Hoval AgroLyt (20-50) Log Wood Boiler

Similar documents
Hoval BioLyt (8-36) Pellet boiler

Hoval TopGas classic (12,18,24,30) Wall-hanging gas condensing boiler with or without water heating

Hoval BioLyt (50-160) Pellet boiler

GAS Hoval Responsibility for energy and environment. Hoval heating technology Hoval residential ventilation Hoval indoor climate systems GAS

Hoval Uno-3 ( ) Low temperature oil/gas boiler

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

Hoval UltraGas ( ) Floor-standing gas condensing boiler

Technical information Assembly instructions. UltraOil ( ) Oil condensing boiler

Technical information Installation instructions

Technical information Assembly instructions

Steel Shell Boilers. Max-3 plus kw. Max-3 E & Max-3 condens E kw. CompactGas kw. SR-plus and SR-H plus kw

Hoval TopGas (12, 16, 22)

Technical information Assembly instructions. Uno-3 (320, 360) Oil/gas boilers

Wood gasification process...3. Wood as a fuel...3. Boiler construction - its elements...4

Technical information Installation instructions

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

CALORIFIERS (Energy Storage Tanks) for domestic, commercial and industrial applications.

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

WOLF GAS CONDENSING BOILERS COMFORTLINE

Technical information Installation instructions. Modul-plus (F21-52) High performance calorifiers

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

Heating with log wood

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

1 VICTRIX ZEUS Superior kw I features

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Biomass. Biomass solid fuel boiler range

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

Technical information Installation instructions. Uno-3 ( ) Oil/gas boiler. These instructions apply to the following types:

Installation, operation and care Firewood boiler Vedolux 40 UB

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

Starting current with soft starter Fuse protection. Connection heating Seal of approval MCS (valid until)

Gasification boiler PYROLYT INSTRUCTION MANUAL. ver. 1.1

Multi Energy Boilers. Duo 1 & 2 Triplex 1000 & 3000 Biotriplex. Oil Gas LPG Wood Briquettes Electricity Solar thermal Solar photovoltaics

Installation Instructions

EWI-THERM Hot-Air Heating Systems Types Prestige-SE, Optimal-E and H-F-L

Starting current with soft starter Fuse protection

Operating instructions

Technical information Installation instructions. 41-TopGas (80) Gas condensing boiler for natural and liquid gas

Planning and installation guide HDG Compact 50/65 with HDG Hydronic

Technical information Installation instructions

TopGas Cascade Condensing Gas Boilers Technical Information and Assembly Manual Output range 60 to 720 kw /17 Subject to modification

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Protection and Control of Solid Fuel Boilers

Heating with wood chips

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

Installation and maintenance instructions

Boiler Technical Specifications (2013)

INSTALLATION INSTRUCTIONS LOGWIN PREMIUM TOUCH WOOD GASIFICATION BOILER 06/ /00

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model MICROGENUS PLUS. R EN - Edition 02-01/04/2007

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

Operating Instructions

Operating manual. Pellet boiler. Orlan Pellet ISO 9001

Installation and instruction manual SOLAR STATION

HERZ ECO-Line Heating with logs or wood pellets

Log fired heating system

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

REMKO Comfort-WP The versatile heat pump

Wood logs boiler with a gasication eect IGNIS KW. INSTRUCTIONS MANUAL for usage and maintenance

Dimplex High efficiency air-to-water heat pump for indoor installation. (Low temperature) Order reference

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Hoval Cosmo heating boilers, outputs from 100 to 4000kW. Working pressures to 8 bar. Heatpack boilers. to 2900kW.

HDG K SERIES. Wood pellet boiler. The perfect alternative to fossil fuels. Receive up to

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

HDG Euro V3.0 with HDG Lambda Control 1

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model CLAS. R EN - Edition 01-01/02/2007

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

REMKO HYBRID HEAT PUMPS

English. Heating with logs & wood pellets 20-40

Operating Guide. Termix Solar A+/B+ 1.0 Table of Contents. 1.0 Table of Contents

Installation instruction

Rozp.UE2015/ kw kw

THW-I NTE. Description THW-I NTE. Industrial Hot Water Boiler THW-I NTE for Oil or Gasfiring. Industrial Hot Water Boiler

Installation and maintenance instructions

CITY OPEN - CITY BOX from 25 to 35 kw

PELLET BURNER PV 350

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

Pioneers of heating with biomasses

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

AIEA Presentation. Wood pellets heating systems.

Installation instruction

Installation and operating instructions. DK energy storage and DK energy buffer

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

Data sheet SI 24TE. Brine-to-water heat pump with two performance levels

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Hoval SR-plus heating boilers Outputs from 350 to 4000kW Working pressures to 8 bar

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

ETA PE-K. The pellet boiler with technology that's built to last, for larger heating needs. 35 to 90 kw. A passion for perfection.

