Homeflow Product Brochure Issue 1 - Jan Creating Excellence, Building Reputation Unvented Water Storage From The Experts...

Similar documents
Unvented Cylinder Brochure Issue 1 - Jan Creating Excellence, Building Reputation Unvented Water Storage From The Experts...

INTERCYL. INTERNAL EXPANSION EXCELLENCE

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: MonoWave single-coil and DuoWave twin-coil unvented heat pump cylinders

Unvented Hot Water Systems for the Professionals

WAVE CYLINDER RANGE. High efficiency direct and indirect hot water storage solutions

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

UNVENTED STAINLESS STEEL CYLINDERS

Stainless Steel Unvented Cylinders

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

Grant Wave range. High efficiency direct and indirect hot water storage solutions

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

Discover the ALL new Range Tribune Xe Engineered for maximum EFFICIENCY

CI/SfB. (53.3) x. October Unvented Water Heaters. PremierPlus. Unvented Hot Water Cylinders

SOLAR HEATING SYSTEMS

Tornado & Tempest Stainless Installation Guide & Customers Copy (including Solar, Heat Pump & Horizontal)

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

SMART HOT WATER SOLUTIONS PRODUCT RANGE

Multipoint. Unvented point of use hot water

Exceeding the Standard

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

the electric heating company ELECTRIC BOILER HANDBOOK

Unvented Hot Water Systems for the Professionals

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Harlequin HeatStream Case Study

SMART HOT WATER SOLUTIONS PRODUCT RANGE

ADVANCE ECB ELECTRIC COMBINATION BOILER

Exceeding the Standard

Instructions & Maintenance

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

H o t Wa te r Syste m s. Unvented Copper Hot Water Cylinders for Heat Pump and Solar Input. Exceeding the Standard

SEALED THERMAL STORE

Knight & Charger Water Heaters

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

Specifica Copper tion Renewable ene Stainless rgy HOT WATER SOLUTIONS

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

extreme HIGH EFFICIENCY HOT WATER SYSTEMS

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

unistor High performance unvented stainless steel cylinder range

WALL-HUNG SYSTEM & UNVENTED CYLINDERS

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

Heating And Hot Water Solutions

Broag Pressurisation equipment

unistor High performance unvented stainless steel cylinder range

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

Combi Konverter Solar System

THERMAL STORE MAINS PRESSURE SYSTEM

For latest prices and delivery to your door visit MyTub Ltd

THERMAL STORE MAINS PRESSURE SYSTEM

Commercial Hot Water Solutions Ltd.

The Ultimate Solution for Electric Central Heating. Fusion. Comet

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

A HOT WATER REVOLUTION

Installation Manual EXCELSIOR Unvented Water Heater

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

THERMflow Thermal Store Cylinders

Unvented water heaters

H o t Wa te r Syste m s. Copper Hot Water Products. Exceeding the Standard

WATER HEATERS INSTALLATION MANUAL

Water Heating UK 14 th May 2016

EcoSeries S O L A R H O T WAT E R S O L U T I O N S. Ecological & Economical

PremierPlus. and PremierPlus SystemFit. Direct and Indirect Unvented Water Heating. Unvented Water Heaters

1845 Tech Manual.qxd 23/11/05 1:20 pm Page 2 EXCELSIOR UNVENTED WATER HEATERS INSTALLATION MANUAL. Design for living

ADVANCE STAINLESS STEEL UNVENTED HOT WATER SYSTEMS

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

A Hot water revolution

Instructions for Use Installation and Servicing

POINT OF USE WATER HEATERS

Tornado & Tempest Stainless. Installation Guide & Customers Copy (including Solar, Heat Pump & Horizontal)

VENTED CYLINDER RANGE

maximise the sun s energy with warmflow solar Warmflow Solar

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

Tristor MF. Installation Guide

Total Hot Water Solutions

ADVANCE ELECTRIC THERMAL STORE

IMAGINATION SOLAR LTD. Installation Guide B1. Planning the Plumbing and Wiring

UNIQ HEAT BATTERIES REFERENCE MANUAL_V2.2. Version: 2018_07_19_v2.2

Where gas is not an option,

Saving energy comes naturally to us.

