Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Similar documents
Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Chromatographic Air circulated Refrigerator, two-door TC 603

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Laboratory Refrigerator/Deep Freezer TC 802

Chromatographic Air circulated Refrigerator, two-door TC 603

DOUBLE DOOR FREEZER.

REFRIGERATOR M E D I C A L.

Multi-Lab REFRIGERATORS Frigidere medicale

Constant climate chambers

ULTRA.GUARD ultra low temperature freezer

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Constant climate chambers

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Constant climate chambers

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

PR / MP I Laboratory / Medicine

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

NEW GENERATION. Efficient use of valuable space INCUBATORS

Platelet bags constant shaking for long periods of time.

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

MEDICAL REFRIGERATORS

Laboratory refrigerators

BIOMEDICAL REFRIGERATORS

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Internet. Climate rating definitions. Customer service.

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Cold chain monitoring technologies. Facility monitoring

Laboratory Refrigerators and Freezers

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

Laboratory Refrigerators and Freezers. Also with explosion-proof interior

Monitoring Solutions

Laboratory refrigerators and freezers

Long Term Storage Cabinet

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

Walk in Freezer. Comfortable work environment

Blood Bank Refrigerators

Medical Refrigerators

Stability Chambers & Rooms

Mobeye CM2410 GSM fire alarm communicator

Refrigerated Incubators / Environmental Testing Chambers

FITOCLIMA 600 & 1200 STABILITY

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

Constant climate chambers

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Refrigerators and freezers Research and laboratory 2018

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Laboratory Refrigerators and Freezers. Also with explosion-proof interior intrinsically safe, independently tested as well as certified.

Laboratory Refrigerators

SCAN200E USER S MANUAL

Environmental simulation chamber for complex alternating climate profiles

Heated and Refrigerated Incubators

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

Plant growth chambers

Air & Water Heat Pump R832

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Laboratory thermostatic chambers

Dew point set DS 400

FITOCLIMA 600 & 1200 STABILITY

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

ICH260C. Climate Chamber. Product specification

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

ICH110. Climate Chamber. Product specification

Protection, safety, reliability. And more.

Benefit Cabinets. Performance. Efficiency

Constant climate chambers

Benefit Cabinets. Performance. Efficiency

Model KBWF 240 Growth chambers with light and humidity

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

PORTAL USER MANUAL. Mobeye WaterGuard-FS. Float sensor CM2300FS. SW version 5.n

ICH750L. Climate Chamber. Product specification

Best Freeze Drying Solutions

DATAssure. Laboratory wireless alarm & monitoring system

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

OPERATING INSTRUCTIONS. G214 Software - Version 4

600 Range Dialer Installation Manual. Version 1.0

Plasma Thawer. model WPFD. Comformity with: GMP CNT JACIE FACT. WPFD Plasma Fast Thawer Medical Device - CEE 93/42

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

EviKontroll Silo. Monitor Your Grain Anytime, Anywhere

EL-USB-TC Thermocouple Data Logger with USB Interface

Refrigerated Incubator Model and Operating Instructions

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Transcription:

External Dimensions: B = 530 mm D = 640 mm H = 1600 mm Inside Dimension: Useful space on top Useful space at the bottom B = 450 mm B = 450 mm D = 535 mm D = 535 mm H = 530 mm H = 530 mm Capacity: 280 l Temperature range: 2 C to 8 C 8 C to 20 C Optional: other temperature ranges (Ill. similar) Housing (high size) galvanized sheet steel with high quality white coating. With 4 feet, height adjustable. Optional: Set of 4 castors of stainless steel (Backplane, as well as top and bottom side of the cabinet of galvanised sheet steel) Interior space Inner case of galvanized sheet steel with high quality white coating. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Optional: of stainless steel Insulation high density foamed-in-place polyurethane, with a thickness of 40 mm. CFC-free Circulaton air cooling for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Door 2 pcs. three-layer thermally insulating glass door (arranged on above the other), supplied as standard with right hand hinge, also available with left hand hinge at no extra cost.. Grease resistant magnetic seal. Optional: with door lock (one lock for 2 doors) with solid doors Interior fittings 4 pcs. Grating-type shelves (dim.: 400x500 mm), white coated (max. 4 shelves possible) Interior lighting with automatic ON/OFF micro switch Optional: Stainless Steel drawer compartments, with 2 lengthwise dividers (max. 4 drawers possible) with telescopic-type guides on rollers with stops, Drawer dimensions: 380x450x77 mm (BxDxH) Usable width between the lengthwise dividers: 110 mm (lengthwise dividers easily removable) technische Änderungen vorbehalten Seite 1 von 8