Easyfire Standalone biomass pellet boiler

Distributed*and*installed*in*the*UK*by*

Transcription:

Log Wood Boiler Description Hoval AgroLyt Heating boiler steel boiler in compliance with EN 303-5 for burning split wood, chippings or wood briquettes can be combined with separate energy storage unit integrated safety heat exchanger for thermal process control haust and air-cooled lining be adjusted vortex combustion chamber with pre-heating ducts and heat-proof ceramic inlet jets for the secondary air intake thermolytic secondary heating surfaces and auxiliary switch for automatic low-tempe rature gas exhaust system kindling and ash door placed above grate ash removal door for simultaneous access to combustion chamber options (delivered from factory): - with or without mechanical aid to clear and comfort WiKo (separately packed) - with boiler control panel N5.1 (separately packed) boiler door swivel-mounted to the left thermal insulation with 80 mm mineral wool matting (sep. packed) lining made of powder coated sheet steel (sep. packed) suction ventilator with automatic low-temperature gas exhaust, load dependent (ready wired and separately packed) Accessories (included with delivery) soot brush, ash scraper, poker and stand Delivery boiler, thermal insulation and casing plus boiler control panel and if required surface clearing aid delivered separately packed On site installation of the thermal insulation and casing of the heating boiler Installation boiler control panel WiKo aid for clearing heating surface (only with WiKo version) Plant test plant test and demonstration (obligatory) Model series AgroLyt Heating capacity ype kw (20) 20 (25) 25 (35) 35 (50) 50 Boiler control panel N5.1 boiler control panel for mounting on boiler or laterally to the left or right prepared for installation of a opronic heating controller Basic boiler control with: main switch I/O, boiler temperature display boiler temperature controller for two-stage operation boil er minimum temperature monitor for boiler start-up protection fan connector for door contact safety switch connector for suction ventilator connector for buffer charging pump E connector 230 V, 50 Hz WiKo clearing aid for Hoval AgroLyt mechanical aid to clear heating surface for im- Approval heating boiler AgroLyt (20-50) VKF No. 13369 VHe No. / HeS No. 0022/3 Return temperature control group type RH 32-K (thermal) only for AgroLyt with boiler control N5.1 consisting of: with cable ready for connection to boiler control N5.1. 3 shut off switch ball valves: - storage tank-return - - boiler return with thermometer sizes. Delivery return temperature control group and storage tank loading pump with cable supplied in se parate packaging. On site installation of the prepared return temperature control group on boiler mounting of biral pump Energy storage unit EnerVal Hot water storage tank with large lower flange for heating, electrical ignition cartridge and thermostats and thermometer. operating pressure: max. 3 bar operating temperature: max. 95 C As required: thermal insulation for energy storage unit. Subject to alterations, 1.8.2013 3

Log Wood Boiler Description Heating regulator set ZN2 As supplement to boiler control N5.1. Consisting of: heating regulator Hoval opronic /N for - 1 mixing circuit - hot water charging circuit possibility of further functions using various key modules large LCD display turn-and-press button keys for - day room temperature - night room temperature - hot water temperature - operating mode (holiday, absence, heating period extension, automatic, summer, heating period permanent reduced frost protection) - characteristic curve setting - plant information - emission measurement and manual operation outdoor sensor AF200 connection for room controls cable set for connecting the heating regulation opronic /N to the boiler control Delivery heating regulator set separately packed, installation on site 4 Subject to alterations, 1.8.2013

Part N Log wood boiler Hoval AgroLyt with basic boiler control N5.1 Part N Steel boiler with basic boiler control. Integrated safety heat exchanger for thermal process con trol. Boiler, boiler control panel and thermal insulation with lining delivered separately packed. AgroLyt capacity length length volume type kw m mm litres (20) 20 ½ 570 140 (25) 25 ½ 570 160 (35) 35 ½ 570 160 (50) 50 ½ 570 220 7007 091 7007 092 7007 094 7007 098 CAUION: It is essential to install a return temperature control! It is essential to install an energy-saving draught restrictor Z 15! See the notes under required draught and chimney Log wood boiler Hoval AgroLyt with basic boiler control N5.1 and heating surface clearing aid WiKo As described above, but including heating surface clearing aid WiKo. Boiler, boiler control panel, heating surface clearing aid and thermal insulation material with cladding supplied separately. AgroLyt capacity length length volume type kw m mm litres (20) 20 ½ 570 140 (25) 25 ½ 570 160 (35) 35 ½ 570 160 (50) 50 ½ 570 220 7007 101 7007 102 7007 104 7007 108 by about 35 C by use of the heating surface clearing device! Subject to alterations, 1.8.2013 5

