WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Similar documents
WALL-HUNG SYSTEM & UNVENTED CYLINDERS

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

For latest prices and delivery to your door visit MyTub Ltd

WALL-HUNG COMBINATION

DOMESTIC HOT WATER AND CENTRAL HEATING SYSTEM

WALL-HUNG COMBINATION

Amptec. Electric flow boiler

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

Unvented Hot Water Storage Cylinders Installation and Maintenance Instruction Manual

thermocompact High performance system boiler range

Unvented water heating

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Cistern-fed water heating

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

Hotflo. Unvented point of use hot water

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Exceeding the Standard

Exceeding the Standard

Water Heating Systems

Combined electric boiler and domestic hot water store

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

Sirius FS. Working towards a cleaner future

Instructions for Use Installation and Servicing

DOMESTIC BOILER RANGE & ACCESSORIES.

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

UNVENTED WATER HEATERS. Water Heater Display Stand

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Stainless Steel Unvented Cylinders

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

UNVENTED STAINLESS STEEL CYLINDERS

Unvented Hot Water Systems for the Professionals

Unvented water heater

Hand Hygiene. September 2015 EV Instantaneous Handwash

Unvented Hot Water Storage Cylinders

Vented systems explained Performance without compromise Vented System (Gravity Fed) Positive Head Systems

2015 PRODUCT RANGE GUIDE

Water Heating UK 14 th May 2016

Unvented Water Heating. Zircon

=Classic range= Classic range technologies. Magnesium anode. Sheathed heating element

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

the electric heating company ELECTRIC BOILER HANDBOOK

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

MICROGENUS HE WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILER. minimum space HIGH EFFICIENCY

Multipoint Technical Data

POINT OF USE WATER HEATERS

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Megaflo eco Unvented hot water cylinders

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Redring Powerstream Electric Flow Boilers. Efficient, safe and convenient electric space and water heating

Gas Storage Water Heaters CONVENTIONAL FLUE FAN FLUED BALANCED FLUE DIRECT STORAGE TANKS

British Gas 330 High Efficiency Condensing Boiler Manual

unistor High performance unvented stainless steel cylinder range

MAINTENANCE AND SERVICE GUIDE

Multipoint. Unvented point of use hot water

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Miscellaneous. TMV3 Mixing Valves. TMV3 Thermostatic Mixing Valves. Specifications. Temperature Readout. Features include:

The iqe Boiler Range. Combination and System T Boilers.

CELT STAR C GAS-FIRED WATER HEATER. Category: I 2E+ Installation and Use Instructions. Contents : Description:

Water. Heating. Connect with the Best. Electric Showers Power Showers 324. Shower Pumps 324. Beverage Water Dispensers

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

User's Instructions. Alpha CB50

ecotec plus 937 Power store high efficiency combination boiler

Electric PRODUCT.GUIDE. Electrical Water Heaters and Cylinders suitable for a comprehensive range of hot water requirements.

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

VENTED CYLINDER RANGE

Where gas is not an option,

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

Sirius WH. Working towards a cleaner future

Installation and Commissioning Manual

Unvented water heaters

Hot Water Supply. Dr. Sam C M Hui Department of Mechanical Engineering The University of Hong Kong

unistor High performance unvented stainless steel cylinder range

Total Hot Water Solutions

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Furrows Business Park, Haybridge Road Wellington, Telford, Shropshire TF1 2FE

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

Performance on demand

Installation and Servicing Instructions. Alpha GasSaver GS-1

CUBEflow Thermal Store Tank

Installation & Technical Guide. Domestic & Commercial.

Contacts: Potterton. For latest prices and delivery to your door visit MyTub Ltd

KYROS INSTALLATION MANUAL KYROS. Digital Electric Water Heater Wall-hung Unvented

Unvented water heating

SOLAR HEATING SYSTEMS

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

turbomax plus High performance combination boiler range

Transcription:

WATER HEATERS Simplicity, performance, comfort... Hydraflo Unvented Cylinders 125 to 300 litres, directly or indirectly heated.

