Peer Industries Concealed Ceiling systems

Similar documents
Ceiling Systems are not Trafficable unless stated, and are designed to carry the weight of the ceiling only.

Concealed Ceiling Systems

CONCEALED CEILING SYSTEMS INSTALLATION GUIDE

Furring Channel Resilient Mount - Direct Fixing. Ceiling Systems. intex.com.au / intex.co.nz. Intex

Ceiling Systems 6 Intex Price Guide

key-lock installation guide key-lock Concealed Suspended Ceiling Systems

GENIE CLIP TYPE RST. Resilient Sound Isolation Clip INSTALLATION INSTRUCTIONS

SCREWFIX SUSPENSION SYSTEM

INTERNAL FRAMING PROFILES

WARM WATER UNDERFLOOR HEATING SYSTEMS. Guidance Notes

Report Number BTC 15450A

SOUND ISOLATION SOLUTIONS

SonusClip Installation for walls or ceilings on wood or steel framing. Installation Instructions for Wall & Ceilings

SECTION GYPSUM PLASTER

Perimeos. Ceiling Recess. decor. systems

SPECIAL SPECIFICATION 2242 LATH, STUCCO AND PLASTER

UPONOR Ltd. Specification for UPONOR Q&E PEX Shrinkfit Plumbing Systems

Knauf Direct Bonding and Metal Furring

C08. S05. P02 P05 Decorative effects

Designpanel ACOUSTIC PERFORATED PLASTERBOARD WITH AIR PURIFYING FOR CEILINGS AND WALLS

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

TECTUM Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1" Thick Direct-Attach Wall and Ceiling Panels

CEILINGS BACKSPLASHES WALLS PROJECTS INSTALLATION GUIDE.

TECHNICAL. Design Guide. Retaining walls made easy with this beautiful solution EARTH RETAINING WALLS

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

AUGUST 2016 TECHNICAL BROCHURE GTEK TM CORNICE CORNICE SOLUTIONS. gtekplasterboard.com.au

Ultraflex Ceiling Grid (UFR)

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

MILLI CUBE HEATED TOWEL RAIL 825 X 600

COMMERCIAL & INDUSTRIAL Evaporative Air Conditioning Systems

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Regupol SonusClip Installation Guide for Walls or Ceilings with Wood or Steel Framing

Technical Concept. Ultraflex Ceiling Grid (UFR) All Types Cleanroom Ceiling Systems

Tectum Direct-Attach Ceiling and Wall Panels Assembly and Installation Instructions for 1-Inch Thick Direct-Attach Wall and Ceiling Panels

USER MANUAL & INSTALLATION GUIDE FR3 CEILING FAN. available in: 43 /1092mm 50 /1270mm 60 /1524mm ATTENTION ELECTRICIANS WARNING:

Timber in construction Eurocode 5 Span tables and guidelines

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Made to Measure Window Furnishings

E. Luminaire: Complete lighting fixture, including ballast housing if provided.

Acoustical tee. Acoustical Tee

HYDROTHERM FLOOR TO CEILING - SERIES

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

ATTIC UPRIGHT SPECIFIC APPLICATION SPRINKLER VK696 TECHNICAL DATA

Method Statement. General Site preparation by others: Preparation for screed system by others: Preparation for plate system by others:

Carbon Film Installation Instructions

Installation Instructions

Compare us against the competition

Powers TM Controls Accessories for Installing TH 192, TH 194 or Free Energy Band TH 193 HC Room Thermostats

Section Plaster Accessories

Hand-drawn curtain rails. wide channel

BLUE TONGUE ALUMINIUM GRID AND PERIMETER/PELMET SYSTEMS

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

10ft Wide Polytunnel Assembly Instructions

DESIGN OF FOOTBRIDGES

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

FIRE-RESISTANCE TEST ON FIRE COLLARS PROTECTING A PLASTERBOARD WALL PENETRATED BY SERVICES

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems

Easy Duct Tastic. User Guide. Model: Triumph Easy Duct Smart Switch Model: Sensation Easy Duct Smart Switch

CEILING SYSTEMS. Between us, ideas become reality. Armstrong Blue Tongue Aluminium Grid and Perimeter/Pelmet Systems

HYDROTHERM FLOOR TO CEILING - SERIES

Fire Collars for Floor Wastes Understanding BCA Compliance Options

Low Gradient Velocity Control Short Term Steep Gradient [1] Channel Lining Medium-Long Term Outlet Control Soil Treatment Permanent

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

SECTION (15820) - AIR DUCT ACCESSORIES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Richmond Hill Primary Renovation SECTION STAGE CURTAINS

SECTION INTERIOR LIGHTING

10.85 VicFlex Sprinkler Fittings

Assembly, Installation & Watering Guide VERTICAL GARDEN SYSTEM. Version 4. Product Version. Gro-Wall 4.0.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Static cooling ceiling system SKS-4/3 DS 4094 E /1. Technical Selection

TRUST THE ORIGINAL. SUBMITTAL PACKAGE

STACKABLE PARTITION DOOR SYSTEM FDP40V Installation Manual(Column Stacking)

Institute of Industrial Science, University of Tokyo Bulletin of ERS, No. 45 (2012) FAILURE OF CEILINGS IN AN AIRPORT BUILDING DURING THE 2011 OFF THE

Timber Venetians Manual

RAYCON ENGINEERS PTY LTD. Attic Mounted Whole House Fans. Owner s Manual

Smoke extraction duct of sheet steel

SECTION WET AUTOMATIC FIRE SPRINKLER SYSTEMS

I-VICFLEX.AB4. Victaulic VicFlex Style AB4 Sprinkler Fitting for Hat Furring Channel Ceiling Systems WARNING INSTALLATION INSTRUCTIONS

IMPERIAL. SERIES Ceiling Fan Instruction Book. Models: MIF123 MIF1233 MIF1234 MIF124 MIF1243 MIF1244

Zehnder ZIP Radiant Ceiling Panels

Please read this booklet, for the safe installation of your MULTI FUEL FIRE

INSTALLATION GUIDE ISODRIVE MOTOR. ST - 900m 3 /hr.

Australian/New Zealand Standard

1. RETAINING WALL SELECTION PROCEDURE

OP44-1 REV 2: Removed depiction of air intake hole in the CB-907A Right Aft Case Baffle.

