KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Similar documents
OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST TEL NO: ORDER NO: CONTRACT NO:

MODEL YVAA EQUIPMENT PRE-STARTUP AND STARTUP CHECKLIST CUSTOMER: LOCATION: ADDRESS: CUSTOMER ORDER NO: PHONE: JCI CONTRACT NO: JOB NAME:

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

Liebert CRV Warranty Inspection Check Sheet

PWEE Technical Data Sheet

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

Parallel Rack Systems

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

RLNIE with INNOVATOR II

P/N _F NSF Certified June 2010

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

RL with INNOVATOR II No Heat Doors

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

PS SERIES PARALLEL RACK SYSTEM GLYCOL CHILLER START UP GUIDE 11/03/2015 Rev 00

USER'S MANUAL PGE Single Package Rooftop

YCIV Hz & Hz

FG-L Technical Data Sheet

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

PS SERIES PARALLEL RACK SYSTEM START UP GUIDE

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

RM with INNOVATOR Doors

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Engineering Plan Views

MD Medium Temperature Self Contained Open Vertical Merchandisers

Service Manual. ETL Blast Chiller Series

User s Information Manual

BCH Medium Temperature Merchandisers

Subcooling is defined as the point at which liquid is cooled below it s condensing temperature. Example: Refrigerant R404A

EcoVision Door Manual

SELF-CONTAINED FLAKER

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

User s Information Manual

AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

KR Electrical Defrost Unit Coolers (PN E108318_E)

Rev B, 9/2/2009. Kodiak Chiller Overview

RLT with INNOVATOR Doors

GLD-30 Gas Leak Detector

DLCLRA. INSTALLATION INSTRUCTIONS Outdoor Unit Single Zone Ductless System Sizes 36 to 58 TABLE OF CONTENTS

Installation Instructions

Nosing Heater. Return Grill Heater

SA Series Startup Form

Bottom Mount Refrigerator---Technical Information

DIGITAL DIPLOMAT 20 and 32 oz POPCORN MACHINE SERVICE MANUAL

DIGITAL DIPLOMAT 48 and 60 oz. POPCORN MACHINE SERVICE MANUAL

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Trouble Shooting Guide PWA, 3-phase (D10571)

Installation, Operation and Maintenance Manual

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

Hoshizaki America, Inc.

INSTALLATION, OPERATION & MAINTENANCE MANUAL BERG TEMPERATURE CONTROL UNIT

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

INSTALLATION AND OPERATION MANUAL

Installation Instructions

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

True Auto-Purge System

SECTION 7 AIR CONDITIONING (COOLING) UNIT 41 TROUBLESHOOTING

Warm Case Troubleshooting Guide 9/18/2014

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Hoshizaki America, Inc.

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

Hoshizaki America, Inc.

Drop-In Refrigeration System

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

User s Information Manual

INSTALLATION INSTRUCTIONS

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

CAUTION. No-Load Performance, Controls in Normal Position

Surna 25-Ton Chiller Operating & Maintenance Manual

SA Series Start up Report

Transcription:

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum P/N 1H52918001_B Version 1.1 May 2011 P/N_1H52918001_B

P/N 1H52918001_B iii TABLE OF CONTENTS I. Overview..................... 1 II. Unit Nomenclature............. 1 III. Dimensions and Weights........ 1 IV. Receivers..................... 1 V. Field Supplied and Installed Water Components..... 2 VI. Accessibility.................. 2 VII. Rigging and Hoisting........... 2 KRSCPLIF Shipping Blocks.... 2 VIII. Electrical..................... 3 IX. Start Up and Component Descriptions........ 3 X. Safe-NET II Control Settings and Operation... 5 Exmple of Cabling from Controller to Self-Contained Units......... 5 Setting Safe-NET II Without Remote Control............... 6 Setting Safe-NET II With Remote Control............... 8 Low Temperature Wiring Diagram............. 10 Medium Temperature Wiring Diagram............. 11 WARRANTY IMPORTANT KEEP IN STORE FOR FUTURE REFERENCE Quality that sets industry standards! Corporate Headquarters 12999 St. Charles Rock Road Bridgeton, MO 63044-2483 2700 Crestridge Court Suwanee, GA 30024 1-770-921-9410 U.S. & Canada 1-800-922-1919 Mexico 1-800-522-1900 www.hussmann.com 2011 Hussmann Corporation