Part N Log wood boiler Hoval AgroLyt with basic boiler control N5.2/ opronic lambda Part N but with boiler control N5.2/opronic lambda. tact sensor and energy buffer storage sensor for combustion and performance optimisation. Delivery: Boiler, boiler switch panel and thermal insulation with cladding are supplied separately packed. Lambda probe for optimising combustion and return temperature control group type RH32-M must be ordered separately (see accessories). CAUION: It is essential to install a return temperature control! It is essential to install an energy-saving draught restrictor Z 15! See the notes under required draught and chimney Nominal Log Filling capacity AgroLyt capacity length length volume type kw m mm litres (20) L 18,0 1/2 570 140 (25) L 25,0 1/2 570 160 (35) L 36,0 1/2 570 160 (40) L 39,7 1/2 570 160 (50) L 50,0 1/2 570 220 7007 111 7007 112 7007 114 7007 115 7007 118 Log wood boiler Hoval AgroLyt with basic boiler control N5.2 opronic lambda and heating surface clearing aid WiKo Configuration as on the previous page, but additionally with heating surface cleaning WiKo. Delivery: Boiler, boiler switch panel and thermal insulation with cladding and heating surface cleaning are supplied separately packed. Nominal Log Filling capacity AgroLyt capacity length length volume type kw m mm litres (20) L 18,0 1/2 570 140 (25) L 25,0 1/2 570 160 (30) L 27,2 1/2 570 160 (35) L 36,0 1/2 570 160 (40) L 39,7 1/2 570 160 (50) L 50,0 1/2 570 220 7007 121 7007 122 7007 123 7007 124 7007 125 7007 128 CAUION: It is essential to install a return temperature control! CAUION: load is reduced by approx. 35 C on average by the heating surface cleaning! It is essential to install an energy-saving draught restrictor Z 15! See the notes under required draught and chimney Lambda probe for AgroLyt (20-50) with boiler controller N5.2/opronic lambda for combustion optimisation incl. assembly accessories 6915 80 6 Subject to alterations, 1.8.2013

Part N Boiler accessories hermal return temperature control group type RH 32-K for AgroLyt (20-50) suitable for boiler control panel N5.1: hermal control valve 3-way valve and high-efficiency pump Part N 6022 624 Return temperature control group DN32 for return flow temperature increase With 3-way motor mixer and Biral pump Ball valves in installation flow/return Valve equipped with thermometer in boiler return Insulated piping Complete with fittings for assembly at boiler connection Connection: Rp 1¼" Pump enclosed separately. for AgroLyt (20,25) Mixer: kvs 12 m 3 /h for AgroLyt (35,50) Mixer: kvs 18 m 3 /h 6032 418 6022 628 Return temperature control kit DN25 for BioLyt (15,23), AgroLyt (20,25) for return flow temperature increase Consisting of: 3-way motor mixer kvs: 12 m 3 /h 6032 419 Return temperature control kit DN32 for BioLyt (25-36), AgroLyt (35,50) for return flow temperature increase Consisting of: 3-way motor mixer kvs: 18 m 3 /h 6027 843 Automatic ignition device Consisting of: hot air blower with electrical kit and cover hood; incl. assembly accessories. for AgroLyt (20) L for AgroLyt (25-40) L for AgroLyt (50) L 6027 955 6027 956 6027 957 Ash-tray for AgroLyt Consisting of: Upper and lower ash-trays, including wall bracket and fixing material. 6412 60 Wood chip chute for AgroLyt (20-50) for easier filling with wood chips and kindling. he proportion of wood chips or kindling should not exceed 50% of a wood load. Proper combustion is only to be ensured with a correct mixture of at least 50% log wood (½-metre). 6024 343 Subject to alterations, 1.8.2013 7

Part N Heating regulator set opronic Part N Control set to be fitted into the boiler switch panel on site. Delivery Heating control set packed separately Heating regulator set ZN2 as addition to boiler control panel N5.1 for the connection of the heating regulator opronic / N with the boiler controller Consisting of: Heating regulator opronic /N for - 1 mixer circuit - 1 domestic hot water loading circuit Outdoor sensor AF200 Flow sensor VF204 with 4 m cable 2 immersion sensors KV20/5/6 for calorifier and buffer storage unit with 5 m cable Cable set ZN2 Delivery: Heating regulator set separately packed, mounting on-site 6020 567 Heating regulator set N2 as addition to boiler control panel N5.2/ opronic lambda Consisting of: Heating regulator opronic /N for - 1 mixer circuit - 1 domestic hot water loading circuit Outdoor sensor AF200 Flow sensor VF204 with 4 m cable 2 immersion sensors KV20/5/6 for calorifier and buffer storage unit with 5 m cable Delivery: Heating regulator set separately packed, mounting on-site 6020 569 8 Subject to alterations, 1.8.2013