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

Installation Manual PS-200 & PS-201

Floor Heating & Heated Towel Rails Product Catalogue

Model vkfd28b braided flexible sprinkler drops (lpcb approved)

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Owner s Manual Epix - Back Box

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

MEDIUM-DENSITY HOUSING # 7. Fire safety

Cooktop Chimney Ventilation Hoods

Transcription:

Peer Industries Concealed Ceiling systems Technical Manual Index General information/ Warranty and design considerations Engineering design certification Technical services Certification, standards and testing Peer Concealed Ceiling Steel Products Concealed ceiling systems product breakdown Concealed ceiling systems installation using TCR and Furring Channel Multidirectional clip C79S Direct fixing of furring channel/tcr system Direct fixing of Furring Channel Drop ceiling/ceiling bulkhead Fire Rated ceilings Acoustic STC rated ceilings Typical concealed ceiling joists Curved and raked ceilings Plasterboard installation Expansions and control joints Design notes Span table CCS01 Ceiling Joists Span table CCS02 Top Hat 50 Span table CCS03 Top Hat 75 Span table CCS04 Top Hat 60 Span table CCS05 16 Ceiling Batten Span table CCS06-10 TCR25 and TCR38 with FC18 and FC28 Span tables CCS11 Cyclonic ceiling Batten 22 Clip capacity table CCS12 Sectional properties table SP-01 FCDB 16 Ceiling Batten Sectional properties table SP-02 FCCB 22 Cyclonic Ceiling Batten Sectional properties table SP-03 FC 18 & 28 Furring Channel Sectional properties table SP-04 Top Cross Rail 25 and 38 Sectional properties table SP-05 Top Hat 50 & 75 Notes Page CCS01 CCS02 CCS03 CCS04-05 CCS06-11 CCS11-12 CCS12 CCS17 CCS18 CCS19 CCS20 CCS22 CCS23 CCS24 CCS25-27 CCS27-28 CCS29 CCS30 CCS31 CCS32 CCS33 CCS34 CCS35 CCS36-38 CCS39 CCS40 CCS42 CCS43 CCS44 CCS45 CCS46 CCS47-48 Peer Industries PIF-MSC-011 Rev 05 16/10/07 Concealed ceiling systems technical manual

General Information This Technical manual contains details of Peer Industries cold roll formed and pressed steel products. Peer Industries provide this manual for use by Architects, Engineers, Designers, Contractors and Sub-Contractors to assist in product selection and use. It has been prepared using relevant Australian Standards together with sound engineering principles substantiated through laboratory tests. Peer Industries cold roll formed and pressed steel products are economical, efficient and durable structural members suitable for a wide range of building applications. Peer Industries steel products are manufactured in accordance with the requirements of relevant Australian and New Zealand Standards. Warranty and Design Considerations Peer Industries offers a warranty in keeping with Australian Standards and Project requirements of up to fifteen years. This Peer Technical manual is designed to provide a general guide to the design and application of Peer concealed ceiling systems. These systems comprise of top cross rails, furring channels, battens, and assorted suspension clips. Should you require information or design assistance related to systems outside those covered in this manual, you can contact Peer design on design@01peer.com or contact our nearest office by calling 1300 725 675 from anywhere in Australia. Peer Industries Pty Ltd will not be held responsible for any claims resulting from the use of Peer Industries products that have not been installed in accordance with the manufacturer s recoendations, design manuals, or relevant Australian Standards. All installations must be carried out in accordance with this and other relevant technical updates. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 1 of 47

Certification Engineering Design Certificate Umesh C Khatri RPEQ - 4829 is a registered professional engineer of Queensland and is an engineer with Peer Industries Pty Ltd being a manufacturer and supplier of the steel framing products. This is to certify that the span and height tables provided in this design manual for Peer Industries cold formed steel sections are in accordance with the requirements of the following Australian Standards: AS1538-1988/AS4600, Cold Formed Steel Structure Code. AS2785-1985/2000 Suspended Ceiling Design and Installation. AS1250/4100 Steel Structure and Building Code of Australia. Umesh C Khatri RPEQ 4829 Customer Support Design Engineer BE Civil, CP Eng, MIE (Aust), RBP (Vic), RPEQ, NPER-3, MFIE, MIEI On behalf of Peer Industries Pty Ltd Dated October 2007. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 2 of 47

Technical Services Peer Design Peer Industries provides a complete design service and our structural engineers will assist you with the design phase of your project. This design manual has been prepared with a view to providing Architects, Engineers, Designers, Contractors and Subcontractors with: A convenient design aid in the form of maximum heights or maximum span tables. Design data - Section properties to enable the design of required configurations not covered in this manual. Installation and construction details. The Height and Span Tables for Peer Industries steel products provides solutions for the following broad range of design conditions. Design loads which are uniformly distributed. Spans for single span, double spans and continuous spans as specified. Sizes of steel products with all dimensions. Steel products with nominated base metal thicknesses (BMT s). Load capacity tables with clip capacities Contact our experts at Peer Design by email design@01peer.com, call for our nearest office on 1300 725 675 or visit our website at www.peerindustries.com.au Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 3 of 47

Testing and Standards Australian and New Zealand Standards AS1397 2001 Steel Sheet and Strip Hot Dipped Zinc-coated or Aluminium/Zinc coated AS/NZS 4600-1996 & AS 1538 1988 SAA Cold Formed Steel Structures. AS/NZS 2588-1998 Gypsum Plasterboard. The Application and finishing of Gypsum Plasterboard in framed dwelling construction. AS1250 AS3566 AS/NZS2785-2000 & AS2785 1985 AS4055 1992 AS3623-1993 AS1170 0, 1, & 2 2002/1989 AS1170.4 1993 NZ4203 1992 AS1530.4 1990 AS1191 1985 SAA Steel Structure Code. Screws - self-drilling - for the building and Construction industry. Suspended Ceilings Design and Installation. Wind Loads for Housing. Domestic Metal Framing. Dead, Live and Wind Loads. Earthquake Loads. Seismic Code. Fire Resistance Tests of Elements of Building Construction. Test Methods for Laboratory measurement of Airborne Sound Transmission Loss of Building Partitions. Tests to comply with the Building Code of Australia C1.8 BRANZ Test Report STR 213: Tests Peer Industries Pty Ltd cold-formed steel studs are tested in conjunction with Plasterboard conforming to AS2588 for: (a) Resistance to Static Pressure Tests to ASTM E72-80 (b) Resistance to Impact Tests to ASTM E695-79 (c) Surface Indentation Tests to AS 2185 Appendix A2. Steel studs were tested as specified in (a), (b) and (c) above (see Test Report STR 213). The results were checked for compliance with the Building Code of Australia 1990 (BCA). Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 4 of 47

