for businesses and small households with high demand It only heats the water needed, for greater efficiency Creates space no need for a storage cylinder Quality you can trust Main has an unrivalled reputation for offering reliable, safe, efficient and easy-to-use water heaters. Easy installation B B Installation is straightforward, thanks to the simple three pipe connections with isolation valves, pre-wired standard plug (FF) and flexible flueing options. Ideal in homes with high hot water demand, Main FF (Fan Flue) and Main BF (Balanced Flue) Water Heaters provide instant hot water without the need for a storage cylinder. If you need to locate the heater away from an external wall, the FF model is perfect. It has a four metre horizontal and vertical flue option making siting easy. Balanced flue model 420mm 285mm Fan flue model 388mm 220mm 100mm The BF option comes with a Piezo Spark Igniter, meaning no batteries or wiring are needed. Both models have clear temperature controls. 846mm 700mm Low maintenance The key to our success is the simplicity of our products. They do exactly what you need them to do and they do it reliably. That means you waste less time and money dealing with call backs and maintenance issues. Telescopic flue available in four length options to suit wall thickness from 100mm to 610mm: Sales Code Min. length 100mm (4 in.) 31/10321 Max. length 150mm (6 in.) Min. length 150mm (6 in.) 31/10322 Max. length 230mm (9 in.) Min. length 230mm (9 in.) 31/10323 Max. length 380mm (15 in.) Min. length 380mm (15 in.) 31/10324 Max. length 610mm (24 in.) The appliance may be mounted on a suitable existing terminal as above, provided the requirements of the building regulations are maintained. 20

SPECIFICATIONS Model Units Balanced Flue Model Fan Flue Model Model name Multipoint BF Multipoint FF Water heater code 7221083 7221081 Min service clearance above mm 30mm 120mm (Includes flue elbow) Min service clearance sides mm 5mm 10mm Min service clearance in front mm 600mm 600mm Min service clearance below mm 75mm 50mm Max DHW flow rate (Delta T @ 30 C max) l/min 10.8 l/min 11.7 l/min Max DHW flow rate (Delta T @ 35 C max) l/min 9.3 l/min 10 l/min Max DHW flow rate (Delta T @ 50 C max) l/min 6.5 l/min 7 l/min Min operating DHW pressure required bar 0.2 bar 0.3 bar Max DHW system pressure bar 12 bar 12 bar Minimum flow rate required l/min 2.5 l/min 2.5 l/min IP rating N/A IPX4D ErP Product Information NOx mg/kwh 161 184 Sound power level, Indoors Lwa 69 54 Water heating declared load profile XL XL Water heating efficiency class B B Gas Natural gas Yes Yes Heat input (net) kw 25.5 27 Heat output to water kw 23 23.8 Electrical Electrical connection V None 230 fused UK plug Mechanical and hydraulic Gas connection pipe size mm 15 15 Water connection pipe size mm 15 15 Flue systems Maximum equivalent length horizontal mm 610 4000 Maximum equivalent length vertical mm N/A 4000 Weight Installer lift weight kg 20 20 Concentric horizontal flues water heaters Concentric horizontal flue arrangement Key and OD dimension Multifit sales code Standard horizontal flue kit 400mm 430183 Horizontal flue kit (long) 680mm 430184 Flue extension 1000mm B4286 90 bend kit 31/19034 135 bend kit 31/19035 Telescopic flue elbow adaptor 430174 Vertical adaptor 238014 Concentric vertical flues water heaters Concentric vertical flue arrangement Key and OD dimension Multifit sales code Concentric vertical flue kit 238015 Flue extension 1000m B4286 90 bend kit 31/19034 135 bend kit 31/19035 Flat roof flashing kit 31/19040 Pitched roof flashing kit 31/19041 Please refer to page 22 for flue positioning guide. 21