M M M M Hoval AgroLyt (20-50) Part N Accessories for heating regulation system opronic Part N 1-7 Key Modules for opronic for further functions in addition to the standard functions. Key module consisting of: function key for insertion into the opronic incl. fittings Only one key module possible! Standard functions already realised in the opronic. - 1 mixing circuit - hot water charging circuit Functions of the key modules key 2 nd mixing solid buffer solar module circuit bivalent 1 2 3 4 5 6 7 M 1 Key module 1 for 2 nd mixing circuit function key 1, 1 flow sensor, 2 loose plugs 6012 154 2 Key module 2 for solid fuel/ buffer storage unit/ bivalent plant function key 2, 3 immersion sensor, 4 loose plugs 6012 155 3 Key module 3 for solar plants function key 3, 1 collector sensor, 1 storage sensor, 4 loose plugs 6012 156 M 4 Key module 4 for 2 nd mixing circuit and solid fuel/ buffer storage unit/ bivalent plant function key 4, 1 flow sensor, 3 immersion sensor, 6 loose plugs 6012 157 M 5 Key module 5 for 2 nd mixing circuit and solar plant function key 5, 1 flow sensor, 1 collector sensor, 1 storage sensor, 6 loose plugs 6012 158 6 Key module 6 for solid fuel/buffer storage unit/bivalent plant and solar plant function key 6, 1 collector sensor, 4 immersion sensor, 6 loose plugs 6012 159 M 7 Key module 7 for 2 nd mixing circuit, solid fuel/buffer storage unit/ bivalent and solar plant function key 7, 1 flow sensor, 1 collector sensor, 4 immersion sensor, 8 loose plugs 6012 160 System Solutions and Applications see Hoval CD Sensor types Immersion-/ : yp KV20/5/6 (L = 5 m) calorifier sensor without immersion sleeve Flow sensor : ype VF204S with plug Collector sensor : ype P1000 (Silicon) Subject to alterations, 1.8.2013 9

Part N Accessories for heating regulation system opronic Room station RS- for opronic effective on one mixing circuit Part N 2034 939 Remote control RFF- for opronic effective on one mixing circuit 2022 239 Outdoor sensor AF 200 (may be included in the heat generator scope of delivery) for one mixing circuit or for the mean value (per regulator 2 outdoor temperature sensors possible) 2022 995 Cable sensor KV 20/5/6 with 5 m cable 2022 992 Contact sensor VF204 can be used as flow or return flow sensor with 4 m cable 2023 998 Flow temperature guard for floor heating system (heating circuit 1 guard) 15-95 C, differential gab 6 K, capillary tube max. 700 mm setting (visible from the out side) inside the housing cover Clamp-on thermostat RAK-W1000.S hermostat with strap, without cable and plug Immersion thermostat RAK-W1000.S SB 150 hermostat with pocket ½" - depth of immersion 150 mm, brass nickel-plated 242 902 6010 082 Flow temperature guard RAK-W1000.S SB 280 Range of switching temperatures adjustable with tools 15-95 C switching differential 6K hermostat with immersion sleeve ½" depth of immersion 280 mm brass nickel-plated 6010 083 Flue gas thermometer with drag indicator Ø 5 / 80x150 mm (mounting on site) Range of indication 100 C - 500 C 2412 37 10 Subject to alterations, 1.8.2013

Part N Accessories Damper Z 15 Damper Z130 and -piece 90 of stainless steel Inner Ø 150 mm Part N 6008 037 hermal process control unit SS20 Valve ¾" with capillary tube 1,3 m Immersion well ½", L 142 mm 2426 62 Safety set SG15-1" Suitable up to max. 50 kw complete with safety valve (3 bar) Pressure gauge and automatic air vent with cut off valve Connection: 1" internal thread 6411 84 hermal control valve for return flow temperature increase 57 C 1½" incl. integrated check valve kvs = 14 6409 29 Switchover unit: For alternating operation of a solid fuel boiler with a boiler of a different energy type or for start-up relief hree way valve B3G460 PN 10, 110 C, DN 32 case, shaft and segment made of brass maintenance-free O-ring seal Mounting optionally on left or right side kvs value 18 m 3 /h 2039 170 Actuator NR230-E-20 for three-way valve B3G460 Operating voltage 230V/50Hz Single wire control orque 10 Nm Actuation time 140 s manual/automatic positioning reversible direction of rotation and scale for position indicator 0...10 1 cable (2 m) for actuator mounted on the drive. Complete with assembly material 2452 35 Further information see separate brochure Flue gas thermostat AG 519 Switching temperature 80 C (switching differential approx. 15 K) 1 switchover contact 10 A at 230 V/ 50 Hz ohm resistive load Simple screw fastening on flue pipe, with 2 m connecting cable. ested according to DIN 3440 6412 56 Subject to alterations, 1.8.2013 11

