GAS-FIRED FLOOR-STANDING BOILERS

Similar documents
Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

Ciao Green Condensing Wall-Hung Boilers

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

Floor standing boilers. RMG Mk.II RS Mk.II

Mynute Green k. Condensing Wall-Hung Boilers. Residential Heating

CITY OPEN - CITY BOX from 25 to 35 kw

Ideasandformsinevolution

Fonte Lx NEW. Instantaneus Gas Water Heaters, conventional flue, low NOx. Residential Heating. compliant. Fonte Lx 14. Fonte Lx 11

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

white blue cobalt bordeaux light oak (rovere)

Wall hung combination

Mynute Green Condensing Wall-Hung Boilers

Bluehelix Tech RRT Wall-hung condensing boiler with Ferroli Thermobalance heat cell

Exclusive Green E Condensing Wall-Hung Boilers

1 VICTRIX ZEUS Superior kw I features

Tower Green HE Hybrid

C Tahiti. condensing

Condensing, pre-mixed, wall-hung gas boilers with water tank

Power X High Power Condensing Wall-Hung Boilers

PCH/new Series. High performance, total flexibility

FORMENTERA KC - KRB - KR

RMG MK. II RMG Mk.II RS Mk.II RMG Mk.II RS Mk.II

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Power X High Power Condensing Wall-Hung Boilers

The iqe Boiler Range. Combination and System T Boilers.

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

ENERGY TOP. Condensing boiler solutions

AGUAdensT TM 100% commercial condensing D.H.W. commercial water heaters from 70 to 280 kw AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

TRADITIONAL NIKE/EOLO STAR. Wall-hung combi boilers

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

The mechatronics of EVE 05

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

MINORCA KC - KR - KRB 24

ALKON 90 ALKON 90 MODEL 24,0 93,6 21,1 87, nominal heat output. conventional. max/min heat input. efficiency class (Directive 92/42)

Pure technology. Clean design and practical panel board with wide Power save display !DEA AR 23 !DEA RS !DEA AC 23 !DEA CS

BWA. CONDENSING WALL HUNG BOILER FROM 50 kw TO 140 kw

wall-mounted boilers, water heaters and pool heaters floor standing boilers, water heaters and pool heaters

CONDEXA PRO EXCELLENCE AND VERSATILITY

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

SPECIFICATIONS - NIKE

Efficient heating that won t cost the earth

gas condensing combi boiler

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

Bluehelix Tech Wall-hung premix condensing boilers, only heating or instant combi operation

STILE BEAUTY AND TECHNOLOGY

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

IST 03 C ANTEA CONDENSING EN INSTALLATION, USE & MAINTENANCE MANUAL

Rapid. Suspended Warm Air Heater. Caring for the environment!

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

THE PERFECT CONDENSATION

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

PRODUCT GUIDE 2018/19 ACV HEATING AND HOT WATER SPECIALISTS

MADE IN ITALY. Quality makes the difference. For 50 years. Product Guide

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

C Nias Dual. Wall-hung boilers, forced draught, sealed chamber with storage tank. For indoor installation. Life-enhancing heat

White paper: New Ecodesign rules and energy labelling for space and water heaters

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

HIGH OUTPUT. Skin design RANGE

So old fashioned... As the combustion chamber is completely room sealed, it does not release any smells and does not dirty.

VERTINOX. AISI 316 stainless steel accumulators with one or two heat exchangers, fixed or removable type

Seradens Super Seradens Super Plus

thea 35 MR/MN Kondens Wall-mounted condensing boiler

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

2530C / 3035C / 3540C. Condensing ErP Boilers. Enerwa EnerwaPlus

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

PCH Heating Condensing Module for Air Handling and Roof Top Units

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

CRIMSON & CRIMSON MAX

Capri B Cast iron combination oil-fired boiler with water tank

HEAT PUMPS EN - flyer 10/p/2017 Made in Poland

Do you want a versatile solution

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

4FLOOR-STANDING GAS CONDENSING BOILERS

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

Sirius FS. Working towards a cleaner future

Smart Collection. April 2012

TopGas Wall Hung Condensing Gas Boiler

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

WOLF GAS CONDENSING BOILERS COMFORTLINE

ACCUMULATION OF EUROPEAN CLASS

INSTRUCTION FOR THE USER THC V E OIL BLU

RENEWABLE ENERGY THERMAL SOLAR ENERGY. RENEWABLE ENERGY...pag. 05

C Elba Dual. Cast-iron, floor-standing boiler. High quality Italian product. Life-enhancing heat

