A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY

Similar documents
Heat Transfer in Evacuated Tubular Solar Collectors

American International Journal of Research in Science, Technology, Engineering & Mathematics

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Performance of an Improved Household Refrigerator/Freezer

Remote Helium Cooling Loops for Laboratory Applications

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

A new test procedure to measure the soil-water characteristic curves using a small-scale centrifuge

Experimental Study on Waste Heat Recovery from the Pyrolysis Stack using Heat Pipe

Performance test of a helium refrigerator for the cryogenic hydrogen system in J-PARC

Numerical Stability Analysis of a Natural Circulation Steam Generator with a Non-uniform Heating Profile over the tube length

Experimental Investigation of a Multi Effect Membrane Based Regenerator for High Concentration Aqueous LiCL Solution as Desiccant

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

MINIATURE HEAT TRANSPORT SYSTEMS WITH LOOP HEAT PIPES

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Technical Manual Ionisation Chamber MUSIC80

Variable far infrared radiation (VFIR) technique for cubic carrot drying

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

Off Design Operation of Hybrid Noncondensable Gas Removal Systems for Flash Steam Cycle Geothermal Power Plants

D R A F T. Testing of performance of precooling refrigerator in the fill/vent line at Indiana. Revision: 0.00

0Effect of Fin on the Performance Characteristics of Close and Open Loop Pulsating Heat Pipe

EXPERIMENTAL AND THEORTICAL STUDY OF THE THERMAL PERFORMANCE OF HEAT PIPE HEAT EXCHANGER

Available online Journal of Scientific and Engineering Research, 2018, 5(11): Research Article

Pocket Dilution Cooler

CLOVER DRYING PROCESS BY FORCED CONVECTION

PASSIVE HEAT EXCHANGER ANTI-FOULING FOR SOLAR DHW SYSTEMS

Heat pump supplemental heating system for motor vehicles

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

EXPERIMENTAL PERFORMANCE INVESTIGATION OF SWIRLING FLOW ENHANCEMENT ON FLUIDIZED BED DRYER

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Modifications and Improvements to the NPDGamma Liquid Hydrogen Target System and Safety

Passive Indirect Evaporative Cooler

TRANSIENT MODELING OF HYBRID LOOP HEAT PIPE SYSTEMS WITH MULTIPLE EVAPORATORS

CHAPTER 2 EXPERIMENTAL APPARATUS AND PROCEDURES

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

Performance Study of Triple Concentric Pipe Heat Exchanger

Laser Damage Measurements

SCIENCE CHINA Technological Sciences

Heat Exchanger Joule-Thomson Transient Cryogenic Refrigeration. Iranian Journal of Chemical Engineering Vol. 14, No. 3 (Summer 2017), IAChE

Heat Transfer Analysis of Vapor Compression System Using Nano Cuo-R134a

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

A STUDY ON THE BEHAVIOR OF STEAM CONDENSATION IN U-SHAPED HEAT TUBE

A Method of Heat Exchange Structure Optimization of the Cricoid Plastic Parts

15. Heat Pipes in Electronics (1)

Module 5: Combustion Technology. Lecture 38: Combustion Burners

A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Texas active target (TexAT) detector part 1: Design and construction progress

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Adsorption refrigeration system using waste heat

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

Theoretical Performance Analysis of a Liquid Desiccant Air- Conditioning System for Air Heating and Cooling

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Open Cycle Liquid Desiccant Air Conditioning Systems Theoretical and Experimental Investigations

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

Hot Reservoir Stainless-Methanol Variable Conductance Heat Pipes for Constant Evaporator Temperature in Varying Ambient Conditions

STUDY ON THE CONTROL ALGORITHM OF THE HEAT PUMP SYSTEM FOR LOAD CHANGE

SYNCHROTRON RADIATION ABSORPTION AND VACUUM ISSUES IN THE IR*

SOLAR PARABOLIC COLLECTOR ASSISTED EVAPORATIVE COOLING SYSTEM

PERFORMANCE ANALYSIS AND CALCULATION OF DIFFERENT PARAMETERS OF CONDENSER USING ANSYS FLUENT SOFTWARE

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

COOLING OF DESKTOP COMPUTER USING HEAT PIPES

Can one cool the MICE magnets and the Hydrogen Absorbers with Small Coolers? Michael A Green Oxford University Physics Oxford OX1 3RH, UK

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Introduction of the Design Features of Cryogenic Pumps and Expanders for FSRU Applications

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

All rights reserved, Armando B. Corripio, PhD, PE, Solid Dryer Design Introduction Continuous Dryer Design...