FLUE SOLUTIONS Multifit flue kits now come with positive screw fixings for all connections and are available in a choice of lengths to reduce the need for onsite cutting. By popular demand we offer a choice of colours for the terminals to match existing rainwater systems. The options shown are only compatible with Main Heating Eco Elite Combi and System. Maximum recommended flue lengths Main Combi / System / Store A (60/100 Concentric) G (80/125 Concentric) N (80/80 Twin Pipe) Horizontal 10 20 15 Vertical 10 20 15 Main Heat B (70/110 Concentric) P (80/80 Twin Pipe) Horizontal 4 75 Vertical 4 75 Horizontal concentric flues Ø 60/100mm Multifit Flue Group A Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 1 Horizontal telescopic flue inc. low profile elbow and fixing screws White pipe/ 315mm 500mm 60/100mm 720599401 white terminal 2 Horizontal telescopic flue inc. low profile elbow and fixing screws White pipe/ 315mm 500mm 60/100mm 720598701 black terminal 3 Horizontal telescopic flue inc. Low profile elbow and fixing screws White pipe/ 315mm 500mm 60/100mm 720642701 brown terminal 4 Standard horizontal flue inc. low profile elbow and fixing screws* White pipe/ black 685mm 100mm 7222019 terminal 5 Horizontal telescopic in case rear flue inc. fixing screws White pipe/ 100mm 7210434 black terminal 6 Flue terminal deflector White 60mm 720644201 7 Flue terminal deflector Black 60mm 5111068 8 Flue terminal deflector Brown 60mm 720644301 9 1m flue extension inc. fixing screws White 1000mm 100mm 720648801 10 0.5m flue extension inc. fixing screws White 500mm 100mm 720643001 11 0.25m flue extension inc. fixing screws White 250mm 100mm 720643101 12 93 flue bend inc. fixing screws White 93 100mm 720648401 13 135 flue bend inc. fixing screws White 135 100mm 720648501 14 135 flue bend inc. fixing screws (pair) White 135 100mm 720647901 15 Offset adaptor elbow White EcoBlue Advance Combi and Ecoblue 32 System only 100mm 720635501 16 93 low profile boiler elbow White 93 100mm 720550801 17 Stainless steel terminal guard Ø 60/100 S/S Stainless steel 100mm 720627901 Plume displacement kits Ø 60/100mm Multifit Flue Group A Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 18 Plume displacement terminal kit inc. 1m extension and brackets White 60mm 720627001 19 Plume displacement kit extension and brackets White 1000mm 60mm 720643401 20 Plume displacement kit bend White 93 60mm 5121369 21 Plume displacement kit bend pair White 135 60mm 5121370 22 Plume displacement terminal kit inc. 1m extension and brackets Black 60mm 720622901 23 Plume displacement kit extension and brackets Black 1000mm 60mm 720643301 24 Plume displacement kit bend Black 93 60mm 720648701 25 Plume displacement kit bend pair Black 135 60mm 720648601 26 Plume displacement terminal kit inc. 1m extension and brackets White 100mm 7225717 27 Plume displacement terminal kit inc. 1m extension and brackets Black 100mm 7225716 28 Under balcony eaves flue kit White 135 60mm 7211039 29 Under balcony eaves flue kit Black 135 60mm 7211041 For information on reductions for the twin pipe flues please see the installation instructions. *Not compatible with items 16 and 20. **Compatible with 1. ***Compatible with 22. 22

Vertical concentric flues Ø 60/100mm Multifit Flue Group A Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 30 Vertical ridge flue terminal Brown 100mm 720647101 31 Vertical flue terminal Black 100mm 5118576 32 Roof cover plate 125mm 246143 9 1m flue extension inc. fixing screws White 1000mm 100mm 720648801 10 0.5m flue extension inc. fixing screws White 500mm 100mm 720643001 11 0.25m flue extension inc. fixing screws White 250mm 100mm 720643101 12 93 flue bend inc. fixing screws White 93 100mm 720648401 13 135 flue bend inc. fixing screws White 135 100mm 720648501 14 135 flue bend (pair) inc. fixing screws White 135 100mm 720647901 33 Pitched roof flashing 25 /50 125mm 5122151 34 Flat roof flashing 125mm 246144 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 (x2) 18 22 19 23 20 24 26 27 30 21 25 28 29 (x2) 31 32 33 34 23

Flue solutions Horizontal concentric flues Ø 80/125mm Multifit Flue Group G Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 35 Horizontal flue inc. boiler and terminal adaptors Black 125mm 5118580 36 1m flue extension White 1000mm 125mm 5118584 37 Flue bend White 91.5 125mm 5118588 38 Flue bend (pair) White 135 125mm 5118597 39 Pipe support bracket White 125mm flue pipes 125mm 5118610 Vertical concentric flues Ø 80/125mm Multifit Flue Group G Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 40 Vertical flue terminal Black 125mm 5111078 36 1m flue extension White 1000mm 125mm 5118584 37 Flue bend White 91.5 125mm 5118588 38 Flue bend (pair) White 135 125mm 5118597 32 Roof cover plate 125mm 246143 41 Flue vertical adaptor White 100/125mm 5111070 33 Pitched roof flashing 25 /55 125mm 5122151 35 Flat roof flashing 125mm 246144 39 Pipe support brackets White 125mm flue pipes 125mm 5118610 35 36 37 38 (x2) 39 40 41 42 43 (x2) 44 45 46 47 (x2) (x2) (x2) 48 49 50 51 24 The options shown are only compatible with Main Heating Eco Elite Combi and System.

