DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

Similar documents
SECTION REFRIGERANT PIPING

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

Ratio Architects, Inc. Section Refrigerant Piping

SECTION (15530) - REFRIGERANT PIPING

REFRIGERANT PIPING SYSTEM

PROJ. NO SECTION REFRIGERANT PIPING

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SECTION REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING

DESIGN STANDARDS SECTION 15600

REFRIGERANT PIPING

SECTION AIR COOLED WATER CHILLERS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

.2 Section Waste Management and Disposal.

SECTION ROTARY-SCREW WATER CHILLERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

SECTION VARIABLE REFRIGERANT VOLUME (VRV) HVAC SYSTEM

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SECTION REFRIGERANT PIPING SYSTEMS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

SECTION PACKAGE AIR COOLED WATER CHILLER PART 1 GENERAL 1.01 SECTION INCLUDES. A. Chiller package. B. Charge of refrigerant and oil.

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

SECTION WATER-SOURCE UNITARY HEAT PUMPS

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

RTU. Roof Top Units 8 30 Ton. Maxi-Kool.

EMI ENGINEERING SUBMITTAL

MAC N-407 Air-Cooled Chiller

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

MACH N-407 Heat Pump Air-Cooled Chiller

EMI ENGINEERING SUBMITTAL

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

MAXIMUM SERIES. Maximum Series portable chillers can be used on a variety of process applications that require 20 F to 70 F chilled water.

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

30GT FLOTRONIC AIR-COOLED CHILLERS

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

1.1 This section applies to air handling units for HVAC Systems.

Fujitsu Condenser Model Number: AOU18RLXFZ, AOU18RLXFZH, AOU24RLXFZ, AOU24RLXFZH, AOU36RLXFZ, AOU36RLXFZ1, AOU48RLXFZ1.

SECTION AIR COILS

SECTION VARIABLE REFRIGERANT FLOW SYSTEM

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

AIR COOLED PACKAGED CHILLER

1.3 QUALITY ASSURANCE A. Perform design and installation in accordance with applicable codes.

PACKAGE AIR CONDITIONER

Product Chillers A P P L I C AT I O N S

Air cooled industrial chillers

Direct Fired Units w/ Packaged Cooling

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

SECTION AIR-SOURCE UNITARY HEAT PUMPS

48TM GAS HEATING/ELECTRIC COOLING UNITS

50TM COMBINATION HEATING/COOLING UNITS

30GN FLOTRONIC II AIR-COOLED CHILLERS

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

SECTION WATER-SOURCE UNITARY HEAT PUMPS

SECTION DOMESTIC WATER PIPING SPECIALTIES

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

A. This Section includes the following domestic water piping specialties:

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

TOSHIBA AIR CONDITIONING

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

Owner s Manual Therma-Stor II Heat Recovery System

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

SpaceKeeper Console (SKC)

SECTION PLUMBING EQUIPMENT

The ultimate fresh air solution.

Commercial High-Efficiency Condensing Units

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

Design and Construction Standards SECTION PLUMBING EQUIPMENT

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

MAC-120HE-03 Air-Cooled Chiller

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Transcription:

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6 1.1. REFERENCE STANDARDS 1.2. GENERAL 1.1.1. The units shall be listed by Electrical Testing Laboratories (ETL) and bear the ETL label. 1.1.2. The units shall conform to ANSI/UL STD. 1995 and certified to CAN/CSA C22.2 No. 236-05 1.1.3. The units shall be rated in accordance with ARI Standard 210/240 and bear the ARI label. 1.2.1. Air-source type heat pump system allowing simultaneous cooling and heating. 1.2.2. System components 1.2.2.1. Outdoor condensing unit(s) 1.2.2.2. Indoor evaporator unit(s) 1.2.2.3. Controller 1.2.2.4. Interconnecting refrigerant piping 1.2.2.5. Condensate drainage 1.3. OUTDOOR CONDENSING UNIT 1.3.1. Refrigerant flash technology enables providing up to 100% of rated heating capacity at -18 O C (0 O F) in standard mode. 1.3.2. Operating Temperature Range 1.3.2.1. Cooling (Outdoor): -5 O C to 46 O C (23 O F to 115 O F) DB 1.3.2.2. Heating (Outdoor): -25 O C to 15 O C (-13 O C to 60 O F) DB 1.3.3. Modular design allowing multiple smaller capacity units to be piped together to form a large capacity system 1.3.4. Minimum outdoor temperature for simultaneous cooling and heating operation is - 20 O C (-4 O F) 1.3.5. Cabinet: 1.3.5.1. The casing shall be constructed from galvanized steel plate and finished with ivory colour (munsell 3Y 7.8/1.1) acrylic paint 1.3.5.2. The fan grille shall be of polypropylene (PP) plastic. 1.3.5.3. Built-in base pan heater to prevent ice in drain pan