iv KRSCP REVISION HISTORY REVISION B April 2011 Adds medium temperatue operation; adds compressors. REVISION A December 2010 Original Issue ACRONYMS KRSCP Self Contained Unit; Single Compressor Protocol and Krack Unit Cooler CPC Computer Process Controls SCP Single Compressor Protocol P/N 1H52918001_A U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 1 GENERAL I. Overview II. KRSCP Unit Nomenclature This addendum is to be used in conjunction with the standard Protocol Service and Installation Manual as well as the appropriate unit cooler Installation and Operating Manual. Although similar in content, this addendum will only cover the differences from the other existing manuals. KRSCP models are designed to use R404A refrigerant and to operate at 208 volts, so the nomenclature will not include descriptors for refrigerant or voltage. Nomenclature inter - pretation is shown below: The KRSCP units are self-contained systems incorporating the SCP, or Single Compressor Protocol condensing unit with a Krack Unit Cooler. The KRSCP unit is pre-piped, wired, and charged with refrigerant so that it can be installed in the ceiling of the walk-in, ready to plug in and connect water lines. These units are controlled by the Safe-NET II electronic control. It communicates with a CPC controller for monitoring and communication. The separate units can be daisychained together with communication cables to a single CPC controller. The walk-in temperature is controlled by cycling the compressor of the KRSCP unit based on the coil entering air temperature sensor. This sensor is located near the top of the unit cooler coil face in the center of the coil. Another sensor is located on a return bend of the unit cooler coil and is used for defrost termination in the low temperature units. Fan delay is controlled by a standard clamp-on thermostat, also mounted on a coil return bend. The Safe-NET II control has pre-programmed default settings for Medium Temperature, Frozen Food and Ice Cream applications. The water-cooled condenser is designed to operate with a water-glycol mixture, supplied at a temperature between 60 and 105 F. Flow rate can be controlled by adjusting the control valve included in the unit. III. Dimensions and Weight Maximum Length Height Depth Shipping (in.) (in.) (in.) Weight * 60 36 35 350 lb. * UC = KR26E model IV. Receivers All KRSCP units include a factory installed receiver. The KRSCP units are pre-charged at the factory: 7 lbs for the KRSCPMIB; 6 lbs for KRSCPLIE; and 7 lbs for KRSCPLIF. The receiver total capacity is 8 lbs, based on 80% liquid fill at 105 F. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. KRSCP