Twin pipe flues 80/80mm Multifit Flue Group N Item Description (multifit) flue system Colour Specification Key and OD dimensions Sales code 40 Vertical flue terminal Black 125mm 5111078 42 Twin pipe extension (pair inc. Brackets) White 1000mm 80mm 5111087 43 Twin pipe flue bend (pair) White 90 80mm 5111072 44 Twin pipe flue bend (pair) White 135 80mm 5111086 30 Roof cover plate 125mm 246143 45 Twin pipe flue horizontal terminal kit (air and exhaust) Stainless steel 575mm 80mm 5120172 46 Twin pipe flue adaptor (boiler) White 80/80mm 720089801 47 Twin pipe support (pair) White 80mm 5111081 48 Twin to concentric adaptor 80/80-80/125 White 80/125mm 5111084 33 Pitched roof flashing 25 /50 125mm 5122151 34 Flat roof flashing 125mm 246144 49 Pitch roof flue terminal Black 25 /50 60mm 720576301 50 Pitched roof terminal adaptor kit White 60-80mm 5121792 51 Single flue terminal (air only) 80mm 5121791 Terminal position with minimum distance (mm) A 1 Directly below an opening, air brick, opening windows etc 300 B 1 Above an opening, air brick, opening window etc 300 C 1 Horizontally to an opening, air brick, opening window etc 300 D 2 Below gutters, soil pipes or drain pipes 25 E 2 Below eaves 25 F 2 Below balconies or car port roof 25 G 2 From a vertical drain pipe or soil pipe 25 H 2 From an internal or external corner 25 I Above ground, roof or balcony level 300 J From a surface or boundary line facing a terminal 600 K From a terminal facing a terminal (Horizontal flue) 1200 K From a terminal facing a terminal (Vertical flue) 600 L From an opening in a carport (e.g. door, window) into the dwelling 1200 M Vertically from a terminal on the same wall 1500 N Horizontally from a terminal on the same wall 300 R From adjacent wall to flue (vertical only) 300 S From an adjacent opening window (vertical only) 300 T Adjacent to windows or openings on pitched and flat roofs 600 U Below windows or openings on pitched roofs 2000 I R F L M I N J,K Likely flue positions requiring a flue terminal guard T G A I B U C I H D E S A F H A I J,K 1. In addition, the terminal should be no nearer than 150mm to an opening in the building fabric formed for the purpose of accommodating a built-in element such as a window frame. 2. Only ONE 25mm clearance is allowed per installation. If one of the dimensions D, E, F, G or H is 25mm then the remainder MUST be as B.S.5440-1. Plume displacement kit IMPORTANT: If fitting a Plume Displacement Flue Kit, the air inlet must be a minimum of 150mm from any opening windows or doors Terminal assembly 300mm min* Air inlet Opening window or door Top view rear flue NOTE: The distance from a fanned draught appliance terminal installed parallel to a boundary may not be less than 300mm in accordance with the diagram. 150mm min. Property boundary line *This can be reduced to 25mm by using item 6/7/8 flue deflector. 25