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 2 of 6 1.3.6. Compressor: 1.3.7. Fan: 1.3.8. Coil: 1.3.6.1. The compressor shall be hermetic scroll type with variable compressor speed inverter technology. 1.3.6.2. The compressor crankcase shall be heated by intermittent low speed compressor motor rotation. 1.3.6.3. The outdoor unit shall have high pressure and over current protective device. 1.3.6.4. The compressor shall have 2 phase flash injection technology 1.3.7.1. The unit shall be furnished with DC fan motors for direct drive propeller fan. 1.3.7.2. The motor bearings shall be permanently lubricated 1.3.7.3. The fan shall be mounted in front of the coil, pulling air across it from the rear and dispelling it through the front. 1.3.8.1. The condenser coil shall be of copper tubing with flat aluminum fins. 1.3.8.2. The coil shall be protected with an integral metal guard. 1.4. INDOOR EVAPORATOR UNIT(S) 1.4.1. One air source condensing unit supports up to 50 indoor units. The indoor unit shall be factory assembled, wired and tested. 1.4.2. Contained within the unit shall be all factory wiring, internal piping, control circuit board and fan motor. 1.4.3. Indoor unit shall have capabilities to be installed at a maximum height of 100ft. (30m) above or below the outdoor unit. 1.4.4. Total capacity of connected indoor units can be 50-150% of system capacity 1.4.5. Return air shall be filtered by means of an easily removed washable filter with a MERV rating of 1-4. 1.4.6. The evaporator coil shall be of copper tubes construction with aluminum strake precoated fins on copper tubing. All tube joints shall be brazed with phoscopper and silver alloy. 1.4.7. A condensate pan and drain shall be provided under the coil. All units equipped with condensate drain pump capable of up to 550 mm (22 ) of lift

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 3 of 6 1.4.8. Exposed Evaporators 1.4.8.1. Ceiling Cassette 4 Way Air Flow (3/4 ton 3 ton cooling capacity) 1.4.8.2. Ceiling Cassette 2 Way Air Flow (1/2 ton 2 ton cooling capacity) 1.4.8.3. Ceiling Cassette 1 way Air Flow (1/2 ton 2 ton cooling capacity) 1.4.8.4. Wall Hung (1/2 ton 3 ton cooling capacity) 1.4.8.5. Floor Mounted (1/2 ton - 2 ton cooling capacity) 1.4.9. Concealed Evaporators 1.5. CONTROLLER 1.4.9.1. Low Static - up to 50 Pa (1/2 ton 2 ton cooling capacity) 1.4.9.2. Medium Static up to 130 Pa (1/2 ton 4 ton cooling capacity) 1.4.9.3. High Static - up to 200 Pa (1 ton 8 ton cooling capacity) 1.5.1. Controller allows monitoring and control of up to 50 indoor evaporator units. 1.5.2. The unit shall have a wired controller with micro processor controls to perform input functions necessary to operate the system. There shall be a multi-language large DOT liquid crystal display wired controller. 1.5.3. The controller shall have a built in room temperature sensor. 1.5.4. The microprocessor control signal between the indoor and outdoor unit shall be incorporated with the indoor unit s electric supply requiring a minimum of 4 wire (3+gnd.) 14AWG cable. 1.5.5. The system shall be capable of automatic restart when power is restored after interruption. 1.5.6. The wired controller shall provide 7 day programmable time schedule with temperature set back and system ON/OFF operation. 1.5.7. The controller shall have auto change over between heating and cooling modes. 1.5.8. The controller shall provide system error diagnostic and operation data. 1.5.9. The wired controller shall have built in lead lag control (operation rotation between two systems, backup operation on failure of working system) between two systems. 1.5.10. The system shall have the option to be integrated and controlled by BMS (LonWorks, BacNet) 1.5.11. The system shall provide status and error output signals

