DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

PROVIDING HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

PROVIDING EXTRA-HIGH EFFICIENCY AND WORRY-FREE PERFORMANCE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Condensing Units & Air Handlers

WCH5**4. Product Specifications

PRODUCT SPECIFICATIONS

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

13 SEER CONDENSING UNITS & AIR HANDLERS

TECHNICAL SPECIFICATIONS B6VMMX

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

2 shp 13 lc 1 36 t - 1 a

R4H4. Product Specifications

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

16 SEER TWO-STAGE AIR CONDITIONERS

R4H4. Product Specifications

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT SERIES Up Flow / Horizontal

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

MAC N-407 Air-Cooled Chiller

4HP15L PRODUCT SPECIFICATIONS HIGH EFFICIENCY SPLIT HEAT PUMP SYSTEM UP TO 15 SEER & 9.0 HSPF COILS COMPONENTS COMPRESSOR WARRANTY CABINET DESIGN

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

MACH N-407 Heat Pump Air-Cooled Chiller

CONDENSING UNITS. Equipped with the Award Winning Comfort Control System UARL- JEZ. Four Models

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

RSG16**S1M. Split System Air Conditioner 16 SEER

AND WORRY-FREE PERFORMANCE

13 SEER CONDENSING UNITS

Table of Contents AIR CONDITIONING EQUIPMENT

Commercial High-Efficiency Condensing Units

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

14 AC x

13 GEP A L P - 1 A

AND WORRY-FREE PERFORMANCE

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Split System Cooling Product & Performance Data

Product Data. Side Discharge AC Models 4TTL6018A1000A 4TTL6024A1000A 4TTL6030A1000A 4TTL6036A1000A 4TTL6042A1000A 4TTL6048A1000A 4TTL6060A1000A

N4H4. Product Specifications

Advance Release September 2009

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

T S A 048 S 4 N 4 1 T

Indoor Air Handlers with Compressors MVS and MVW

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

TECHNICAL SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

Product Data. 50EES--ZP (50Hz) Single Package Air Conditioners 3-5 Nominal Tons

SKYPAK II, 3 Ton Series, gives you a

AND WORRY-FREE PERFORMANCE

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

PRODUCT SPECIFICATIONS

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

13 SEER HEAT PUMPS. Featuring Earth-Friendly R-410A Refrigerant 13PJL SERIES. Features Coils constructed with copper tubing and enhanced aluminum

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

Split System Heat Pump Product Data

RGE 13 A T - 1 A

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

HEAT EXCHANGER Aluminized serpentine clamshell heat exchanger provides corrosion resistance for longer life and efficient heat transfer.

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

PAJ3. Product Specifications

Transcription:

TECHNICAL SPECIFICATIONS Model DS4BD Series M120 Product Line High Efficiency R-410A Air Conditioner 13+ SEER 1.5-5 Ton Capacity

12 YEAR ALL PARTS WARRANTY This product offers a 1 Year Dependability Promise to replace the unit if the compressor fails in the first year of operation, to the original owner. All split system products must be installed with a matched indoor air handler or indoor coil to qualify. Product registration required for 12-year All Parts Warranty and Dependability Promise within a limited period of time after the installation. See current warranty document for details. This can be viewed at www.maytaghvac.com or ask your sales representative. Maytag now offers the choice of an air conditioner that uses a more efficient and environmentally friendly refrigerant designated R-410A. The DS4BD Series of air conditioners offers exceptional performance. The unit, when combined with our engineered coils or air handlers, offers a full line of quality, split system cooling equipment. Features and Benefits SmartCool TM 410 TM Refrigerant (R-410A) Earth friendly non-ozone depleting refrigerant. Designed using galvanized steel with a polyester urethane coat finish. The 950 hour salt spray finish resists corrosion 50% better than comparable units. Copper Tube / Aluminum Fin Coils Both indoor and outdoor coils are designed to optimize heat transfer, minimize size and cost, and increase durability and reliability. Permanently Lubricated Motor A heavy duty PSC motor for long lasting reliability and quiet operation. Requires no maintenance and is completely protected from rain and snow. Full Port Service Valves Full port brass ball valves provide low pressure drop and ease of service. The valves are actuated by 1/4 turn full open to full close. Steel Guard TM Durable metal guard protects the coil from yard hazards and extreme weather. Removable Top Grille Assembly Allows ease of service from the top without disconnecting fan motor leads. High Pressure Switch Protects against abnormally high system pressures. Auto-reset feature prevents nuisance service visits. Liquid Line Filter Drier Included with unit, field installed. One Piece Top/Orifice Designed for maximum airflow and quiet operation. 2-1/2 Pedestal Base The sturdy base keeps the bottom of the coil out of harms way. Secondly, the base has weep holes along the edge to allow the water from rain to flow away from the unit. Easy Compressor and Control Access Designed to make servicing easier for the contractor, access panels are provided to all controls and the compressor from the side of the unit. 3

