Electromagnetic Locking Devices

Similar documents
Hardware for Sliding Doors & Folding Doors

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Panic and Emergency Exit Devices

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Controlled Door Closing Devices

Mechanically operated locks and locking plates

best practice guide BS EN 14846: 2008 Electromechanically operated locks & striking plates to in association with

Electromagnetic Locking Devices Performance Requirements

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Best practice guide. Electrically powered hold-open devices to BS EN in association with. Association of Building Hardware Manufacturers

Specifying Security Hardware for Doors

dhf General Information Automated Gates Guidance for enforcement bodies

Guide to interpreting Markings for Single Axis Fire Doors Hinges

GUIDELINIE ECB S R10. March European Certification Body GmbH

Guide to gate safety legislation and standards

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

SELF PRESERVATION SOCIETY By Jim Creak

Technical Bulletin CE marking: from 1st July 2013

For more information on Abloy UK visit EXIT HARDWARE

SKG-IKOB Certificatie B.V. Trading under the names SKG, IKOB-BKB and SKW Certificatie

Eligibility criteria

Code of Practice: Hardware for Fire and Escape Doors

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

HD72 Euro Profile Mortice Lockcase. The high performance lock that goes beyond the standard. ASSA ABLOY, the global leader in door opening solutions

Market Introduction DORMA. Modular Panic Hardware System PHA 2000 / PHB 3000

Technical standards to support the evolution of technology enabled care services

Technical reference Reference & design

Confused by standards Standards for social alarms

Water Heating UK 14 th May 2016

Code of Practice: Hardware for Fire and Escape Doors. Issue No.2 June 2006 THE GUILD OF ARCHITECTURAL IRONMONGERS

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Domestic Garage Doors

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

HazLoc Essential Guides:

INTERNATIONAL STANDARD

PANIC EXIT HARDWARE DX-500 Serie

DHF Introduction DHF 2

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Fact File 69 Fire Detection & Alarms

A GUIDE FOR SELECTING FLAT ENTRANCE DOORSETS. A publication for housing associations, landlords, building owners and local authorities in England

White Paper. Effective and Energy Efficient Access Control in Commercial Buildings. The global leader in door opening solutions

Introduction. Declaration of performance (DoP) CE marking

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

RIBA response to the second phase of the Independent Review of Building Regulations and Fire Safety

F O C U S D O O R C L O S E R S

YOUR GUIDE TO UNDERSTANDING CPR

Guidance Note No 19/1. CE Marking windows and doorsets

Type 5 Certifications:

INTERNATIONAL STANDARD

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

INTERNATIONAL STANDARD

Panic & Emergency Exit Hardware

Panic & emergency exit devices

INTERNATIONAL STANDARD

TECHNICAL SPECIFICATION

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Loss Prevention Standard

Sliding Gates White Paper 1 Sliding Gate Safety Third Edition

Standards and third party certification

Overhead Line Insulators

Meeting the requirements of the Equality Act & Fire regulations. Which Door Control?

CERTIFICATION SAFETY & BEYOND

ISO INTERNATIONAL STANDARD. Safety identification Escape and evacuation plan signs. Identification de sécurité Plans d'évacuation et de secours

The Macro Quallty Assurance System for Fire Safety Engineering

Third Party Certification:

asphalt applications European Asphalt Standards and their application in the UK mpa asphalt Asphalt Information Service Mineral Products Association

Conformity assessment procedures for the Alarm Components Scheme

Updated to. include Declaration of Performance Certificates WHICH DOOR CONTROL? Meeting the requirements of the Equality Act & Fire regulations

Loss Prevention Standard

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

ISO Clean Version of Revised Working Draft (N 348)

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

This document is a preview generated by EVS

High Security Locking. Product Catalogue

INTERNATIONAL STANDARD

Guide to Membership Assessments

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

Australian Standard. Emergency escape lighting and exit signs for buildings. Part 1: System design, installation and operation AS 2293.

INTERNATIONAL STANDARD

A Gateway to Safety The New Powered Gates Certification Scheme

Evolution in Emergency Lighting 7 March 2018

FIRE SAFETY POLICY June 2014

ELECTRIC LOCKS. Europrofile range

Pump Shower Drainage Solutions

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Operating Instructions!