Economic Analysis of Solar Assisted Chemical Heat Pump Dryer

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

EFFECT OF PAG OIL CIRCULATION RATE ON THE HEAT TRANSFER PERFORMANCE OF AIR-COOLED HEAT EXCHANGER IN CARBON DIOXIDE HEAT PUMP SYSTEM

Design and Construction of a Simple Standing Wave Thermoacoustic Refrigerator

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Falling Film Heat Exchangers for Solar Water Heaters

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

SIMULATION ANALYSIS ON THE FRESH AIR HANDLING UNIT WITH LIQUID DESICCANT TOTAL HEAT RECOVERY

Heated tools. Semiconductor equipment

Basic CFD model of heat pipe

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

MULTI-CHANNEL R134A TWO-PHASE FLOW MEASUREMENT TECHNIQUE FOR AUTOMOBILE AIR-CONDITIONING SYSTEM

Conductive Heating Technologies for Medical Diagnostic Equipment. Russell Strehlow, Manager of Research and Development, Minco

PERFORMANCE OF A MODEL IN-LINE VORTEX SEPARATOR. Keng-Choon Lee Geothermal Institute, The University of Auckland, Private Bag 92019, Auckland, New

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Design and Fabrication of a Cool Box for Passenger Car using Automotive Air-conditioning System

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

EVALUATING LOOP HEAT PIPE PERFORMANCE IMPROVEMENT USING CIRCUMFERENTIAL GROOVES. Nadjara dos Santos, Roger R. Riehl

Transcription:

6 th Conference on Nuclear and Particle Physics 17-21 Nov. 2007 Luxor, Egypt A THIN GOLD COATED HYDROGEN HEAT PIPE -CRYOGENIC TARGET FOR EXTERNAL EXPERIMENTS AT COSY M. Abdel-Bary a, S. Abdel-Samad a, G.A.Elawadi a, K. Kilian b, J. Ritman b a Atomic Energy Authority, NRC, Cyclotron Project, 13759 Cairo, Egypt b Institut für Kernphysik, Forschungszentrum Jülich, D-52425 Jülich, Germany Abstract A gravity assisted Gold Coated Heat Pipe (GCHP) with 5-mm diameter has been developed and tested to cool a liquid hydrogen target for external beam experiments at COSY. The need for a narrow target diameter leads us to study the effect of reducing the heat pipe diameter to 5mm instead of 7mm, to study the effect of coating the external surface of the heat pipe by a polished gold layer (to decrease the radiation heat load), and to study the effect of using the heat pipe without using 20 layers super isolation around it (aluminized Mylar foil) to keep the target diameter as small as possible. The developed gold coated heat pipe was tested with 20 layers of super isolation and without. The operating characteristics for both conditions were compared to show the advantages and disadvantages. Keywords: Target/; Cryogenics/ Low temperature equipment/ Heat pipes. INTRODUCTION Nuclear reactions take place between accelerated particles and target materials. At the COoler SYnchrotron (COSY) interactions of protons in the GeV energy range with target nuclei are studied. The target materials in our experiments are liquefied hydrogen and deuterium. To liquefy them, a standard cooling machine (RGD 210 Leybold AG) is used (1) and the target is built on the 2 nd stage of this cooling machine as shown in figure (1). Earlier target versions used different heat conductors between the cooling machine and the target region (2). The longer and narrower heat link between the target and the cooler is needed for two reasons. Firstly, the cooler has to be as far as possible from the reaction point to avoid secondary interactions. Secondly, shadowing of the measuring detectors needs to be avoided. The shortest cooling down and heating up times were obtained with aluminum (the best heat conductor). A large improvement has been achieved by changing from metallic conduction to heat transfer by convection in heat pipes. Evaporation and condensation of a working fluid at opposite ends of a tube is used to transfer a large amount of heat (3-6). A 16 mm diameter heat pipe was developed and tested (7). Other improvements in the target performance were achieved by using aluminum instead of copper as the condenser and a 7mm-diameter heat pipe instead of 16mm (8). Further development is using a gold coated aluminum heat shield around the cold parts of the cold head and a 5 mm gold coated heat pipe (9). After the success of these developments and due to the cyclotron project, NRC, Atomic Energy Authority, 13759 Cairo, Egypt. Tel.: +202 44691743; fax:+202 44620786; email: mabdel-bary@hotmail.com -629-