Kills bills. How Vaillant technologies reduce home heating bills

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Schuco SS-TC/SC Cylinders

CUBEflow Thermal Store Tank

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Quantum. Installation, User and Service Manual. Hot Spring

Performance on demand. Eliminate poor mains water pressure and flow problems. with mainsboost

Transcription:

reating xcellence, uilding Reputation Unvented Water Storage rom The xperts... Product rochure Issue 1 - Jan 2013 or more information go to www.rmcylinders.com - www.rmsolar.com

Introducing RM... MT OUR RN of unvented products s we plan and prepare this, the new edition of our corporate sales catalogue I realise five years have now passed since we produced our first cylinder under the RM ylinders banner. The last five years have passed so quickly in an absolute whirlwind of activity, it seeming only yesterday we proudly shipped our first cylinder to the customer. Our initial product offering of open vented copper cylinders has quickly been complimented by the readily accepted addition of the quastel stainless steel open vented cylinder bringing traditional storage systems right up to date with 21st century materials. In the unvented storage sector our popular Stelflow range of cylinders has grown to include storage up to 600 litres providing an enhanced compatibility in water storage not only with gas, oil and electricity but also with the growing market of solar renewables. Specified demand of the, an unvented storage cylinder specifically designed to meet the exacting needs of the new build sector has gratifyingly exceeded our forecasts. Our new unvented cylinder, the Prostel, launched with this edition of the product catalogue will fill a much needed gap in market indicated by our customer research. nother important growth area within our business portfolio is the continued expansion of our valued OM customer base and it is of immense pride for us when such a customer trusts RM to produce products to their exacting design and specification. In conjunction with an ever growing product and customer portfolio the company has made significant investment into both staff and equipment ensuring that in all areas of our business we provide professional, efficient and effective products and service. This our 5th anniversary year will celebrate the opening of a 5000 sq. ft. extension to our stainless steel production facility which will provide both increased levels of production and further improvements in our service. Richard Marsden Managing irector 1

Our Quality In Vision... nsuring quality throughout our products The RM has carefully been constructed using quality components and has been designed with performance in mind. Using our many years of involvement within the hot water industry and our knowledge of bringing unvented cylinders to the market we have created a new standard in unvented water storage. offers the following advantages: Specially made units manufactured to your own design. ull range of slim units available, 60L to 210L, featuring a diameter of only 475mm one of the slimmest on the market. range of horizontal cased units. oil in coil heat exchanger, giving high recovery rates. xternal expansion for reliability and flexible siting. ull KIW product approval. Vessel constructed from uplex Stainless Steel. Superior insulation values, with an OP of 0 and WP of 1. omprehensive controls and fixing kit from leading manufacturers. offers peace of mind: 25 Year vessel guarantee. Stainless Steel stat pocket guaranteed against corrosion. ll other cylinder components guaranteed for 2 years. ll units are pickled to ensure longer life. offers many technical benefits: Minimum recommended working pressure 1 bar & maximum 3 bar. ll cylinder connections are 22mm compression. Minimum water supply 1.5 ar, 20 Litres/Min. Primary coil circuit must be fully pumped, gravity coils are available by special order. ll units available as vented cylinders. ontrol settings: 1. Pressure reducing valve set at 3 ar. 2. xpansion relief valve set at 6 bar. 3. Temperature and pressure relief valve at 7 bar and 90 o. 4. High Limit stat set at 85 o. 2

Performance... our products are more than just good looks 90 120 150 180 210 250 300 Weight mpty (K) Weight ull (K) ull old apacity (L) Reheat Indirect Total Minutes Reheat 3kW Immersion Minutes Heat xchange kw edicated Solar Volume Litres Standing Loss ylinder kwh/day irect 17 107 90-76 - - 1.07 Indirect 21 109 88 12 53 16.46-1.07 irect 21 141 120-103 - - 1.23 Indirect 25 143 118 16 80 16.46-1.23 irect 26 176 150-134 - - 1.41 Indirect 29 177 148 17.2 106 18.55-1.41 irect Solar 29 177 148 17.2 107 16.46 80 1.41 Solar Twin 34 181 147 17.2 57 16.46 77 1.41 irect 28 208 180-164 - - 1.53 Indirect 33 211 178 20.4 136 18.55-1.53 irect Solar 33 211 178 20.4 129 18.55 100 1.53 Solar Twin 36 213 177 20.4 80 18.55 95 1.53 irect 32 242 210-203 - - 1.8 Indirect 37 245 208 22 167 18.55-1.8 irect Solar 37 245 208 22 150 18.55 116 1.8 Solar Twin 40 247 207 22 93 18.55 101 1.8 irect 39 289 250-248 - - 2.15 Indirect 43 291 248 25 213 22-2.15 irect Solar 43 291 248 25 183 22 137 2.15 Solar Twin 46 293 247 25 113 22 107 2.15 irect 45 345 300-323 - - 2.28 Indirect 50 347 297 34 285 22-2.28 irect Solar 50 347 298 34 220 22 160 2.28 Solar Twin 55 353 298 34 139 22 121 2.28 3