Testing and Standards cont d BRANZ Test Report FR1660, FR1661: Peer Industries Pty Ltd cold roll formed steel furring channels, top cross rails and battens are tested in conjunction with plasterboard complying with the Building Code of Australia (BCA) and AS1530.4 for: (a) Fire Resistance Level (FRL) of 90/60/60 FR1660 (b) Fire Resistance Level (FRL) of 120/90/120 FR1661 CSIRO Test Report STR 019: Peer Industries cold-formed steel furring channels, top cross rails and battens are tested in conjunction with plasterboard complying with AS2588 for airborne sound transmission loss. Note: Airborne-sound-transmission loss = sound transmission class Rw 32 as per AS 1276-1979 and the BCA Material: Peer Industries cold roll formed steel sections and pressed products are manufactured from zinc coated steel strip conforming to AS 1397 for thickness up to and including 1.55 BMT (base metal thickness). The steel strip for the various section sizes has a minimum yield stress of 300 Mpa. Coating: All Peer Industries cold roll formed steel sections are coated with zinc with a minimum coating mass of 220-275 grams/m 2 as indicated. Performance Peer cold roll formed steel sections and pressed products will perform as specified if used in accordance with the recoendations and details set down in this technical brochure and related design references together with good trade practices. Any variations from these recoendations and details will require special design and detailing. Information in this brochure is current at the time of printing. Specifications and recoendations are subject to change without notice. Whilst every care is taken at the time of the preparation of this brochure, Peer accepts no liability for any errors or ambiguities. Contact Peer office to discuss any such concerns. For applications outside the scope of this design manual, contact Peer design on design@01peer.com or contact our nearest office by calling 1300 725 675 from anywhere in Australia. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 5 of 47

Concealed Ceiling Steel Products The Peer Industries concealed ceiling system utilises furring channels, top cross rails, rod and suspension clips to provide a flush ceiling finish. This concealed ceiling system is versatile and provides many options to the user. These concealed ceiling systems have been designed to meet Australian and New Zealand Standards together with sound engineering principles substantiated through laboratory tests. Ceiling Systems are not Trafficable unless stated, and are designed to carry the weight of the ceiling only. The Peer concealed ceiling system can be used in both fire rated and non fire rated situations using appropriate plasterboard or other suitable cladding materials. Peer Industries concealed ceiling systems can be used to build either a typical ceiling or an acoustically rated ceiling by using appropriate plasterboard. Acoustic ceilings with a specific STC rating can be achieved by using furring channel with resilient mounts and appropriate plasterboard. This suspended ceiling systems manual is designed to provide a general guide to the design and application of Peer Suspended Ceilings. For more information or design assistance related to systems outside those covered in this design manual, contact Peer Design by email on design@01peer.com or our nearest customer service centre by calling 1300 725 675 for further advice. Concealed Ceiling Steel Products T18-150 track 18 to 150 WSL51-150 Lipped Stud 51 to 150 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 6 of 47

Concealed Ceiling Steel Products TH50-75- Top hat 50 and 75 FC18-28- Furring channel 18 and 28 C38- Furring channel 18 and 28 joiner FCCB22 22 Ceiling batten FCDB 16 Ceiling batten CDB38 16 Ceiling batten joiner FCBBB Back blocking batten TCR25/38- Top cross rail in 25 and 38 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 7 of 47

Concealed Ceiling Steel Products cont d C21-5 suspension rod C54 5 suspension rod joiner C74- Suspension rod bracket Purlin C47-74 Suspension rod bracket multi purpose C60- Adjustable suspension clip for TCR C60DF- Adjustable suspension clip Purlin C60LDF- Adjustable suspension clip for slab C52 Spring adjustable C26-80 furring channel clip Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 8 of 47

Concealed Ceiling Steel Products cont d C24 Top cross rail direct fix clip to timber or steel C66 Top cross rail direct fix clip to timber or steel C26-80/180 Furring channel direct fix clip CDB26-80/150 16 Batten direct fix clip C37-7H Furring channel anchor clip 7.5 hole C37-M6- Furring channel anchor clip M6 CFCAM Furring channel adjustable mount CFCRESAM F/C resilient adjustable mount Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 9 of 47

Concealed Ceiling Products cont d C79S Furring channel to TCR swivel clip CFSAM Furring channel screw adjustable mount C001 Furring channel acoustic mount C001M6 Furring channel acoustic mount M6 C79SRES Furring channel to TCR acoustic mount. C001-DCS Concrete to stud wall mount acoustic CTCR100 600 Direct fix adjustable TCR CTCRES100 600 Direct fix adjustable TCR Acoustic Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 10 of 47

Concealed Ceiling Products cont d C39 Furring channel to top cross rails (Locking key) CDB39 16 batten to TCR clip CDB37 16 batten direct fix clip CBET.FIX Furring channel direct fix adjustable C61S TCR side mounts rod adjustable clip. Concealed ceiling systems product breakdown Suspension Systems C21 Suspension rod (available up to 6000 in length) C39 Furring channel to top cross rails (Locking key) C74 Suspension rod bracket C47-74 Suspension rod bracket multi purpose C60 Adjustable suspension clip for top cross rail C61S Side mount TCR clip CDB39 16 batten to TCR clip CTROE Threaded rod one end (available up to 6000 in length) CTRBE Threaded rod both ends (available up to 6000 in length) C79S Furring channel to TCR swivel clip (multidirectional) Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 11 of 47

Concealed Ceiling Product Breakdown cont d Direct Fix Clips for Furring Channels and 16 Battens C26-80 Furring channel direct fix clip 80 drop C26-180 Furring channel direct fix clip 180 drop C52 Spring adjustable C26-80 furring channel Clip CDB26-80 16 batten direct fix clip 80 drop CDB26-150 16 batten direct fix clip 150 drop CDB37 16 batten direct fix clip CFCAM Furring channel adjustable mount CBET.FIX Adjustable furring channel direct fix clip Anchor Clips Furring Channel C37-7H Furring channel anchor clip 7.5 hole C37-M6 Furring channel anchor clip M6 Direct Fix Clips for Top Cross Rails C24 Top cross rail direct fix clip to timber or steel C66 Top cross rail direct fix clip to timber or steel CTCR Direct fix adjustable TCR Misc Components C54 Adjustable suspension rod joiner C38 Furring channel joiner CDB38 16 batten joiner CTP60 Suspension rod slab tap in anchor 60 CFCSAM Furring channel screw adjustable mount (smart clip) Accessories for Acoustic (STC) Ceiling C001 Furring channel resilient acoustic mount C79SRES Furring channel to TCR resilient mount. C001-DCS Concrete to stud wall mount acoustic. CFCRESAM Furring channel resilient adjustable mount CTCRRES Direct fix adjustable TCR acoustic Top Hats TH75-115 Top Hat 20x35x75x35x20 TH50-115 Top Hat 20x35x50x35x20 Ceiling Battens FCDB 16 domestic batten FCCB22-61 Furring channel ceiling batten 22 Cyclonic Furring Channel and Furring channel Track FC18 & FC28 Furring channel 18 and 28 T18 & T28 Furring channel Track 18 and 28 Ceiling Joists Studs Wall Studs Lipped - Marked as WSL Stud sizes 51 (WSL51), 64 (WSL64), 76 (WSL76), 92 (WSL92), 150 (WSL150) Stud material base metal thickness (BMT) 0.50, 0.55, 0.75, 1.15 and 1.55 Ceiling Joists End Support Tracks - Marked as T Track sizes 51 (T51), 64 (T64), 76 (T76), 92 (T92), and 150 (T150). Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 12 of 47

