Property of Monitronics Inc

Similar documents
Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Property of Monitronics Inc

First Alert 1200C Installer Notes M. Leuck

SECURITY SYSTEM 4110DL. Programming Form Programming Form Programming Form 4110DL-PRV3 10/96

Radionics D4112 Program Sheet

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

Tomorrow s technology for today s security needs.

AXI LED USER MANUAL (REV. 1.0)

FBII Security System. Programming Guide. Version 2.X. N9967PRV3 4/04 Rev. A

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

4-PGM Expansion Module

Digiplex LED Keypads User s Manual

User s Information Guide R2A

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Condominium Security Management System

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

INSTALLATION MANUAL PC56O. Version 1.OA

PROGRAMMING PROCEDURES (Table 3)

Alarm Control Panel WIC-16Z4P WIC-5Z2P. User Instructions

Summit 3208GLD USER MANUAL. Electronics Line

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

8-zone Expansion Module

TABLE OF CONTENTS TABLE OF CONTENTS 1

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

ITI Caretaker Basic Commands

Security System. User s Guide for the Text Command Center

636 and 646 Keypads. User s Manual

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

DL-250 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

D1265. User's Guide. Touchscreen Keypad

HILLS Series LED Code Pad User Manual

Version 1.03 January-2002 USER S MANUAL

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

L900 series USER MANUAL

Control/Communicator Installation Manual

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Security System. User Guide for the LED Command Center

IDS S E C U R I T Y IDS816. User Manual MANUAL NO B ISSUED DEC 2004 VERSION 2.00

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

System Introduction. 1.1 Specifications

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

VISTA-100 Commercial Fire & Burglary Partitioned System

Safewatch Pro 3000 System Manual

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

EVO192 v3.0 Fire and Burglary What s New

Content. 1. Introduction to the IDS Features Installation and Wiring End-of-Line Resistors/Tamper per Zone...

XT30/XT50 PROGRAMMING PART 2. Slide 1. Slide 2. Slide 3. Objectives. XT30/XT50 Basic Training Programming- Part 2. Bell Options

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

Contents. Glossary

SECURITY SYSTEM NOTES SPECIAL CODES ENTRY / EXIT DELAY TIMES ARM / DISARM CODES ZONE DESCRIPTIONS

RE6100 Series Helix Security and Automation Platform

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

DS7446KP. User Guide. Keypad

ICP-CC488 ICP-CC488 EN. Control Panel. User s Guide

NetworX Series NX-6 CONTROL PANEL. Installation and Startup

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

Digiplex LED Keypads. User s Manual

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Using Your. Security System With LED Keypad S5030, S5031, S5032

INSTALLATION MANUAL PC15OO

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

GEM-P800. Control Panel/Communicator. Installation Instructions

USER GUIDE HARDWIRED CONTROL PANELS

Contact ID as of 2/2/2015

NETWORX TM. User manual NX-4

Elite 64 Version 64 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

XRSuper6. User s Guide

GEM-P800 Programming Instructions

$'(0&2 9,67$ 3DUWLWLRQHG 6HFXULW\ 6\VWHP 8VHU *XLGH N7003V3 5/04 Rev A

Elite 16D Version 16 Zone Controller Arrowhead Alarm Products Ltd. Operating Guide. Proudly Designed and Manufactured in New Zealand

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Solution Ultima 862 Operators Manual ISSUE 1.10

ICP-CC408 ICP-CC408 EN. Control Panel. User s Guide

How to Use Your Sentrol Security System

Solution Ultima Series Operators Manual ISSUE 1.00

Solution-8248 Installation Manual ISSUE 1.16

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

IDS S E C U R I T Y IDS816. User Manual MANUAL NO C ISSUED APRIL 2005 VERSION 2.00

Control Panel ICP-SOL2-P/ICP-SOL3-P. en User's Guide

Installation Manual Premier 412/816/832. Issue 10

Control/Communicator

Transcription:

Enter Program Press CODE key + * + 2468 + 1 (also try 2121) Installer Options Move to location Program location Exit Program Default Panel Hex Program Code + * + Installer Code + 1 = Enter Programming Code + * + Installer Code + 2 = System Log View Code + * + Installer Code + 3 = Unattended Downloading (Answer download request) Code + * + Installer Code + 4 = On-Line Download (Send to downloader) Press * + 2 digit location Press # after each digit and move to next location (Example enter 1#8#0#0# etc) Press STAY Short "EEPROM RESET" pins on panel and power up CODE+1 = A, CODE+2 = B, CODE+3 = C, CODE+4 = D, CODE+5 = E, CODE+6 = F Report Codes Zone 1 31 Duress 21 to 29 Zone 2 32 Keypad Fire Panic 19 Zone 3 33 Keypad Police Panic 29 Zone 4 34 Keypad Medical Panic 49 Zone 5 35 Low Battery 78 Zone 6 36 Low Battery Restoral 98 Zone 7 37 AC Failure 79 Zone 8 38 AC Failure Restoral 99 Zone 9 39 Fire Trouble 76 Zone 10 41 Fire Restore 96 Zone 11 42 Smoke Detector* 16 or 18 Zone 12 43 Cancel D1 to D8 Zone 13 44 Opening 5 + User Zone 14 45 Closing 6 + User Zone 15 46 Test/Download Complete EE Zone 16 47 Zone Restores 9 + Zone *01 Primary Phone (12 Digits) I I I I I I I I I I I I I L5 L6 L7 L8 L9 L10 L11 L12 A = End of Phone Number D = TouchTone # B = TouchTone * E = *70C = Disable Call Waiting C = 3 second pause F = 800 *02 Secondary Phone (Not Used) I I I I I I I I I I I I I L5 L6 L7 L8 L9 L10 L11 L12 *03 Download Phone (Not Used) I I I I I I I I I I I I I L5 L6 L7 L8 L9 L10 L11 L12 *04 Dialer Information I _1 _I 6 I _6 I 1 I L1 Dialer Format L2 Receiver Type 0 Pulse Dialing, Standard Format or 4x2 0 10PPS 1400Hz No Parity 1 Touch Tone Dialing, Standard Format or 4x2 1 10PPS 1400Hz Parity 2 Pulse Dialing, Extended Format 2 10PPS 2300 No Parity 3 Touch Tone Dialing, Extended Format 3 10PPS 2300Hz No Parity 4 Pulse Dialing, Partial Extended Format 4 20PPS 1400Hz No Parity 5 Touch Tone Dialing, Partial Extended Format 5 20PPS 1400Hz, Parity 8 No Dialer, Local Only System 6 20PPS 2300Hz No Parity 7 20PPS 2300Hz Parity 8 40PPS 1400Hz No Parity A 40PPS 2300Hz No Parity B 40PPS 2300Hz Parity L3 Message Type L4 System Options 0 3x1, No Bell Lockout 0 Silent Panic 2 4x1, No Bell Lockout 1 Audible Panic 6 4x2, No Bell Lockout 2 Silent Panic, Split Reporting 8 3x1, Bell Lockout 3 Audible Panic, Split Reporting A 4x1, Bell Lockout 4 Silent Panic, 24Hr Test E 4x2, Bell Lockout 5 Audible Panic, 24Hr Test 6 Silent Panic, Split Reporting, 24Hr Test 7 Audible Panic, Split Reporting, 24Hr Test 8 Silent Panic, Bell Test 9 Audible Panic, Bell Test A Silent Panic, Split Reporting, Bell Test B Audible Panic, Split Reporting, Bell Test C Silent Panic, 24Hr Test, Bell Test D Audible Panic, 24Hr Test, Bell Test E Silent Panic, Split Report, 24Hr Test, Bell Test