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 4 of 6 1.5.12. The system shall have remote (control from remote location) ON/OFF control 1.6. REFRIGERANT PIPING 1.6.1. Copper refrigerant tube, ASTM B280, cleaned, dehydrated and sealed, marked ACR on hard temper straight lengths. Coils shall be tagged ASTM B280 by the manufacturer. 1.6.2. Soldering 1.6.2.1. Solder joints: Wrought copper fittings, ANSI B16.22. 1.6.2.2. Solder, refrigerant tubing: Cadmium free, AWS A5.8, 45 percent silver brazing alloy, Class Bag-5. 1.6.2.3. Solder, water and drain: 95-5 tin-antimony, ASTM B32 (95TA). 1.6.3. Refrigeration Valves: 1.6.3.1. Stop Valves: Brass or bronze alloy, packless, or packed type with gas tight cap, frost proof, backseating. 1.6.3.2. Pressure Relief Valves: Forged brass with nonferrous, corrosion resistant internal working parts of high strength, cast iron bodies conforming to ASTM A126, Grade B. Set valves in accordance with ASHRAE Standard 15. 1.6.3.3. Solenoid Valves: ARI 760, UL-listed, two-position, direct acting or pilotoperated, moisture and vapor-proof type of corrosion resisting materials, designed for intended service, and solder-end connections. Fitted with suitable NEMA 250 enclosure of type required by location. 1.6.3.4. Thermostatic Expansion Valves: Brass body with stainless-steel or noncorrosive non ferrous internal parts, diaphragm and spring-loaded (directoperated) type with sensing bulb and distributor having side connection for hot-gas bypass and external equalizer. Size and operating characteristics as recommended by manufacturer of evaporator and factory set for superheat requirements. Solder-end connections. Testing and rating in accordance with ASHRAE Standard 17. 1.6.3.5. Check Valves: Brass or bronze alloy with swing or lift type, with tight closing resilient seals for silent operation; designed for low pressure drop, and with solder-end connections. Direction of flow shall be legibly and permanently indicated on the valve body.

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 5 of 6 1.6.4. Refrigeration Accessories 1.6.4.1. Strainers: Designed to permit removing screen without removing strainer from piping system, and provided with screens 80 to 100 mesh in liquid lines up to 30 mm (1-1/8 inch), 60 mesh in liquid lines over 30 mm (1-1/8 inch), and 40 mesh in suction lines. Provide strainers in liquid line serving each thermostatic expansion valve, and in suction line serving each refrigerant compressor not equipped with integral strainer. 1.6.4.2. Refrigerant Moisture/Liquid Indicators: Double-ported type having heavy sight glasses sealed into forged bronze body and incorporating means of indicating refrigerant charge and moisture indication. Provide screwed brass seal caps. 1.6.4.3. Refrigerant Filter-Dryers: ULC listed, angle or in-line type, as shown on drawings. Conform to ASHRAE Standard 63. Heavy gage steel shell protected with corrosion-resistant paint; perforated baffle plates to prevent desiccant bypass. Size as recommended by manufacturer for service and capacity of system with connection not less than the line size in which installed. Filter driers with replaceable filters shall be furnished with one spare element of each type and size. 1.6.4.4. Flexible Metal Hose: Seamless bronze corrugated hose, covered with bronze wire braid, with standard copper tube ends. 1.6.4.5. Oil Separators: Provide for condensing units, where determined as necessary by the equipment manufacturer. All welded steel construction with capacity to eliminate a minimum of 95 percent of the oil from the hot gas flowing through it. Provide manufacturer's published ratings for minimum and maximum refrigeration tonnage corresponding to this oil separating efficiency. Conform to ASHRAE Standard 69. Separator shall be equipped with a float valve to prevent return of the hot gas to crankcase, and shall have isolating stop valves so it can be opened and services without pumping out any other part of the system. ASME construction or ULC listed. 1.7. CONDENSATE DRAINAGE LOOP 1.7.1. Connect all evaporators to the condensate drainage loop. Direct drainage to open-gap funnel floor drain, in accordance with code requirements. 1.7.2. Insulate all horizontal sections of the condensate drainage loop

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 6 of 6 1.7.3. Gravity Drainage Sections 1.7.3.1. Copper piping, Type DWV to: 1.7.3.2. ASTM B306-81 for copper tube. 1.7.3.3. CSA B158.1-1976 for cast brass fittings. 1.7.3.4. ANSI B16.29-1973 for wrought copper fittings. 1.7.3.5. Solder: tin-lead, 50:50, to ASTM B32-76, type 50A. 1.7.3.6. ASTM B88-83. 1.7.4. Pumped Drainage Sections: 1.7.4.1. Pipe: Copper tube, ASTM B88, Type K or L, drawn. 1.7.5. Fittings for Copper Tube: 1.7.5.1. Wrought copper or bronze castings conforming to ANSI B16.18 and B16.22. Unions shall be bronze, Mss SP-72, SP-110. Solder or braze joints. 1.7.5.2. Adapters: Provide adapters for joining screwed pipe to copper tubing. 1.7.5.3. Solder: ASTM B32 Composition Sb5. Provide non-corrosive flux.