Installation (1) Typical Suspended Concealed Ceiling Systems using TCR & FC Refer to figs 01 to 27 Locate position of trusses or purlins or concrete etc and based on the ceiling plan, mark the position of the suspension rod brackets (Peer product code C74 or C47-74) on it at 1200 centres maximum along supporting members. Fix the C74 or C47-74 suspension rod brackets as appropriate to the side of the steel purlins or bottom chord of the trusses with two self tapping screws in shear and to concrete with appropriate anchors. Cut all hanging rods (Peer product code C21) to the required length. Assemble adjustable suspension clip for TCR (Peer product code C60) on all these suspension rods. Install all of these rods (Peer product code C21) into the suspension rod brackets C47-74. Attach Top Cross Rails (Peer product code TCR25 or TCR38) to the suspension clips (Peer product code C60). Connect Furring Channels (Peer product code FC18 or FC28) to top cross rails TCR25 or TCR38 with locking keys (Peer product code C39). Check and adjust the ceiling system using a laser or other appropriate levelling device. Install ceiling lining boards as per manufacturers specification Plasterboard Hanger maximum distance from wall 300 Peer concealed ceiling framing Fig 01 example of TCR/FC suspended ceiling Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 13 of 47

Installation cont d Peer top cross rail Fix Hangers a maximum of 300 from the wall Peer furring channel C21 Peer suspension rod C60 Peer suspension clip 1200 max Hanger maximum distance from wall 300 1200 max 600 max Fig 02 example of suspension rod, anchors, FC and TCR 35 plasterers angle or Peer T18 / T28 with bottom flange aligned with bottoms of furring channel and fixed to wall at ends and 600 centres max. Timber, steel or concrete support structure End of top cross rail 10 clear of wall for fire rating 1200 max Hanger maximum distance from wall 300 Furring channel spacing 600 centres max Top cross rail or Suspension rod spacing 1200 centres max Fig 03- suspended ceiling using C47-74/5 rod/c60 combination Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 14 of 47

Installation cont d (1)Suspended Ceiling fixing of Furring Channels and TCR Peer C21 suspension rod Peer C60 suspension clip Peer C39 Clip Peer top cross rail Peer furring channel Fig 04 Close up view FC18/28, C39, TCR25/38, C60 and Rod Combination Adjustable TCR clip CTCR (7 adjustment each notch) Peer top cross rail Peer furring channel Peer C39 clip Fig 05 Close up view of FC18/28, C39 and CTCR combination Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 15 of 47

Installation cont d Supporting member Appropriate Anchor Concrete slab Peer C47-74 Note: 2 screw fixings in shear Note: 2 screw fixings in shear Peer C21-suspension rod Fig 06 example of C47-74/Rod suspension system Concrete Steel Framing Timber Framing Appropriate anchor Peer C47-74 clip Peer C21 suspension rod Peer C47-74 fastened to timber framing/steel purlin with 2 screws in shear Peer C39 clip Peer C60 suspension clip Peer C60 suspension clip Peer top cross rail TCR Peer furring channel Fig 07 side view Rod/C60 suspension system with TCR25/38, C39/FC18 or 28 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 16 of 47

Installation cont d Peer Industries C79S multidirectional clip was designed specifically to make building a non standard (square or rectangular) ceiling easy The C79S clip is a multidirectional clip that will allow 360 degree rotation of furring channel to top cross rail. Fig 08 End view C79S multidirectional clip This clip has been specifically designed to address the problems encountered in the construction of irregularly shaped non square or rectangular ceilings. The use of this clip will simplify the construction of difficult ceilings and result in significant saving in construction time The C79S clip has been extensively load tested and complies with all relevant standards. Fig 09 C79S multidirectional (Swivel) clip with TCR/FC The C79S is manufactured from the highest quality corrosion resistant zinc plated steel available and is covered by Peer industries standard product warranty. Peer furring channel Peer top cross rail Fig 10 C79S multidirectional (Swivel) clip with TCR/FC Peer 79S Multidirectional Fig 11 C79S multidirectional (Swivel) clip with TCR/FC Fig 12 Irregular shape room layout using the C79S clip Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 17 of 47

Installation cont d Steel or timber framing Note: 2 screw fixings in shear Peer C66 clip Peer top cross rail Peer C39 clip Peer furring channel Fig 13 Direct Fixing using C66 to Top Cross Rail 25/38 then C39 to Furring Channel 18 or 28 (2)Direct Fixing of Furring Channels Refer to figs 14, 15 and 16 Locate the position of floor joists or purlins or concrete etc and based on the ceiling plan; mark the position of the direct fix clips (Peer product code C26-80 or C26-180) on it. Fix the direct-fix clips C26-80 or C26-180 to the steel purlins or timber joists with two screws in shear and to concrete with appropriate anchors. Connect the furring channels FC18 or FC28 to the direct-fix clip C26. Check and adjust concealed ceiling system using a laser or other appropriate levelling device. Install ceiling board as per manufacturers specification Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 18 of 47

Installation cont d Steel or timber framing Note: 2 screw fixings in shear Peer C26-80 or C26-180 clip Peer furring channel Fig 14 Direct fixing using C26-80 to furring channel 18 or 28 Timber or steel supporting member Peer furring channel Peer C26-80 or C26-180 clip Fig 15 Direct fixing using C26-80 to furring channel 18 or 28 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 19 of 47

Installation cont d Steel framing member Timber framing member Peer C26-80 or C26-180 fastened to timber with 2 screws Peer C26-80 or C26-180 fastened to steel framing with 2/10x16 TEX screws (or equivalent) Peer furring channel Plasterboard Fig 16 - Direct fixing system typical section. (3) Drop Ceiling Drop ceilings are required to allow for ducting, mechanical and electrical services, or as a feature with maximum of 600 drop Locate the position of the drop ceiling and mark the position of suspension rod Brackets (Peer product code C74 or C47-74) as per detail on trusses, purlins or concrete based on the ceiling plan. Join top cross rails TCR25 or TCR38 to suit site situation as per detail. Alternatively join furring channel FC18 or FC28 to suit site situation as per detail in Fig 17. Install suspension rod brackets C74 or C47-74, suspension rods C21, top cross rails TCR25 or TCR38 and furring channels FC18 or FC28 as per typical suspended concealed ceiling system. Check and adjust drop ceiling and concealed ceiling system using a laser or other suitable levelling device. Install ceiling lining board as per manufacturers specification Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 20 of 47

