Operation Manual. Pharmaceutical Refrigerator HYC-68/68A

Similar documents
Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-68/68A/118/118A. Picture:

Operation Manual. Pharmaceutical Refrigerator

Medical Refrigerator

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Chapter 5 Inspection and maintenance

Service Manual. Pharmacy Refrigerator(2~8 ) Model:HYC-940/940F. Picture:

RCM-77. Instruction Manual. G-Series Cooler. Manual is for the following model: RCM-77-N23EB. U.S. Patent No. 8,215,125 RECHARGEABLE COLD MERCHANDISER

RCM-2. Instruction Manual. G-Series Cooler. Manual is for the following models: RCM-2-N13EB. **Patent Pending** RECHARGE COLD MERCHANDISER

Pharmaceutical Refrigerator Operation Manual Model: HYC-260 HYC-360 HYC-290 HYC-390

RCM-77. Instruction Manual. G-Series Cooler. U.S. Patent No. 8,215,125 RECHARGE COLD MERCHANDISER

EFC 211 Fan Control USA CAN. ... Chapter 5. Start Up and Configuration. Maintenance and Troubleshooting... Chapter 6. Job Name: Installer:

EasyStart Select. Visit for more technical information and downloads. Eberspächer parking heaters

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

INSTRUCTION MANUAL PORTABLE FRIDGE/FREEZER. Models: RVX-35 / RVX-45 / RVX-50 RVX-55 / RVX-65 / RVX-75

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

DOUBLE DOOR FREEZER.

IKS..10,..20 / IK..00 / EK..10 from Index 20. IKS..14,..24 / IK..04 / EK..14 from Index 20, with 4-star freezer compartment

Combined Refrigerator and Freezer Operation Manual

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

Service Manual. Solar Direct Drive Vaccine refrigerator. Haier Medical and Laboratory Products Co,.Ltd. Model:HTC-60H & HTCD-160.

REFRIGERATOR P H A R M A C Y.

Refrigerator KE T

RG57F3(B)/BGEFU1 Wireless Remote Controller. Service Manual

SERVICE INSTRUCTION. DYNAMIC COOLING with 0 zone REFRIGERATION. Fridge/freezer with. Publication number

Freestanding Wine Cooler Instruction Manual

Warmette Blanket Cabinet Warmette Dual Cabinet. User Manual

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

Parts introduction FRONT BACK

Air Conditioner Features...8 Operating Instruction Care and Cleaning...17 Before You Call...18 Major Appliance Limited Warranty...

Pharmaceutical Refrigerator Operation Manual

REFRIGERATOR M E D I C A L.

Main switch Granules collecting device

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

OPERATING MANUAL Enertronic Control System 2

ST Wiring diagram. Product description. Four-stage controller. Order number

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

INDUCTION COOKTOP RHAI Operation Manual

HMCI 125F-EH MOVABLE TYPE AIR CONDITIONER WITH OZONE-FRIENDLY R410A REFRIGERANT USER S MANUAL CAUTION:

Medical Refrigerator DW-25H SERIES

Biomedical Freezer 37 38

Advance Blood Storage system from Meditech

MDX. Non-Cycling Refrigerated Compressed Air Dryers with Intellidrain Condensate Drain Trap. Operation & Maintenance Manual

-86ºC-Freezer. Ultra-Low Temperature Chest freezers: MDF-792 MDF-592 MDF-492 MDF-392 MDF-293 MDF-192

TM585. Refrigerator - Freezer Operation manual. Contents

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

HYC-950L. Medical refrigerator M.R.C LTD. OFFICES: HAGAVISH 3, HOLON P.O.B. 111, HOLON 58100, ISRAEL TEL: FAX:

INSTRUCTION MANUAL FOR WINE COOLER

Laboratory. Incubato 80 liters. Réf : Français p 1. Version : 2105

SJ-XP580G. Refrigerator - Freezer Operation manual. Contents MODEL

Service Manual. FILE No.HMRSM

Vaccine & Pharmacy Upright Glass Door Refrigerators

Refrigerant Leak Detector

Multi-Lab REFRIGERATORS Frigidere medicale

Middle Static Pressure Duct Type

OPERATING AND INSTRUCTIONS MANUAL: B130/10/220H VACCINE REFRIGERATOR REV.1 (WITH TEMPERATURE HOLDOVER FUNCTION)

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

G-10s. Instruction Manual. G-Series Cooler UPRIGHT COOLER. Part No.11IPA

Safety, Consistency And Reliability; Leading In The World And Recommended By China Marrow Donor Program

Operating Instruction

Sunleaves Air Conditioner

KDIR TROUBLESHOOTING. Middle Static Pressure Duct Type SERIES

Haier Medical and Laboratory Co., Ltd.

4.6 Cu. Ft. Deluxe Wine Cooler

GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

AG2TEMP PRESTIGE SPECIAL REFRIGERATOR Model: AG2TEMP SPECIAL

testo 550 Digital manifold Instruction manual

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Downloaded from manuals search engine

testo 550 Digital manifold

Pharmacy Refrigerator

Checkout Procedure Manual

Refrigerated Incubators / Environmental Testing Chambers

Upright Chromatography Refrigerators

/2010 US/CA

Utopian Portable A/C

Visit for more technical information and downloads.