echnical data Hoval AgroLyt with basic boiler control N5.1 ype (20) (25) (35) (50) Hoval AgroLyt N5.1 nominal heating capacity (N5.1) kw 20 25 35 50 heating capacity range (N5.1) kw 16-20 19-25 26-35 35-50 Data for deciduous wood usable heating value (tolerance ± 20 %) kwh 180 200 200 265 kg 47 53 53 70 combustion time at nominal heating capacity approx. h 7,8 6,8 4,9 4,5 log length m ½ ½ ½ ½ Data for coniferous wood usable heating value (tolerance ± 20 %) kwh 126 140 140 179 kg 35 39 39 50 combustion time at nominal heating capacity approx. h 5,4 4,9 3,5 3,2 log length m ½ ½ ½ ½ maximum heating boiler operating temperature C 85 85 85 85 minimum heating boiler operating temperature C 70 70 70 70 C 55 55 55 55 1 at nominal capacity without WiKo C 190 190 200 200 1 at nominal capacity with WiKo C 160 160 160 170 carbon dioxide CO 2 % 10-14 10-14 10-14 10-14 operating pressure / testing pressure bar 3,0/4,5 3,0/4,5 3,0/4,5 3,0/4,5 80 C boiler water temperature (N5.1) % >88 >88 >88 >88 11,0 % CO 2, humidity content of wood 20 % kg/h 64 76 105 144 throughput resistance wood boiler z-value 2,8 2,8 2,8 2,7 water side resistance at 10 K mbar 8,3 12,9 25,2 50,2 water side resistance at 20 K mbar 2,0 3,2 6,3 12,5 water throughput at 10 K m 3 /h 1,72 2,15 3,01 4,30 water throughput at 20 K m 3 /h 0,86 1,07 1,50 2,15 boiler water content litres 195 195 190 220 litres 140 160 160 220 thickness of boiler body insulation mm 80 80 80 80 weight with casing kg 750 750 760 835 without casing kg 680 680 690 745 width mm 350 400 400 400 height mm 620 620 620 840 depth mm 570 570 570 570 feeding aperture width x height mm 450x400 450x400 450x400 450x400 dimensions (with/without switch panel) width mm 860/690 860/690 860/690 860/690 (with/without switch panel) depth mm 1375 1375 1375 1375 height mm 1670/1500 1670/1500 1670/1500 1890/1720 dimensions for installation width mm 600 600 600 600 depth mm 1200 1200 1200 1200 height mm 1570 1570 1570 1790 hermal process control switching point for the thermal process control C 95 95 95 95 minimum throughput water quantity (cold water 10 C) m 3 /h 1,50 1,5 2,0 2,0 bar 2,0/6,0 2,0/6,0 2,0/6,0 2,0/6,0 Flue gas system 1 minimum draught required for boiler Pa 10 10 10 10 maximum permitted draught Pa 25 25 25 25 nominal electrical power requirement (N5.1) watts 80 80 80 80 1 A damper control must be installed. 12 Subject to alterations, 1.8.2013

Dimensions (Dimensions in mm) Height H2 * Height H1 Space requirements see separate drawing AgroLyt Height ype H1 H2 A C D (20-40) 1500 1570 1544 1335 1236 (50) 1720 1790 1764 1555 1456 * Required space Boiler control can be mounted on top or on left or right side 1a Boiler flow connection R 1¼" 1b Installation flow connection Rp 1¼" 2a Boiler return connection R 1¼" 2b Installation return connection Rp 1¼" 3 safety heat exchanger 2 x R ½" 4 connector safety group and air vent, Rp 1" 5 drainage R ¾" 6 flue gas sleeve Ø150 (outer) 7 immersion well for boiler water temperature sensor 8 sleeve for safety heat exchanger sensor Rp ½" 9 suction ventilator 10 electrical controls 11 aperture for cleaning 12 heating surface clearing aid Wiko Subject to alterations, 1.8.2013 13

Dimensions Space requirements (Dimensions in mm) approx. 700 Minimum spacing 700 mm. he cleaning aperture at the boiler must be easy to access. min 400 min 600 min 400 min 1200 Space requirements for mounting the side casing. After mounting the casing the boiler can be moved against the wall. Minimum lateral space requirements incl. control panel, for servicing the safeguard 14 Subject to alterations, 1.8.2013