Installation cont d Roofing or floor Note: 2 screw fixings in shear Peer C47-74 clip Note: 2 screw fixings in shear Peer C60 clip Galvanised angle, C88 clip or screws Peer top cross rail 2 Screws 2 Screws Peer C39 clip C39 clip Galvanised angle, C88 clip or screws Galvanised angle, C88 clip or crews P90INT angle if required Peer furring channel 18 or 28 Peer C21 Suspension rod P90INT angle if required Peer C60 clip 2 Screws 600 maximum 600 maximum 2 Screws P90EX angle if required P90EX angle if required Parallel to Furring Channel Parallel to Top Cross Rail Fig 17 - Drop Ceiling details Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 21 of 47

Installation cont d (4) Fire Rated Ceiling Install concealed ceiling system as above with fire rating requirement. For fire rating ceiling, use the ceiling board manufacturer s specification and recoendations on installation. Provide a 20 gap at the ends of both top cross rails TCR25 or TCR38 and furring channels FC18 or FC28 for fire rating requirements as per board manufacturer s specifications and recoendations on installation. Timber, steel or concrete support structure End of top cross rail 20 clear of wall for fire rating Top cross rail span or suspension rod spacing 1200 max 35 plasterers angle or Peer T18 / T28 with bottom flange aligned with bottoms of furring channel and fixed to wall at ends and 600 centres max. Furring channel spacing 600 centres max Top cross rail spacing 1200 centres max 300 from wall Fig 18 - Typical concealed ceiling framing drawing Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 22 of 47

Installation cont d (5) Acoustic (STC) Ceiling C001, C001-SUS, CFCRESAM,CTCRRES and FC Resilient Mounts C001 CFCRESAM C79SRES CTCRRES Supporting members, timber or steel to be spaced at a maximum of 1200 centres. Locate the resilient mounts product no. C001 at maximum 600 centres along supporting members. Fasten using appropriate fasteners dependant on the weight of the plasterboard being used. Locate the furring channel product no. FC18 or FC28 in the resilient mounts C001 Locate short lengths of furring channel FC18 or FC28 to support butt joins in second layer of ceiling lining or as per board supplier s specification. Timber or steel supporting member Peer C001 resilient mount clip Butt joint support 1200 max centres 600 max centres Furring channel Fig 19 Acoustic Ceiling using C001 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 23 of 47

Installation cont d (6) Typical Concealed Ceiling System - Ceiling Joists Refer to Fig 20 Electrical, mechanical and plumbing services can make suspended ceiling systems difficult to install. The height of a project can also render the installation of a suspended ceiling system uneconomical. To solve this problem Peer steel studs can be used as ceiling framing members in areas such as corridors and bathrooms. Refer to span table CS-01 for ceiling joist sizes and spacing. Mark position of tracks at ceiling level on wall as per working drawings. Fix these perimeter tracks with appropriate fasteners close to stud (ceiling joist location) at 600 maximum centres. Cut the studs to required length. Fit the studs in to the tracks. Provide and fix bridging members at the location as per table CS-01 Install ceiling lining board as per manufacturer s specification. Peer track Peer bridging stud or track Screws Peer track Fixing of track to wall Peer wall stud Fig 20 - Typical concealed ceiling system Ceiling Joists Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 24 of 47

Installation cont d (7) Curved and Raked Ceiling Curved or raked ceilings are to be provided wherever required by an architect or project designer for decorative purpose to suit site/project specification. Roofing or flooring Purlin or Rafter Peer C47-74 clip Bracing 2 Screws in shear Peer C21 suspension rod NOTE: Refer to plasterboard specification for spacing of furring channel to suit radius Radius Peer C60 clip Peer top cross rail Peer furring channel Caulk all perimeter joins with cornice adhesive Appropriate Screw Screw through TCR and C39 clip Plasterboard Peer C39 clip Fig 21- Typical Section Curved Ceiling (non fire rated) Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 25 of 47

Installation cont d Framing member Peer C47-74 clip Peer C21 suspension rod Note: 2 screw fixings in shear Peer C60 clip Peer top cross rail Angle cleat Screw through TCR and C39 clip Peer C39 clip Continuous angle 0.75 BMT galv MS 50 min leg length Peer furring channel Appropriate Screw 600 max Plasterboard Appropriate Screw 200 max Tape and set joint Fig 22 - Normal ceiling Joint type A Framing member Angle cleat Peer C47-74 clip Appropriate Screws in shear Peer C21 suspension rod Continuous angle 0.75 BMT galv MS 50 min leg length Peer C60 clip Screw through TCR and C39 clip Peer top cross rail Peer C39 clip Peer furring channel 200 max Plasterboard Fig 23 - Normal ceiling Joint type B Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 26 of 47

Installation cont d Curved Ceiling Install curved TCR25 top cross rail as per ceiling framing plan and in accordance with the above ceiling installation details and appropriate bracing with brace. Install FC28 furring channels at a spacing to suit the radius of the curved ceiling with Peer furring channel to top cross rail C39 (locking key) clips Secure the C39 to the TCR with a screw fastener to prevent slipping. Refer to plasterboard specification of curved ceiling for spacing of furring channels. Raked Ceiling Install TCR38 top cross rail in raking position as per ceiling framing plan and in accordance with the above ceiling installation details and appropriate bracing. Install FC28 furring channels at spacing to suit ceiling lining thickness with Peer furring channel to top cross rail C39 (locking key) securing the C39 to the TCR with a screw fastener. Refer to plasterboard specification for spacing of furring channels. Lining to Ceiling Frame Plasterboard Installation Cut the plasterboard sheets to size. Position the sheet with the recessed edge at right angles to the framing member. Press sheet firmly against the adhesive (if it is to be used - see manufacturer s specifications) and fasten at the centre line of the sheet on every framing member as shown in fig 07. Use full sheets. Saw cut sheets around openings. Butt joints must be staggered and not in a straight line across the ceiling. All plasterboard installation should be in accordance with AS 2588 & AS 2589 and the manufacturers specifications. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 27 of 47

Installation cont d Plasterboard Peer concealed ceiling framing Fig 24 Plaster board installation Other Building Board Installation: All building board installation should be in accordance with the manufacturer s specification and recoended installation methods. Expansion and Control Joints: Expansion joints as well as control joints must coincide with those structural control joints provided in the main structure. Control joints shall be provided in long continuous ceiling at 12 metres maximum spacing. Refer to Figs 25, 26 and 27 for control joint at perimeter, parallel to furring channel and perpendicular to furring channel. Storage and Site Handling: Where possible all material used in the construction of steel ceiling framing should be handled in a manner that reduces the risk of damage. All material should be kept in a dry area so accidental damage cannot occur. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 28 of 47