Unvented Hot Water Supply Systems Our unvented cylinders make life easier, with a wide range to suit most applications. United Kingdom practice for domestic hot water storage and supply systems was to have an open vent pipe from the hot water storage vessel back to the cistern. Simpler, unvented systems had been developed and used widely throughout the rest of Europe, and indeed the rest of the world. Since the 1985 Building Regulations and the new Model Water Byelaws of 1986, unvented systems have been permitted in the UK. Traditional open-vent system The MTS Group, owner of the Chaffoteaux & Maury brand name, is the leading world manufacturer of unvented water heating products with more than 50 years experience. Continuous research into new technology and design ensures that quality and reliability remain at a high standard. Every detail of water heater production is controlled by qualified personnel, using the latest technology, quality materials, and continuous testing throughout the production cycle. By applying such stringent conditions, the MTS Group has attained ISO 9001 Corporate Certification, joining a few elite companies within the EU to achieve this Award. These unvented products provide a versatile alternative to the traditional systems installed in the UK. Chaffoteaux & Maury offers a comprehensive range, both directly and indirectly heated, to suit most applications and can provide sizes from 125 to 300 litres capacity. Advantages of an unvented system Hot and cold water supply to all outlets at relatively high pressure. Unvented indirect system Drinking water at all cold water outlets, as every cold water outlet is fed directly from the mains water supply. Balanced hot and cold water supply pressures throughout the system - wider choice of taps and mixers. Good shower flow and force without the need for pumps. No cistern in the loft - no risk of water stagnation (and Legionella), no risk of frost damage to pipework and no noise of filling cisterns. Unvented direct system Lower insurance premiums due to the absence of stored water in the loft. Unvented systems comply with all current building regulations in the UK. Simpler plumbing system - less pipework, less time, less cost.

Unvented Cylinders Installation Flexibility Chaffoteaux & Maury Hydraflo unvented cylinders range from 125 litres to 300 litres in capacity. All are designed for maximum installation flexibility. Hydraflo cylinders up to 200 litres capacity are just 505 mm wide, with all plumbing and electrical connections from the front - ideal for installation in the tightest of spaces. 505 mm up to 200 litres High Quality Construction Hydraflo cylinders are manufactured in high-strength steel with a vitreous enamel coating for performance and durability. All are factory fitted with active magnesium anodes for extra protection. The cylinder tank of Hydraflo unvented cylinders is guaranteed for 5 years. Temperature and Pressure Relief Value All Hydraflo unvented cylinders are equipped with a temperature and pressure relief (T&P) valve. The T&P valve is factory fitted to all of the unvented cylinder ranges, conforming to requirements of BS 7206: 1990 and current Building Regulations. This valve prevents the stored water from exceeding 100 C in the event of the failure of the other safety devices. T&P valves on Hydraflo unvented cylinders are 1 /2 as standard, reducing the need for a 28mm discharge in most situations. Thermostat Hydraflo unvented cylinders are equipped with quality thermostats, which guarantee high performance and safety. Top Quality Heating Elements Hydraflo unvented cylinders are equipped with a manual reset thermal cut-out. This device overrides the main thermostat in the case of failure. Built with first grade materials to guarantee a long life, the elements incorporated in the Hydraflo range are all produced in-house at an ISO 9001 certified factory. Efficient Insulation, Low Power Consumption A high density, CFC free layer of thick polyurethane foam, guarantees Hydraflo unvented cylinders excellent insulation, whilst at the same time drastically cutting power consumption. Thermal Cut-Out Hydraflo unvented cylinders are equipped with a manual reset thermal cut-out. This device overrides the main thermostat in the case of failure.