need for narrower diameter targets the question was raised what is the lower limit of the target which still allows stable operation? To answer this question, a gold coated heat pipe with 5 mm diameter was designed and built without super isolation and heat shield. The internal plastic tube for the liquid flow from the condenser to the evaporator was kept at the same diameter of 3mm. The reduction in the heat pipe diameter only affects on the cross sectional area of the vapor flow from the evaporator to the condenser (12.56 mm 2 instead of 31.4 mm 2 for the 7mm diameter heat pipe). 20 layers super isolation Target cell Si diode 5 mm diameter gold coated HP (b) (a) Al condenser 2 nd stage 1 st stage Cooling machine Fig. (1): Standard cooling machine RGD 210 Leybold AG with target built on the 2 nd stage, (a) 5mm diameter gold coated heat pipe target, (b) 5mm diameter gold coated heat pipe target with 20 layers super isolation. The target liquid material is contained in a cylindrically shaped thin copper cell (wall thickness 30 µm) with 6mm diameter and 4 mm length fabricated by galvanization. The beam entrance and exit -630-

apertures are closed by using 0.9 µm Mylar foil (2). The hydrogen gas inside the heat pipe system has a pressure of 205 mbar at room temperature (filling pressure to have enough amount of liquid). This low pressure must be stabilized during the operation to higher and stable values than the hydrogen triple point (70 mbar, 13.9 K) to prevent the formation of solid hydrogen that stops the heat pipe operation. A pressure stabilization system (11) is used for that purpose. The study in this paper will concentrate on measuring the 5mm diameter gold coated liquid hydrogen heat pipe characteristics in two cases: 1. Heat pipe isolated with 20 layers aluminized Mylar foil (with super isolation). 2. Heat pipe without isolation by aluminized Mylar foil (without super isolation). The measurements were done at 40 inclination with respect to the horizontal plane. For both conditions, the cool down time for hydrogen has been measured (section 3). The temperature difference between the condenser and the evaporator of the heat pipe has been measured and compared (section 4). The effective thermal conductivity (section 5), the liquid hydrogen mass (section 6), a comparison between the 16 mm, the 7 mm, and the 5 mm diameter heat pipes (section 7) have been done. HEAT PIPE DIMENSIONS AND DESIGN 40 mm diameter Gas input 16mm Condenser section Control heater 4mm Aluminum condenser 16mm diameter Liquid collector Adiabatic section Inner plastic tube (3mm diameter) 5mm diameter 40 Resistors Evaporator section Beam direction Si diode Target cell Fig. (2): Schematic diagram for the condenser- 5mm gold coated heat pipe-target combination -631-

A gold coated ( 0.1 µm polished gold layer) -5mm diameter-32cm long heat pipe with 0.1mm wall thickness from stainless steel was developed. The material, the surface area, the thermal heat radiation, and the heat capacity have been reduced compared to the previously used 16 mm and 7mm diameter heat pipes. An aluminum condenser with a control heater around it was used in the upper part. Also a gold coated target appendix with very thin copper walls (30 µm, made by galvanization) was used in the lower part as the evaporator. Attached to the target appendix is a small resistor (160Ω) to allow a heat load in addition to thermal radiation to be applied to the target (applied heat load). A 3- mm diameter plastic tube with 0.1 mm wall thickness was used in the center of the heat pipe for liquid transportation between the condenser and the evaporator and it is identical to the one used for the 16 mm and 7 mm heat pipes. Figure (2) shows a schematic diagram of the heat pipe with the target appendix, the internal tube, and the aluminum condenser. Table (1) summarizes the parameters of this developed target version. Table (1): Parameters of the 5-mm diameter gold coated heat pipe with an aluminum condenser. Total heat pipe length 320 mm Part with 16 mm diameter (condenser) 70 mm Part with 5 mm diameter (adiabatic) 200 mm Evaporator part 50 mm Wall thickness 0.1 mm Inner tube length 200 mm Outer diameter 3.2 mm Wall thickness 0.1 mm Weight of evaporator 0.735 g Weight of inner tube 0.385 g Weight of HP without gas connector 6.080 g Weight of gas connector 5.440 g Weight of Al condenser 22.540 g The total weight 35.180 g COOL DOWN TIME WITH LH 2 Hydrogen is used as the fluid material in the heat pipe and at the same time as the target material. The cool down time to have LH 2 in the target cell has been measured with the gold coated heat pipe covered with super isolation and free from super isolation (without super isolation). The difference between the cool down times is 4 minutes. The time dependence of the condenser and evaporator temperatures with and without super isolation at the filling condition (205 mbar, 6.13 liter) is shown in Figure (3). The condensation of hydrogen around the aluminum condenser started 39 minutes after switching on the cooling machine. The total cool down time from starting the cooling until the LH 2 reaches the target cell is 44 and 48 minutes with and without super isolation, respectively. Thus, 5 and 9 minutes respectively are required for the liquid to proceed down and reach the evaporator section. During that time the liquid must cool down the internal plastic tube over its full length. Afterwards, 0.54 cm 3 of LH 2 is present in the system. Thereafter, only a couple seconds are needed to fill the target cell with LH 2. Finally, the system has a steady rate of condensation on the condenser and flow of liquid down in the inner tube, vaporization in the evaporator and flow of vapor upwards in the space between the 3mm diameter inner tube and the 5mm diameter heat pipe. The cool down time -632-