Installation cont d Examples of various ceiling system control joints 6 Gap Plasterboard Wall angle trim Fig 25 - Ceiling to Wall Control Joint At Wall End Plasterboard Peer furring channel 50 max Peer PXJ30 plasterboard expansion joint (runs parallel to the Furring Channel) Fig 26 - Ceiling Control Joint Parallel to Furring Plasterboard Peer furring channel 15 max Peer PXJ30 plasterboard expansion joint (perpendicular to the Furring Channel) Fig 27 - Ceiling Control Joint Perpendicular to Furring Channel Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 29 of 47

Design Notes Span tables are prepared for the use of top cross rails, furring channels, top hats and ceiling battens that are manufactured by Peer Industries Pty Ltd. Tables are based on permissible stress loading calculated as per AS1538-1988 Cold Formed Steel Structures Code AS2785-1985 Suspended Ceilings Design and Installation Deflection = As specified under tables Yield stress = 300 Mpa Section properties are based on the full section, using the nominal section dimensions notations which are in accordance with AS 1538. Refer to the sectional properties tables for full details of all products All information contained in this brochure is intended as a general guide only for use in ceiling framing construction. For use in any other design and construction or for any special structure, please contact Peer Design by email design@01peer.com Call one of our customer service centres on 1300 725 675 or visit our web site www.peerindustries.com.au Almost all structures will deflect during service. Ceiling designers should be aware of the expected deflections of the building structures as they affect the ceiling. These deflections may be due to both dead and live loadings. In fire rated ceiling framing, thermal expansion of steel frames should be expected during fire service. Designer should make due allowances for these effects. The ceiling designer should properly consider framing design and layout around openings in ceiling systems. Ceiling spans are determined by various design criteria including: weight of ceiling, wind loading, deflection limits, material size and required spacing s. For span information to satisfy specific design criteria contact Peer Design. Some examples detailing various component scenarios have been provided to assist in the choice of the correct product for most building projects. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 30 of 47

Internal Pressure 0.25 kpa SPAN TABLE CCS01 CEILING JOIST - Single Span Wall Studs Lipped Stud Size Thickness Maximum Span in BMT 10Plaster board (0.09 kn/m 2 ) 13Plaster board (0.12 kn/m 2 ) S tud Spacing in 16Plaster board (0.15 kn/m 2 ) 600 450 300 600 450 300 600 450 300 0.50 2080 2280 2595 2025 2220 2525 1975 2165 2465 64 0.75 2430 2670 3035 2370 2600 2960 2310 2535 2885 1.15 2795 3060 3465 2720 2980 3380 2655 2910 3300 0.55 2385 2710 3080 2335 2635 3000 2290 2575 2925 76 0.75 2785 3055 3470 2710 2970 3380 2640 2895 3295 1.15 3165 3460 3825 3085 3370 3755 3010 3290 3690 0.55 2870 3145 3575 2790 3065 3485 2720 2985 3400 92 0.75 3215 3520 3890 3130 3430 3815 3050 3345 3745 1.15 3655 3900 4270 3575 3830 4190 3515 3760 4120 150 0.75 4395 4695 5135 4310 4605 5045 4230 4525 4955 1.15 4860 5180 5645 4765 5085 5550 4685 5000 5460 Based on: Deflection = S/360. Spans are as per AS1538 & AS2785. Bridging: 0-2500 span = No Bridging. 2500-4000 span = One row of Bridging. 4000-6000 span = Two rows of Bridging. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 31 of 47

SPAN TABLE CCS02 Span Table - TH50-115 Top Hat Ceiling Installation Top Hat Section TH50-115 = 20x35x50x35x20 x1.15 Lateral Pressure Permissible Ultimate kpa Limit State MAXIMUM TOP HAT SPAN Single Span Double Spans Continuous Spans Top Hat Spacing in 600 450 600 450 600 450 0.75 1.12 1485 1635 1990 2190 1835 2020 1.00 1.50 1350 1485 1810 1990 1665 1835 1.50 2.25 1175 1295 1580 1740 1455 1600 2.00 3.00 1070 1175 1385 1580 1325 1455 2.50 3.75 995 1095 1240 1430 1230 1350 3.00 4.50 935 1030 1130 1305 1155 1270 4.00 6.00 850 935 980 1130 1050 1155 5.00 7.50 790 870 875 1010 975 1075 6.00 9.00 740 815 800 920 890 1010 Based on: Deflection = span/360. Critical of Strength & deflection As per AS1538 and AS4600 - Cold Formed Steel Structures Code. Permissible stress design and ultimate loads. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 32 of 47

SPAN TABLE CCS03 Span Table TH75-115 Top Hat Ceiling Installation Top Hat Section TH75-115 = 20x35x75x35x20 x1.15 Lateral Pressure Permissible Ultimate kpa Limit State MAXIMUM TOP HAT SPAN Single Span Double Spans Continuous Spans Top Hat Spacing in 600 450 600 450 600 450 0.75 1.12 1570 1725 2095 2305 1935 2135 1.00 1.50 1425 1570 1905 2095 1760 1935 1.50 2.25 1245 1365 1660 1830 1540 1690 2.00 3.00 1130 1245 1470 1660 1395 1540 2.50 3.75 1050 1155 1310 1510 1300 1430 3.00 4.50 990 1085 1190 1380 1220 1345 4.00 6.00 900 990 1035 1190 1080 1220 5.00 7.50 835 920 920 1065 970 1100 6.00 9.00 785 865 840 975 850 1000 Based on: Deflection = span/360. Critical of Strength & deflection. As per AS1538 and AS4600 - Cold Formed Steel Structures Code. Permissible stress design and ultimate loads. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 33 of 47