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

AQUAMATIC HOT WATER IS YOUR NEW WELLNESS. Instant producer of sanitary hot water

MySMART Condensing Wall-Hung Boilers

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

PRODUCT GUIDE HIGH EFFICIENCY HOT WATER AND HEATING PRODUCTS

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

ANTEA KC - KR - KRB

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Transcription:

GAS-FIRED FLOOR-STANDING BOILERS Atlantis HM ErP Kombi Solar HE ErP Logo ErP

The best floor-standing boiler by Sime Sime, boasting a long and renowned tradition in the production of floor-standing boilers, offers the market a range of high-tech products to satisfy the broadest spectrum of heating and user needs: - Atlantis HM ErP: premix condensing boilers with hot water storage and heating only - Kombi Solar HE ErP: premix condensing boilers with solar integration in heating and D.H.W. production. Also available in Drain Back version with additional tank to collect the heat-transfer fluid in drainback solar hot water systems. - Logo ErP: natural draught cast iron boilers with low pollutant emission and hot water storage. A complete range Model Integration with forced solar system Integration with Drain Back solar system Kombi Solar HE 30 ErP Kombi Solar HE 30 DB ErP Atlantis HM 30 T ErP Atlantis HM 30 T SP ErP * Atlantis HM 30/50 ErP Atlantis HM 30/110 ErP Atlantis HM 30/300 ErP Logo 30/50 ErP Logo 30/110 ErP * version with plate heat exchanger to insulate boiler circuit from heating system Heating only Storage water heater in stainless steel 2

Atlantis HM 30/50 ErP Atlantis HM 30/110 ErP Logo 30/50 ErP Logo 30/110 ErP Kombi Solar HE 30 ErP Product benefits ATLANTIS HM ErP > Modulation ratio 1:10 > High-efficiency modulating circulator pump and delivery and return sensors to manage heating at constant T > Integrated climate regulation with external sensor supplied standard > Reduced noise emissions > Integrated management of up to two circuits, one with low and another with high temperature (optional) > Cascade management, ModBus protocol (optional) KOMBI SOLAR HE ErP > High-efficiency circulator pump > Integrated climate regulation with external sensor supplied standard > Solar thermal integration to support domestic hot water and heating functions > High and low temperature integrated circuit management (optional) > High solar contribution in both mid-seasons and winter, with the possibility to connect up to 3 solar collectors without stagnation (Drain Back version) LOGO ErP > Open chamber boiler with high-efficiency circulator pump > Integrated climate regulation > High and low temperature integrated circuit management (optional) 3

An expandable system All boilers in the range allow climate regulation thanks to an external sensor (supplied standard for Atlantis HM ErP and Kombi Solar HE ErP) and help to reduce heating system operating costs. Two different thermostats can be connected to manage two circuits with differented temperatures. Using an optional kit that can be integrated into the boiler, the generators can satisfy all system needs (see table). All boilers are designed to allow combination with a solar thermal system. Using the InSOL kit, the boiler can manage a forced circulation solar system. ROOM TEMPERATURE EXTERNAL TEMPERATURE TEMPERATURE OF HEATING BODIES Atlantis HM ErP 30 T 30/110 30/300 Kombi Solar HE ErP 8100784 Kit 2 low temperature zones + pre-assembled high temperature zone 8100787 Kit 2 low temperature zones + pre-assembled high temperature zone 8100783 Kit low temperature zone + pre-assembled high temperature zone 8100786 Kit low temperature zone + pre-assembled high temperature zone 8100785 Kit 2 pre-assembled high temperature zones 8100788 Kit 2 pre-assembled high temperature zones 8100740 Kit second pre-assembled high temperature zone 8100741 Kit second pre-assembled low temperature zone 8100762 Kit low temperature zone + pre-assembled high temperature zone 8100763 Kit 2 low temperature zones + pre-assembled high temperature zone 8100764 Kit 2 pre-assembled high temperature zones 8092235 InSOL kit * * Logo ErP 30/50 30/110 * The InSol kit is supplied standard with the Atlantis HM 30/300 ErP and Kombi Solar HE ErP models 4