DIMENSIONS/OUTDOOR SECTION 13 SEER High Efficiency Single Phase DS4BD 018K 024K 030K 036K 042K 048K 060K H 34 1/2 30 1/2 34 1/2 38 1/2 38 1/2 42 1/2 42 1/2 W 22 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 D 22 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 30 1/2 Air Discharge Allow Adequate Clearance for Airflow D W H IDENTIFICATION CODE EX: DS4BD-036K D S 4 B D - 036 K D = Steel Guard TM Product Identifier Nominal Capacity (000) BTU Electrical Code K = 208/230-60-1 S = Air Conditioner Design Series BD = Braze 13 SEER 4

PHYSICAL AND ELECTRICAL SPECIFICATIONS / OUTDOOR UNITS 13 SEER High Efficiency Single Phase Model Number DS4BD- Electrical Data Condenser Data Volts-Cycles-Phase (1) Total Amps Delay Fuse Max. (2) Min. Circuit Ampacity Coil Fan Motor Fan Blade Compressor Data Refrigerant suction line O.D.(all length of liquid line are 3/8" O.D.) Refrigerant charge (R-410A) in ounces for outdoor unit, indoor unit and 15' (1) Operating Voltage Range: 187v min. 253v max. (2) HACR Type Circuit Breakers may be used. (3) Requires 7/8" to 3/4" reducer from line to unit. (4) Requires 7/8" to 1-1/8" reducer from line to unit. 018K 024K 030K 036K 042K 048K 060K 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 208/230-60-1 9.3 14.44 15.08 17.64 19.32 23.16 27.64 20 30 30 35 40 45 50 11.54 17.8 18.6 21.8 23.8 28.6 34.2 Area 13.2 17.5 20.3 22.8 22.8 25.4 25.4 Rows-FPI 1-22 1-22 1-22 1-22 1-22 1-22 2-16 Tube Dia 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. 3/8" O.D. Type PSC PSC PSC PSC PSC PSC PSC Amps 0.34 1 1 1 1.4 1.4 1.4 Watts-HP 0.25 0.25 0.25 0.25 0.25 0.25 0.25 Dia-# Blades 18"- 3 24"- 2 24"- 2 24"- 2 24"- 2 24"- 2 24"- 2 SCFM 2600 3000 3200 3300 3600 3800 3800 RLA 10 15 15.7 18.6 20 24.3 29.3 LRA 48 58.3 73 77 112 117 134 0-24 ft. 3/4" 3/4" 3/4" 3/4" 7/8" 7/8" 7/8" 25-39 ft. 3/4" 3/4" 3/4" 7/8" (3) 7/8" 7/8" 1-1/8" (4) 40-75 ft. 3/4" 3/4" 3/4" 7/8" (3) 7/8" 7/8" 1-1/8" (4) lineset. 83 96 117 125 144 149 248 Weight Net 157 166 171 176 176 181 223 Approximate (lbs.) Ship 165 175 180 185 185 190 235 COPPER WIRE SIZE AWG (1% Voltage Drop) Supply Wire Length-Feet Supply Circuit 200 150 100 50 Ampacity 6 8 10 14 15 4 6 8 12 20 4 6 8 10 25 4 4 6 10 30 3 4 6 8 35 3 4 6 8 40 2 3 4 6 45 2 3 4 6 50 Wire Size based on N.E.C. for 60 type copper conductors. 5