SPAN TABLE CCS04 Span Table TH60-075 Top Hat MAXIMUM TOP HAT SPAN - SINGLE SPAN INSTALLATION Location on Wall General Zone Edge Zone Wind Classification 300MM Spacing 450MM Spacing 600 Spacing 300MM Spacing 450MM Spacing 600 Spacing N1 2300 2000 1850 2050 1750 1600 N2 2300 2000 1800 1950 1700 1500 N3 2000 1650 1450 1650 1400 1200 N4 1650 1350 1200 1400 1150 1000 N5 1400 1100 950 1150 950 800 C1 1750 1500 1250 1500 1200 1050 C2 1450 1150 1000 1200 100 850 C3 1200 950 850 1000 800 700 C4 1000 850 750 850 700 600 MAXIMUM TOP HAT SPAN - DOUBLE SPAN INSTALLATION Location on Wall General Zone Edge Zone Wind Classification 300MM Spacing 450MM Spacing 600 Spacing 300MM Spacing 450MM Spacing 600 Spacing N1 2800 2350 2100 2400 2000 1750 N2 2450 2050 1850 2100 1700 1450 N3 2050 1700 1500 1650 1350 1150 N4 1700 1400 1200 1350 1100 950 N5 1400 1150 1000 1100 900 800 C1 1750 1450 1250 1450 1150 1000 C2 1450 1150 1000 1200 950 850 C3 1200 950 850 950 800 700 C4 1000 850 700 850 700 600 MAXIMUM TOP HAT SPAN - SINGLE SPAN INSTALLATION Location on Wall General Zone Edge Zone Wind Zone 300MM 450MM 600 300MM 450MM 600 Spacing Spacing Spacing Spacing Spacing Spacing LOW 2700 2350 2150 2350 2000 1800 MEDIUM 2450 2150 1950 2100 1800 1600 HIGH 2200 1900 1650 1800 1600 1400 VERY HIGH 2000 1650 1450 1650 1400 1200 MAXIMUM TOP HAT SPAN - DOUBLE SPAN INSTALLATION Location on Wall General Zone Edge Zone Wind Zone 300MM 450MM 600 300MM 450MM 600 Spacing Spacing Spacing Spacing Spacing Spacing LOW 2950 2450 2200 2600 2100 1850 MEDIUM 2550 2200 1950 2250 1850 1600 HIGH 2250 1950 1700 1900 1550 1350 VERY HIGH 2050 1700 1500 1650 1350 1150 Notes 1. Material is 0.75 BMT and G300 2. Double span installation assumes that the 2 spans are approximately equal 3. If spans differ by more than 25% the use the single span table Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 34 of 47

Ceiling Installation SPAN TABLE CCS05 Span Table FCDB 16 Batten Plasterboard MAXIMUM SPAN in Continuous Span 600 450 10 Plasterboard (7 kg/m 2 ) 1050 1150 13 Plasterboard (10 kg/m 2 ) 1000 1100 Based on: AS 3623, Serviceability = Span/600 for G only. AS 1170.2 2002, Serviceability = Span/200 for G + Ws. AS 3623, Ultimate Strength for 1.25G. AS1170.2-2002, Ultimate Strength for 1.2G + Wu. Wind Loads as per AS 4055. G550 and t = 0.38. As per AS 4600 - Cold Formed Steel Structures Code. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 35 of 47

TCR SPAN TABLE CCS06 Top Cross Rail TCR25 - Wind Category N2 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 86 86 70 86 36 36 36 36 900 54 71 41 71 28 28 28 28 1000 40 62 30 62 23 23 23 23 1200 23 47 17 45 14 14 14 14 Top Cross Rail TCR38 - Wind Category N2 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 94 173 70 148 94 100 70 100 900 54 143 41 107 54 79 41 79 1000 40 104 30 78 40 68 30 68 1200 23 60 17 45 23 52 17 45 Tables provide the maximum allowable ceiling weight in kg/sqm, supported by Peer framing. Ultimate wind pressure on ceiling = 0.29 kpa. Serviceability wind pressure on ceiling = 0.12 kpa. Figures in italics indicate strength is critical elsewhere, deflection is critical. Shaded means that FC is critical TCR SPAN TABLE CCS07 Top Cross Rail TCR25 - Wind Category N3 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 77 77 70 77 25 25 25 25 900 54 58 41 58 14 14 14 14 1000 40 48 30 48 9 9 9 9 1200 23 33 0 33 0 0 0 0 Top Cross Rail TCR38 - Wind Category N3 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 94 165 70 136 86 86 70 86 900 54 131 41 107 54 65 41 65 1000 40 104 30 78 40 54 30 54 1200 23 60 0 45 23 38 0 38 Tables provide the maximum allowable ceiling weight in kg/sqm, supported by Peer framing. Ultimate wind pressure on ceiling = 0.45 kpa. Serviceability wind pressure on ceiling = 0.18 kpa. Figures in italics indicate strength is critical elsewhere, deflection is critical. Shaded means that FC is critical Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 36 of 47

TCR SPAN TABLE CCS08 Top Cross Rail TCR25 - Wind Category N4 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 59 59 59 59 7 7 7 7 900 39 39 39 39 0 0 0 0 1000 29 29 26 29 0 0 0 0 1200 0 14 0 14 0 0 0 0 Top Cross Rail TCR38 - Wind Category N4 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 94 147 70 118 67 67 67 67 900 54 112 41 88 46 46 41 46 1000 40 95 26 67 36 36 26 36 1200 0 58 0 28 0 20 0 20 Tables provide the maximum allowable ceiling weight in kg/sqm, supported by Peer framing. Ultimate wind pressure on ceiling = 0.67 kpa. Serviceability wind pressure on ceiling = 0.27 kpa. Figures in italics indicate strength is critical elsewhere, deflection is critical. Shaded means that FC is critical TCR SPAN TABLE CCS09 Top Cross Rail TCR25 - Wind Category C1 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 33 33 33 33 0 0 0 0 900 13 13 13 13 0 0 0 0 1000 0 3 0 3 0 0 0 0 1200 0 0 0 0 0 0 0 0 Top Cross Rail TCR38 - Wind Category C1 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 94 121 66 92 41 41 41 41 900 54 86 20 62 20 20 20 20 1000 0 69 0 42 0 10 0 10 1200 0 32 0 3 0 0 0 0 Tables provide the maximum allowable ceiling weight in kg/sqm, supported by Peer framing. Ultimate wind pressure on ceiling = 0.98 kpa. Serviceability wind pressure on ceiling = 0.40 kpa. Figures in italics indicate strength is critical elsewhere, deflection is critical. Shaded means that FC is critical Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 37 of 47

TCR SPAN TABLE CCS10 Top Cross Rail TCR25 - Wind Category C2 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 0 0 0 0 0 0 0 0 900 0 0 0 0 0 0 0 0 1000 0 0 0 0 0 0 0 0 1200 0 0 0 0 0 0 0 0 Top Cross Rail TCR38 - Wind Category C2 Top Span of Top Cross Rail = 900 Span of Top Cross Rail = 1200 Cross Furring channel spacing Furring channel spacing Rail 450 600 450 600 spacing FC18 FC28 FC18 FC28 FC18 FC28 FC18 FC28 in Allowable ceiling weight in kg/sqm 750 76 80 26 51 1 1 0 0 900 0 46 0 22 0 0 0 0 1000 0 29 0 2 0 0 0 0 1200 0 0 0 0 0 0 0 0 Tables provide the maximum allowable ceiling weight in kg/sqm, supported by Peer framing. Ultimate wind pressure on ceiling = 1.45 kpa. Serviceability wind pressure on ceiling = 0.59 kpa. Figures in italics indicate strength is critical elsewhere, deflection is critical. Shaded means that FC is critical Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 38 of 47

