Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System

Similar documents
A Review Paper on Extracting Waste Heat from the Engine Exhaust and Reutilizing in Car Air Conditioning

Short Questions with Answers APPLIED THERMODYNAMICS(5 TH MECHANICAL) Chapter No-1

ADVANCES in NATURAL and APPLIED SCIENCES

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

EXPERIMENTAL INVESTIGATION OF VAPOUR ABSORPTION SYSTEM

Design and Performance Analysis of a Car Air Conditioner with LPG as a Refrigerant

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Chapter 10. Refrigeration and Heat Pump Systems

Design - Analysis of Generator of Vapour Absorption Refrigeration System for Automotive Air- Conditioning

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Scientific Journal Impact Factor: (ISRA), Impact Factor: Methodology. [Yadav, 3(9): September, 2014] ISSN:

Design & Fabrication of Hybrid Cooler

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

we will examine only the vapour compression systems transfers to the Carnot cycle can serve as the initial model of the ideal refrigeration cycle.

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Design and development of vapor absorption refrigeration system for rural dwellers. Adekeye, T. Oyedepo, S.O and Oyebanji, J.A

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Carnot. 2. (a) Discuss the advantages of the dense air refrigeration system over an open air refrigeration system?

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

Homework Chapter2. Homework Chapter3

R07. Answer any FIVE Questions All Questions carry equal marks *****

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Design of solar powered vapour absorption refrigeration system

Experimental Investigation on Domestic Refrigerator by Shell and Tube Heat Exchanger after the Condenser Using Sub Colling of Refregaring Fluid

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Performance Assessment of Water Cooled Condenser Refrigeration System

Chapter 9. Refrigeration and Liquefaction

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

η second law = Second law efficiency

Sustainability of Automobile Air- Conditioning System Using Refrigerant R1234yf Instead of R134a

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2013) 2 / 25 T270 COP R = Q L

Design of an Air Cooled Telephone Booth Using Solar Energy as Non-Conventional Energy Source

Refrigeration Cycles. Refrigerators, Air-conditioners & Heat Pumps. Refrigeration Capacity/Performance. Dr. Md. Zahurul Haq

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Design of LPG Refrigeration System

T270 COP R = Q L. c Dr. Md. Zahurul Haq (BUET) Refrigeration Cycles ME 6101 (2017) 2 / 23 T354

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Experimental Investigation of Hot water Fired R134A-DMAC VARS System at Various Heat Source Temperatures

FABRICATION OF SOLAR ENERGY FOR AIR CONDITIONING SYSTEM

System Modeling of Gas Engine Driven Heat Pump

EXPERIMENTAL INVESTIGATION OF HYBRID NANOFLUID ON THERMOSYPHON TYPE WICKLESS HEAT PIPE HEAT EXCHANGER THERMAL PERFORMANCE

Experimental Investigations of Heat Pump for Domestic and Light Commercial Market.

Presentation on HVAC: Heating Ventilation Air Conditioning

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance and Analytical Study of Cooler Cum Air Conditioner based on Vapour Compression Refrigeration System

REVIEW OF DESIGN OF SINGLE EFFECT SOLAR POWERED VAPOUR ABSORPTION AIR CONDITIONING SYSTEM

: REFRIGERATION & AIR CONDITIONING COURSE CODE : 6023 COURSE CATEGORY : A PERIODS/ WEEK : 6 PERIODS/ SEMESTER : 90 CREDIT : 6 TIME SCHEDULE

Chapter 11 REFRIGERATION CYCLES

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

COMPRESSOR LESS SOLAR REFRIGERATOR

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

A Survey on Year Round Air Conditioning System in Cars by using Exhaust Gases

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Modified Air Cooler with Split Cooling Unit

pdfmachine trial version

ISSN Vol.08,Issue.21, November-2016, Pages:

(ME-225) HEATING, VENTILATION AND AIR-CONDITIONING SYSTEM

EXPERIMENTAL INVESTIGATION ON RECOVERY OF WASTE HEAT FROM WINDOW AIR CONDITIONER

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Design and Fabrication of Water Refrigeration System by Creating Vacuum

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Waghmare Tushar Ramrao, D.S.Nakate

REPLACING HARMFUL CFC 12 BY ECO-FRIENDLY REFRIGERANT IN MILK CHILLER

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

Performance Evaluation of Evaporative Air- Conditioning System for Truck Cabins in Indian Environmental Conditions