Technical Specification... H ode 90 120 150 180 210 250 300 apacity 90L 120L 150L 180L 210L 250L 300L Height 727() 915() 1102() 1290() 1478() 1728() 2041() iameter 545 545 545 545 545 545 545 old Inlet 105() 105() 105() 105() 105() 105() 105() ottom oil - - - - - - - Immersion 242() 242() 242() 242() 242() 242() 242() Stat Pocket - - - - - - - Immersion - 519() 619() 719() 819() 959() 1109() Sec. Return - - - - 1009() 1259() 1509() T&P Valve 515() 703() 890() 1078() 1266() 1516() 1829() ode 90I 120I 150I 180I 210I 250I 300I apacity 90L 120L 150L 180L 210L 250L 300L Height 727(H) 915(H) 1102(H) 1290(H) 1478(H) 1728(H) 2041(H) iameter 545 545 545 545 545 545 545 old Inlet 105() 105() 105() 105() 105() 105() 105() ottom oil 299() 299() 339() 374() 374() 374() 374() Immersion 339() 339() 379() 379() 414() 414() 414() Stat Pocket 354 () 354() 394() 394() 474() 569() 669() Immersion - - - - - 959() 1109() Sec. Return - - - - 1159() 1409() 1609() T&P Valve 515() 703() 890() 1078() 1266() 1516() 1829() Twin coil cylinder Solar direct cylinder irect cylinder Indirect cylinder I H H ode 90T 120T 150T 180T 210T 250T 300T apacity - - 150L 180L 210L 250L 300L Height - - 1102(I) 1290(I) 1478(I) 1728(I) 2041(I) iameter - - 545 545 545 545 545 old Inlet - - 105() 105() 105() 105() 105() ottom oil - - 299() 299() 374() 374() 374() Stat Pocket - - 354() 354() 429() 429() 429() Immersion - - - - - - - Top oil - - 651() 675() 789() 863() 989() Immersion - - 702() 734() 839() 914() 1039() Stat Pocket - - 706() 738() 843() 918() 1043() Sec. Return - - - - 1159() 1409() 1609() T&P Valve/Stat - - 890(H) 1078(H) 1266(H) 1516(H) 1829(H) ode 90S 120S 150S 180S 210S 250S 300S apacity - - 150L 180L 210L 250L 300L Height - - 1102(H) 1290(H) 1478(H) 1728(H) 2041(H) iameter - - 545 545 545 545 545 old Inlet - - 105() 105() 105() 105() 105() ottom oil - - 299() 299() 374() 374() 374() Stat Pocket - - 354() 354() 429() 429() 429() Immersion - - 399() 454() 509() 584() 679() Top oil - - - - - - - Immersion - - 619() 719() 819() 959() 1109() Stat Pocket - - - - - - - Sec. Return - - - - 1159() 1409() 1609() T&P Valve/Stat - - 890() 1078() 1266() 1516() 1829() 4

Slimline Performance... Same great product but with a smaller footprint Only 475mm iameter Slimline 60 Slimline 90 Slimline 120 Slimline 150 Slimline 180 Slimline 210 Weight mpty (K) Weight ull (K) ull old apacity (L) Reheat Indirect Total Minutes Reheat 3kW Immersion Minutes Heat xchange kw edicated Solar Volume Litres Standing Loss ylinder kwh/day irect 21 81 60-46 - - 0.99 Indirect 23 81 58 9 30 16.2-0.99 irect 25 115 90-77 - - 1.2 Indirect 27 115 88 13 54 16.2-1.2 irect 31 151 120-104 - - 1.4 Indirect 36 154 118 17 81 16.2-1.4 irect 39 189 150-135 - - 1.6 Indirect 45 193 148 18 107 18.35-1.6 irect Solar 47 193 148 18 108 16.2 80 1.6 Solar Twin 49 194 147 18 59 16.2 77 1.6 irect 45 225 180-165 - - 1.9 Indirect 50 228 178 22 137 18.35-1.9 irect Solar 53 228 178 22 130 18.35 100 1.9 Solar Twin 55 230 177 22 81 18.35 95 1.9 irect 48 258 210-205 - - 2.16 Indirect 53 261 208 24 168 21-2.16 irect Solar 55 261 208 24 151 21 116 2.16 Solar Twin 58 264 207 24 95 21 101 2.16 5