SYSTEM COOLING CAPACITIES 13 SEER High Efficiency Single Phase Outdoor Unit Required Model Number DS4BD Indoor Unit BTUH SEER EER SCFM Orifice (1) 018K C5B(A,H)-024(U,C)-A 18000 13 11.6 550 0.049 024K C5B(A,H)-024(U,C)-(A,B) 24000 13 12.3 800 0.055 030K C5B(A,H)-030(U,C)-(A,B) 30000 13 12.3 950 0.062 036K C5B(A,H)-036(U,C)-B 34400 13 12.3 1100 0.069 042K C5B(A,H)-042(U,C)-B 41600 13 12.1 1300 0.073 048K C5B(A,H)-048(U,C)-(B,C) 48000 13 12.1 1400 0.082 060K C5B(A,H)-060(U,C)-C 60000 13 11.5 1700 0.087 Outdoor Unit Required Model Number DS4BD Indoor Unit BTUH SEER EER SCFM Orifice (1) 018K PAH2BM024K,A 18,000 13 11.6 550 0.049 024K PAH2BM024K,A 24000 13 12.3 800 0.055 024K PAH2BM024K,B 24000 13 12.3 800 0.055 030K PAH2BM030K,A 30000 13 12.3 950 0.062 030K PAH2BM030K,B 30000 13 12.3 950 0.062 036K PAH2BM036K,B 34400 13 12.3 1100 0.069 042K PAH2BM042K,B 41000 13 12.1 1300 0.073 048K PAH2BM048K,C 48000 13 12.1 1400 0.082 060K PAH2BM060K,C 60000 13 11.5 1700 0.087 1 Orifice supplied with outdoor unit. See current ARI Directory for certified combinations and ratings. All ratings are with time delay relay. 14 SEER High Efficiency Single Phase Outdoor Unit Required Model Number DS4BD Indoor Unit BTUH SEER EER SCFM Orifice (1) 018K C5B(A,H)-024(C,U)-B+VSB-B 18400 14 12.8 550 0.049 024K C5B(A,H)-024(C,U)-B+VSB-B 24400 14 13.8 800 0.055 030K C5B(A,H)-030(C,U)-B+VSB-B 30400 14 13.6 950 0.062 036K C5B(A,H)-036(C,U)-B+VSB-B 35000 14 13.4 1100 0.069 042K C5B(A,H)-048(C,U)-C+VSB-C 42500 14 13.4 1300 0.073 048K C5B(A,H)-048(C,U)-C+VSB-C 48500 14 13.1 1400 0.082 060K C5B(A,H)-060(C,U)-C+VSB-C 60500 14 12.1 1700 0.087 Outdoor Unit Required Model Number DS4BD Indoor Unit BTUH SEER EER SCFM Orifice (1) 018K PAH2VM024K-B 18400 14 12.8 550 0.049 024K PAH2VM024K-B 24400 14 13.8 800 0.055 030K PAH2VM030K-B 30400 14 13.6 950 0.062 036K PAH2VM036K-B 35000 14 13.4 1100 0.069 042K PAH2VM048K-C 42500 14 13.4 1300 0.073 048K PAH2VM048K-C 48500 14 13.1 1400 0.082 060K PAH2VM060K-C 60500 14 12.1 1700 0.087 1 Orifice supplied with outdoor unit. See current ARI Directory for certified combinations and ratings. All ratings are with time delay relay. 6

ACCESSORIES - CONDENSING UNIT Start Assist Kit - 912933 Provides additional starting torque for the compressor motor when operating with low line voltage or high operating temperatures.

CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Specifications and illustrations subject to change without notice and without incurring obligations. Maytag is a registered trademark of the Maytag Corporation and is used under license. 048C-0207 (Replaces 048C-0306) Printed in U.S.A. (02/07)