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

Chapter 11 REFRIGERATION CYCLES

Thermodynamics I. Refrigeration and Heat Pump Cycles

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

Thermodynamics II Chapter 5 Refrigeration

INSTITUTE OF AERONAUTICAL ENGINEERING

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

REFRIGERATION AND AIR CONDITIONING

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Refrigeration and Air Conditioning

Alternative Cooling Processes 1. Classification of Refrigeration Cycles. Agenda. Hans Jonsson

LECTURE-18 Vapour Absorption Refrigeration System

Enhancement of COP in Vapour Compression Refrigeration System

Chapter 11. Refrigeration Cycles. Study Guide in PowerPoint

Transcription:

Evaluation of Available Heat at the Exhaust of Automotive Engine for Air Conditioning by Vapor Absorption System Kautuk Sharma 1, Devendra singh Sikarwar 2 1 Research scholar, Mechanical Engineering Department, PCST, Indore, MP, India 2 Assistant Professor, Mechanical Engineering Department, PCST, Indore, MP, India ABSTRACT This work presents an experimental study of an automobile air conditioning system using aqua-ammonia refrigerant based vapour absorption refrigeration system. This system is using the exhaust waste heat of an internal combustion 4-Stroke petrol engine as an energy source. The availability of energy that can be used in the generator and its effect on engine performance, exhaust emissions, auto air conditioning performance and fuel economy will evaluated This system helps in reducing the consumption of fuel by utilizing the Exhaust waste heat of the system and hence optimizing the efficiency also no CFC refrigerant is used so have very little effect on environment. The exhaust gas heat available at the outlet of exhaust pipe is as high as it can run an air conditioning system of about 1 tonne capacity. Further the main purpose of this research is to utilize the exhaust waste heat to gain the maximum efficiency. Keyword: - Air Conditioning, Vapour Absorption System, Exhaust Gases, COP, Aqua-ammonia, cooling load 1. INTRODUCTION Air conditioning is the cooling of indoor air for thermal comfort. In another sense, the term can refer to any form of cooling, heating, ventilation, or disinfection that modifies the condition of air. An air conditioner is an appliance, system, or machine which is designed to stabilize the air temperature and humidity within an area (used for cooling as well as heating depending on the air properties at a given time), typically by using a refrigeration cycle but sometimes using evaporation, commonly for comfort cooling in buildings and motor vehicles. Vapor Absorption refrigeration system uses heat energy to change the refrigerant state unlike mechanical energy in vapor compression refrigeration system. The main advantage of using Vapor absorption cycle is that, the heat energy required to perform the operation can be extracted from the exhaust of the automobile. There are also many other advantages of vapor absorption system as it contains fewer moving parts thus lowers the noise level, also it required less electrical input to run the displacement pump as compared to compressor in vapor compression system. 3650 www.ijariie.com 330

1.1 Aqua-ammonia Solution Ammonia (R-717) is one of the oldest and most widely used of all the refrigerants. Its greatest application is found in large and commercial reciprocating compression systems where high toxicity is secondary. It is also widely used in absorption systems. It is a chemical compound of nitrogen and hydrogen and under ordinary conditions, it is a colorless gas. Its boiling point at atmospheric pressure is -33.3 C and its melting point from the solid is -78 C. The low boiling point makes it possible to have refrigeration at temperatures considerably below 0 C without using pressures below atmospheric in the evaporator.its latent heat of vaporization at -15 C is 1315 KJ/Kg. Thus, large refrigerating effects are possible with relatively small sized machinery. The condenser pressure at 30 C is 10.78 bar. The condensers for R-717 are usually of water cooled type. In the vapour absorption system ammonia is the refrigerant and water is the absorbent. This is known as the Aquaammonia absorption system. Ammonia vapour is vigorously absorbed in water. So when low pressure ammonia vapour from the evaporator comes in contact in the absorber with the weak solution (the concentration of ammonia in water is low) coming from the generator, it is readily absorbed, releasing the latent heat of condensation 1.2 Working Principle The heat from the Exhaust flue gases is utilized in the generator to heat the strong Aqua-ammonia solution. The refrigerant gets vaporize, separated from water and went through the condenser where it is liquefied. The liquid refrigerant then flows to the evaporator where it is vaporize by extracting the heat from the air. This vapor refrigerant from the evaporator then flows to the absorber where it is absorbed by the weak solution thereby forming a strong solution. This strong solution is then pumped to the generator and thus the cycle is. 2. METHODOLGY There is a working model of three cylinder four stroke engine of MARUTI 800. The entire Test performs on this working model. In this Project Exhaust gas heat is proposed for air conditioning of three cylinder four stroke passenger cars (Maruti 800) by vapour absorption refrigeration system. The exhaust of car is used to heat the ammonia solution in the generator. The temperature of exhaust heat is measured at different Engine Load and different-different. 3650 www.ijariie.com 331