Slimline Technical Specification... irect cylinder Indirect cylinder ode 60S 90 120S 150S 180S 210S apacity 60L 90L 120L 150L 180L 210L Height 645() 930() 1195() 1470() 1735() 1980() iameter 475 475 475 475 475 475 old Inlet 105() 105() 105() 105() 105() 105() ottom oil - - - - - - Immersion 223() 223() 223() 223() 223() 223() Immersion - - 733() 916() 1093() 1256() Sec. Return - - - - - 1676() T&P Valve 448() 733() 998() 1273() 1538() 1783() ode 60SI 90SI 120SI 150SI 180SI 210SI apacity 60L 90L 120L 150L 180L 210L Height 645() 930() 1195() 1470() 1735() 1980() iameter 475 475 475 475 475 475 old Inlet 105() 105() 105() 105() 105() 105() ottom oil 299() 299() 299() 339() 339() 374() Immersion 339() 339() 379() 379() 414() 414() Stat Pocket 354() 354() 354() 394() 394() 474() Sec. Return - - - - - 1676() T&P Valve 448() 733() 998() 1273() 1538() 1783() Twin coil cylinder Solar direct cylinder I H H ode 60ST 90ST 120ST 150ST 180ST 210ST apacity - - - 150L 180L 210L Height - - - 1470(I) 1735(I) 1980(I) iameter - - - 475 475 475 old Inlet - - - 105() 105() 105() ottom oil - - - 280() 280() 355() Stat Pocket - - - 335() 335() 410() Immersion - - - - - - Top oil - - - 632() 676() 770() Immersion - - - 683() 715() 820() Stat Pocket - - - 687() 719() 824() Sec. Return - - - - - 1563() T&P Valve/Stat - - - 1273(H) 1538(H) 1783(H) ode 60SS 90SS 120SS 150SS 180SS 210SS apacity - - - 150L 180L 210L Height - - - 1470(H) 1735(H) 1980(H) iameter - - - 475 475 475 old Inlet - - - 105() 105() 105() ottom oil - - - 280() 280() 355() Stat Pocket - - - 320() 320() 395() Immersion - - - 335() 335() 445() Top oil - - - - - - Immersion - - - 916() 1093() 1256() Stat Pocket - - - - - - Sec. Return - - - - - 1676() T&P Valve/Stat - - - 1273(H) 1538(H) 1783(H) 6

Kit omponents Quality down to the last component irect cylinder Product 90L 120L 150L 180L 210L 250L 300L old Water Inlet Set 1 1 1 1 1 1 1 15x22mm Tundish 1 1 1 1 1 1 1 Temperature & Pressure Relief 1 1 1 1 1 1 1 xpansion Vessel 12L 12L 12L 12L 18L 18L 24L xpansion Vessel racket 1 1 1 1 1 1 1 Immersion Heater 1 2 2 2 2 2 2 2 Port Zone Valve 0 0 0 0 0 0 0 ual Thermostat 0 0 0 0 0 0 0 nergy ut Out Thermostat 0 0 0 0 0 0 0 Plastic rommet 0 0 0 0 0 0 0 Instruction Manual 1 1 1 1 1 1 1 Indirect cylinder Product 90L 120L 150L 180L 210L 250L 300L old Water Inlet Set 1 1 1 1 1 1 1 15x22mm Tundish 1 1 1 1 1 1 1 Temperature & Pressure Relief 1 1 1 1 1 1 1 xpansion Vessel 12L 12L 12L 12L 18L 18L 24L xpansion Vessel racket 1 1 1 1 1 1 1 Immersion Heater 1 1 1 1 1 2 2 2 Port Zone Valve 1 1 1 1 1 1 1 ual Thermostat 1 1 1 1 1 1 1 nergy ut Out Thermostat 0 0 0 0 0 0 0 Plastic rommet 0 0 0 0 0 0 0 Instruction Manual 1 1 1 1 1 1 1 Twin coil cylinder Product 150L 180L 210L 250L 300L old Water Inlet Set 1 1 1 1 1 15x22mm Tundish 1 1 1 1 1 Temperature & Pressure Relief 1 1 1 1 1 xpansion Vessel 12L 12L 18L 18L 24L xpansion Vessel racket 1 1 1 1 1 Immersion Heater 1 1 1 1 1 2 Port Zone Valve 1 1 1 1 1 ual Thermostat 1 1 1 1 1 nergy ut Out Thermostat 1 1 1 1 1 Plastic rommet 1 1 1 1 1 Instruction Manual 1 1 1 1 1 7

