Unvented water heating

Similar documents
Hotflo. Unvented point of use hot water

Cistern-fed water heating

Combined electric boiler and domestic hot water store

Multipoint. Unvented point of use hot water

Amptec. Electric flow boiler

Unvented water heating

Streamline. Vented point of use hot water

Unvented Water Heaters. September Aqualine. Unvented Electric Water Heating

2015 PRODUCT RANGE GUIDE

Multipoint Technical Data

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Electromax. Combined electric boiler and domestic hot water store

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Ventilation Product range ADVANCE ECO 4 ECO 2

UNVENTED POINT-OF-USE HOT WATER PRODUCT RANGE

Handy Dri / Hair Drier

MEGAFLO HE Iss 1

HEATRAE SADIA. Installation and User Instructions for the UTC Undersink Vented Water Heater

Megaflo eco Unvented hot water cylinders

Water. Heating. Connect with the Best. Electric Showers Power Showers 324. Shower Pumps 324. Beverage Water Dispensers

HOTFLO 10 / 15. Fitting Instructions and User Guide

MULTIPOINT SS H 50/80 & 100

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Hand Hygiene. September 2015 EV Instantaneous Handwash

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

HOTFLO 10 / 15. Fitting Instructions and User Guide

Unvented Water Heating. Zircon

Megaflo eco. Unvented hot water cylinders

Installation and User Instructions Aquaheat Unvented Water Heaters Models: SS V 50/80 & 100

Regulations, Legislation and Byelaws

Cylinders & Water Heaters

Installation and User Instructions HS10U, HS15U.

Unvented Electric Water Heater 10/15 litre Undersink

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

MULTIPOINT 30 & 50 Litre

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Installation and User Instructions Aquaheat Unvented Water Heaters Models: AH30H

Exceeding the Standard

Exceeding the Standard

VENTED POINT-OF-USE HOT WATER PRODUCT RANGE

STREAMLINE OVERSINK. Fitting Instructions and User Guide _iss_05.indd 1 15/09/ :46:30

Streamline Undersink. Fitting Instructions and User Guide

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Express 50 Litres Installation, operation and maintenance manual

CROWN WATER HEATERS CPU10 - CPU15 CPOS10 - CPOS15

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Megaflo Eco Unvented Direct & Indirect Hot Water Cylinders

SUPREME 140, 155, 170

Cylinders - Vented Water Heaters - Electric Water Heaters - Domestic 314

Megaflo Eco Plus Unvented Indirect Hot Water Cylinders 800L L

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Fitting Instructions and User Guide

Multipoint. Installation and User Instructions Instantaneous Hand Wash Models: EV 2008

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

Stored Water District Heating Interface Units. Heat Interface Units

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Megalife Vented Cistern Fed Water Heater Installation manual

SPEEDIBOIL Installation and User Instructions. Models: SP2.5, SP5.0, SP7.5

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Total Hot Water Solutions

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Unvented Copper Hot Water Cylinders

Water Heating Systems

Solar thermal domestic hot water system

Megalife Solar Vented Cistern Fed Water Heater Installation manual

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

Unvented Direct & Indirect Hot Water Cylinders

ADVANCED WATER COMPANY LTD COPPERFORM. Advanced Water Company Ltd. Unvented Hot Water Cylinders. Supplied By Advanced Water Company Ltd

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Unvented Direct & Indirect Hot Water Cylinders (400L L)

SOLAR HEATING SYSTEMS

Installation and Servicing Instructions. Alpha GasSaver GS-1

Megaflo Eco Unvented Direct & Indirect Solar Hot Water Cylinders

Fitting Instructions and User Guide

THERMOSTATIC SHOWER VALVE

INSTALLATION MANUAL. RD SERIES Digital Electric Water Heater Wall-hung Unvented

Megaflo Eco Slimline Unvented Direct & Indirect Hot Water Cylinders 100L - 200L

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Megaflo Eco Solar PV Ready Unvented Direct & Indirect Hot Water Cylinders 170L - 300L