*05 Keypad Options I _F _I 2 I _6 I 0 I (if STAY doesn't work panel may be v3 XL-21, program F E 6 0 Instead) L1 Keypad Emergency Conditions L2 Misc Options (Standard XL-21 only) 0 Panics Disabled 0 Panic Input Silent, Auto unbypass 1 Panic Enabled 1 Keyswitch Input, Auto unbypass 2 Fire Enabled 2 Panic Input Audible, Auto unbypass 3 Panic, Fire Enabled 4 Panic Input Silent 4 Medical (Silent) Enabled 5 Keyswitch Input 5 Panic, Medical (Silent) Enabled 6 Panic Input Audible 6 Fire, Medical (Silent) Enabled 8 Panic Input Silent, Auto unbypass, Arm Only User 5 7 Police, Fire, Medical (Silent) Enabled 9 Keyswitch Input, Auto unbypass, Arm Only User 5 C Medical (Audible) Enabled A Panic Input Audible, Auto unbypass, Arm Only User 5 D Panic, Medical (Audible) Enabled C Panic Input Silent, Arm Only User 5 E Fire, Medical (Audible) Enabled D Keyswitch Input, Arm Only User 5 F Panic, Fire, Medical (Audible) Enabled E Panic Input Audible, Arm Only User 5 L2 Misc Options (XL-21 v3.0 only) 0 Panic Input Silent, Instant Mode Disabled 1 Zn 7 Keyswitch, Instant Mode Disabled 2 Panic Input Audible, Instant Mode Disabled 4 Panic Input Silent, Stay+Instant Mode Enabled 5 Zn 7 Keyswitch, Stay+Instant Mode Enabled 6 Panic Input Audible, Instant+Stay Enabled 8 Panic Input Silent, Instant Mode Enabled 9 Zn 7 Keyswitch, Instant Mode Enabled A Panic Input Audible, Instant Mode Enabled C Panic Input Silent Instant & Stay+Instant Enabled D Zn 7 Keyswitch, Instant & Stay+Instant Enabled E Panic Input Audible, Instant & Stay+Instant Enabled L3 Quick Commands 0 Quick Commands Disabled 1 Quick Force Arm (# 2) 2 Quick Arm (# 1) 3 Quick Force Arm, Quick Arm 4 Reset Enable (* Key for Smoke Detectors) 5 Quick Force Arm, Reset Enable 6 Quick Arm, Reset Enable 7 Quick Force Arm, Quick Arm, Reset Enable 8 Quick Bypass 9 Quick Force Arm, Quick Bypass A Quick Arm, Quick Bypass C Reset Enable, Quick Bypass D Quick Force Arm, Reset Enable, Quick Bypass E Quick Arm, Reset Enable, Quick Bypass F Quick Force Arm, Quick Arm, Reset Enable, Quick Bypass L4 Restore Follower/User Download, Test Ringback 0 Restore Follows Bell, STAY/INSTANT Keys Enabled 1 Restore Follows Loop, STAY/INSTANT Enabled 2 Restore Follows Bell, STAY/INSTANT Enabled, User Download Enabled 3 Restore Follows Loop, STAY/INSTANT Enabled, User Download Enabled 4 Restore Follows Bell, STAY/INSTANT Enabled, CS Test Ringback Silent 5 Restore Follows Loop, STAY/INSTANT Enabled, CS Test Ringback Silent 6 Restore Follows Bell, STAY/INSTANT Enabled, User Download, CS Test Ringback Silent 7 Restore Follows Loop, STAY/INSTANT Enabled, User Download, CS Test Ringback Silent 8 Restore Follows Bell, INSTANT Key Disabled 9 Restore Follows Loop, INSTANT Key Disabled A Restore Follows Bell, User Download, INSTANT Disabled B Restore Follows Loop, User Download, INSTANT Disabled C Restore Follows Bell, CS Test Ringback Silent, INSTANT Disabled D Restore Follows Loop, CS Test Ringback Silent, INSTANT Disabled E Restore Follows Bell, User Download, CS Test Ringback Silent, INSTANT Disabled F Restore Follows Loop, User Download, CS Test Ringback Silent, INSTANT Disabled