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

INTERNATIONAL STANDARD

The Association for Specialist Fire Protection

A guide to the changes of Amendment 1 of BS

ISO INTERNATIONAL STANDARD. Fire detection and alarm systems Part 3: Audible alarm devices

BSI Kitemark the business case

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

CONSUMER INTERESTS IN POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR VACUUM CLEANERS

Value Paper Authors: Stuart Nunns CEng, BSc, FIET, FInstMC. Compliance to IEC means more than just Pfd!

Transcription:

Electromagnetic Locking Devices to DHF TS 010:2016 www.dhfonline.org.uk

01 dhf Best Practice

dhf Best Practice : Electromagnetic Locking Devices to DHF TS 010:2016 dhf Best Practice s This publication is one in a series of guides addressing the major issues that should be considered when specifying, ordering or using the products it describes. It aims to provide the reader with a concise document which includes a summary of relevant sections from the new Technical product standard. The reader will then be in a position to seek further specialist advice where necessary and recognise GENUINE conformity to the new standard. NOTE: Unless stated otherwise, references in this document to DHF TS 010 refer to DHF TS 010:2016. Information in this guide is correct at time of publication and intended for guidance only. Information may since have changed and readers should consult the appropriate specification and authorities to confirm its veracity. TS 010: 2016 Electromagnetic Locking Devices The purpose of this Best Practice to Technical Specification DHF TS 010:2016 is to provide a classification for Electromagnetic Locking Devices, as no current product standard is available and to give specifiers guidance of the performance of these types of products, including internal face fixed, internal mortice, internal shear magnets and external magnets. Scope This performance specification gives the requirements and test methods for the security, durability, fire and environmental for Electromagnetic locking devices, when used on a hinged, pivoted or sliding internal, external doors or gates. Classification DHF TS 010:2016 classify Electromagnetic Locking Devices by using an 8-digit coding system as many European Standards use a similar coding method, for instance a common level of corrosion resistance, category of use, etc. Each digit refers to a particular feature of the product measured against the standard s performance requirements. dhf recommends the use of graphic icons to enhance clarity of information and has devised a system to facilitate assimilation of the various product classifications. Each feature within the product classification is represented by an icon comprising four elements; Symbol, Grade/Type, Range/Options and Box:- The main purpose of the test is to prove the performance of the product when it is tested and passes to this specification. In addition to the requirements of Technical Specification TS 010, if additional fire characteristics are needed then these shall be performed to EN 1634-1 or EN 1634-2. It is expected that the product to be tested have been EMC tested for low voltage devices to EN 61000. This performance specification does not cover those locks and strikes that are covered by EN 14846 electromechanically operated locks and striking plates or products covered by EN 13637 Electromechanical exit systems. The icon above is for a product which meets Grade 8 in the Durability classification where TS 010:2016 stipulates a range of four possible grades. Full details on the dhf graphic icons system is available upon request. The Technical Standard does not cover the requirements for use on panic or emergency escape doors as this is covered by reference to EN 13637. dhf Best Practice 02

Digit 1 Category of use Only one category is identified. Grade 3: high frequency of use by public and others with little incentive to exercise care and with a chance of misuse to the door, i.e. public areas, commercial buildings etc. Digit 2 Durability Four categories of durability are defined and testing will be with the correct fixings and without Z and L brackets. Grade 5: 50,000 cycles Grade 6: 100,000 cycles Grade 7: 200,000 cycles Grade 8: 500,000 cycles Digit 3 Suitable for use on fire / smoke doors Three categories of fire door resistance are identified: Grade 0: not approved for use on fire/smoke door assemblies Grade A: suitable for use on smoke door assemblies only Grade B: suitable for use on smoke / fire door assemblies The Electromagnet shall be included in a full-scale fire test to EN 1634-1 or assessment by a certified body. Digit 6 Security - Holding Force without brackets Six grades of holding force are identified which are in line with other Codes of Practice for Access Control Systems. Each grade is a minimum figure for requirements relating to the holding force required to pull the magnet and armature plate apart. Z&L Brackets are not tested with the Electromagnetic lock as these are known to reduce the holding force. The Electromagnetic locks are also tested with the lowest nominal rated voltage. Grade 1: holding force above 1kN (225 lbf) Grade 2: holding force above 2kN (450 lbf) Grade 3: holding force above 3kN (675 lbf) Grade 4: holding force above 5kN (1125 lbf) Grade 5: holding force above 7kN (1570 lbf) Grade 6: holding force above 10kN (2250 lbf) Digit 7 Security - Electrical Function Three grades are identified for signifying if the product has a means of indication that it is energised or non-energised. There is no pass or fail criteria. Grade 0: no status indicated Grade 1: audio or visual of the element Digit 4 Safety Bolts and Straps Four categories are identified and declared by the manufacturer: Grade 0: not supplied Grade 1: safety bolts supplied Grade 2: straps supplied Grade 3: safety bolts and straps supplied Safety bolts and straps shall be declared by the supplier of the Electromagnetic lock as these are a safety feature Digit 5 Corrosion resistance Grade 2: audio or visual of the element with additional output signal Digit 8 Type of Device Four types of devices are identified which are defined by the manufacturer: Grade A: Internal face to face fixed electromagnetic locks Grade B: Internal mortice face to face fixed electromagnetic locks, which could be fitted in a housing or frame Grade C: Internal electromagnetic shear locks Grade D: External electromagnetic external locks Four grades of corrosion resistance are identified performed to EN 1670. The Electromagnetic lock is charged to secure the armature plate for the duration of the test and the wiring is protected from the salt spray. Grade 1: Up to 24 hours - mild resistance Grade 2: Up to 48 hours - moderate resistance Grade 3: Up to 96 hours - high resistance Grade 4: Up to 240 hours - very high resistance 03 dhf Best Practice