RM Pre-Plumb Unit... Making installation a whole lot easier Single zone unit Twin zone unit The RM unit is available in an upgraded plug and go pre-plumbed format. This is available right across our range of units including Slimline, Twin oil, and Horizontal cylinders. This makes installation quicker and easier saving the contractor both time and money. We can also guarantee our workmanship as we have in place stringent quality checks to make sure the units arrive leak free and ready to go. ll units are assembled in our premises and over seen be qualified plumbers. ll these benefits are available whilst remaining within our competitive pricing policy. Special pre-plumb units custom fitted to customer requirements giving ultimate flexibility. ual Zone control available for larger properties. vailable in 150, 180, 210, 250, and 300 litre Indirect and Twin oil variations. Slimline and Horizontal cylinders. Supplied with automatic bypass valve fitted. Unit comes with seven day programmer, room thermostat and central heating expansion vessel pack. asyfit plug in electrical leads and connections negates the need for an electrician on site hence removes the problem of Part P Registration. 8

Pre-Plumb omponents... supplying the whole package ready to go Plug & Play 2 port valve utomatic airvent utomatic bypass valve Plug & play dual stat illing loop Plug & play pump Plug & play wiring center 7 day programmer Room thermostat Heating expansion vessel RM ylinders reserve the right to change the design and style of the components supplied at any time. When ordering spare parts to ensure consistency and compatibility please contact our technical department who will be pleased to help you with your enquiry. In addition to these components RM ylinders also provide the following from the standard unvented kit: old Water Inlet Set Tundish T&P Relief Valve Potable Water xpansion Vessel xpansion Vessel racket 3kW Immersion Heater(s) 9

RM Mainsboost & harger Unit... Improving flow rates & pressure on any system Unvented cylinders rely on reasonable mains pressure and flow rates to provide adequate performance at the taps. In some instances water demand is so high the water supply networks struggle to provide the water flow and pressure necessary, which has a significant impact on the performance of showers and taps. This problem can be overcome in two ways. irstly using the RM Mainsboost accumulator to improve poor flow rates, and the RM harger unit to boost pressure. The fully patented RM Mainsboost increases flow by being charged by the incoming mains supply and then awaits discharge when water is required at the tap. The RM harger unit, again patented, solves the problem of low water pressure without the need for large, expensive break tanks. This in simple terms, when used with the RM Mainsboost, is a pump that acts as a trickle charger to the accumulator which then acts as the battery storing the pressure for when the water is required. Size Height (mm) iameter (mm) onnection Size Weight mpty 100L Mainsboost 890 410 28mm ompression 19K 200L Mainsboost 1030 535 28mm ompression 34K 240L Mainsboost 1210 535 28mm ompression 37K 310L Mainsboost 1500 535 28mm ompression 46K 450L Mainsboost 1530 660 28mm ompression 70K Size Height (mm) iameter (mm) onnection Size Weight mpty RM harger Unit 485 287 152 19K Upstream Kit Includes: Pressure auge, Strainer, ouble heck Valve, Pressure Reducing Valve /W auge, ull ore Isolating Valve, & Vessel onnection. Vessel capacity is 50% of total volume. ll models supplied with upstream line in kit. RM Mainsboost carry a 5 year warranty. 10

Introducing RM nviroyl... ir source & round source Heatpump ylinder RM ylinders also offer a now well established nviroyl cylinder range. These systems encompass all the benefits of stored unvented hot water in a Stainless Steel vessel while using plate to plate heat transfer to give exceptional performance. The system is built around a specially designed ylinder which still comes with a 25 year guarantee. Most indirect cylinders are designed for use with space heating boilers and their heat exchanger coils are optimised for primary flow temperatures in the region of 80 o. When using heat pumps the maximum available primary flow temperatures are often well below this level. The majority of ir Source and round Source heat pumps will only give a maximum flow temperature of around 50 o, some will go up to 60 o but this is usually accompanied by a fall in the coefficient of performance (OP) to a level where the overall efficiency may be significantly compromised. or traditional boiler applications the most popular form of heat exchanger is the coil type. In the main these coils are unsuitable to cope with the lower flow temperatures and the cyclical way in which Heat Pumps operate. The plate heat exchanger method offers a viable solution, which still allows for the delivery of mains pressure hot water from a stainless steel, 25 year guaranteed vessel. 11