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Mobile Type Air Conditioner

Temperature Monitoring

EURO APPLIANCES BY EUROSTYLE GROUP

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

Operating instructions Page 14. Refrigerator Read the operating instructions before switching on for the first time

Dual-Hose Portable Air Conditioner User Manual

Setup instructions. Honeywell GAS DETECTOR. Overview. Accessories The instruction x1 Plug dowel x2 Screw x2 Double-sided adhesive tape x2

TABLE OF CONTENTS REFRIGERATOR-FREEZER. Model No. NR-BN34FX1 Model No. NR-BN34FW1

TOYOTA CAMRY/CAMRY HV BODY SIDE MOLDING Section I - Installation Preparation

OPERATING and MAINTENANCE INSTRUCTIONS Models: H138NPS36CLCMQRL i7 Hot Cabinet

2-ZONE EASYFIT INTRUDER ALARM

GH10PA USER MANUAL. Program version 01 MANUAL FOR CONTROLLER FOR CONTROLLING CENTRAL HEATING BOILERS FIRED WITH PELLETS AND OATS

Instructions for Combo heat press machine

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

Operator Guide. Publication No. OI /97-Eng. KODAK Automixer II Plus

TOYOTA SIENNA MY LOWER DOOR MOLDING Preparation

PRIMUS IMPORTANT. User Manual and Product Specifications. Portable Fridge/Freezer. Part No. PRI18LP - 18 Litre. Read instructions before operation.

Lite. Installation Manual User Guide

Transcription:

Pharmaceutical Refrigerator Operation Manual HYC-68/68A Read the Operation Manual carefully before using your appliance. Keep the Operation Manual in a safe place. Appearance, color and layout of the door may vary.

HYC-68 68L HYC-68A 68L Insulation door Glass door 2 2 R600a 10 11 12 32kg 10 32kg HYC-68 84W HYC-68A 84W

1) The appliance should be connected to a dedicated socket for 220V/50Hz power supply.allow some time lapse before loading the appliance. 2) The warning sound signal may be heard when the appliance is first connected to the power source and can be inactivated by pressing the buzzer buttom. The warning indicator stays on until the temperature of the test bottle sensor reaches 5 2. 3) Ensure that the two test bottles are filled with 10% glycol solution.(see article 4,section installation on page 6). 4) The appliance is preset during manufacture for operation temperature 2~8.

8

Control pannel Battery switch Function and Instruction For 2-8 Refrigerator 5 Adjust alarm temperature range: See fig #1 Pharmaceutical Two methods set high temperature alarm HA and low temperature alarm LA Press Alarm button for 10 seconds. LED display code HA,press SET button again(quickly),code HA flash, adjust the set- temperature by both pressing + and buttons and increment 1 C, adjustment range shouldn't be 6 C higher than pre-set cabinet temperature,press Alarm button to return the former menu(each press of Alarm button will return one step back to former menu until display cabinet temperature) and LED display HA Press both + and to choose another parameter LA, LA setting method like HA, and its adjustment range shouldn't be 6 C lower than pre-set cabinet temperature. 6 Defects display Inner light The control panel only can display one sensor error, when the sensor error happens.led display E1,and alarm at the same time. The refrigerator will keep working according to the defect safty model,and you should put the stored goods to other refrigerator as soon as possible,and cantact the after-sales department quickly. 7Inner light In order to see the stored goods clearly, a LED light has been installed in the cabinet. You can control light on or off by light button to save energe,please turn off the light after observing the stored goods in the refrigerator. The light is on when the door is open; The light is off when the door is closed. Door handle Shelf Casters

Function and Instruction For 2-8 Refrigerator Pharmaceutical 1.Control panel The operation mode and temperature are displayed on the control panel. Pressing the button on the control panel will display the current temperature and warning data. 1 Microprocessor temperature controller Adjust the cabinet temperature easily by the microprocessor temperature controller in control panel installed on the top of the refrigerator.don't do any adjustment in the first 30 mins when you first power the refrigerator. LED displays the cabinet temperature. 2.Battery switch Rechargeable battery switch for control of power interruption. Position 1 for On, and Position 0 for Off. Caution: The switch must be set to position On while the appliance is in operation. Caution: Set the battery switch to position Off if the appliance is not used for a long period. 3.Door handle Elegant design and unique finish. 2 Temperature adjustment: See fig #1 Fig 1 4.Casters Casters designed for free movement of the appliance. Factory pre-set to 4 C. Adjustable temperature control range +2 C to +8 C Set cabinet temperature: Press SET button and loosen quickly,led display the pre-set temperature and flash. Adjust the cabinet temperature with the buttons + or and increment 1 C when the temperature flash.automatically quit the system after 10 seconds no operation and display the cabinet temperature again (no flash).the cabinet temperature will reach pre-set temperature after a while. High and low temperature alarm It will alarm when the cabinet temperature is higher than the high alarm temperature or lower than the low alarm temperature (buzzing and light flash). Press Alarm button to end the buzzer, but light flash going on until the cabinet temperature renew to the alarm temperature range. 5.Inner light LED 3 Check alarm temperature: See fig #1 Press both Alarm and + button to check high temperature alarm, loosen buttons to return cabinet temperature display. Press both Alarm and button check low temperature alarm, loosen buttons to return cabinet temperature display. 4 Check recent highest and lowest cabinet temperature: See fig #1 Press both SET and + buttons to check recent highest cabinet temperature, loosen buttons to return cabinet temperature display. Press both SET and buttons to check recent lowest cabinet temperature, loosen buttons to return cabinet temperature display.

Preparations for operation Remove all package assembly. Including foam pedestal and adhesive tape which is used to fix accessories. Check off attached accessories and data. Check the materials including in the box against the packing list. If there is any discrepancy, please consult the store where you purchased the refrigerator. Place the refrigerator on a suitable position. Please refer to the above-mentioned Place environment. Clean the refrigerator before operation. For more information, please refer to the cleaning section. Standstill. After placing the refrigerator flat and completing the cleaning, do not electrify the refrigerator, until after 30minutes of standstill so as to ensure smooth operation of the appliance. ATTENTION To facilitate the inquiry, please copy the refrigerator model and factory number onto the warranty.