Figure -1: 4-Stroke petrol Engine Test Rig. 2.1 Description Of Engine Engine Model MARUTI 800 Number of cylinder Number of Stroke Length of Stroke Three Four 72 mm Bore Diameter Radius of dynamometer.5m Torque 2.2 Assumptions 66.5 mm 59 N-M at 2500 rpm Table-1 Description of 4-stroke Maruti 800 Car 1) Vehicle in is running condition 2) Fuel consumption is same at fixed for and Torque. 3) Cooling water flow rate is fixed for and Torque. 4) Air flow rate is fixed for and Torque 2.3 Testing Procedure 1) Properly arranged whole Set up of experiment. 2) Connect the Rope brake dynamometer from engine properly 3) Fill the burette with Fuel (Petrol) at accurate level and note down the datum reading. 4) Now rope is stretched until spring balance indicator will shows 5 kg. 5) Now engine is started then Note down the reading of burette which shows the fuel Consumption rate. 6) Take reading of U tube manometer which shows the pressure in mm of water column. 7) Now set the by accelerator. 8) Measure the by tachometer as per requirement and let the engine stabilize. 9) Note down the exhaust gas temperature shows by digital temperature meter. 10) Note down the temperature of air passed from the engine. 3650 www.ijariie.com 332

11) Take the reading of cooling water temperature from digital temperature. 12) Then set rpm at 2000 & take the reading of Exhaust gas, cooling water and air Temperature. 13) Repeat this procedure for 2500 & 3000 rpm also. 14) Then set the spring balance load at 8 Kg for 1500, 2000, 2500 &3000 rpm and take the Readings. 15) Then set the spring balance load at 10 Kg for 1500, 2000, 2500 &3000 rpm and take the Readings. 2.4Observation Table Load (Kg) 5 Temperature of Cooling water ( C) Temperature of Air ( C) Temperature of Exhaust gas ( C) 1500 39.7 23.1 501 2000 40.1 23.7 507 2500 40.7 23.7 513 3000 41.1 24.6 520 1500 41.1 24.2 515 8 2000 41.9 25.2 521 2500 42.2 25.3 527 3000 42.1 25.3 534 1500 41.3 24.5 528 10 2000 41.9 24.8 533 2500 42.1 25.3 541 3000 42.7 26 544 Table-2 Tempeature of Air, Cooling Water and Exhaust gases at Variable speed 3. CALCULATION Pulley Radius (r) =.5 m Fuel flow rate (m) = 8.33 X 10-04 Kg/Sec Cooling water flow rate (m w ) = 0.12 Kg/Sec Air flow rate (m a ) =.23 Kg/ Sec Calorific Value of petrol = 42500 KJ / Kg Total energy in Fuel = 8.33 X 10-04 Kg/Sec X 42,500 KJ /Kg Total energy in Fuel = 35.4 kw Let, Radius of Dynamometer = r Load on Dynamometer = W Torque Produced/ Required = T Revolution per minute = N 3650 www.ijariie.com 333

3.1 Formulae used a) Torque = r W 9.81...Eq(3.1) Where r = Pulley radius W= Load on dynamometer b) Brake Power =...Eq.(3.2) Where N=Revolution of dynamometer wheel per minute T = Torque produced c) Heat Supplied = m C p dt Eq(3.3) Where m = cooling water flow rate in Kg/Sec C p = Specific heat of water/ Ventilation air at constant pressure dt = Change in temperature of cooling water/ Ventilation air Net Energy will be = Total energy in fuel (Break Power + Heat Supplied to cooling water + Heat Supplied to Ventilation air)...eq. (3.4) 3.2 Calculation for 5 Kg Load Table 3.1 Torque (Nm) Break Power Heat Supplied Cooling Water Ventilation air Net Heat Supplied 1500 3.85 7.51 1.87 22.1 24.525 2000 5.20 7.57 2.01 20.63 2500 6.42 7.84 2.01 19.15 3.3 Calculation for 8Kg Load 3000 7.71 8.12 2.1 17.5 Table-3 Calculation of Neat heat supplied and varying for 5 Kg Load Table 3.2 Torque (Nm) Break Power Heat Supplied Cooling Water Ventilation Air Net Heat Supplied 1500 6.16 8.07 2.12 19.06 39.24 2000 8.22 8.46 2.26 16.47 2500 10.27 8.86 2.23 13.903 3650 www.ijariie.com 334

