E2K-L. Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid. Liquid Level Sensor. Ordering Information

Similar documents
Ultrasonic Reflective Sensor

onlinecomponents.com

Model Number Structure

Appearance and sensing characteristic Specification (temperature range) Model 10 to 70 C ES1B. 2 mm 20 mm 40 mm 60 mm. 40 dia. 60 dia.

Scale 0: 10 k Scale 50: 10 k (see note 2)

Ultrasonic Proximity Sensor

Ultrasonic Reflective Sensor

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Original instructions Sense7-series Non-contact coded safety switch

Original instructions JSNY7 Magnetic switch

Original instructions INCA-1 Emergency stop for enclosure installation INCA-1S Safety stop for enclosure installation

ES2-HB-N. Ordering Information. Specifications. Temperature/Humidity Sensor ES2-THB-N. Humidity Sensor

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

D6T. Contactless measurement creating energy-efficient and comfortable living spaces. MEMS Thermal Sensors

Annuciator Logic Controllers

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

Ultrasonic Proximity Sensor

E3M-V. Mark Sensor. Applications

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Current monitoring relay, overcurrent, undercurrent and current window. MCU024R2, MCU230R2

E3FA PHOTOELECTRIC SENSORS

E3FA/E3RA/E3FB/E3RB. Application specific models. Limited-reflective types suitable for detecting transparant film to shiny, mirror film.

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

E3FA PHOTOELECTRIC SENSORS

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 13 Page 1 of 7 Publish Date May 29, 2018

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

HIH-4030/31 Series Humidity Sensors

HIH-4602-L Series Humidity Sensors

Room Humidity/Temp Sensor

2. Contact form 6: 1c (SPDT) Load voltage (peak value) quantity Fully Sealed 1c (SPDT) 5 VDC 5 VDC 60 V 400 ma 130 ma G3VM-66M 50 pcs/tube

enproteko.com Specifications Ratings Item voltage to 24 VAC 5/6 Hz 24 VAC 5/6 Hz or 24 VDC Allowable voltage Characteristics 85% to 11% of power suppl

Duct Humidity/Temp Sensor

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

FEATURES AND BENEFITS

TILT SENSOR SWITCH. Item No. RBS Description Ball-Contact Version 15 Page 1 of 7 Publish Date May 13, 2018

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable


DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

KILOVAC K1K High-Voltage Contactor

HIH-5030/5031 Series Low Voltage Humidity Sensors

HOA6480 Series Barcode Sensor Infrared Products

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

MICRO SWITCH NT Series

Model Number Structure

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

MICRO SWITCH NT Series

Transparent Object (PET Bottle) Detection Compact Photoelectric Sensor

Motor Condition Monitoring Device K6CM

Potential Applications

HIH-4010/4020/4021 Series Humidity Sensors

FSS-SMT Series. Low Profile Force Sensor

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

3NT SERIES FIXED TEMPERATURE THERMOSTATS Introduction

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

MODEL 4000A & 4001A ACCELEROMETER

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

E5CN-FR Limit Controller USER S MANUAL

Outside Air Humidity & Temperature Sensor

HIH-4000 Series Humidity Sensors

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

SAVE THESE INSTRUCTIONS

E3FA PHOTOELECTRIC SENSORS

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

USER MANUAL SAVE THESE INSTRUCTIONS

SKORPION Process Air Heater

430128A. B-Series Flow Meter SIL Safety Manual

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

EQUIPMENT Operation Manual

HIH-4602 A & C Series.

Air Pump Up to 800 gallons

NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Duct Temperature Sensors

1022 R/T Remote Monitor

Micropower Omnipolar Digital Hall-Effect Sensor ICs

MODEL 834M1 ACCELEROMETER

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Compact, Photoelectric Sensor with Built-in Amplifier and Teaching Function. Mark Sensor with Stainless Steel Housing

OSRAM 8/12/00 SYLVANIA Process Heat FOR SAFETY AND LONG HEATER LIFE, CAREFULLY READ THIS MANUAL BEFORE USE.