IMPORTANT: PLEASE READ ALL THESE INSTRUCTIONS BEFORE COMMENCING INSTALLATION

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Cylinder Manual. Open Vented Cylinders Stainless Steel Water Heaters. Twin Coil TW180V TW210V TW250V TW300V Triple Coil TR250V TR300V

Supreme 150SS, 165SS, 180SS Fitting Instructions and User Guide

Instructions for Use Installation and Servicing

SMART HOT WATER SOLUTIONS PRODUCT RANGE

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Handy No Touch Electric Handwash Fitting Instructions

maximise the sun s energy with warmflow solar Warmflow Solar

Unvented Direct & Indirect Hot Water Cylinders (400L L)

ELECTRIC HEATING SOLUTIONS PRODUCT RANGE

MEGAFLO Eco Plus Solar Unvented Hot Water Cylinders 400L -570L

MW & EW 10 & 15 Litre Unvented Water Heaters HANDBOOK. IMPORTANT: This booklet should be given to the customer after installation and demonstration.

Baxi Maxflow Combi WM

Transcription:

Unvented water heating Multipoint 75 / 100 95 900 871 Issue 1

Introduction 03 Unvented water heating The demand for unvented systems continues to increase as their benefits are recognised by specifiers, installers and end users. The new Multipoint 75 and 100 litre units offer unvented water heater performance and are quicker and easier to install. Based on the highly successful Multipoint range, the new 75 and 100 litre models are designed to significantly reduce installation time. These wall mounted units are supplied factory-assembled with all necessary valves and controls pre-installed ready for connection to the mains services resulting in a much easier, faster and neater installation. Mains pressure and high flow rates at all hot taps Balanced hot/cold water supplies Ideal for multi-basin installations Flexible siting - no need for cold water cistern Can be used with standard taps Specification Advice Tel 01603 420220 Fax 01603 420229 E-mail specifier@heatraesadia.com

04 Features and benefits Multipoint 75/100 Multipoint 75/100 are ideal for commercial applications such as cloakrooms, kitchens or washrooms, where a single heater is required to service multiple draw-offs. Both products may also be used for single point showering and are available with 6kW rating (2 x 3kW elements) for use in locations where faster hot water recovery is required.* As with all unvented units above 15 litres, it is a Building Regulation requirement that installers are competent to install Multipoint 75 and 100 litre units. This normally means having successfully completed a course in unvented systems. For details on training courses call 0845 600 7402. Multipoint 75/100 selection matrix Capacity Basins 75 5 to 8 100 8 to 10 N.B. Figures are for guidance only, the Heatrae Sadia Specifier Advice team should be contacted to discuss requirements for specific sites. 75 and 100 litre capacities Choice of 3.0kW or 6.0kW rating Factory-fitted temperature and pressure relief valves Twin heavy gauge copper inner containers Replaceable long life alloy sheathed elements Adjustable thermostats 5 C to 75 C max. Suitable replacement for Cistern-type water heaters where improved water flow required CFC/HCFC free (ODP zero) insulation GWP 3.1 (Global Warming Potential) Element On indicator No anodes to inspect or replace Suitable for use with any standard mixers or taps Fitted with 1 metre of 3-core cable Comprehensive installation instructions BEAB and kiwa approved Five year on-site parts and labour inner container guarantee Items supplied factory fitted to all units Expansion vessel Pressure relief (expansion) valve Temperature & pressure relief valves Items supplied loose Combined pressure-reducing valve with built-in strainer Tundish Mounting brackets * Depending on demand, increased effective capacity and levels of user protection can be achieved by the use of Heatrae Sadia's thermostatic blending valve Pack U3 or U7 (See page 6).