Hydraflo Direct STD 125, 150, 210, 300 Floor standing direct unvented cylinders Quality steel tank, 12 bar pressure tested and exclusive vitreous enamel coating. CFC free polyurethane thermal insulation. Compact design - slimmest available on the market. All plumbing and electrical connections within a 90 angle. Magnesium anodes. Heating elements supplied with regulation thermostats and dual pole thermal cut-outs. Thermostats adjustable to 70 C. Factory fitted 1 /2 T&P relief valve. Unvented control kit supplied with cylinder at no additional cost. Simple installation. 5 year tank guarantee (2 year guarantee on electrical components) d Dimensions MODEL STD 125 STD 150 STD 210 STD 300 a mm 650 790 940 1215 b mm 755 915 1230 1555 c mm 995 1155 1475 1790 d mm 505 505 505 560 e mm 265 265 265 275 22 45 45 30 a e b c Technical Specification MODEL STD 125 STD 150 STD 210 STD 300 Capacity litres 125 150 200 300 Voltage V 240 240 240 240 Power kw 3+3 3+3 3+3 3+3 Reheat time* ( T= 50 C) minutes 150 175 240 350 Maximum temperature C 70 70 70 70 Heat loss (kwh in 24 h) 60 C 1.70 1.90 2.10 2.85 Typical application** A B C D *Based on single heating element **Typical application A: domestic usage <3 people (kitchen, shower) B: domestic usage 3/4 people (kitchen, bathroom + shower) C: domestic usage 4/5 people (kitchen, 2 bathrooms) D: domestic usage 5 people (kitchen, 2 bathrooms + shower) 5 YEAR GUARANTEE

f Hydraflo Indirect Floor standing indirect unvented cylinders Quality steel tank, 12 bar pressure tested and exclusive vitreous enamel coating. CFC free polyurethane thermal insulation. Compact design - slimmest available on the market (up to 200 litres). All plumbing and electrical connections within a 90 angle. Magnesium anodes. Heating element supplied with regulation thermostat and dual pole thermal cut-out. Cylinder thermostat with external regulation. Thermostats adjustable to 70 C. Unique coil design allows full quantity of water to be heated. Factory fitted 1 /2 T&P relief valve. STI 125, 150, 210, 300 Unvented control kit supplied with cylinder at no additional cost. e Simple installation. 5 year tank guarantee (2 year guarantee on electrical components) a g d b c 22 45 45 Dimensions MODEL STI 125 STI 150 STI 210 STI 300 a mm 650 790 940 1215 b mm 755 915 1230 1555 c mm 995 1155 1475 1790 d mm 625 765 765 815 e mm 505 505 505 560 f mm 265 265 265 275 g mm 225 225 225 255 Technical Specification MODEL STI 125 STI 150 STI 210 STI 300 Capacity litres 125 150 200 300 Indirect coil rating kw 20.5 26.7 26.7 26.7 Coil surface area m 2 0.75 0.90 0.90 0.90 Indirect reheat time* ( T= 50 C) minutes 18 22 26 40 Voltage V 240 240 240 240 Power kw 3 3 3 3 Immersion heater reheat time ( T= 50 C) minutes 150 175 240 350 Maximum temperature C 70 70 70 70 Heat loss (kwh in 24 h) 60 C 2.00 2.20 2.40 2.85 Typical application** A B C D *Primary circuit 80 C, 1 m 3 /h circulation **Typical application A: domestic usage 3/4 people (kitchen, bathroom + shower) B: domestic usage 4/5 people (kitchen, 2 bathrooms) C: domestic usage 5 people and above (kitchen, 2 bathrooms + shower) D: commercial use 5 YEAR GUARANTEE

Accessories Hydraflo Direct Control Pack STD 125-210 Control Pack STD 300 Hydraflo Indirect Control Pack STI 125-210 Control Pack STI 300 For the perfect installation All Chaffoteaux & Maury unvented cylinders are supplied complete with the appropriate control kit (included within cylinder price). Optional extra: Expansion vessel Wall Mounting Kit (12-18 litre vessels)