2 KRSCP V. Field Supplied and Installed Water Components The KRSCP unit comes with an installed flow control/shutoff valve. The water connections are made outside of the SCP condensing unit and 3 /4-inch barbed fittings are factory installed. There are two 3 /4-in. 8 ft. (19 mm 2438 mm) water hose lines and two clamps shipped with the unit to make the field connection. A 16-20 mesh strainer (1 mm) is required immediately upstream of each SCP unit. VII. Rigging and Hoisting The installer is responsible for ensuring that the equipment used to move the KRSCP unit is operated within its limits. Under no circumstances should the unit panels or the unit cooler be used for lifting or moving the unit. The condensing unit and unit cooler are both mounted to a 4-inch thick insulated panel, which has internal cross-bracing. There are four eyebolts mounted to this panel that should be used to lift the entire self-contained unit (see below). The panel of the KRSCP also has built-in cam-lock fittings to facilitate installation in the ceiling of the walk-in. Only the KRSCPLIF has shipping blocks located under each compressor foot, at the outer corner. The blocks should be removed after the unit is set. Loosen the nut on top then pry the foot up enough to push the block out. After all blocks are removed, the nuts must be retightened (see photo below). The water flow control valve may need to be adjusted upon installation. It must be set to provide sufficient flow to keep the condensing temperature below 115 F (46 C). This should equate to a maximum outlet water temperature of 115 F (46 C). Note: If startup occurs during low ambient (winter) conditions, water inlet temperature will be lower than during the summer. See the Engineering data sheet for water flow rates for summer conditions. VI. Accessibility The KRSCP units are serviced from the front, with the cover lifting up to provide access to the control panel and internal components. The cover requires a 22 inch (559 mm) clearance above the SCP unit to fully open. Angle spacer mounted under front left foot P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 3 VIII. Electrical Refer to the Engineering data sheet supplied with the unit for the correct receptacle and power requirements. An electrical diagram is included here, on Page 10 or Page 11, and with the unit. When the unit is shipped with the optional power supply cord and plug, it extends out of the condensing unit, is bundled and attached to the top of the assembly. The cover of the unit must be raised and the control box cover removed to access the main disconnet switch (circuit breaker). The power supply cord plug consists of 3 power leads, a neutral, and a ground wire, and requires a matching receptacle. If the cord / plug option is not selected, refer to the wiring diagram on Page 10 or Page 11 for field connection locations. ALL WIRING MUST BE IN COMPLIANCE WITH NEC AND LOCAL CODES. IX. Start Up and Component Description WORK SHOULD BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN. Follow all instructions in the main Protocol and Unit Cooler Manuals. PRE-STARTUP CHECK LIST: Is the case connected to its proper nameplate power supply? Is the power on at the breaker panel? Is the water to the condenser on? HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A.! WARNING LOCK OUT / TAG OUT To avoid serious injury or death from electrical shock, always disconnect the electrical power at the main disconnect when servicing or replacing any electrical component. This includes, but is not limited to, such items as doors, lights, fans, heaters, and thermostats. Is the chiller on and circulating water through the condenser? Check that there are no leaks from the connections for the condenser water. (Clamps may not have been tightened.) Are the evaporator fans free to rotate? Refrigeration line shutoff valves must be in the backseated (open) position. START UP Raise the condensing unit cover, then remove the electrical cover to gain access to the main switch on the condensing unit. Move the switch to the on position. Replace electrical cover. START UP CHECK LIST: The Safe-NET II control is located inside the control panel inside the condensing unit. Remove the control panel cover. CHECK the display on the Safe-NET II control, which should be displaying the unit cooler entering air temperature. LISTEN for any unusual sounds or events, such as evaporator fan blade interference, compressor trip on high head due to no (or inadequate) water flow to the condenser, circuit breaker trip, etc. KRSCP

4 KRSCP CHECK the fans to ensure they are running. CHECK that there are no leaks from the connections for the condenser water. Note: There is a random delay on initial system startup of up to 4 minutes to provide for a staggered start, to prevent high electrical circuit demand. This will cause a noticeable delay when starting up the unit and should be expected. AFTER STARTUP CHECKLIST: Following a 12 hour run after startup (balanced out): SET TEV SUPERHEAT according to the unit cooler Operating Manual instructions. CHECK entering air temperature. CHECK water connections to the condensing unit for any leaks or accumulation of water. VERIFY that the fans are running. (The fans will be off if the unit is in a defrost cycle. They will come back on shortly after the completion of this cycle. The fans have a delay thermostat to prevent fan startup at warm conditions.) INITIATE a defrost cycle and ensure the heaters are working properly. See the Safe- NET II instructions for how to force a defrost cycle. REPLACE the control panel cover. Are all inspection plates and covers properly replaced? REPLACE the condensing unit cover. INSPECT for any water accumulation due to incorrect or unsealed penetrations where electrical or other lines pass through the case insulated walls. DESCRIPTION OF COMPONENTS ON SCP UNIT The condensing unit is equipped with nonadjustable high and low pressure controls, a phase monitor, and an internal compressor motor protector for added compressor protection all in the control circuit with the compressor contactor coil. The high pressure control will open in the event of excessive pressures; for an example, the loss or reduction in condenser coolant flow. The high pressure control will open at approximately 395 psig. This control is manually reset by the actuation of the toggle switch located on the condensing unit. Move the switch to the off position and then back to on. The control will reset if the pressure has decreased below approximately 320 psig. If the compressor experiences an excessive load that causes a trip of its motor protector, this same method is used to reset the protection device. Move the toggle switch to the off position and then back to on. The low pressure control will open in the event the compressor is operating at pressure below its design operating conditions, such as in the case of a loss of refrigerant. This control is automatic and will reset when the condition is corrected. The KRSCPMIB includes a suction/liquid line heat exchanger to provide adequate superheat at the compressor suction side. This also subcools the liquid and increases the capacity as well. P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 5 X. Safe-NET Control Settings and Operation These instructions are written for normal walk-in applications, and provide optimum defrost, discharge air, etc., settings for normal store conditions. To change these operational settings refer to the Safe-NET II manual available on the Hussmann website http://www.hussmann.com/pages/welcome.aspx, or watch the series of nine YouTube videos beginning with http://www.youtube.com/watch?v=n9tu0fwpvky &feature=related Shown below is a schematic of the cabling from the self-contained units in the store to the CPC controller: Protochill CPC Controller A4 A4 A4 A4 A5 A5 A5 SC Unit SC Unit SC Unit SC Unit A5 SC Unit A5 A5 SC Unit SC Unit Frozen Food Merchandisers A4 SC Unit SC Unit SC Unit SC Unit SC Unit RL Merchandisers A5 A5 A5 A5 SC Unit Detail A SC Unit SC Unit SC Unit SC Unit Item A5 Cable A4 Cable Length 18 ft Field Installed Exmple of Cabling from Controller to Self Contained Units HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. KRSCP