Control system located above the door 2 pcs. High quality electronic temperature controller Actual value permanently displayed. Set value adjustable digitally by switches. Working range 1 from 2 C to 8 C Working range 2 from 8C to 20 C (assuming the ambient temperature is approximately 4 C above the setpoint). Temperature accuracy +/- 1,8 C after stabilisation (with 50% of loading) Acoustic signal when the set value is undercut or exceeded Potential-free connection socket for extern alarm indication Optional: Temperature regulator TC 2015 Refrigerating unit 2 pcs. fully hermetically sealed, forced ventilation, fitted on vibration - absorbing mounts (ambient temperature max. 32 C), low noise (48 dba/1m), energy saving compressor with high quality vaporisation system. Refrigerant: R 404a Defrost automatically with thermal and time limit. Condensate evaporation in heated tray. During the defrost period, the temperature inside the cabinet (only the air temperature not the stored goods) will arise for a short time. Electrical Data Power supply Power input Energy consumption Fuse Power cable: 230 V/50 Hz (optional: 60 Hz) /single phase 310 W 2,6 KW (24 hours.) 10 A 1,5 m with schuko plug Packing details (palletized) Dimensions: ca. 65x72x192 cm Net weight: 155 kg Gross weight: 140 kg Country of Origin: European Community Customs clearance code: 8418 5090 technische Änderungen vorbehalten Seite 2 von 8

Special Equipment and Accessories: Touchscreen temperature controller, TC 2015 Language in German / English adjustable Touchscreen Display, size 12,5 cm (5 ) PT1000 temperature sensor for better temperature control accuracy Digital temperature setting and display with an accuracy of 0.1 C Power supply of 100-240V, 50-60Hz Password protected to prevent manipulations Data import/export via USB or Ethernet Alarm - Noticeable optical alarm signaling by red / blue flashing screen - Audible alarm Mute the audible alarms, with continuous warning indication on the display and automatic return after 3 minutes when the alarm situation still exists - Alarm acknowledgment with password protection Acoustic and optical alarm indication when - High and low temperature (variably adjustable) - Door open - alarm, (adjustable) - Power failure - Temperature sensor failure - Defrost-time transgression (variable adjustable) - Optional: cooling machine monitoring with overheat protection Alarm memory (not deleted) for the last 100 alarm conditions, with the possibility of review on the display and archiving the data via USB or Ethernet. Memory can not be deleted. Event memory In the event log all the operations of the controller are saved, such as: - Doorways - Parameter changes - Cooling equipment function, etc - Storage for approximately 4 weeks, with the possibility of review on the display and archiving the data via USB or Ethernet. Graphical display of the temperature profile in the display Illustration of the actual value and if requested of the product sensor on the display and archiving via USB or Ethernet. View period freely selectable. technische Änderungen vorbehalten Seite 3 von 8

Network Connection 2 Ethernet ports 10/100 Mbps available. This interface can be accessed directly on the log data of the controller to import in the software. NO/NC contact Alarm signal time delayed (adjustable) Language: English / German, other languages on request Maintenance message: Notification that maintenance should be carried out. Test facilities for Alarm limits and battery charge status In the housing of the temperature regulator there are all relevant components for using the cabinet. Plug-in connectors of the electrical supply pipes enables a service friendly exchange. Optional - Battery Module In case of power failure self-contained supply of the temperature controller with a powerful battery. All control functions are saved for about 72 hours. - 0..20 ma Output - WLAN-Module - Interface, RS 485 (galvanically isolated) - Software This software enables you to check at a glance several cooling units. It was designed to be user friendly and enables you to process your data in an intuitive manner. - Alarm system - Independent product sensor for reference measurement - Product protection against low temperatures. By dropping below the setpoint value, the cooling machine will switched off technische Änderungen vorbehalten Seite 4 von 8