RM nviroyl System Options... N nviroyl for any system design Heat transfer rates at a low primary temperature of typically twice that of a standard coil. Prevents excessive cycling of the heat pump thus improving efficiency and reducing wear and tear due to stop start operation. llows the stored water to be brought up within a couple of degrees of the flow temperature without cycling. Improves stratification within the hot water. Heat transfer can be tuned to match the heat pump by varying the secondary flow rate. In hard water areas allows the heat exchanger to be descaled or replaced easily. The cylinders have an OP of 0 & a WP of 1. Heatpump nviroyl nviroyl Pack ir Source Heating ircuit This method of piping allows the nvirocyl cylinder to be used on its own in conjunction with a buffer store for space heating applications. Heatpump & Solar Solar Panels This method of piping allows the nvirocyl cylinder to be used in conjunction with solar panels as well as a buffer store for space heating. nviroyl nviroyl Pack ir Source Heating ircuit oiler Heatpump & oiler This method of piping allows nviroyl nviroyl Pack ir Source Heating ircuit the nvirocyl cylinder to be used in conjunction with a boiler that will contribute along side the ir Source to space heating. 12

nviroyl Technical Specification... PROUTS SIN WITH RNWL THNOLOY IN MIN irect nviroyl Indirect nviroyl I H Size 150 192 222 692 742 n/a 890 1102 180 192 222 692 742 n/a 1078 1290 210 192 222 692 819 1159 1266 1478 Size H I 210 192 222 692 1039 1079 n/a n/a 1266 1478 250 192 222 692 1139 1179 1259 1409 1516 1728 300 192 222 692 1139 1179 1349 1609 1829 2041 250 192 222 692 959 1409 1516 1728 300 192 222 692 1109 1609 1829 2041 Solar direct nviroyl Twin coil nviroyl I H K J I H Size H I 250 192 374 470 530 692 1109 1409 1516 1728 300 192 374 470 530 692 1109 1609 1829 2041 Size H I J K 250 192 374 470 530 692 1109 1409 1516 1409 1516 1728 300 192 374 470 530 692 1109 1609 1829 1609 1829 2041 13

RM Solar Thermal... renewable solutions for modern housing RM 10 The standard Homelow10 panel sits at the head of the collectors in this range and is one of the most popular panels sold in the market place. It links both quality, performance, and guarantee (10 Years) with a cost effective sales price due to RM s agressive buying policy and low overheads. The Panel is a popular choice on new build as well as existing domestic installations and because the panels can be fitted 10 in series, they are also suitable for use in commercial applications and swimming pools. Like the rest of the Homelow10 range this panel can be fitted to all roof types, flat or pitched and we even have an frame available for gable end wall mounting. lso available are full in roof flashings to suit all tile types. RM homeflow20 The RM Solar Homelow20 panel is a world leading, vertically mounted flat plate collector. This panels has been constructed using top quality materials and manufacturing techniques which results in an unbeatable 20 year guarantee. This guarantee offers any customer many benefits, peace of mind, real payback opportunities, as most panels on the market only have a 10 year guarantee or less. The Homelow20 also has a much smaller carbon footprint thanks to its longevity of life. The panels are designed to have a 35 year life span. Like the 10 the panels can be mounted to virtually any roof type and are available with in roof flashings suitable for any standard roof coverings. Overall rea (m 2 ) 2.09 bsorber rea (m 2 ) 1.92 perture rea (m 2 ) 1.92 Length (mm) 2030 Width (mm) 1030 Height (mm) 87 Weight (kg) 48.2 Maximum Working Pressure 10 ar fficiency (%) 78.6 Thermal Loss (W/m 2 k) 3.62 14

or cylinder information go to: www.rmcylinders.com or solar information go to: www.rmsolar.com RM ylinders Ltd 4 Valencia Park ilcar Way Wakefield uroport astleford West Yorkshire W10 5QS Tel: 01924 228 999 ax: 01924 228 990 mail: sales@rmcylinders.com www.rmcylinders.com