6 KRSCP SETTING SAFE-NET II WITHOUT REMOTE CONTROL (Example: Unit Coolers with SCP Condensing Units) 1. Locate the Safe-NET II Control Display on the model of SCP that you have. The control is located inside the electrical box on the condensing unit.! W ARNING Opening condensing unit electrical box exposes personnel to electrical hazard and should only be performed by a qualified service technician! 2. Remove the Safe-NET II cover. Open the Safe-NET II controller using a small flat blade screwdriver to pop off the oval cover (this may be tight). SELECT Button UP Button SET THE PASSWORD. DOWN Button 4. Press the SELECT button. The display should read EASY, then dset and then the setpoint temperature. 5. Next press the UP button once until you see PASS. The display should alternate back and forth between PASS, and 0. 6. Press the SELECT button once. The 0 should be flashing. 7. Press the DOWN button until you reach 595. 8. Then press the SELECT button once. The password is set. The display alternates between PASS and 595. Password is set. READ NETWORK ADDRESS. 3. You will see three buttons on the control board as shown in the next photo. The SELECT button is used to scroll through menus, and to edit/confirm values. Use the UP or DOWN button to move to the next item in the menu or change the value of a parameter. Press the UP and DOWN buttons at the same will escape to the default display. 9. Press the SELECT button once. The display should read StUP and alternate between dset and the setpoint temperature. 10. Press the DOWN button 3 times. The display should alternate between Addr and the set network address. 11. IMPORTANT! Write down the network address! You will need to reload this address later. P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 7 12. If display is still cycling between Addr and the set network address, press the UP button 5 times and proceed to Step 15 13. If the display is displaying default temperature, press the SELECT button until the display reads StUP and then alternating between dset and the setpoint temperature. 14. Press the UP button twice. CHANGE THE CASE MODEL 15. The display should alternate between CASE and the set case model (for example, ucic, ucff or uccl). (Note: ucic is for a 10ºF ( 23ºC) setpoint, ucff is for a 2ºF ( 19ºC) setpoint, and uccl is for a +35 F (+1.6 C setpoint.) 16. Press the SELECT button once. The ucic, ucff or uccl should be flashing. 17. Press the UP or DOWN button to find the other case model to be selected. 18. Then press the SELECT button once. The display should read CASE, then ucic, ucff or uccl. 19. Press the DOWN button 6 times. The display should read rst. 20. Press the SELECT button once. The unit should reboot. REASSIGN NETWORK ADDRESS. 21. If the network address written from Step 11 is none, then proceed to Step 29 to skip reassigning network address and confirm the new case model. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. 22. While rebooting, the display should read SAFE for about 6 seconds then followed by -net for 6 seconds. Anytime during display reading SAFE or -net, press the DOWN button. 23. Display continues reading SAFE, then -net, then 10.50, then the new selected case model (ucic, ucff or uccl). 24. After displaying case model, the display reads Addr and then flashes none. (Default no communication network address.) 25. Press the UP or DOWN to navigate to the address which was written down in Step 11. 26. Press the SELECT button once; the display should alternate between Addr and the new assigned network address. 27. Press DOWN button once when display is alternating between Addr and the new assigned network address. The display should read rst. 28. Press the SELECT button once. The unit should reboot. CONFIRM THE NEW CASE MODEL. 29. Display reads SAFE, then -net, then 10.50, then the new selected case model ucic, ucff or uccl) followed by the temperature reading. 30. Press the SELECT button once. The unit should display EASY, then dset, then 10 for ucic, 2 for ucff or +35 for uccl. 31. The KRSCP default parameters have been reloaded. KRSCP