EXAMPLES OF SOLAR SYSTEMS CONTROLLED BY KIT INSOL COD. 8092235 IMPIANTO SOLARE FORZATO DRAIN BACK CON CALDAIA SOLO RISCALDAMENTO Caldaia solo Heat riscaldamento only boiler Caldaia solo Heat riscaldamento only boiler M 1 FORCED SOLAR SYSTEM (also DRAIN BACK) WITH HEAT ONLY BOILER 2 DOUBLE-PITCHED FORCED SOLAR SYSTEM WITH HEAT ONLY BOILER Caldaia solo Heat riscaldamento only boiler 3 FORCED SOLAR SYSTEM WITH TANK IN TANK WITH BOILER HEAT ONLY PER-HEATED RETURN IMPIANTO SOLARE FORZATO DOPPIA FALDA CON PIPE IN TANK CON CALDAIA SOLO RISCALDAMENTO, RISCALDAMENTO DIRETTO Caldaia solo Heat riscaldamento only boiler M M FORCED SOLAR SYSTEM DOUBLE-PITCHED WITH PIPE IN TANK WITH HEAT ONLY BOILER 4 DIRECT HEATING IMPIANTO SOLARE FORZATO CON DOPPIO ACCUMULO IN PRIORITA CON CALDAIA SOLO RISCALDAMENTO Caldaia solo Heat riscaldamento only boiler M 5 FORCED SOLAR SYSTEM WITH PRIORITY DOUBLE STORAGE WITH HEAT ONLY BOILER 5

Modern and practical interface The floor-standing range is equipped with a control panel that characterizes the look of the boiler, in two separate areas one for the user and one for the installer. Underneath the lower hatch, there is an 8-button keypad allowing intuitive control by the user. Above the LCD display, the hatch hides an area reserved to installers/ technicians, characterised by four buttons and a PC data connection port, in addition to a space for the eventual installation of a timer. INSTALLER interface Backlit display SHOWING all the most important information User interface LED status indicator BLUE: in operation - RED: in alarm Atlantis HM ErP High modulation In recent years, the increased thermal efficiency of buildings has significantly reduced the thermal load of homes (30-35 Watt/m 2 ). For a home with a surface area of 100 m 2 an average output of 3.0-3.5 kw is enough, or even less in the case of smaller surface areas. A traditional condensing boiler will therefore continuously turn on and off, partially offsetting the benefits of its high combustion efficiency. The Atlantis HM ErP output automatically and continuously varies between a minimum of 2.95 kw to a maximum of 29.5 kw. The high modulation minimises generator stop and start phenomena, improving the boiler's seasonal efficiency. The average European home consumes 290 kwh/m 2 per year, while more efficient class A homes consume less than 30 kwh/m 2 per year. SOURCE: Sustainable Energy without the hot air by David JC MacKay p.299. The ultra-low minimum output of the Atlantis HM ErP (2.95 kw) is particularly advantageous when heating new, high energy efficient homes that require minimal power. 6

Atlantis HM ErP High-efficiency circulator pump Maximum energy efficiency in condensing boilers is obtained when the system return temperature is 45-50 C. For this reason it is common thought that a condensing boiler should be connected to low temperature heating systems. With Atlantis HM ErP, the flow rate is automatically reduced if necessary, thereby increasing the energy transferred to the house, while reducing the temperature of the return water. Therefore, provided the initial settings are correct, Atlantis HM ErP is able to self-adjust and continuously work in a condensing regime, regardless of the type of system it serves. The variable flow rate circulator pump is therefore extremely useful when replacing boilers in traditional radiator systems, for which it is advised not to use older versions of condensing boilers. HIGH CIRCULATOR PUMP SPEED V c =V max SM LOW CIRCULATOR PUMP SPEED V c = V 1 / 3 max SM SR SR 97% 108% 100 75 50 25 0 100 75 50 25 0 Delivery T ( C) Return T ( C) Efficiency (%) Thanks to the variable speed circulator pump (V c ) and control system, Atlantis HM ErP guarantees continuous maximum combustion efficiency even in cases where old boilers that work with traditional radiator systems are replaced, offering performance levels comparable to a condensing boiler connected to a floor heating system. Atlantis HM ErP Cascade management, ModBus protocol Atlantis HM ErP floor-standing boilers can* be connected in a cascade to deliver maximum power equal to the sum of the outputs of each generator. Up to 8 Atlantis HM ErP boilers can be managed in a cascade, thereby developing a heat source able to provide an output between a minimum of 2.9 kw up to a maximum of 29.5 x 8 = 236 kw. Moreover, Atlantis HM ErP, whether alone or in a cascade, can be integrated into a more complex climate control system equipped with its own control and regulation device, able to communicate with Atlantis HM ErP using the MODBUS protocol. SIME KIT FOR CASCADE MANAGEMENT 8092243 RS-485 kit for cascade management (1 per generator) 8092244 RS-485 kit for MODBUS communication * One RS-485 kit is needed for cascade management and one RS-485 kit to connect one Atlantis HM ErP boiler in a MODBUS network. 7