Sentry LIQUID LEVEL ALARM MODEL 100 OPERATING MANUAL.

Model Number Structure. Floatless Level Switch (Basic Type)

WDB2 Series Bearing Temperature Sensor

Pressurized Filter Up to 1250 gallons

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Model OEM-2 INSTRUCTIONS FOR USE

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

User s Manual and Operating Instructions

Item Symbol Rating Unit Power supply V CC 12.0 VDC Output voltage V OUT 3.0 VDC

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

NTC THERMISTOR SENSOR PERFORMANCE

INTELLICRISP WAFFLE MAKER INSTRUCTION MANUAL MODEL: CKCLWF1. Calphalon_WaffleMaker_IB_SPEC_DarkGrey_CKCLWF1_19EM1.indd 1 1/25/19 09:30

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

IN020 Rev F Page 1 of 8

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

Transcription:

Liquid Level Sensor EK-L CSM_EK-L_DS_E_4_ Liquid Level Sensor That Is Unaffected by the Color of the Pipe or Liquid Mount to bypass pipes. Fit a wide range of pipe diameters: 8 to 11 mm or 1 to mm Built-in Amplifiers to save space. Be sure to read Safety Precautions on page 3. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Sensors [Refer to Dimensions on page 4.] Sensing method Applicable pipe diameters Appearance Output configuration/operation mode Model 8 to 11 mm M Capacitive NPN open-collector output NO 1 to mm EK-LMC1 M 1

Ratings and Specifications EK-L Item Model EK-LMC1 Materials Non-metal Applicable pipes Size Diameter Thickness Detectable object Liquid * Repeat accuracy Differential travel (Reference value, varies with pipe size and liquid.) Power supply voltage (operating voltage range) Current consumption Control output Sensing liquid position Indicators Load current Ambient temperature range Ambient humidity range Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection * Stable detection will not be possible in the following cases. Confirm detection capability with the Sensor installed before actual application. 1. If the specific inductive capacity or the specific electric conductivity of the liquid is too low, the liquid position may not be detected since this sensor is a capacitive sensor.. If the quantity of liquid is too low or the change in quantity is too low in comparison to the change in liquid level because the pipe is too thin or the walls of the pipe are too thick 3. If there is a viscous film on the inner pipe wall, large quantities of foam or air bubbles, or excessive buildup of dirt on the inner pipe wall Engineering Data (Reference Value) 8 to 11 mm 1 to mm 1 mm max. 1.5 mm max. ±0. mm max. 0. to 5 mm 0.3 to 3 mm 1 to 4 VDC (10.8 to 30 VDC), ripple (p-p): 10% max. 1 ma max. 100 ma max. Residual voltage 1 V max. (Load current: 100 ma, Cable length: m) Indented mark position (For details, refer to Technical Guide (Operational version).) Detection indicator (orange) Operating: 0 to 55 C (with no icing or condensation), Storage: 10 to 5 C (with no icing or condensation) Operating/Storage: 5% to 85% (with no condensation) ±4 mm of detection level at 3 C in the temperature range of 0 to 55 C (with pure water or 0% saline solution) (± mm for with pure water and a pipe diameter of 8 mm) ±0.5 mm of detection level at the rated voltage in rated voltage ±10% range 50 MΩ min. (at 500 VDC) between current-carrying parts and case 500 VAC, 50/0 Hz for 1 min between current-carrying parts and case Destruction: 10 to 55 Hz, 1.5-mm double amplitude for hours each in X, Y, and Z directions Destruction: 500 m/s 3 times each in X, Y, and Z directions IP (IEC) Connection method Pre-wired Models (Standard cable length: m) Weight (packed state) Materials Accessories Case, Cover Cable clamp Approx. 70 g Heat-resistant ABS NBR Influence of Temperature and Sensing Liquid Level EK-LMC1 Two bands, Four slip-proof tubes, Instruction manual Change in sensing liquid level (mm) 4 0-10 Pipe diameter: 11, Liquid: Pure water Pipe diameter: 11, Liquid: Saline solution Pipe diameter: 8, Liquid: Pure water Pipe diameter: 8, Liquid: Saline solution 0 10 0 30 40 50 0 Temperature ( C) Change in sensing liquid level (mm) 4 0 10 Pipe diameter:, Liquid: Pure water Pipe diameter:, Liquid: Saline solution Pipe diameter: 1, Liquid: Pure water Pipe diameter: 1, Liquid: Saline solution 0 10 0 30 40 50 0 Temperature ( C) 4 4