Engineering Regulations and Guidelines he following regulations and guidelines must be observed: Hoval s technical information and installation instructions. Hoval s hydraulic and technical control regulations. Local building law Fire protection standard DVGW guidelines DIN EN 12828 Heating systems in buildings - Design of hot water systems. DIN EN 12831 Heating systems in buildings - Procedure for calculation of the standard heating capacity VDE 0100 Water quality Heating water he European Standard EN 14868 and the Directive VDI 2035 must be observed. Hoval boilers and calorifiers are designed for heating plants without significant oxygen intake (plant type I according to EN 14868). Plants with - continuous oxygen intake (e.g. underfloor heating systems without diffusion proof plastic piping) or - intermittent oxygen intake (e.g. where frequent refilling is necessary) must be equipped with separate circuits. reated heating water must be tested at least 1 x yearly. According to the inhibitor manufacturer s instructions, more frequent testing may be necessary. A refilling is not necessary if the quality of the heating water in existing installations (e.g. exchange of boiler) conforms to VDI 2035. he Directive VDI 2035 applies equally to the replacement water. New and if applicable existing installations need to be adequately cleaned and flushed before being filled. he boiler may only be fil led after the heating system has been flush ed! Parts of the boiler which are in contact with water are made of ferrous materials. On account of the danger of stress cracking corrosion the chloride, nitrate and sulphate contents of the heating water must not exceed 200 mg/l in total. he ph value of the heating water should lie between 8,3 and 9,5 after 6-12 weeks of heating operation. Filling and replacement water: For a plant using Hoval boilers untreated drink ing water is generally best suited as heat ing medium, i.e. as filling and replacement water. However, the quality of the un treat ed drinking water must fulfil the stand ard set in VDI 2035. Should the mains wa ter available not be suited for use then it must be desalinated and/ or be treated with in hibitors. he stipulations of EN 14868 must be observed. In order to maintain a high level of boiler ef fi ciency and to avoid overheating of the heat ing surfaces the values given in the ta ble should not be exceeded (dependent on boil er performance ratings - for multi-boiler plants rating of smallest boiler applies - and on the water content of the plant). he total amount of filling and replacement water which is used throughout the total service life of the boiler must not exceed three times the water capacity of the plant. Boiler room he boiler room must comply with fire regulations. he combustion air supply must be guaranteed. he air opening should be in the lee of the prevailing wind direction and may not be shuttered in any way. he minimum free opening cross-section is 200 cm 2. Space requirements sible (for the purpose of dismantling it). Buffer Storage Unit Selection Recommended minimum storage unit size AgroLyt storage unit volume * type minimum dm 3 (20) 1000 (25) 1500 (35) 2000 (50) 3000 out side temperature maximum 40 C, heating quan tity is taken up by the storage unit. Maximal filling quantity based on VDI 2035 [mol/m 3 ] 1 <0,1 0,5 1 1,5 2 2,5 3 >3,0 f H <1 5 10 15 20 25 30 >30 d H <0,56 2,8 5,6 8,4 11,2 14,0 16,8 >16,8 e H <0,71 3,6 7,1 10,7 14,2 17,8 21,3 >21,3 ~mg/l <10 50,0 100,0 150,0 200,0 250,0 300,0 >300 Conductance 2 <20 100,0 200,0 300,0 400,0 500,0 600,0 >600 Boiler size of individual boiler to 50 kw NO REQUIREMEN 20 l/kw 1 sum of alkaline earths 2 If the conductance in µs/cm exceeds the tabular value, a water analysis is necessary. Subject to alterations, 1.8.2013 15

Engineering Boiler Selection the hourly heating capacity demand of the building. how often the boiler must be fuelled so that the heating demand is covered in periods of minimum outside temperatures. type (20) type (25) type (35) type (50) loads/day loads/day loads/day loads/day Qh 1 2 1 2 1 2 1 2 kw C C C C C C C C 6 8-10 10-10 -10-10 12-5 -10-9 - 9-10 14-2 -10-5 -5-10 16 1-10 -1-1 - 8 18 3-10 1-10 1-10 - 5 20 5-10 3-10 3-10 - 2 25 6-8 6-8 2-10 30 9-2 5-10 35 10 0 7-5 40 9-3 45 9 0 50 11 2 Qh = Heating requirement at -10 C outside temperature C = he daily heating requirement can be met when at least this outside temperature prevails. Basis for calculation: Firing with deciduous wood, = 14 x Qh. Installation Buffer storage unit and return flow safeguard For the Hoval AgroLyt a buffer storage unit with automatic storage and charging con trol and boiler return flow control must be in stalled. hermal Process Control If a pressurised expansion chamber is in stalled then a thermal process controller must also be installed (in accordance with. SWKI regulation 93-1). Hydraulic switching Please observe the examples for use. Heat distribution For central heating of rooms an automatic temperature regulator with one or more mixing circuits should be installed. Plant with open expansion chamber he height of the plant must be such that at least the required minimum pressure in the suction pipe of the pump is maintained in order to prevent cavitation (see heading circulation pumps - pumps ) Plant with pressurised expansion chamber In accordance with the SWKI regulation 93-1 pressurised expansion chambers are only permissible in combination with a thermal process controller consisting of an integrated heat exchanger in the boiler together with a thermal discharge valve. he thermal process control must be connec ted to the cold water supply. he minimum required flow pressure is 2 bar. Minimum throughput: AgroLyt (20) = 1500 l/h (25) = 1500 l/h (35) = 2000 l/h (50) = 2000 l/h. he cleaning aperture for the connector (top of boiler) must remain easily accessible. Install water pipes vertically upwards. Safety valve A safety valve with an automatic air vent must be installed at the connector for the safety group. 16 Subject to alterations, 1.8.2013

