Available online at ScienceDirect

Similar documents
A Numerical study of the Fire-extinguishing Performance of Water Mist in an Opening Machinery Space

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

The Experimental Study and Simplified Model of. Water Mist Absorbing Heat Radiation

Simulation of Full-scale Smoke Control in Atrium

Performance-based Fire Design of Air-supported Membrane Coal Storage Shed

Design of Humidity Monitoring System Based on Virtual Instrument

Full-scale Experiment of Longitudinal Ventilation Smoke Control System and Central Smoke Exhaust System in City Underwater Tunnel

EXPERIMENTAL STUDY ON EXTINCTION OF A POOL FIRE WITH WATER MIST

Available online at ScienceDirect. Procedia Engineering 84 (2014 )

A study of Transient Performance of A Cascade Heat Pump System

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

Study of Numerical Analysis on Smoke Exhaust Performance of Portable Smoke Exhaust Fan

Research on Mobile Water Spray Device Reducing the Temperature of Metro Fire

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Suppression Effect of Water Vapor on Flammability Limits of Hydrocarbon Fuels - A Study on Fire Suppression by Water Mist -

2012 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model for oil pan fire

Analysis of the influence of open door size on fire smoke diffusion law in protective engineering

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

2012 International Symposium on Safety Science and Technology Factor analysis of high-rise building fires reasons and fire protection measures

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

Heat transfer enhancement in an air process heater using semi-circular hollow baffles

Simulation of Evacuation Process in a Supermarket with Cellular Automata

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

Experimental Study on the Interaction of Water Mists with Fires in the Confined Space

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Experimental Study on Performance of Double pipe Length on Instantaneous Air Source Heat Pump Water Heater. Yin Shaoyou 1, a

ScienceDirect. Development progress of critical equipment in the CSNS cryogenic hydrogen system

EXPERIMENTAL STUDIES ON THE EFFECT OF THE FIRE POSITION ON PLUME ENTRAINMENT IN A LARGE SPACE

Experimental Research of Air Source Heat Pump Frosting and Defrosting in a. Double Stage-Coupling Heat Pump

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Experimental Study of Initial Process of Frost on Heat Exchanger Surface of Refrigerated Transport Vehicle

Available online at ScienceDirect. Energy Procedia 91 (2016 ) 35 41

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

An experimental study of the impact of tunnel suppression on tunnel ventilation

The study of sewage sludge thermo-drying efficiency

Induction heating with the ring effect for injection molding plates

Procedia - Social and Behavioral Sciences 195 ( 2015 ) World Conference on Technology, Innovation and Entrepreneurship

Shalaby Institute of Fire Protection Heyrothsberge, Germany.

INDOOR HUMAN THERMAL COMFORT OPTIMAL CONTROL WITH DESICCANT WHEEL COOLING SYSTEM

The Effect of Quantity of Salt on the Drying Characteristics of Fresh Noodles

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Construction of Wireless Fire Alarm System Based on ZigBee Technology

1st City Issues Tongji International Symposium City & Real Estate Risk Management 2010

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Experimental study of a novel dew point indirect evaporative cooler

The Mode of Urban Renewal Base on the Smart City Theory under the Background of New Urbanization

European Ethylene Producers Conference (EEPC) October 24-26, 2012 Flame Interaction and Rollover Solutions in Ethylene Cracking Furnaces

Effect of Inclination Angle in Heat Pipe Performance Using Copper Nanofluid

中国科技论文在线 Energy Conversion and Management 52 (2011)

The empirical research on the consumers' willingness to participate in E-waste recycling with a points reward system

Experimental Room Fire Studies with Perforated Suspended Ceiling

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

The Science Behind Water Mist Protection of Typical Building Hazards

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

7th International Conference on Performance-based Fire and Fire Protection Engineering (ICPFFPE 2015)

LONGITUDINAL VENTILATION FOR SMOKE CONTROL IN A TILTED TUNNEL BY SCALE MODELING

Experimental Study of Direct Contact Condensation of Steam on Water Droplets

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Development of Bionic Air Cooler Used in High Temperature Coal Mine