Wind Loading N2- W33N Continuous over Three spans SPAN TABLE CCS11 Furring Channel Cyclonic Batten FCCB (0.38 BMT G550) Tables allow for maximum ceiling board load on ceiling battens Continuous Span of Ceiling batten 900 1200 Spacing of ceiling Batten Spacing of ceiling Batten 600 450 600 450 Weight of Ceiling Board in Kg/sqm 29 40 8.5 12.5 Based on: Weight of board in kg/sqm Ultimate wind pressure Wu = 0.29 kpa Serviceability wind pressure Ws = 0.12 kpa Deflection criteria- G = S/600 & G + Ws = S/200 As per AS4600, AS 2785, AS1170 & AS3623 Wind Loading N3-W41N Continuous over Three spans Continuous Span of Ceiling batten 900 1200 Spacing of ceiling Batten Spacing of ceiling Batten 600 450 600 450 Weight of Ceiling Board in Kg/sqm 24 40 --- 12.5 Based on: Weight of board in kg/sqm Ultimate wind pressure Wu = 0.45 kpa Serviceability wind pressure Ws = 0.18 kpa Deflection criteria- G = S/600 & G + Ws = S/200 As per AS4600, AS 2785, AS1170 & AS3623 Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 39 of 47

CLIP CAPACITY TABLE CCS 12 Peer clip capacity based on testing by ETRS Report No. 4206-2014/1 21/12/2006. & 4206-2014/3 05/04/2007 and 4206-2014/4-08/06/2007 These capacities are maximum allowable as per AS2785 2000 and 1985 Limit state design capacity is for AS2785 2000 Suspended Ceilings Design and Installation Working load is for AS2785 1985 Suspended Ceilings Design & Installation. Part number Limit Sate design capacity In kn Working load Weight on boards on clip In Kgs C001 1.45 82 C001-DCS 3.13 177 C001-SUS 0.94 53 C26-80 0.85 48 C26-180 0.85 48 C37-7H 1.20 68 C37-M6 1.17 66 C39 0.94 53 C42 1.02 58 C47-74 1.75 99 C74 0.93 52 C52 0.90 51 C54 1.68 95 C60 1.64 92 C60DF 1.64 92 C60LDF 1.64 92 C61S Constrained 1.13 64 C61S Not Constrained 0.81 46 C79S 0.95 54 C85 0.53 30 C409 1.20 68 CDB26-80 0.57 32 CDB26-150 0.57 32 CBET.FIX First tooth 0.29 16 CBET.FIX Last tooth 0.67 37 CFCAM First tooth 0.57 32 CFCRESAM First tooth 0.52 29 CFCRESAM Last tooth 0.62 34 CFCSAM 1.59 89 CTCR-100 1.13 63 CTCRRES-100 Last tooth 1.32 74 C24 Suspended 1.31 74 C24 Hard bolted 1.34 75 C66 1.40 79 C001 1.25 70 NOTE: Limit state capacity less than 0.50 kn or Working load less than 25 kgs do not use that clip at that particular location. (Refer to Shaded area CBET-FIX do not use the first tooth of the clip to support furring channel) Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 40 of 47

SECTIONAL PROPERTIES TABLE No. SP-01 FCDB 16 Ceiling Batten Peer Part No Thickness Shear Centre Centroid Area Second Moment of Area Section Modulus Radius of Gyration t BMT Y S X C Y C A 2 I X-X x 10 3 4 I Y-Y x 10 3 4 Z X-X 3 Z Y-Y 3 R x R y FCDB16 0.38 8.26 17.485 5.52 28.64 1.154 5.63 107 326 6.35 14.02 Section properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specification: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m 2 zinc/alum. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 41 of 47

SECTIONAL PROPERTIES TABLE No. SP-02 FCCB 22 Ceiling Batten Peer Part No Depth Width Thickness Shear Centre Centroid Yield Strength Area Mono syetry Section Constant D B t BMT Y S X C Y C F Y MPa A 2 β x FCCB22 21.0 30 0.38 6.75 33. 0 10. 66 550 49.9 59.6 Peer Part No Torsion Constant Second Moment of Area Section Modulus Radius of Gyration Form Factor Warping Constant J 4 I X-X x 10 3 4 I Y-Y x 10 3 4 Z X-X 3 Z Y-Y 3 R x R y Q I w x 10 6 4 FCCB22 3.83 3.62 20.12 339 610 8.51 20.1 0.892 0.71 Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m 2 zinc/alum. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 42 of 47

SECTIONAL PROPERTIES TABLE SP-03 Furring Channel FC18 and FC28 Section Properties Peer Part No Dept h Width Thickness Shear Centre Centroid Yield Strength Area Second Moment of Area D B t BMT Y S X C Y C F Y MPa A 2 I X-X x 10 3 4 I Y-Y x 10 3 4 FC18 18 38 0.42 6.32 25.7 8.73 550 50.0 2.41 14.77 FC28 28 38 0.42 10.7 25.7 13.6 550 60.0 7.01 18.29 Peer Part No Torsion Constant Mono syetry Section Constants Section Modulus Radius Of Gyration Form Factor Warping Constant J 4 β X Z X-X 3 Z Y-Y 3 R x R y Q I W x 10 6 6 FC18 4.2 43 260 575 6.94 17.2 0.877 0.53 FC28 5.0 53 487 712 10.8 17.5 0.842 1.58 Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code. Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Zincalume G550 AZ150, Yield Strength - Fy = 550 Mpa & Coating Grade AZ150 g/m 2 zinc/alum. Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 43 of 47

SECTIONAL PROPERTIES TABLE SP-04 Top Cross Rail TCR25 and TCR38 Section Properties Peer Part No Depth Width Thickness Shear Centre Centroid Yield Strength Area D B t BMT Y S X C Y C F Y MPa A 2 TCR25 25.4 22.83 0.75 14.4 11.415 11.9 300 67.5 TCR38 38.3 22.83 0.75 21.8 11.415 18.35 300 87 Peer Part No Torsion Constant Second Moment of Area Section Modulus Radius of Gyration Form Factor J 4 I X-X x 10 3 4 I Y-Y x 10 3 4 Z X-X 3 Z Y-Y 3 R x R y Q TCR25 12.7 5.37 3.91 397 343 8.92 7.61 1.0 TCR38 16.3 15.55 4.70 779 411 13.37 7.35 1.0 Section Properties calculated in accordance with AS 1538 and AS 4600 - Cold Formed Steel Structures Code Material Specifications: Peer sections are roll formed from zinc coated steel strip which conforms to AS 1397. Material: G2 Z275, Yield Strength - Fy = 300 Mpa and coating grade Z275 (275 g / m 2 zinc). Peer Industries PIF-MSC-011 Rev 06 28/07/09 Concealed ceiling systems technical manual Page CCS 44 of 47