I/O Circuit Diagrams EK-L Operation mode Model Timing chart Output circuit Brown +V NO EK-LMC1 Liquid level Load (between brown and black leads) Detection indicator (orange) Present None Operate Reset ON OFF Main circuit Black * Blue Load 0 V Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. Design Influence of Surrounding Objects When mounting the Sensor, maintain at least the distances in the following diagrams from surrounding metal objects or other conductors to prevent the Sensor from being affected by objects other than the sensing object. Pipe Sensor Mutual Interference * Load current: 100 ma max. (Unit: mm) Distance Model D * E F 5 10 10 EK-LMC1 30 * Also, always adjust the bottom Sensor first because adjusting the bottom Sensor may affect the detection level of the top Sensor. Mounting Mounting Mount the Sensor securely to the pipe using the enclosed two bands and four slip-proof tubes (two tubes used for each band) as shown in the following diagram. When mounting the Sensor, be sure the entire Sensor is tight against the pipe along the sensing surface. Pipe A Face-to-face Sensor Detection indicator Sensitivity adjuster B Liquid level C Set position (indented mark) On One Side Influence of Surrounding Objects On Both Sides (Unit: mm) Bands Slip-proof tubes Side View Front View Distance A B C Model 5 45 5 EK-LMC1 0 40 Pipe Sensor Mutual Interference When installing Sensors in series, in parallel, or face-to-face, ensure that the minimum distances given in the following table are maintained. Bands Slip-proof tubes Top View D In Series E In Parallel F Face-to-face 3

EK-L Wiring Power Supply If the load and Sensor are connected to different power supplies, always turn ON the Sensor power first. Switching noise can cause operating mistakes if a commercial switching regulator is used. When using a switching regulator, always ground the frame ground terminal and the ground terminal. Operating Environment Ambient Atmosphere Although the Sensor is water resistance, it is a capacitive sensor and should not be used where it will come into direct contact with liquids, such as water or cutting oil. The life of the Sensor will be shorten by rapid changes in temperature even within the ambient operating temperature range. Do not use the Sensor in locations subject to rapid temperature changes. Miscellaneous Drift will occur when the power supply is turned ON. If the specific inductive capacity of the sensing liquid is low, the detection level may increase by to 3 mm during the 0 minutes required from the time the power supply is turned ON until operation stabilizes. Dimensions (Unit: mm) Tolerance class IT1 applies to dimensions in this data sheet unless otherwise specified. 0 5 R.5 R17.5 4 11 Mounting holes 1.5 Detection indicator (orange) 43 41 33 4 5 4.5 Sensing surface *.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.14 mm, Insulator diameter: 0.9 mm), Standard length: m.5 3.5 1 Sensitivity adjuster EK-LMC1 0 5 R13 R17.5 33 11 Mounting holes 1.5 Detection indicator (orange) 4.5 Sensitivity adjuster 34 3 4 3 1 Sensing surface 3.5 *.9-dia. vinyl-insulated round cable with 3 conductors (Conductor cross section: 0.14 mm, Insulator diameter: 0.9 mm), Standard length: m.5 4

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 01.8 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 01 All Right Reserved.

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Omron: EK-LMC1