3000 12.33 8.57 2.3 12.22 3.4 Calculation for 10Kg Load Table 3.3 Torque (Nm) Break Power Cooling Water Heat Supplied Ventilation Air Net Heat Supplied 1500 7.70 8.2 2.18 17.61 49.05 2000 10.27 8.51 2.26 14.35 2500 12.84 8.57 2.3 11.62 3000 15.42 8.87 2.52 8.62 3.5 Cooling Load estimation Let assume Average Solar radiation in middle India is 700 W/m 2 Consider Area of Roof is = 1.5 X 1 = 1.5 m 2 = 700 / 1.5 = 1050 Watt = 1.05 KW Table 3.5 Cooling Load Solar heat lose through Roof area Solar heat loss through Glass area Heat Lose due to Occupants Heat lose due to other (infiltration, Air leakage) Total Amount of Heat (KW) 1.05 KW.53 KW 1.5 KW 1 KW 4 KW 3650 www.ijariie.com 335

4. RESULT By Subtracting Losses from the Net energy, we will get the following results. Load (Kg) 5 Table 4.1 Before consider Losses(KW) After consider Losses(KW) 1500 22.21 18.21 2000 20.63 16.63 2500 19.15 15.15 3000 17.5 13.5 1500 19.06 15.06 8 2000 16.47 12.47 2500 13.903 9.903 3000 12.22 8.22 1500 17.61 13.61 10 2000 14.35 10.35 2500 11.62 7.62 3000 8.62 4.62 5. CONCLUSIONS We can see very easily 4.62 KW heat is minimally available at maximum load. It shows that 1 tonne refrigeration system can be installed. It will require only installation cost after that there will be no any type of expenditure for the running of Vapour absorption refrigeration system. It is eco-friendly also 6. REFERENCES [1]. Khaled S. AlQdah [1] Performance and Evaluation of Aqua Ammonia Auto Air Conditioner System Using Exhaust Waste Energy Tafila Technical University, Zip code: 66110, Tafila, Jordan. [2]. Isaac Mathew Pavoodath [2] Absorption AC in Vehicles Using Exhaust Gas International Conference on Automation, Control and Robotics (ICACR'2012) December 21-22, 2012 Bangkok (Thailand). [3]. Dürnholz, M., Eifler, G., and Endres, H [3]., "Exhaust-Gas Recirculation - A Measure to Reduce Exhaust Emissions of DI Diesel Engines," SAE Technical Paper 920725, 1992, doi:10.4271/920725 3650 www.ijariie.com 336

[4]. Arias, D., Shedd, T., and Jester, R., [4] "Theoretical Analysis of Waste Heat Recovery from an Internal Combustion Engine in a Hybrid Vehicle," SAE Technical Paper 2006-01-1605, 2006, doi:10.4271/2006-01-1605 [5]. R.Farrington & J.Rugh [5] Impact of vehical Air-condition on fuel economy, Tailpipe emission and electric vehicle range National Renewable Energy Laboratory (NREL) 1617 Cole Blvd. Golden, CO 80401 U.S.A [6]. S.S Mathapati, Mudit Gupta, Sagar Dalimkar [6] A study on automobile air- conditioning based on absorption Refrigeration system using exhaust heat of a vehicle. Singhad Institute of Technology, Lonavala, Maharashtra. [7]. Sachin Kaushik, Dr.S.Singh [7] Thermodynamic Analysis of Vapor Absorption Refrigeration System and Calculation of COP Bipin Tripathi Institute of Technology,Dwarahat, Almora, Uttarakhand (India) 263653 [8]. Text book Refrigeration and Air Conditioning by C.P Arora, R.S Khurmi And J K Gupta [8]. 3650 www.ijariie.com 337