High Efficiency Dehumidification System (HEDS)

Similar documents
High Efficiency Dehumidification System (HEDS)

September 19, 20, 2009 Fort Lee, VA

Design Standard. Thermal Systems (Chilled Water and Hot Water Systems) Detailed specifications follow. CHW AND HHW SUPPLY TEMPERATURE RESET

HVAC 101. H V A C S y s t e m s

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Benefits Offered by Passive Dehumidification Wheel Speed Control

EarthWise System Seminar

HVAC DISTRIBUTION and DELIVERY SYSTEMS

Submitted to. Texas A&M University-Corpus Christi The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Design Considerations For Dedicated OA Systems BY HUGH CROWTHER, P.ENG, MEMBER ASHRAE; YI TENG MA, ASSOCIATE MEMBER ASHRAE

Select DOAS, Ceiling Radiant Cooling Panel- Chilled Beam Projects. Updated 9/23/2008

Ventilation and Humidity Control in Army Barracks Using DOAS for Better Indoor Air Quality and Energy Conservation

HVAC Efficiency In Healthcare. Presenter Mr. Nate Lincoln

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

Senior Thesis Centre Community Hospital East Wing Addition - Proposal Keith Beidel Mechanical Option 12/05/02 1

Civil Engineering Building

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

Dehumidification: Energy Efficiency Comparisons

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Solar Air Heating Roofing and Siding for Government and Commercial Buildings

Efficient energy recovery in AHU. DOHA, Qatar Timo Schreck Enventus AB, Sweden

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

ENGINEERING. Edition No. 13 October 2002

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

APPLICATION GUIDE BEAMS

Systems Approach to Improved Facility Energy Performance

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

National Institutes of Health Building 37 Modernization Bethesda, Maryland MECHANICAL DEPTH EXISTING MECHANICAL SYSTEM

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Madeira City Schools Madeira, Ohio. HVAC Assessment. December 2011 (Revised February 2012)

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

Executive Summary. OA/person (cfm/p) Private and open offices, Classrooms, Building as designed

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

ASHRAE Standard 90.1 Energy Requirements Wrap-Around Heat Pipes

Auburn University Basketball Arena:

LATENT COOLING LEAD. Kecha Thirakomen EEC Engineering Network

HVAC: The Next. Variable-air-volume systems. Outside-the-box thinking suggests the integration of dedicated

Technical Report Three

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

Solar Air Heating Metal Roofs for Re-Roofing and New Construction

Dehumidifying with Dedicated Outdoor Air

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

7. MECHANICAL SYSTEM DESIGN

Computing Services Center

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

Physical Plant Complex

Harrington Tower Building

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

CHAPTER 4. HVAC DELIVERY SYSTEMS

ASHRAE S DOAS WEBCAST: A DEEPER EXAMINATION OF THE ROLE OF HEAT PIPES

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

New PHE applications in construction & HVAC.

RoofPak Applied Rooftop Systems

Appendix 13. Categories of Cooling and Heating systems

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

MAXIMIZING FACILITY PERFORMANCE WITH INNOVATIVE HVAC & IRRIGATION SYSTEMS

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

Humidity Control in Tropical Climate with Heat Pipes - The GREEN Way

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Technical Assignment 3

DADANCO Technical Paper

Active & Passive Beams

Description of All Alternatives Considered-

4-Pipe VAV vs. Active Chilled Beams for Labs

4.0 Mechanical Redesign

ASHRAE Guideline 36 Advanced HVAC Control Sequences

NON-REVERSING, 100% OUTSIDE AIR HEAT PUMP FOR HEATING AND COOLING

Trane CDQ Desiccant Dehumidification

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

Custom Performance Climate Changer air handlers. Expertly designed and built to meet your specific requirements

THIS IS A DESIGN GUIDE NOT A SPECIFICATION. Montgomery County Public Schools Facilities Guide DIVISION 15 MECHANICAL

Raised Access Floor - (AE Breadth Area)

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

AHRI 920 & ASHRAE 90.1

Mechanical Systems Thesis Proposal: Calvert Memorial Hospital Prince Frederick, MD Holly Mawritz

HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

White Paper Dehumidification in Humid Climates - A Theoretical Case Study

3 years payback time. Millions of reasons to choose the best. Energy Demands? Comfort Problems? Maintenance Concerns?