without using super isolation is longer because of the thermal radiation from the surroundings. This can be estimated from black body radiation formula 4 4 P = σ A ε ( Toutside T surface ), (1) Where σ is the Stefan-Boltzmann constant = (5.7 10-8 W m -2 K -4 ), A is the surface area of the 5mm heat pipe (7.4 E-3 m 2 ), ε is the emissivity of the surface (polished gold = 0.018), T surface. =15 K, T outside =300 K. From that the thermal radiation power to the polished gold coated 5mm heat pipe target system is 61.0 mw and for the polished gold coated 5mm heat pipe with super isolation target system is 15.0 mw. So the liquid takes longer to reach the target cell. In both cases the heat pipes work with the applied heat loads. 350 300 Evaporator temp. 250 Temperature (K) 200 150 Condenser temp. with s. isolation without s. isolation 100 50 0 0 10 20 30 40 50 60 Time (Min.) Fig. (3): Time dependence of the condenser and evaporator temperatures for LH 2 for 5mm diameter gold coated heat pipe with and without super isolation. TEMPERATURE DIFFERENCE BETWEEN THE ENDS OF THE HEAT PIPE The temperature difference T between the external surface of the evaporator and the external surface of the condenser of the heat pipe target system is measured as a function of the applied heat load on the evaporator at different condenser temperatures. A small T allows us to operate the cold head at a higher temperature where higher cooling power is available (10). Figure (4) shows the measured T for different applied heat loads at the evaporator for different condenser temperatures in steady-state operating conditions with and without super isolation. T increases with increasing the applied heat load at the same condenser temperature, increases with increasing condenser temperature for the same applied heat load (due to the reduction of the heat pipe thermal conductivity), and increases without using super isolation at the same condenser temperature and applied heat load (due to the increased radiation heat load on the heat pipe). -633-

Temperature difference (K) 0.5 0.4 0.4 0.3 CT_14.9K-WI 0.3 CT_15.1K-WI 0.2 CT_15.3K-WI CT_15.5K-WI 0.2 CT_14.9K-WOI 0.1 CT_15.1K-WOI 0.1 CT_15.3K-WOI CT_15.5K-WOI 0.0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Heat load (W) Fig. (4): Temperature differences between the condenser and the evaporator of the hydrogen gold coated heat pipe versus the applied heat loads at the evaporator for different condenser temperatures with (solid curves) and without (dashed lines) the super isolation. 400 Effective thermalconductivity (W/cm.K) 350 300 250 200 150 100 50 CT_14.9K-WI CT_15.1K-WI CT_15.3K-WI CT_15.5K-WI CT_14.9K-WOI CT_15.1K-WOI CT_15.3K-WOI CT_15.5K-WOI 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 Heat load (W) Fig. (5): Effect of applied heat load on K eff for the hydrogen 5mm diameter gold coated heat pipe target system for different condenser temperatures with (solid curves) and without (dashed lines) the super isolation. -634-