HEAT ONLY FLUE SOLUTIONS Maximum permissible flue lengths, refer to the instruction manuals Horizontal concentric flues 70/110mm Item description (MULTIFIT) flue system B Specification Key and OD dimensions Multifit sales code Standard horizontal flue inc. elbow 850mm 110mm 236921 Horizontal flue/wall terminal 850mm 110mm 243013BAX Flue extension 1000mm 110mm 241695 Flue extension 500mm 110mm 241694 Flue extension 250mm 110mm 241692 Flue bend 90 110mm 241687 Flue bend (pair) 135 110mm 241689 Flue terminal deflector 70mm 248167 Vertical flue adaptor (boiler) 110mm 5106888 Pipe support Painted white 110mm 243014BAX Vertical concentric flues 70/110mm Item description (MULTIFIT) flue system B Specification Key and OD dimensions Multifit sales code Vertical roof terminal 70/110mm 242802 Vertical flue adaptor (boiler) 110mm 5106888 Flue extension 1000mm 110mm 241695 Flue extension 500mm 110mm 241694 Flue extension 250mm 110mm 241692 Flue bend 90 110mm 241687 Flue bend (pair) 135 110mm 241689 Roof cover plate 243131 Pipe support Painted white 110mm 243014BAX Flat roof flashing 125mm 243016BAX Pitched roof flashing 25/50 125mm 243015 Plume displacement kits 70/110mm to 70mm PDK Item description (MULTIFIT) flue system L Specification Key and OD dimensions Multifit sales code Plume displacement kit inc. elbow and clips All HE Plus 110mm 5121371 Plume displacement kit extension inc. clip 1000mm 70mm 5121372 Plume displacement kit bend 93 70mm 5121373 Plume displacement kit bend (pair) 135 70mm 5121374 CONTROLS The perfect accessories: Maximise your customers energy saving Easy to commission Increase your revenue stream Wireless electronic digital room thermostat Portable room thermostat for ease of use and greater comfort 7 day programme time and temperature control Easy to read backlit LCD display Easy to use Digital and Dial control Perfect for fully personalised comfort and energy saving Integral electronic timer 7 day programme time and temperature control Easy to read backlit LCD display Multiple on/off switching operations Advanced switch programme Integral electro mechanical time clock Electro-mechanical 24 hour timer Selection of on/off control Tappets set around an analogue clock for the utmost simplicity Wireless (RF) electro mechanical room thermostat Wireless programmable room thermostat Minimises problems of compliance with building regulations Part L (Energy Conservation) and Part P (Electrical Safety) As simple to fit as it is to use 720030701 247207 247206 5117393 The accessories shown are only compatible with Main Combi appliances. 26

THE LOYALTY SCHEME FROM MAIN Welcome to the loyalty scheme from Main. It s called works and it s simple, easy to join and it gives you reward points for every single Main boiler or cylinder you purchase. You even earn reward points for building relationships with Main and other installers! THE BENEFITS TO YOU. Great rewards from the personal shopping catalogue Free Gas Safe Notification Next day call out Annual service reminder Be on Find an installer Sign up today! Visit works2gether.co.uk to start earning rewards or speak to your local Main Area Sales Manager for further details. MAIN REASSURING BACK-UP Customer Support 0344 871 1545 baxicustomersupport.co.uk Warranty Main: Giving you extra Boilers All Main boilers come with a 3 year parts and labour warranty until 31st December 2016. Cylinders On site service support including parts and labour for 12 months from date of installation. After an initial 12 months, a parts only guarantee will apply for a further 24 years on the stainless steel shell. Subject to registration and the replacement being carried out by one of our Baxi Customer Support engineers, for which reasonable labour charges will apply. With call service support available 7 days a week, 363 days a year, Baxi Customer Support offers quick and effective servicing and maintenance support through over 250 highly trained heating experts across the country. The Main trade technical helpline offers a range of free services to Main installers: In-warranty support. Help with installation problems. Boiler selection advice. Fault-finding assistance. Flue queries. Baxi Genuine Parts Approved parts for Main Heating products. Guaranteed quality, safety and reliability. Nationwide network of approved stockists. Lifetime support for Main Heating products. EXPERT TRAINING As well as superb support and technical advice, Main gives you access to the very latest training on all our products. The courses are run by qualified instructors and cover everything from installation and commissioning to servicing and diagnostics as well as current legislation, Building Regulations, energy efficiency, electronics, combi boilers, system design and condensing theory. In short, you ll learn everything you need to install every product in the Main range successfully and profitably. To book your place on a Main training course call: 0344 335 4207 Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should be provided to the customer for future reference. Installers are required to carry out installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is available from the Heating and Hot water Industry Council who manage and promote the Scheme. Visit www.centralheating.co.uk for more information. All descriptions and illustrations provided in this document have been carefully prepared but we reserve the right to make changes and improvements in our products which may affect the accuracy of the information contained in this leaflet. All goods are sold subject to our standard Conditions of Sale which are available on request. 27

Contacts All enquiries Tel: 0344 871 1570 Please note calls to the service centre may be recorded or monitored. Main Brooks House, Coventry Road, Warwick CV34 4LL. Website: mainheating.co.uk twitter.com/mainheating facebook.com/mainheating PART OF BAXI This Brochure is printed on paper sourced from well managed forests and other controlled sources. This Brochure is printed using vegetable based inks. Please recycle this Brochure when you have finished with it. Registered Office: Baxi Heating UK Limited, Brooks House, Coventry Road, Warwick CV34 4LL, United Kingdom. Registered No: 03879156 VAT Reg No: 604 6658 37 Main policy is one of continual improvement and development. The right to change specification and appearance without prior notice is reserved. The reproduction of colours is as accurate as photographic and printing processes allow. The consumer s statutory rights are not affected. e&oe M/Range 366902/12 01/16