*06 System Timeouts I _2 _I 4 I _2 I F I L1 Entry Delay 1 L2 Exit Delay 0 1 Second 0 1 Second 1 5 Seconds 1 10 Seconds 2 10 Seconds 2 20 Seconds 3 15 Seconds 3 30 Seconds 4 20 Seconds 4 40 Seconds 5 25 Seconds 5 50 Seconds 6 30 Seconds 6 1 Minute 7 35 Seconds 7 1 Minute 10 Seconds 8 40 Seconds 8 1 Minute 20 Seconds 9 45 Seconds 9 1 Minute 30 Seconds A 50 Seconds A 1 Minute 40 Seconds B 55 Seconds B 1 Minute 50 Seconds C 1 Minute C 2 Minutes D 1 Minute 5 Seconds D 2 Minutes 10 Seconds E 1 Minute 10 Seconds E 2 Minutes 20 Seconds F 3 Minutes F 3 Minutes L3 Burg Bell Cutoff L4 Fire Bell Cutoff 1 3 Minutes 1 3 Minutes 2 6 Minutes 2 6 Minutes 3 9 Minutes 3 9 Minutes 4 12 Minutes 4 12 Minutes 5 15 Minutes 5 15 Minutes 6 18 Minutes 6 18 Minutes 7 21 Minutes 7 21 Minutes 8 24 Minutes 8 24 Minutes 9 27 Minutes 9 27 Minutes A 30 Minutes A 30 Minutes B 33 Minutes B 33 Minutes C 36 Minutes C 36 Minutes D 39 Minutes D 39 Minutes E 42 Minutes E 42 Minutes F Infinite F Infinite *07 Misc System Options I _6 _I A I _0 I 0 I L1 Entry Delay 2 (Zones 4 to 6 only) L2 Ring Count 0 1 Second 0 Downloading Disabled 1 5 Seconds 1 1 Ring to Answer 2 10 Seconds 2 2 Rings to Answer 3 15 Seconds 3 3 Rings to Answer 4 20 Seconds 4 4 Rings to Answer 5 25 Seconds 5 5 Rings to Answer 6 30 Seconds 6 6 Rings to Answer 7 35 Seconds 7 7 Rings to Answer 8 40 Seconds 8 8 Rings to Answer 9 45 Seconds 9 9 Rings to Answer A 50 Seconds A 10 Rings to Answer B 55 Seconds B 11 Rings to Answer C 1 Minute C 12 Rings to Answer D 1 Minute 5 Seconds E 1 Minute 10 Seconds F 3 Minutes L3 Test Time Interval/Euro Ring Detect L4 Trigger Types 0 1 Day (24 Hours) 0 Smoke Power Output/Reset Enable 1 7 Days (Weekly) 1 Fire Bell ON, Follows Fire Bell Timer 2 27 Days (Monthly) 2 Burg Bell ON, Follows Burg Bell Timer 3 60 Days 3 Line Seizure, Follows Line Seizure Relay 4 90 Days 4 Ready, Follows Ready LED 8 1 Day (24 Hours), Euro Ring Select 5 Armed, Follows Armed LED (Steady States Only) 9 7 Days (Weekly), Euro Ring Select 6 Exit Time, ON during Exit Time A 27 Days (Monthly), Euro Ring Select 7 Entry Time, ON during Entry Time B 60 Days, Euro Ring Select 8 Fire Only Latch, ON w/fire Bell, OFF w/code C 90 Days, Euro Ring Select 9 Burg Only Latch, ON w/burg Bell, OFF w/code A Strobe, ON Steady w/burg, OFF w/code B Panic Alarm, Zone 7 ON w/alarm, OFF w/code C Shock Reset, * Activates for 2-6 Sec