Industrial Workshop Gettysburg, PA February 26, 2004

Displacement Ventilation

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

Transcription:

Advanced HVAC Technologies High Efficiency Dehumidification System (HEDS) Scot Duncan, P.E., Jim Meacham, P.E. Conservant Systems, Inc. August 16, 2017 Tampa Convention Center Tampa, Florida

Why Was HEDS Originally Created? To solve massive energy waste and mold growth problems for our Military! The HEDS inventor, Scot M. Duncan, P.E., is an Energy Efficiency and Relative Humidity control Subject Matter Expert for the U.S. Army Corps of Engineers (USACE). The High Efficiency Dehumidification System or HEDS was developed because we got sick of seeing mold growth in the living spaces of the military facilities that we were evaluating for energy efficiency upgrades. Current HVAC designs actually promote mold growth at many facilities! 2

HVAC-System Caused Biological Growth is a Serious Issue Throughout Many Federal Facilities Mold in AHU enclosures Mold in ductwork from high RH and condensate blow off Mold in spaces from condensation 3

What is HEDS? The High Efficiency Dehumidification System is a simple, energy efficient, easy to maintain method of controlling RH and biological growth HEDS can be deployed as a new chilled water AHU, or as an AHU retrofit Reduces chiller plant and boiler plant energy consumption for dehumidification 60% to over 80% while reducing or eliminating biological growth Contributes to healthier IAQ which leads to increased health, wellness and productivity Winner of the 2016 Department of Energy FEMP JUMP national energy efficiency competition and 2014 DoD ESTCP competition 4

Typical Dehumidification/Reheat AHU vs. HEDS Small cooling & reheat coils High CHW flow rates Low CHW temperature differential High AHU air pressure drops Propensity to suffer Low Delta T Syndrome Very large cooling & cooling recovery coils Low CHW flow rates High CHW temperature differential Low AHU air pressure drops Reduces Infrastructure, O&M Costs Eliminate Low Delta T syndrome = Added savings 5

ESTCP Field Test Sites Deployed in 2016 Fort Bragg Constant Air Volume Kitchen Application Tinker AFB Variable Air Volume Administrative Application Tested across a range of conditions to represent potential applications, including tropical conditions

HEDS Field Performance Results 7 Application Operating Rooms, Industrial Clean Rooms Hot / Humid Climates Dining Facilities (DFACs), barracks, Dedicated Outdoor Air Systems, (DOAS), general hospital areas, laboratories, industrial clean rooms, equipment coating facilities, and Corrosion Control Facilities Less Humid Environments Office and Administrative Tested Supply Dewpoint Temperature Range (lower equals drier) AHU Cooling Load % Reduction AHU Dehum Heating Load % Reduction Estimated Total Dehumidification- Related Cooling + Heating Plant Energy Savings Less than 50 F 20% 100% 57-81% Between 50 F and 52 F Between 52 F and 56 F Between 50 F and 56 F 31% 100% 63-85% 37% 100% 67-87% 27% to 29% 100% 79-91%

HEDS Field Performance Results Fort Bragg Cooling Load W/O HEDS (blue line) Cooling Load Sent to Plant with HEDS (orange Line) HEDS Cooling Load Savings % (grey Line) 8

HEDS Chilled Water System Temperature Differentials HEDS Eliminates Low Delta T Syndrome Cooling Coil CHW TD above 14F, even at 30% load HEDS TD @ 30% to 50% load is 14F to 21F Base case ran around 3F to 7F with Low Delta T Syndrome Eliminating Low Delta T Syndrome can increase savings by over 30% at many sites. From a CHW Flow Perspective, the system sees a 14F to 21F TD. From a CHW Load Perspective, the CHW System sees a 10F to 15F TD. The Difference is the Load and Reheat Savings. 9