When the applied heat load on the evaporator exceeds a certain maximum value the LH 2 will evaporate completely from the evaporator and its temperature will increase. The T ranges from 0.018 to 0.395K with using super isolation and from 0.032K to 0.383 K without using super isolation depending on the condenser temperature and the applied heat load. The heat pipe system can transfer up to 1.1W applied heat loads with the super isolation compared to 1.7 W applied heat load for the 7mm diameter heat pipe with super isolation and without gold coating. The 5mm diameter gold coated heat pipe ceases to operate at 1.1 W heat load although it still has enough liquid quantity inside. This is because there is only 40% of the cross sectional area for vapor flow compared to the 7 mm heat pipe. The correspondingly much faster flow of vapor upwards hinders the liquid flow downward to the evaporator. EFFECTIVE THERMAL CONDUCTIVITY OF THE HEAT PIPE The effective thermal conductivity (K eff ) gives an indication of the additional heat flow rate resulting from the applied heat load. High values are required for a stable working target. The K eff for the heat pipe system (12-14) is determined by the following equation: L Q K eff =, (2) T A where Q is the heat transfer rate, T is the temperature difference between evaporator (T2) and condenser ( T 1 ), L is the distance between the measuring points of T 1 and T 2 and A is the crosssectional area of the heat pipe. Figure (5) shows the effective thermal conductivity K eff of the hydrogen heat pipe-target system as a function of the applied heat load for different condenser temperatures with super isolation (WI) and without (WOI). The results show that K eff increases with increasing the applied heat load, with decreasing the condenser temperature and with using super isolation around the heat pipe at the same applied heat load and condenser temperature. The K eff decreases with increasing the condenser temperature because of the increase in condenser temperature decreases the condensation rate of liquid which leads to an increase in the temperature difference T and then decrease in the K eff. The highest measured thermal conductivity with super isolation is 376.5 W/cm K compared with 353 W/cm K without using super isolation. LIQUID MASS IN THE HEAT PIPE-TARGET SYSTEM The heat pipe working fluid is the target material used for the nuclear reactions (liquid hydrogen). The target system should have sufficient liquid for proper operation of the heat pipe and complete filling of the target cell. The gas filling in the heat pipe system is (1.24 l atm). For the target and heat pipe operation a fraction of the available gas is converted into liquid. The change in the gas content is determined by the changes in the volume of the bellow V and the pressure (10). The mass of vapor removed from the bellow (m v = V ρ gas(295k, P) ) is converted into the mass of cold gas in the heat pipe (m cg = V HP ρ cg (200 mbar, sat) ) and the liquid mass in the system (m l = m v m cg), where V HP is the volume of the heat pipe and m l is the mass of liquid in the heat pipe target system. The subscripts p, cg, sat, v, l, HP indicate pressure, cold gas, saturation, vapor, liquid and heat pipe, respectively. In the 32 cm long target system some liquid is needed above the evaporator. Due to the condensation of the hydrogen around the condenser and the flow of the liquid in the inner plastic tube, part of the liquid adheres to the surface of the condenser and the inner tube (0.54 cm 3 ). The quantity required in the target cell and appendix is nearly equal to that value (it is 0.5 cm 3 which corresponds to 38 mg LH 2 ). Figure (6) shows the amount of liquid H 2 in milligrams inside the 5 mm diameter heat pipe target system at various condenser temperatures and applied heat loads. The liquid mass decreases with increasing condenser temperature and increasing applied heat load on the evaporator due to the -635-

decrease in condensation rate in the condenser section and the increase in vaporization in the evaporator (target). The 5 mm diameter gold coated heat pipe operation stops even though there is enough liquid (dotted line in figure (6)) inside it. The reason why the heat pipe ceases to operate is that the high speed of the vapor proceeding upward (64 cm/s) prevents the liquid from flowing downward in the inner plastic tube. 120 0.1W 100 0.2W 0.3W LH2 Mass (mg) 80 60 40 20 0.4W 0.5W 0.6W 0.7W 0.8W 0.9W 1.0W op_limit 0 14.7 14.9 15.1 15.3 15.5 15.7 Condenser temp.(k) Fig. (6): Mass of liquid hydrogen inside the 5 mm gold coated heat pipe target system versus the condenser temperature at different applied heat loads and the heat pipe operation limits (dashed curve). COMPARISON The comparison between the 16 mm, 7 mm, and 5 mm diameter heat pipe aims to show the advantages and disadvantages of them. This comparison allows further optimization of the heat pipe depending on the following parameters: The weight of the heat pipe should be minimized in order to decrease the background reactions. The cool down time should be as short as possible in order to optimally use the very expensive COSY beam time. The target average external diameter should be as small as possible in order to decrease the space used within the detector system and thus decrease the shadowing. The thermal conductivity should be as high as possible in order to increase the sensitivity and the response to the changes in the heat loads. The maximum temperature difference between the condenser and evaporator should be as small as possible in order to allow the cooling machine to work at higher condenser temperature and thus provides more cooling power (10). The heat pipe surface area should be as small as possible in order to decrease the radiation heat load which is directly proportional to the surface area of the heat pipe. -636-