Atlantis HM ErP An answer to every need Atlantis HM ErP is available in 5 versions: Atlantis HM 30 T ErP: heating only version with incorporated diverter valve for combination with external water tanks Atlantis HM 30 T SP ErP: heating only version with incorporated diverter valve for combination with external water tanks and plate exchanger to insulate boiler circuit from system Atlantis HM 30/50-30/110 ErP: combined versions with 50- and 110-litre stainless steel water tank Atlantis HM 30/300 ErP: combined version with 300-litre stainless steel dual coil water tank and integrated management of a forced solar thermal circuit Atlantis HM 30/50 ErP Atlantis HM 30/110 ErP ATLANTIS HM 30 T ErP This is the most compact boiler in the range and can be directly connected to the heating system. It includes a diverter valve to allow connection to an external domestic hot water storage tank. If a dual coil storage tank is selected, a forced solar thermal system can be managed using the optional InSol kit cod 8092235. 8

ATLANTIS HM 30 T SP ErP It has the same characteristics as the Atlantis HM 30 T Erp, but is supplied standard with a plate exchanger that separates the combustion chamber from the rest of the heating circuit. This version is particularly suited to replace generators connected to older heating systems, in which dirt and debris may have accumulated over the years. Atlantis HM 30 T SP ErP on the system side is complete with pump, expansion tank, filter, safety valve, inlet valve, delivery sensor and hydrometer. S3 ATLANTIS HM 30/50 ErP Includes a 50-litre stainless steel storage tank and is the smaller of the models able to produce domestic hot water. It is the boiler for users with limited space, looking for high comfort and low consumption. ATLANTIS HM 30/110 ErP With a 110-litre stainless steel storage tank, this model is able to handle simultaneous requests of hot water from two bathrooms. It is the heat generator most suited to replace older floor-standing boilers in medium to large-sized homes. MB RB G M Mandata C.H. flow impianto R Ritorno C.H. return impianto MB Mandata D.H.W. tank bollitore flow RB Ritorno bollitore RB D.H.W. tank return G Alimentazione gas E G Entrata Gas supply acqua sanitaria U E Uscita D.H.W. acqua inlet sanitaria S3 U Scarico D.H.W. outlet condensa C S3 Caricamento impianto Condensate drain C Recirculation Hydraulic Circuito idraulico circuit Atlantis Atlantis HM HM30 30 T SP T SP M R C 9

ATLANTIS HM 30/300 ErP The most complete product in the range covers part of the hot water production using renewable solar energy. The 300-litre stainless steel hot water storage tank in Atlantis HM 30/300 ErP features a second coil for connection to solar collectors. The collectors are the only components not included, everything else needed to develop the solar system is in the boiler: solar hydraulic unit, expansion tank, solar control unit, sensors. Atlantis HM 30/300 ErP is the must-have solution for new medium and large-sized homes where legislation prescribes the use of renewable energy, and is the most valuable investment when refitting existing homes. BOILER BODY MURELLE HM ErP 30 kw MODULATING SYSTEM CIRCULATOR PUMP INTEGRATED MANAGEMENT OF ONE FORCED SOLAR THERMAL CIRCUIT it can accommodate optional kits for 3-zone management, including 2 mixed zones 300-LITRE DUAL COIL STAINLESS STEEL SOLAR STORAGE TANK atlantis 30/300 ErP: multizone system with kit cod. 8100784 and kit cod. 8092235 KIT INSOL KIT zonamix KIT zonamix CR 73 TA 2 TA 1 SONDA ESTERNA 10

Kombi Solar HE ErP Condensing and solar thermal integration Kombi Solar HE ErP is an innovative solution for the management of low consumption residential heating systems, efficiently combining condensing technology and solar thermal integration in small dimensions. The boiler is composed by three fundamental parts: the condensing heat exchanger, the 200-litre dual coil storage tank for the heating circuit and the solar thermal system components. The primary storage tank exploits the solar energy to heat both the domestic hot water and heating system water, thereby increasing energy savings. In addition to guaranteeing maximum solar thermal integration, Kombi Solar HE ErP is able to manage multiple zones through optional kits that can be integrated into the casing. All this is managed by a single integrated electronic control unit in the boiler, through an intuitive user interface with LCD backlit semigraphic display. The system features variable temperature climate regulation. 11