Financial Benefits of HEDS Total energy savings relate directly to how much dehumidification is needed and required hours of operation Annual savings also vary based on application, electricity rate, gas rates Simple paybacks as low as 2 years in hot and humid climates New AHU put in place 20+ year lifetime equipment uses materials of construction to match local environment 10

HEDS Scheduling Benefits Many buildings with 5 or 7-day schedules that are not occupied 24x7 must be run 24x7 due to RH control issues HEDS eliminates the need to run facilities 24x7 due to larger latent coil capacities, increased usable chiller plant capacity and embedded control functions Continuous nighttime pressurization: running 100% OA at ~10% of rated airflow with very low dewpoint and higher drybulb to keep space dry and pressurized Batch dehumidification mode based on space conditions to pull down moisture 11

Other HEDS Benefits Built in Fault Detection and Diagnostics to support on-going operations Potential for increased ventilation rates without energy penalty Improved energy efficiency with advanced control reset strategies built in Airflow and energy monitoring to support additional IEQ and M&V credits Any HVAC mechanic can maintain it there is no added equipment over that of a normal CHW AHU. 12

HEDS in Retrofit Applications HEDS can typically be built into an existing air handling units or designed for replacement AHUs, DOAS s, FCU s etc. HEDS units may be larger or taller than existing equipment dimensions, depending on current configuration Key benefits from HEDS in retrofit applications: Fast return on investment from energy savings associated with cooling load reductions and elimination of reheat for dehumidification Significantly improved relative humidity control which can eliminate the potential for biological growth, improve workplace health, and save lives Can help to eliminate costs for facilities that are quarantined or condemned due to biological growth Increased chilled water plant capacity and improved chilled water system efficiency and operations from reduced cooling loads and higher delta T 13

HEDS in New Construction and Major Renovation Applications Easily integrates into existing HVAC air-side distribution system designs HEDS will typically fit the space allowed for new HVAC equipment Advanced specification and consideration in design are not required, but there can be many Value Engineering benefits: Reduced chilled water plant capacity (smaller chillers, cooling towers, pumps) Reduced pipe diameters from lower chilled water flows Reduced complexity and cost when compared with typical dehumidification solutions such as run around coils and dessicant-based solutions Elimination of boiler and/ or electric reheat requirements in hot and humid climates In large campus-type applications, may be able to add buildings without increasing chiller plant and distribution piping sizes 14

Frequently Asked Questions Where does HEDS not work? Applications where dehumidification and RH control are not needed, such as non-critical areas in arid climates Does the installation of HEDS require an entirely new AHU? No. HEDS can be retrofit to existing AHUs in many situations, depending on available space and existing unit configuration. Is there only one type/manufacturer of AHU offered with HEDS units? No. HEDS units can be designed in all AHU makes/models, in sizes from <100 to >1MM CFM. Are the HEDS unit savings calculations hypothetical, or have they been verified? HEDS savings have been validated in the field at 2 DoD ESTCP test sites in OK and NC, with third party validation in process from the DoD, USACE, DOE and ORNL How do I know if HEDS is a good fit for my applications? Conservant will work with your team to analyze the feasibility, potential costs and savings to develop a comprehensive solution 15

HEDS Summary HEDS leverages a simple AHU design with advanced controls to provide improved dehumidification/ reheat control Reduces chilled water loads 20% to >30%, can eliminate or significantly reduce reheat loads, and can reduce overall energy use associated with dehumidification and RH control by over 60% Eliminates HVAC-induced mold growth Improves occupant comfort and well-being Has built-in FDD to support on-going performance Commercially available and proven technology 16

Questions and Discussion Thanks for your time! Jim Meacham, P.E. jmeacham@conservantsystems.com Scot Duncan, P.E. sduncan@conservantsystems.com Tampa Convention Center Tampa, Florida