Table (2) summarizes the parameters of the heat pipes. From the table, one can select the heat pipe diameter depending on the used detector system and the type of measurements (liquid or gas target measurements). Table (2): Comparison between the 16mm, 7mm, and 5-mm diameter heat pipes with an aluminum condenser. 16 mm diameter heat pipe with super isolation 7 mm diameter heat pipe with super isolation 5 mm diameter gold coated heat pipe without super isolation with super isolation Weight with Al condenser (g) 41.5 36.7 35.1 35.1 Cool down time (minutes) 57 47 48 44 Maximum K eff (W/cm K) 80 422 353 377 Maximum temp. difference (K) 0.27 0.24 0.383 0.395 Heat pipe surface area (cm 2 ) 133.2 77 66.5 66.5 Maximum heat load (W) 1.0 1.4 1.0 1.1 Average external target diameter (mm) 40 35 5 30 Maximum vapor speed (cm/s) 3.7 32.3 57.3 63.7 CONCLUSION In this study a 32 cm long stainless steel-gold coated heat pipe with 5mm diameter has been developed. The heat pipe was tested with hydrogen gas with and without super isolation. The heat pipe operation was successful without super isolation around it which is a good advantage to decrease the shadowing effect for the detectors and background measurements. As advantages the 5 mm heat pipe has, Low mass: that means it has a lower heat capacity, shorter cool down time and generates less background. Small surface area: that means it is exposed to a lower radiation heat load from the surroundings. -637-

Small diameter: that means it makes lower detector shadowing and needs less volume in the detector system. The cool down times were 44 and 48 minutes with and without super isolation, respectively. The maximum effective thermal conductivities were (376.5, 353W/cm K), the maximum temperature difference between the condenser and evaporator were (0.395, 0.383 K), the vapor flow velocities were (63.6, 57.3cm/s), and works with maximum applied heat loads up to 1.1W and 1.0W with and without super isolation, respectively. Although the 5mm diameter gold coated heat pipe has those advantages, it is not the optimal diameter because the small cross sectional area used for the vapor flow upward which results in a high vapor velocity. This resists the liquid from flowing downward in the inner plastic tube. As a result, the heat pipe stops to operate even though there is still enough liquid inside it. Furthermore, there is a high temperature differences between the condenser and evaporator which requires the cooling machine to work at lower condenser temperatures where there is lower cooling power. REFERENCES (1) Leybold AG. Vacuum technique and cryogenerators. Germany: Köln; (1999). (2) S. Abdel-Samad, Improving the Properties of Cryogenic Targets for External Cooler Synchrotron (COSY) Experiments; Ph.D. thesis, FZ Juelich/Aachen University, Germany (2001). (3) Faghri, Heat Pipe Science and Technology; Taylor & Francis, Washington (1995). (4) S. W. Chi, Heat Pipe Theory and Practice; McGraw-Hill, Washington (1976). (5) P. D. Dunn, et al., Heat Pipes; 4th Edition, Pergamon Press, New York (1994). (6) J. Geue, Heat Pipes and Their Applications; Atomic Energy Commission Lucas-Heights, Australia (1971). (7) S. Abdel-Samad, et al., New developments in cryo-targets for the external COSY experiments; Nucl. Instr. and Methods in Physics Research A; 495, 1 (2002). (8) M. Abdel-Bary, et al, A Very light and Thin Liquid Hydrogen Target for COSY Experiments; Cryogenics; volume/ Issue 45/ 7, 489 (2005). (9) S. Abdel-Samad, et al., Cryogenic Target with very thin "gold finger" Heat Pipe; Nucl. Instr. and Methods in Physics Research A; 556, 20 (2006). (10) M. Abdel-Bary, Development of a Cryogenic Target System with Optimal Access to Reaction Detectors; Ph.D. thesis, FZ Juelich/Aachen University, Germany (2004). (11) M. Abdel-Bary, et al., Performance Measurements for a 7mm-Diameter Hydrogen Heat Pipe; Cryogenics; Volume 47, 158 (2007). (12) G. P. Peterson, An introduction to Heat Pipes, Modeling, Testing and Applications; John Wiley & Sons, Inc. (1994). (13) C. Wongee, et al., An Experimental Study of the Utilization of Heat Pipes for Solar Water Heaters, Applied Thermal Engineering; Vol. 19, 807 (1999). (14) A. Abo El-Nasr and S. M. Haggar, Effective Thermal Conductivity of Heat Pipes; J. Heat and Mass Transfer; Springer-Verlag press, Vol. 32, 97 (1996). -638-