Britony System II/Plus Heating & Hot Water Flexibility Britony System II Boilers offer all the benefits of a sealed system boiler in conjunction with separate hot water storage. A low water content and responsive copper heat exchanger, make Chaffoteaux s wall hung system boilers highly efficient. A thermistor accurately controls the hot water flow temperature and the electronic ignition helps to minimise gas consumption. These room sealed, fan assisted balanced flue appliances are perfect for both new and refurbishment applications. A modern design and compact dimensions offer stylish compatibility with fitted kitchen furniture. Designed for simplicity Quick and easy to install. Britony System II boilers are easy to service, with front access to all components after removing the lightweight, one-piece case. All essential boiler operations are incorporated in a single, easy to operate control panel. Choice of models Britony System II: perfect for new or existing applications and replacements, using the special piping adaptor kit. Britony System II Plus: supplied with a 3-way diverter valve for priority hot water connection to Hydraflo unvented cylinders. Technical Specification MODEL SYSTEM II 80 SYSTEM II PLUS 80 SYSTEM II 100 SYSTEM II PLUS 100 HEAT INPUT MAX kw - Btu/h 28.7-98,000 28.7-98,000 34.6-117,900 34.6-117,900 HEAT INPUT MIN kw - Btu/h 11.7-39,900 11.7-39,900 15.4-52,500 15.4-52,500 HEAT OUTPUT MAX kw - Btu/h 24-81,900 24-81,900 28-95,600 28-95,600 HEAT OUTPUT MIN kw - Btu/h 9.5-32,400 9.5-32,400 12.5-42,600 12.5-42,600 SEDBUK RATING Band D D D D CENTRAL HEATING TEMPERATURE MIN/MAX C 35/85 35/85 35/85 35/85 BUILT-IN EXPANSION VESSEL CAPACITY l 6 6 6 6 BUILT-IN EXPANSION VESSEL PRE-CHARGED PRESSURE bar 0.7 0.7 0.7 0.7 MAXIMUM HEATING PRESSURE bar 3 3 3 3 ELECTRICAL SUPPLY V/Hz 230/50 230/50 230/50 230/50 POWER CONSUMPTION W 150 150 150 150 PROTECTION GRADE OF ELECTRICAL SYSTEM IP X4D X4D X4D X4D INTERNAL FUSE RATING F1/F2 A 2/1.25 2/1.25 2/1.25 2/1.25 EXTERNAL CONTROLS V 24 24 24 24 LIFT WEIGHT kg 33.5 35.2 35.5 37.2 G.C. NUMBER 41-980-15 41-980-16 41-980-17 41-980-25

CMYK SUPPORT & AFTERSALES SERVICE Service Centres With a network of regional service centres, the Chaffoteaux support team are always local to our customers needs. The after sales service operation has access to over 140 trained engineers nationwide. Service Centres Warranty Helpline 0870 243 0224 Installer Technical Support Hotline 01952 222288 Guarantee All Chaffoteaux & Maury unvented cylinders are covered by a five year guarantee on the cylinder tank and a two year guarantee on electrical components. Both cover parts and labour and operate from the date of installation. Service In guarantee service is carried out by our nationwide network of Service Agents who can normally respond within 24 hours from the receipt of a call. A list of Approved Service Agents is available on request. Spares A comprehensive selection of spare parts is carried out by Approved Spare Parts Stockists, located throughout the UK. Chaffoteaux & Maury reserve the right to modify these specifications without notice in the interest of continued product development. More detailed technical information on the full range of Chaffoteaux appliances can be obtained from the address shown below or by contacting our Customer Services Department on 01952 222727. Training The Chaffoteaux & Maury Training Centres allow you to learn and expand your knowledge of the field. Courses cover areas such as customer relations, product selection, installation, system start-up, checks, maintenance, guarantees, and legislative standards. In the interests of our customers, MTS (GB) Limited is continually developing these products to improve both performance and design. We therefore reserve the right to change specification without prior notice. This brochure is accurate at the date of printing. Consumer statutory rights are not affected Assurance of Quality AFAQ N o 1996/5186 MTS (GB) Limited MTS Building Hughenden Avenue High Wycombe Bucks, HP13 5FT Tel: 01494 755600 Fax: 01494 459775 Technical Support Help Line 01952 222288 www.chaffoteaux.co.uk E-mail: info@mtsgb.ltd.uk