Engineering Chimney / Flue System Connecting pipe Feed the flue pipe connecting increasing bet ween the heating boiler and the chimney with a gradient of 30-45 into the chimney, if possible. For a pipe longer than 1 m thermal insulation is necessary. he connecting pipe must be introduced into the chimney in such a way that no condensate can flow into the heating boiler. he connecting pipe must contain a circular, closable flue gas measurement aperture with an inner diameter of 10-21 mm. he ap er ture must be accessible through the ther mal insulation if present. Position: 2xD D 2D Required draught In calculating the chimney dimensions the chimney draught should be between 0,1 and 0,25 mbar (10-25 Pa). D 1D o reliably prevent the occurrence of excessive flue draught, it is essential to install a damper. he damper ensures a constant flue draught, protection of the heating equipment, effective ventilation of the flue and optimum energy utilisation. his is the only reliable way to protect the boiler against accidental overload. Chimney he Agrolyt must be connected to a chimney (flue gas temperature > 200 C). he effective height of the chimney must be at least 6 m. he chimney outlet should be higher than the roof ridge. he flue gas ducts must be capable of withstanding humidity, acidity and soot combustion and be approved for flue gas temperatures > 160 C. Existing chimneys must be renovated accord ing to the instructions of a chimney con structor. Determination of the flue gas duct crosssection in accordance with EN 13384 Part 1 and 2 A flue gas thermometer (included with the AgroLyt ) must be installed in the connecting pipe. his is necessary in order to maintain a high level of plant efficiency. An auxiliary air flap as chimney damper control is recommended. Non-binding standard values for chimney cross-sections made of chrome steel piping connecting pipe = 1,0. connecting pipe and heating boiler connecting pipe and chimney should be thermally insulated. Height above sea level AgroLyt type (20) (25) (35) (50) m Ø (mm) 11-15 175 175 175 200 6-10 175 200 200 225 m = effective chimney height Ø = minimum required chimney diameter (mm) Fuel air-dried, untreated log wood such as split logs, billets or roundwood. max. Ø 15 cm guidelines for dry storage: softwood 1 to 1½ years hardwood 2 to 2½ years untreated coarse wood chips (humidity < 30 %) including attached bark split wood (thus the proportion of coarse chips can be approx. 50 % according to quality). Pressed chips, shavings etc with diameter the use of bonding agents, in combination with 50 % split wood (thus the proportion of pressed wood can be approx. 50 % according to quality). Carpentry waste in the form of bonded wood providing this is free from wood protection 50 % split wood (thus the proportion of carpentry waste can be approx. 50 % according to quality). Fuels which may not be used - coke, coal - sawdust - plastic-coated waste wood - treated or painted wood - plastic - waste he burning of waste, of wood treated with wood preservatives or with a coating consisting of halogenated organic compounds is prohibited. Please observe the 1. BImSchV (first regulation for the implementation of the Federal immission control law) 6. Determining the approx. yearly fuel demand for central heating wood requirement kg kw x 500 loose deciduous wood kw x 1 loose coniferous wood kw x 1,5 kw kg, m 3 = max. heating demand in kw = approx. yearly wood consumption (note that the weight per m 3 can vary a great deal according to the wood quality). Subject to alterations, 1.8.2013 17