Kombi Solar HE ErP Technology at arm's reach 30 KW CONDESING HEAT EXCHANGER 18-litre solar expansion tank 4-litre solar domestic hot water exp. tank hydraulic collector with high hydraulic head system pump Electronic control unit with solar circuit regulation and zone management zone kit (accessory) solar unit complete with circulator pump, solar valve and flow regulator primary 200-litre dual coil water heater Detail of water heater coils 12

Kombi Solar HE DB ErP (Drain Back) Automatic solar collector draining The Drain Back version of the Kombi Solar HE ErP improves the efficiency of the solar system during the winter period when solar irradiation is scarce and the demand for hot water is high for both domestic and heating use. To improve solar performance in the colder months, Kombi Solar HE DB ErP can be connected to a higher number of collectors without damaging the solar system in the summer months, when irradiation reaches its peak. To achieve this result, Kombi Solar HE DB ErP automatically drains the solar collectors when the system is inactive. In this way, the heattransfer fluid (generally water) of the collectors is drained when solar heating reaches high levels that would otherwise damage the system. DRAIN BACK OPERATING DIAGRAM SONDA SOLARE COLLETTORI SOLARI SONDA SOLARE COLLETTORI SOLARI SERBATOIO DRAIN BACK SERBATOIO DRAIN BACK OFF POMPA DRAIN BACK ON POMPA DRAIN BACK ACCUMULO A.C.S. COLD SOLAR STORAGE The Drain Back pump is idle. By way of gravity, the heat-transfer fluid (water without glycols) drains the solar collectors and pipes, filling up the Drain Back tank below. SONDA SOLARE 1 COLLETTORI SOLARI 3 ACCUMULO A.C.S. HEAT TRANSFER FROM COLLECTORS TO SOLAR STORAGE TANK When the temperature between the collectors and solar tank reaches the set value, the Drain Back pump will start to work. The pipes and solar collectors will fill up with heat-transfer fluid. The Drain Back tank will be partially emptied. The solar energy collected by the collectors heats the heat-transfer fluid, which transfers heat to the solar storage tank. 2 OFF SERBATOIO DRAIN BACK POMPA DRAIN BACK HOT SOLAR STORAGE When the solar storage temperature reaches the desired value, the Drain Back pump stops. The heat-transfer fluid stops, and falls by way of gravity, draining the solar collectors and pipes and collecting in the lower part of the system (Solar Storage and Drain Back tank) If the solar storage temperature falls due to the single or combined effect of: d.h.w. withdrawal primary water pre-heating cooling the procedure will start again from step 2. ACCUMULO A.C.S. 13

Logo EV The reliability of cast iron Cast iron is an alloy whose properties remain unaltered over time, and which is synonymous with reliability. For Logo Erp, a cast iron heat exchanger was designed using a Genetic Algorithm logic; a sophisticated software allows maximum heat exchange and minimum head loss, optimising the form, passage and surface of the body. Moreover, cast iron has high thermal inertia allowing more energy savings than other heat exchangers made with other materials. Logo EV Ecological and efficient systems The boilers are equipped with efficient combustion systems that reduce gas consumption and control pollutant emissions. The Logo ErP combustion system is defined as "hyperstoichiometric" or natural premixing, allowing combustion in the absence of secondary air and a constant air/gas ratio at any output, thanks to a special burner able to work with limited excess air; it also minimizes CO and NOx levels. Pollutant emissions fall largely below the limits of the strictest European regulations and boilers are classified as Class 5, the least polluting class established by regulations UNI EN 297 and 483. 14