*09 Account 2 I _ I _ I I I *09 Account 2 I _A I _A I A I A I (Not programmed) *10 Zone 1 Programming I _? I _? I _3 I 1 I (Sends 31) *11 Zone 2 Programming I _? I _? I _3 I 2 I (Sends 32) *12 Zone 3 Programming I _? I _? I _3 I 3 I (Sends 33) *13 Zone 4 Programming I _? I _? I _3 I 4 I (Sends 34) *14 Zone 5 Programming I _? I _? I _3 I 5 I (Sends 35) *15 Zone 6 Programming I _? I _? I _3 I 6 I (Sends 36, If Smoke use 8416) 1 st 2-digits are Zone Type, 2 nd 2-digits is Report Code L1 & L2 Zone Type 10 Perimeter 44 Interior, Chime 11 Perimeter, Restore 45 Interior, Chime, Restore 12 Perimeter 48 Interior, Dial Delay 13 Perimeter, Day, Restore 49 Interior, Restore, Dial Delay 14 Perimeter, Chime 4C Interior, Chime, Dial Delay 15 Perimeter, Chime, Restore 4D Interior, Chime, Restore, Dial Delay 18 Perimeter, Dial Delay 19 Perimeter, Restore, Dial Delay 24 Hour Zones 1A Perimeter, Day, Dial Delay 81 Alarm Audible 1B Perimeter, Day, Restore, Dial Delay 84 Fire 1C Perimeter, Chime, Dial Delay 89 Alarm Silent 1D Perimeter, Chime, Restore, Dial Delay 8A Trouble, Silent (LED Indicator Only) 20 Delay 91 Alarm Restore (Silent) 21 Delay, Restore 92 Trouble, Audible, Restore 24 Delay, Chime 94 Fire, Restore 25 Delay, Chime, Restore 99 Hold Up, Restore 40 Interior 9A Silent Trouble, Restore 41 Interior, Restore 41 Interior, Bypass in Stay (Motions) *16 Ambush/AC Loss I _2 _I 6 I _7 I 9 I (Ambush = 26. AC Loss = 79) *17 Police Panic/Low Battery I _2 _I 9 I _7 I 8 I (Panic = 29. Low Battery = 78) *18 Open/Close/Test I _A I _A I A I A I (For Opening/Closings use 5 6 A A) *19 Bypass/Restore/Trouble/Cancel I _A I _A I 7 I A I (Fire Trouble sends 7 + Zone) *20 Keypad Fire/Medical Panics I _1 _I _9 I _4 _I 9 I (Fire Panic = 19, Medical Panic = 49) *00 Installer Code I _2 _I _4 I _6 _I 8 I

Monitronics Monitoring and Service: 1-800-447-9239 FBI XL-2S Silver/XL-21 Quick Reference Guide Arm Away Enter User Code, ARM light will turn on Arm Stay Arm Instant Disarming / Silencing Alarms Zone Bypassing User Codes Press STAY + User Code When system is disarmed the motions will return to normal Press INSTANT + STAY + User Code All zones will return to normal when system is disarmed Enter User Code If disarming after an alarm enter User Code again to clear any Alarm Displays Press BYPASS key + User Code + Zone to Bypass (1 to 6) To bypass more zones press BYPASS key then any other zone you wish to bypass Bypassed zones will return to normal when you arm then disarm your system Press CODE + Master Code Enter User to add or change (2 to 5) Enter new 4-digit User Code (keypad will beep indicating you have successfully entered the code) To delete a User Code repeat above steps except press instead of entering a new User Code NOTE: The 1 st code is the Master code, the 6 th code is a Duress/Hostage code (if programmed) Reset Smoke Detector Enter User Code then. The smoke detector will be reset after a few seconds Trouble Indicators Door Chimes Press # 6 to Enable or Disable Panic Buttons if AC/LB light is OFF the AC power has failed If AC/LB light is FLASHING the backup battery is low and needs to recharge or be replaced Press and # for Police Panic Press 1 and 3 for Medical Panic (Fire and Medical Panics may not be enabled on some systems) Press 7 and 9 for Fire Panic If keypad has separate Police, Fire and Medical keys press both at same time to use