EXAMPLE The following marking denotes an Electromagnetic Face to Face Fixed Lock having achieved to 500 000 operations, suitable for use on a fire door with a very high corrosion resistance fitted with safety bolts and straps and with an indication when energised. Quality assurance The internationally recognised standard for quality assurance, BS EN ISO 9000 provides confidence that the products are being manufactured to a consistent quality level. Companies displaying this symbol are registered under the BSI Registered Firm Scheme. 8 B 3 4 4 1 A (5-8) (0-8) (0-3) (1-4) (1-6) (0-1) (A-D) Marking (a) Manufacturer s name or trademark or other means of positive identification (b) Classification as detailed (c) The number of the Technical Standard (d) The month and year of final assembly by the manufacturer NOTE: This information can be in coded form. Items (b) and (c) should be clearly visible after installation if possible. Support service The correct installation of Electromagnetic Locking devices is essential to ensure that they are able to operate efficiently within the performance levels described in this Technical Standard. Specialist advice is available from dhf members in support of their products from specification stages through supply to effective operation on site. Conformity Conformity to the standard must be clearly and unequivocally stated. Such phrases as tested to..., designed to conform to..., approved to..., are not sufficient. To avoid misleading or confusing claims it is recommended that one of the following phrases is used when stating conformity: dhf dhf (Door and Hardware Federation) was created by a merger between the Association of Building Hardware Manufacturers (ABHM) and the Door and Shutter Manufacturers Association (DSMA), both of which have established excellent reputations in their respective industries, particularly in the area of technical expertise and the development of performance standards in national and international arenas. dhf aims to build on these reputations by exploiting the synergies that exist between the two associations and combining their technical and financial resources to provide a unified, authoritative voice for the entire industry. dhf and its members have consistently risen to the challenges posed by an ever-changing market, creating products which meet the needs of a changing world and developing performance standards alongside national and international organisations, such as BSI and CEN, which enable the industry to select and compare products with confidence. The federation now represents the interests of manufacturers and installers of industrial, pedestrian and garage doors as well as manufacturers of locks and building hardware. It provides professionals in all sectors of the building industry with a single source for technical expertise and creates a more powerful and representative lobbying force, with the ultimate aim of assuring progress and maintaining standards throughout the industry. a) This product has been successfully type-tested for conformity to all of the requirements of TS 010:2016. Test reports and/or certificates are available upon request. b) This product has been successfully type-tested for conformity to all of the requirements of TS 010:2016 including the additional requirements for fire/smoke door use*. Test reports and/or certificates are available upon request. c) This product has been successfully type-tested for conformity to all of the requirements of TS 010:2016 including the additional requirements for fire/smoke door use*. Regular audit testing is undertaken. Test reports and/or certificates. *Add as appropriate. dhf Best Practice 04

05 dhf Best Practice

Contact us for more information Email: info@dhfonline.org.uk Telephone: (0)1827 52337 Address: dhf 42 Heath Street, Tamworth, Staffordshire B79 7JH Copyright dhf (Door & Hardware Federation) 2017 No part of this publication may be reproduced in any form without prior permission in writing from dhf. E&OE dhf 1131/v1/06:17 www.dhfonline.org.uk