Technical and safety features Continuous electronic flame modulation in heating and domestic hot water mode Automatic regulation of maximum start-up power in heating mode Management of two heating circuits with different temperatures Management of three heating circuits with different temperatures Antifreeze protection for heating and domestic hot water circuit Automatic ignition with flame ionisation Water/vapour exchanger in stainless steel Expansion tank for heating system Expansion tank for domestic hot water system (1) Expansion tank system side (2) Low NOx emission premix burner High-efficiency system circulator pump Post system pump circulation Post fan ventilation Atlantis HM ErP Kombi Solar HE ErP Double cut-off electric valve, which in the absence of a flame, interrupts the gas supply Automatic bypass on heating circuit Sweep function that facilitates combustion analysis Solar circulator pump (3) Integrated climate regulation External temperature sensor supplied standard INSOL solar mini-circuit board for complete management of solar system (3) 12-litre solar expansion tank with nitrile rubber membrane (3) (4) Drain Back system to prevent overheating phenomena and/or the freezing of the solar fluid (5) Logo ErP Thermostatic mixer (3) Superior hydraulic connections kit (optional) Possibility to connect up to three collectors without stagnation Numeric code self-diagnostics Safety thermostat Vapour sensor to protect the polypropylene drain pipe Vapour safety device 3 bar system safety valve 7 bar boiler safety valve (6) Low water level safety Inspectionable filter at domestic hot water inlet (5) (1) Not included in heat only versions (2) Atlantis HM 30 T SP version only (3) Atlantis HM 30/300 version only (4) Kombi Solar HE version only (5) Kombi Solar HE DB (Drain Back) version only (6) Only versions with boiler 15

Atlantis HM ErP ATLANTIS HM ErP MODEL 30 T 30 T SP 30/50 30/110 30/300 Nominal heat output (80-60 C) kw 28,8 28,8 28,8 28,8 28,8 Nominal heat output (50-30 C) kw 31,4 31,4 31,4 31,4 31,4 Minimum heat output (80-60 C) kw 2,7 2,7 2,7 2,7 2,7 Minimum heat output (50-30 C) kw 3,1 3,1 3,1 3,1 3,1 Useful power output (80-60 C) % 97,6 97,6 97,6 97,6 97,6 Useful power output (50-30 C) % 106,4 106,4 106,4 106,4 106,4 Useful perform. at 30% of the load (40-30 C) % 107,2 107,2 107,2 107,2 107,2 Heating energy efficiency class A A A A A Domestic hot water energy efficiency class B B B Domestic hot water load profile XL XXL XXL Heating sound power db (A) 45 45 47 42 41 Absorbed power (Qn max / Qn min) W 98 / 62 143 / 62 98 / 62 98 / 62 98 / 62 Electrical protection class IP X4D X4D X4D X4D X4D Heating regulation range C 20 80 20 80 20 80 20 80 20 80 Boiler water content l 6,4 4,5 9,7 9,7 5,8 Max operating pressure bar 3 3 3 3 3 Max operating temperature C 85 85 85 85 85 Heating expansion vessel capacity/pressure l/bar 10/1 2,5/1,5 10/1 10/1 10/1 System side expansion vessel capacity/pressure l/bar 10/1 Domestic hot water setting range C 10 65 10 65 10 65 Specific hot water flow rate (EN 13203) l/min 18,7 25,1 28,5 Continuous hot water flow rate T 30 C l/min 13,8 13,8 13,8 Min/max hot water pressure bar 0,2/7,0 0,2/7,0 0,2/7,0 D.H.W. storage tank capacity l 50 110 300 D.H.W. expansion vessel l 2,5 4,0 16 (8.0 x 2) Time of recovery from 25 to 55 C min. 6 20 12 45 16 30 NOx class 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) Boiler net weight kg 58 58 74 106 173 Maximum rectilinear length ø 60/100* m 5 5 5 5 5 Maximum rectilinear length ø 80/125* m 10 10 10 10 10 Maximum rectilinear length ø 80* m 50 + 50 50 + 50 50 + 50 50 + 50 50 + 50 Maximum rectilinear length ø 60* m 50 + 50 50 + 50 50 + 50 50 + 50 50 + 50 * horizontally with a 90 curve Overall dimensions 50 230 89 vers. HM 30 T - SP 173 50 vers. HM 30 T SP 230 G 268 70 70 70 70 70 70 70 M R M1/M2 R1/R2 M3 R3 MB RB G S3 230 ø 60/100 820 70 70 280 70 268 M R C MB RB S3 230 103 600 119 600 103 Hydraulic connections M Zone 1 system flow HIGH G 3/4 R Zone 1 system return HIGH G 3/4 M1 Zone 2 system flow HIGH* G 3/4 R1 Zone 2 system return HIGH* G 3/4 M2 Zone 2 system flow LOW* G 3/4 R2 Zone 2 system return LOW* G 3/4 M3 Zone 3 system flow HIGH* G 3/4 303 R3 Zone 3 system return LOW* G 3/4 MB D.H.W. storage tank flow G 3/4 RB D.H.W. storage tank return G 3/4 G Gas supply G 3/4 C System filling G 3/4 S3 Condensate drain ø 25 * with optional kits 16