12 12 6 6 7 1 2 4 3 5 11 10 8 9 1 Expansion vessel 2 Pressure relief valve 3 Non return valve 4 Thermostats 5 Safety cut-outs 6 Element plate assemblies 7 Element 'On' neon 8 Inlet 9 Discharge 10 Outlet 11 Cable entry 12 Temperature and pressure relief valves

06 Accessory selection Multipoint 75/100 ACCESSORIES Thermostatic blending valves Pack U3 and U7 for use with all Multipoints; Thermostatic blending valves allow water to be stored at high temperatures and blended with cold water to a preset outlet temperature. This provides over-temperature protection, and is ideal for the control of Legionellae and the extension of system capacities. Water expands by up to 4% when heated (See Fig. 1). This means that the design of the water heater and the installation in which it is used are critical. Conventional (vented) and unvented systems allow for expansion in different ways. FIG. 1 TMV Installation PACK U3 TMV2 Connection 15mm compression. Allows water to be safely stored above 60 C Precisely controls outlet water temperature (range 35 C to 60 C) Lockable control knob Fail-safe shutdown Incorporates check valves to prevent cross contamination Operating pressure 0.2 bar to 6.0 bar PACK U7 TMV3 Connection 15mm compression. Fully approved under the TMV3 scheme to the DO8 specification Allows water to be safely stored above 60 C Precisely controls outlet water temperature (range 38 C to 46 C) Unique adjuster key to prevent unauthorised temperature adjustment Fail-safe shutdown Incorporates check valves to prevent cross contamination Operating pressure 0.2 bar to 5.0 bar Heater EXPANSION % 4 3 2 1.2 1 0 4.34 10 20 30 40 50 60 70 80 90 100 TEMPERATURE RISE With unvented systems, there are no cistern tanks or open outlets to accommodate expansion. All systems above 15 litre, and some systems of 15 litre or less, employ an expansion vessel or an internal air-gap to accommodate expansion. With larger systems (above 15 litre), expansion is accommodated either by a separate expansion vessel or an internal air-gap. Multipoint 75 and 100 litre units use an expansion vessel which is supplied factory fitted within the casing. They are supplied complete with all the necessary components and controls to provide a safe and efficient method of providing stored mains pressure hot water. O C Outlet taps Blended water to outlets Balanced cold water supply Hot outlet Pack U3 or U7 blending valve Cold water in Building Regulations Direct connection to the cold mains supply has been permitted in the UK since 1987. All units above 15 litre must be installed to meet the requirements of the Building Regulations. It is a legal requirement that the local Building Control Officer be notified of any proposed installation of unvented water heating systems over 15 litre capacity. Products up to 500 litre and 45kW must be approved by a recognised body such as the British Board of Agrément (BBA) and BEAB and be fitted by an installer who has successfully completed a recognised course in the installation of unvented heating systems such as CITB. Technical Support Heatrae Sadia offers a dedicated Specifier Advice line to provide information and advice on specification and installation. This is supported by a fully-trained national sales team, all of whom are qualified to provide further guidance and support locally. Requirements call for an expansion space (internal or external), safety devices to prevent the stored water exceeding 99 C, and pipework to convey discharged hot water safely away from the safety devices.