GSM Modul Connecting to the potential-free output. In case of an alarm either a message or a call will be sent automatically. Archiving of 1000 phone numbers is possible. The GSM module is equipped with a rechargeable battery. Automatic alert via SMS when the credit has been used on the SIM card. 6 units can be connected per module. The SIM card is not included Round Chart recorder to record temperature, permanently installed in control panel. Comes as standard with battery back-up power supply for continuous operation (mains independent).the replaceable recording discs are suitable for 24 hours or 7 day periods. The actual temperature is plotted with a black felt tip pen on the chart. Internal temperature measurement. Measurement range: -10 C to 40 C The unit comes with 100 round charts (day or week) Door lock including 2 keys Optional: electronic door lock, via temperature controller TC 2015 Mains socket / damp room design Installed inside the cabinet, 230 V, 50 Hz ON/OFF by switch on control panel Cable port with cover (approx. 40 mm ). Cable port with PG-gland for example to create access for operator measurement lines, etc. Optional: with separate sensor kind and version as desired by the customer Dew water collector tank for manual emptying (i.e. for using this cabinet in operating rooms and clean rooms) technische Änderungen vorbehalten Seite 5 von 8

Wireless data logger, complete For independent temperature recording consisting of: Wireless data logger, SPY RF U1 1-channel for Pt100, 4-20mA / 0-1V / contact on-off, with display Measurement accuracy at 23 C: +/- 0,3 C Resolution 0,1 C Battery: Lithium Battery Recording interval: 1 sec. to 90 minutes Internal memory: 10.000 measurements Usable range: 1km LOS Communication: via radio 868 Mhz Power: 25 mw incl.1 pcs. Sensor of stainless steel, Ø 4,0mm L=30mm Pt100 class A with plugged cable of PTFE Measurement area: -200 C +200 C Length: 3 meter Optional: 8 meter Delivery contents: wall mounting holder and plug protection Software - Basic Version for single user - Maintenance of multiple Wireless data logger - collect the recorded data of the Wireless data logger - Back up data (tamper-proof) - Prepare the data in terms of graphics or charts - Excel exportable - Maintenace of alarms via potential free contact at the Modem - or Alarmsystem (SMS, phone call, blinking light, buzzer) SPY RF USB-Modem for data transfer to the PC via USB-connector - Communication with infinete numbers of Wireless data logger - Remote alarm via integrated potential contact - including wall mounting holder technische Änderungen vorbehalten Seite 6 von 8

Optional: Sensor of stainless steel Ø 4,0mm L=30mm Pt100 class A, with plugged cable of PTFE, Measurement area: -200 C +200 C Length: 8 Meter SPY RF Relay (Repeater) - Allows the data transfer of the data logger about bigger distances - Can transfer dates of one or several SPY RF data logger - Electricity supply about power supply unit and battery in case of power failure - with 2 output ranges: 25mW to communicate with the data logger and 500mW to communicate with the modem. - Delivered with wall mounting fixture - Ambient temperature: from -10 C to +70 C SPY RF Alarm - realtime alerting - i.e. by limit exceeded or power failure - Local warning - Integrated acoustical and optical Alarm - Power supply via external power adapter and spare battery in case of power failure - Button for local alarm quitt - Relais output for remote alarm (GSM-Modem, telephone dialer) - including wall mounting holder SPY RF Telephone dialer - In the speech modus it called up to 6 different subscriber and informed them about the kind of failure - This ergonomically linguistic aid provides high operational ease. - requires an analogue phone line - Individual adjustment of identification, alarms and alarm quitt - requires an external power supply (included) GSM-Modem I for switch contact For use with: Software - Basic Version and SPY RF USB-Modem, or SPY RF Alarm - Enables to send SMS messages - Modem registered also power failure and send SMS immediately. technische Änderungen vorbehalten Seite 7 von 8

Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance with the set requirements and government regulations. The IQ documentation is worked out by us especially for the delivered machine and is made available to you. The IQ documentation has to be carried out by the customer itself. OQ (Operational Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole operating range are working as intended in accordance with predetermined limits. The OQ documentation is worked out by us especially for the delivered machine and is made available to you. The OQ documentation has to be carried out by the customer itself. CQ (Calibration Qualification) Definition: Documented proof that critical measuring equipment in the intended range in accordance with predetermined tolerances operate reliably under current operating conditions Checking the temperature in the cabinet 1 Temperature on 3 different measuring points (measured with calibrated PT 100 sensor) evenly located on the shelves. Inspection time 6 hours, open door after that of 30 seconds. The inside temperature of the cabinet must have been stabilized itself within 1 hour on the set point temperature. The measurements are carried out in the empty state. The temperature measures are carried out in our company, represented graphically and provided to you. The values may not dropping below or above the tolerances given by us. (Additional measuring points on request) PQ (Performance-Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole workspace under current working conditions (with product) provide the requested services The calibration described above is carried out under real conditions on site. The values may not dropping below or above the tolerances given by us. technische Änderungen vorbehalten Seite 8 von 8