vers. HM 30/50 40 70 55 55 55 55 173 36 741 R M C E U G S3 ø 60/100 89 820 Hydraulic connections M Zone 1 system delivery HIGH G 3/4 R Zone 1 system return HIGH G 3/4 E D.H.W. inlet G 1/2 U D.H.W. outlet G 1/2 G Gas supply G 3/4 C Recirculation G 1/2 S3 Condensate drain ø 25 50 173 70 70 70 70 70 70 150 85 55 M R M1/M2 R1/R2 M3 R3 G C U E S3 ø 60/100 764 89 1535 MBS 310 RBS 179 230 103 600 700 vers. HM 30/110 103 Hydraulic connections M Zone 1 system delivery HIGH G 3/4 R Zone 1 system return HIGH G 3/4 M1 Zone 2 system delivery HIGH* G 3/4 R1 Zone 2 system return HIGH* G 3/4 M2 Zone 2 system delivery LOW* G 3/4 R2 Zone 2 system return LOW* G 3/4 M3 Zone 3 system delivery HIGH* G 3/4 R3 Zone 3 system return LOW* G 3/4 E D.H.W. inlet G 3/4 U D.H.W. outlet G 3/4 G Gas supply G 3/4 945 * with optional kits 122 600 600 vers. HM 30/300 COLLEGAMENTI ELETTRICI ø 60/100 107 192,5 296,5 180 130 133 350,5 707070707070 60 U C M/M1 R/R1 M2 R2 M3 R3 220 G RS MS E 1726,5 55 SCARICO CONDENSA 900 422 700 17

ø 60 Kombi Solar HE ErP KOMBI SOLAR HE ErP MODEL 30 30 DB Minimum/Nominal heat output 80-60 C kw 5,9/28,9 5,9/28,9 Minimum/Nominal heat output 50-30 C kw 6,6/31,6 6,6/31,6 Minimum/Nominal heat input* kw 6,2/29,5 6,2/29,5 Min/max useful output 80-60 C % 95/98 95/98 Min/max useful output 50-30 C % 107/107 107/107 Useful perform. at 30% of the load (40-30 C) % 107,7 107,7 Heating energy efficiency class A A Domestic hot water energy efficiency class B B Domestic hot water load profile XL XL Heating sound power db (A) 51 51 Absorbed power (Qn max / Qn min) W 86 / 58 86 / 58 Electrical protection class IP X4D X4D Heating setting range C 20 80 20 80 Boiler water content l 206 206 Max operating pressure bar 3 3 Exp. vessel preload capacity and pressure l/bar 12/1 12/1 Solar expansion vessel capacity l 18 18 Solar tank capacity l 200 200 Domestic hot water setting range C 10 65 10 65 Specific hot water flow rate (EN 13203) l/min 17,0 17,0 Continuous hot water flow rate T 30 C l/min 13,6 13,6 Min/max hot water pressure bar 0,2/7,0 0,2/7,0 D.H.W. expansion tank capacity l 4 4 NOx emission class 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) Max horizontal rectilinear length pipe ø 60/100 m 5,0 5,0 Max horizontal rectilinear length pipe ø 80/125 m 10,0 10,0 Max horizontal rectilinear length pipe ø 80+80 m 35 + 35 35 + 35 Max horizontal rectilinear length pipe ø 60+60 m 7 + 7 7 + 7 Boiler net weight kg 180 225 * Thermal power in heating mode is calculated using the Lower Calorific Value (LCV) Overall dimensions 210 600 640 428 279 105 2110 ø 60/100 854 509 1256 85 60 115 M R R1/R2 M1/M2 S3 821 MS RS U E G 63 83 78 76 161,5 138,5 1289 71 Hydraulic connections M Zone 1 system flow 3/4" M1 Zone 2 system flow HIGH 3/4" M2 Zone 2 system flow LOW 3/4" R Zone 1 system return 3/4" R1 Zone 2 system return HIGH 3/4" R2 Zone 2 system return LOW 3/4" G Gas supply 3/4" E D.H.W. inlet 1/2" U D.H.W. outlet 1/2" MS Solar collector flow 1" RS Solar collector return 1" S3 Condensate drain ø 25 97 ø 60 202 531 90 429 ø 80 ø 80 128 CA 107 209 317 CA CS Separate pipes ø 80 CA Intake CS Drain 18