Diagram Dimensions Specification Installation Guarantee Ordering guide 07 Multipoint Specification Capacities 75 and 100 litre. Rating 3.0kW @ 240V (2 x 1.5 kw), (2.8kW @ 230V (2 x 1.4 kw)). 6.0kW @ 240V (2 x 3.0 kw), (5.6kW @ 230V (2 x 2.8 kw)) Outer casing White plastic top and base mouldings with steel centre section finished in white stove enamel. Thermal insulation CFC/HCFC free (ODP zero) GWP 3.1 (Global Warming Potential) flame-retardant expanded polyurethane. Water container 2 x Heavy gauge copper inner containers. Type tested to 20 bar (290 psi) Heat unit Replaceable Superloy 825 alloy sheathed rod-type elements. Thermostat Capillary thermostats, adjustable from 5 C to 75 C. Safety features Manually re-settable thermal cut-outs. Factory-fitted temperature and pressure relief valves set to operate at 7 bar and 90 C. Anode Not required. Approvals BEAB and kiwa approved to UK water supply regulations. Manufactured in the UK in a BS EN ISO 9001:2000 registered factory. A B C D Electrical The unit must be permanently connected to the electrical supply through a double-pole linked switch with minimum breaking capacity suitable for the loading. Must conform to current IEE wiring regulations. Installation 565 729 Dimensions and capacities Model Capacity A B C D litre mm mm mm mm Multipoint 75 75 1055 911 824 843 Multipoint 100 100 1213 1069 982 1001 430 79 Must be installed by a competent person in accordance with local Regulations. England and Wales - Building Regulations G3, Scotland - Technical Standards P3, N. Ireland - Building Regulations P5. Fixing Mounting brackets supplied loose. Must be mounted in the vertical position with inlet/outlet at the bottom. Temperature and pressure relief valves factory fitted to the top of the heater. Plumbing Connections 15mm copper tube tails. Minimum water pressure 0.8 bar (12 psi). Discharge from tundish 22mm compression Tundish Multipoint 75 & 100 units are supplied with a tundish. Inlet 1 2" BSP male. Outlet 3 4" BSP female. Service valve 15mm compression. Safety valve discharge Temperature and pressure relief valve and expansion valve must be plumbed to discharge in a safe visible manner. (Tundish supplied). Guarantee Multipoint is covered by the Heatrae Sadia on-site parts and labour guarantee. Multipoint inner container is guaranteed for a period of five years and its immersion heater and thermal control for a period of two years from the date of purchase against faulty manufacture and materials provided that: Has been correctly installed as per the instructions contained in the instruction manual and all relevant codes of practice and regulations in force at the time of installation. Has not been modified in any way, other than by Heatrae Sadia Heating. Has been regularly maintained in accordance with the instructions contained in the instruction manual. Has not been damaged by frost or due to scale. Has only be used with potable water. Has not been tampered with or been subjected to misuse or neglect. Registration card has been completed by the user and returned to Heatrae Sadia within 60 days of installation together with the proof of purchase. Has been installed in the United Kingdom. The guarantee is transferable. The guarantee does not affect your statutory rights. The unit is not guaranteed against damage by frost. The Multipoint immersion heater and thermal controls are guaranteed for a period of two years, from the date of purchase, with the exception of damage due to excessive scaling. Evidence of purchase and date of supply must be submitted. The guarantee will not be transferable. This guarantee does not affect your statutory rights. Ordering guide Model Rating Product code @ 240V kw Multipoint 75 3 95:050:170 Multipoint 75 6 95:050:171 Multipoint 100 3 95:050:172 Multipoint 100 6 95:050:173 Pack U3 (TMV2) 95:970:354 Pack U7 (TMV3) 95:970:360 Specification Advice Tel 01603 420220 Fax 01603 420229 E-mail specifier@heatraesadia.com

Products Boiling water Supreme Supreme SS Chilled water SuperChill Cistern-fed water heating MegaLife HE Cistern-type water heating FBM Electric flow boiler Amptec Electromax Electric showers Accolade Carousel Sapphire Cameo Hand hygiene Handy Concept Hair Drier Handy Dri Immersion heaters Titanium Superloy Gold Dot Maxistore RDT Thermostats Point of use Streamline Express UTC 99 B3M C3M Vented tap range Small unvented water heating Hotflo Multipoint Unvented water heating Megaflo HE Megaflo HE SystemFit Multipoint 75/100 For free product brochure(s) call our literature hotline on 01603 420127 Contact Specification T: 01603 420220 F: 01603 420229 E: specifier@heatraesadia.com Sales T: 01603 420110 F: 01603 420149 E: sales@heatraesadia.com Service T: 01603 420330 F: 01603 420349 E: service@heatraesadia.com Web www.heatraesadia.com National service network Heatrae Sadia products are inherently reliable and are designed to meet the demanding needs of all users. A nationwide network of experienced engineers is available to provide fast and efficient on-site service support. In addition, spare parts for the complete range of products are readily available through a wide variety of stockists. Heatrae Sadia Heating Hurricane Way Norwich Norfolk NR6 6EA Heatrae Sadia Heating may introduce modifications to their products from time to time. Consequently, the details given in this brochure are subject to alteration without notice. 95 900 871 Issue 1 Heatrae Sadia Heating. March 2006.