8 KRSCP 32. In a few seconds the display will return to the temperature reading. SETTING SAFE-NET II WITH REMOTE CONTROL (The Safe-NET II cover does not have to be removed.) SET THE PASSWORD. 1. Press the SETUP key. (upper left corner) The display should read StUP and alternates between dset and the setpoint temperature. 2. Press the UP ARROW key once until you see PASS. The display should alternate back and forth between PASS, and 0. 3. Press the ENTER key once. The 0 should be flashing. 4. Press the DOWN ARROW key until you reach 595. 5. Then press the ENTER key once. The password is set. The display alternates between PASS and 595. Password is set. READ NETWORK ADDRESS. 6. Press the SETUP key once. The display should read StUP and alternates between dset and the setpoint temperature. 7. Press the DOWN ARROW key 3 times. The display should alternates between Addr and the set network address. 8. IMPORTANT! Write down the network address! You will need to reload this address later. 9. If display is still cycling between Addr and the set network address, press the UP ARROW key 5 times and proceed to Step 12 10. If the display is displaying default temperature, press the SETUP key once and the display reads StUP and then alternating between dset and the setpoint temperature. 11. Press the UP ARROW key button twice. CHANGE THE CASE MODEL. 12. The display should alternate between CASE and the set case model (for example, ucic, ucff or uccl). (Note: ucic is for a 10ºF ( 23ºC) setpoint, ucff is for a 2ºF ( 19ºC) setpoint, and uccl is for a +35 F (+1.6 C setpoint.) 13. Press the ENTER key once. TheuCiC or ucff should be flashing. 14. Press the UP ARROW or DOWN ARROW key to find the other case model to be selected. 15. Then press the ENTER key once. The display should read CASE, then ucic, ucff or uccl should be flashing. P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 9 16. Press the DOWN ARROW key 6 times. The display should read rst. 17. Press the SETUP key once. The unit should reboot. REASSIGN NETWORK ADDRESS. 18. If the network address written from Step 8 is none then proceed to Step 26 to skip reassigning network address and confirm the new case model. 19. While rebooting, the display should read SAFE for about 6 seconds then followed by -net for 6 seconds. Anytime during display reading SAFE or -net, press the DOWN ARROW key. CONFIRM THE NEW CASE MODEL. 26. Display reads SAFE, then -net, then 10.50, then the new selected case model (ucic, ucff or uccl followed by the temperature reading. 27. Press the SETUP key once. The unit reads StUP and then alternating between dset and then 10 for ucic, 2 for ucff or +35 for uccl. 28. The WALK IN UNIT default parameters have been reloaded. 29. In a few seconds the display will return to the temperature reading. 20. Display continues reading SAFE, then -net, then 10.50, then the new selected case model (ucic, ucff or uccl). 21. After displaying case model, the display reads Addr and then flashes none (Default no communication network address) 22. Press the UP ARROW or DOWN ARROW key to navigate to the address which was written down in step8. 23. Press the ENTER key once and then the display should alternate between Addr and the new assigned network address. 24. Press DOWN ARROW key once when display is alternating between Addr and the new assigned network address. The display should read rst. 25. Press the SETUP key. The unit should reboot. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. KRSCP

10 KRSCP P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

P/N 1H52918001_B 11 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. KRSCP

12 KRSCP Notes: P/N 1H52918001_B U.S. & CANADA 1-800-922-1919 MEXICO 1-800-522-1900 WWW.HUSSMANN.COM

To obtain warranty information or other support, contact your Hussmann representative. Please include the model and serial number of the product. Hussmann Corporation, Corporate Headquarters: Bridgeton, Missouri, U.S.A. 63044-2483 01 July 2005

Hussmann Corporation 12999 St. Charles Rock Road Bridgeton, MO 63044-2483 www.hussmann.com