Logo ErP LOGO ErP MODEL 30/50 30/110 Nominal heat output kw 29,8 29,8 Minimum heat output kw 24,4 24,4 Nominal heat input* kw 31,8 31,8 Minimum heat input* kw 26,1 26,1 Rated output % 93,7 93,7 Useful perform. at 30% of the load (40-30 C) % 94 94 Heating energy efficiency class C C Domestic hot water energy efficiency class B B Domestic hot water load profile XL XL Heating sound power db (A) 59 54 Absorbed power (Qn max / Qn min) W 58 / 56 58 / 56 Electrical protection class IP X2D X2D Max operating pressure bar 4 4 Max operating temperature C 85 85 Boiler water content l 23,8 24,0 Elements in cast iron no. 5 5 Heating temperature regulation C 20 80 20 80 Heating expansion tank capacity/pressure l/bar 10/1 10/1 Max boiler operating pressure bar 7 7 Specific hot water flow rate (EN 13203) l/min 17,5 24,8 Continuous hot water flow rate T 30 C lt/hr 864 864 Boiler capacity l 50 110 Time of recovery from 25 to 55 C min. 9 18 15 05 D.H.W. temperature regulation C 10 65 10 65 D.H.W. expansion tank capacity l 2,5 4,0 NOx class 5 ( 70 mg/kwh) 5 ( 70 mg/kwh) Boiler net weight kg 198 226 * Thermal power in heating mode is calculated using the Lower Calorific Value (LCV) Overall dimensions 700 838 41 70 54 55 55 55 172 R M C E U G ø 130 850 742 35 vers. 30/50 600 838 50 180 172 ø130 1566 70 70 70 70 70 220 55 85 763 M R M1/M2 R1/R2 M3 R3 C U E G 1493 Hydraulic connections 30/50 30/110 M Zone 1 system delivery HIGH G 3/4 G 3/4 R Zone 1 system return HIGH G 3/4 G 3/4 M1 Zone 2 system delivery HIGH* G 3/4 R1 Zone 2 system return HIGH* G 3/4 M2 Zone 2 system delivery LOW* G 3/4 R2 Zone 2 system return LOW* G 3/4 E D.H.W. inlet G 1/2 G 3/4 U D.H.W. outlet G 1/2 G 3/4 C Recirculation G 1/2 G 3/4 (*) G Gas supply G 3/4 G 3/4 CA Intake pipe ø 80 CS Drain pipe ø 80 - Coaxial ø 60/100 * with optional kits vers. 30/110 19

Fonderie SIME S.p.A. reserves the right to modify its products in order to improve them without compromising their essential features, at any time and without prior warning. Therefore, this prospectus does not constitute a contract with third parties. cod. 3952507-02.2016 Within the scope of the "20-20-20 Plan", the European Union has passed a number of known directives including: > Energy Related Products (ErP) Directive, which regulates eco-compatible design > Energy Labelling Directive (ELD), which regulates the labelling of devices based on their energy efficiency. ECO-COMPATIBLE DESIGN (ErP) Regulations covering eco-compatible design define the requirements that products must satisfy in order to be commercialised in the European market from 26th September 2015, specifically in regards to minimum heating and domestic hot water efficiency, maximum allowed polluting agents and noise levels. Moreover, from 1st August 2015, domestic hot water boilers can only be operated with high-efficiency circulator pumps. ENERGY LABELLING (ELD) From 26th September 2015, equipment with an output up to 70 kw and domestic hot water boilers with a volume up to 500 litres must carry ENERGY LABELS classifying products according to their level of efficiency, in a scale from A+++ to G. NAME OR BRAND OF SUPPLIER AREA HEATING SECTION HEATING PRODUCTION ENERGY EFFICIENCY CLASS SOUND POWER LEVEL RATED THERMAL POWER BOILER MODEL DOMESTIC HOT WATER LOAD PROFILE D.H.W. PRODUCTION ENERGY EFFICIENCY CLASS DOMESTIC HOT WATER SECTION INDICATION OF POSSIBILITY TO PROGRAMME HOT WATER IN PERIODS OF NON-USE ENERGY LABEL FOR COMBINED HEATING EQUIPMENT Fonderie Sime. S.p.A has obtained voluntary certifications ISO 14001 and OHSAS 18001, constituting international recognition of the commitment and responsibility assumed by Sime on matters of the environment and worker safety. Through the successful achievement of this objective, Sime has materialised its corporate mission, while undertaking to continuously improve its current activities and future processes. Fonderie Sime S.p.A. - Via Garbo, 27-37045 Legnago (VR) Italy - Tel. +39 0442 631111 - Fax +39 0442 631291