Examples Hoval AgroLyt with basic boiler control N5.1 Monovalent plant with distributor and charging group, thermal return flow control, 2 energy storage units, 1 calorifier and 1 heating circuit Hydraulic plan BDB010 DHW CW Monovalent plant with distributor and charging group, thermal return flow control, 2 energy storage units, 1 calorifier with solar plant and 1 heating circuit Hydraulikschema BDB060 DHW CW RS- Room station AF Outdoor sensor VF1 Flow sensor 1 VF2 Flow sensor 2 SF Calorifier heater sensor B1 Flow temperature guard (if required) MK1 Pump mixing circuit 1 MK2 Pump mixing circuit 2 (optional) M8 Buffer charging pump PF Hot water tank sensor SLP Calorifier loading pump SOP Solar circulation pump YK1 Actuator mixer 1 YK2 Actuator mixer 2 Y9 Switch over valve start up release (single wire system) KRLF Solar panel return sensor KSPF Solar tank sensor (calorifier / buffer) KVLF Solar panel flow sensor - P1000 CW Cold Water DHW Domestic Hot Water Notice: - his hydraulic schematic is a principle schematic. It does not contain all details for installation. he installation must be done according to local conditions, di mensioning and regulations - monitor must be built-in. - Shut-off devices to the safety valve (pressurized expansion tank, safety valve, etc.) are to safe against unintended closing! - Mount bags to prevent single pipe gravity circulation. 18 Subject to alterations, 1.8.2013

Examples Hoval AgroLyt with boiler control N5.2/ opronic lambda Monovalent plant with distributor and charging group, constant return flow control, 2 energy storage units, 1 calorifier and 1 heating circuit Hydraulic plan BDB110 AF 3 KVLF S 1 opronic VF1 B1 RS- WW DHW M K 1 S L P P Y P Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit AgroLyt ein neues Shape zu nehmen!!! lambda hovhovalhovalhova lh valhovalho ovalhoval lhovalhov YKR M 8 Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh valho Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh valho PF BP1 BP2 YK1 M S F Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhoval hovalhovalhova lhovalhovalhov alhovalhovalho valhovalhovalh ovalhovalhoval hovalhovalhova lhovalhovalhov alhovalhovalho valhovalhovalh ovalhovalhoval h SLVF KSPF 2 SOP W KRLF BRU HPE Y M9 CW KW Bivalent plant with distributor and charging group, constant return flow control, 2 energy storage units, 1 calorifier and partial solar heating. Hydraulic plan HDS030 AF 3 5 KVLF S 1 opronic VF1 B1 VF2 B1 RS- WW DHW Y P Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit AgroLyt ein neues Shape zu nehmen!!! lambda hovhovalhovalhova lh valhovalho ovalhoval lhovalhov YKR M 8 Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh valho Dies ist ein unerlaubter Weg! Gehen Sie einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhovalhov alhovalhovalhoval hovalhovalhovalh valho PF BP1 KSPF PF2 SLVF BP2 YK1 M M K 1 M K 2 YK2 M S L P Dies ist ein unerlaubter Weg! Gehen Sie S F einen Schritt zurück oder löschen Sie dieses Shape! Sie haben die Möglichkeit ein neues Shape zu nehmen!!! hovhovalhoval hovalhovalhova lhovalhovalhov alhovalhovalho valhovalhovalh KSPF SLVF 2 ovalhovalhoval min.0,2m hovalhovalhova 2 /m 2 lhovalhovalhov alhovalhovalho valhovalhovalh ovalhovalhoval h P KRLF W SOP1 W BRU MY 9 CW KW Bezeichnung /Notation / Denominazione /Désignation Klemme /erminal / Morsetti /Bornes Y9 PF SOP 1 KF VA1 SLV VA2 SLVF VE2 KRLF VE3 Option / opzione Solar / solaire / solare >~12m2 SLV SOP2 RS- Room station MK1 Pump mixing circuit 1 MK2 Pump mixing circuit 2 M8 Buffer charging pump SLP Calorifier loading pump SOP Solar circulation pump SOP1 Solar circulation pump 1 SOP2 Solar circulation pump 2 SLV Water by-pass solar circuit YK1 Actuator mixer 1 YK2 Actuator mixer 2 YKR Actuator return mixer Y9 Switch over valve start up release (single wire system) B1 Flow temperature guard (if required) SF Calorifier sensor S1 Calorifier sensor PF Buffer sensor BP1 Buffer sensor 1 BP2 Buffer sensor 2 BRU Return sensor AF Outdoor sensor VF1 Flow sensor 1 VF2 Flow sensor 2 KSPF Solar tank sensor (calorifier / buffer) SLVF Solar sensor (calorifier / buffer) KVLF Solar sensor (collector P1000) S1-S5 Differential control sensor CW Cold Water DHW Domestic Hot Water Notice: - his hydraulic schematic is a principle schematic. It does not contain all details for installation. he installation must be done according to local conditions, di mensioning and regulations - monitor must be built-in. - Shut-off devices to the safety valve (pressurized expansion tank, safety valve, etc.) are to safe against unintended closing! - Mount bags to prevent single pipe gravity circulation. Subject to alterations, 1.8.2013 19