Structure Improvement and Flow Field Analysis of Condenser in Freeze drying Equipment

Fire Test Evaluation using the Kerosene and Aviation Fuel

Shuzo Murakami, Shinsuke Kato, and Taeyeon Kim Institute of Industrial Science, University of Tokyo Tokyo, Japan

CFD Analysis of Fire Characteristics on Subway Junction Station

(ICPFFPE 2013) 2013 International Conference on Performance-based Fire and Fire Protection Engineering. Wuhan, China 16 November 2013

WATER MIST CONVENTION AND EXHIBITION

Hot Air-Microwave Combined Drying Characteristics of Gypsum Board. Won-Pyo Chun, Sung-Il Kim, and Ki-Woo Lee 1

Study on Intelligent Fire Fighting System for Large External Floating-roof Tank

Sprinklers Modeling for Tunnel Road Fire Fighting

The Low-Temperature Radiant Floor Heating System Design and Experimental Study on its Thermal Comfort

Max Fire Box Users Guide

OPTIMIZATION OF VENTILATION MODE OF SMOKE CONTROL SYSTEM IN HIGH-RISE BUILDING FIRE

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

Study on an environmental simulation system of low/high temperature. for great space

Experimental study of hybrid loop heat pipe using pump assistance for high heat flux system

Available online at ScienceDirect. Procedia Engineering 135 (2016 )

Hot Issues in Fire Engineering 28 February 2012

Experimental Study on the Effects of Compression Parameters on Molding Quality of Dried Fish Floss

NUMERICAL STUDIES ON SMOKE SPREAD IN THE CAVITY OF A DOUBLE-SKIN FAÇADE

Optimization of Sensitivity Characteristics of Photoelectric Smoke Detector to Various Smokes

Several Ideas on Fire Detecting Alarm for Power Supply and Distribution System

Available online at ScienceDirect. Synthesis and fire-extinguishing properties of monobromotrifluoropropene

EXPERIMENTAL STUDIES CONCERNING WATER MIST FIRE SUPPRESSION IN VENTILATED CLOSED SPACES

FIRE DYNAMICS IN FAÇADE FIRE TESTS: Measurement, modeling and repeatability

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

Available online at ScienceDirect. New Framework of Intelligent Evacuation System of Buildings

Analysis of Triangle Heating Technique using High Frequency Induction Heating in Forming Process of Steel Plate

American International Journal of Research in Science, Technology, Engineering & Mathematics

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

Static Control in the Plastic Bottling Industry

Research Article. ISSN (Print) , China. *Corresponding author Chen Hao

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

Proceedings Design, Fabrication and Optimization of a Silicon MEMS Natural Gas Sensor

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

Handling Petroleum Products & Static Ignition Hazards Introduction

A Novel Heat Recovery System for High Temperature and High Humidity Gas Qing Hao1, a, Meng Si2, b

Transcription:

Available online at www.sciencedirect.com ScienceDirect Procedia Engineering 71 ( 2014 ) 246 252 Experimental and Mechanism Study of Electrically Charged Water Mist for Controlling Kerosene Fire in a Confined Space Yong-liang Xu a,b, Lan-yun Wang a,b *, Dong-lin Liang a, Ming-gao Yu a, Ting-xiang Chu a a State Key Laboratory Cultivation Base for Gas Geology and Gas Control, Henan Polytechnic University, Jiaozuo 454003, China b State Key Laboratory of Coal Resources and Safe Mining, China University of Mining and Technology, Xuzhou 221116, China Abstract Charged water mist has been widely used in industrial dust controlling due to its charged characteristics. But the study for controlling fire is less. Therefore, in this paper, extinguishing experiments of kerosene fire was carried out with water mist which was charged by a corona discharge in a small-scale and confined space. Water mists with different charge-to-mass ratios was obtained by changing the voltage. The effects on extinguishing time, flame temperature and flame image changes were analyzed. The experiments show that the charged water mist can effectively reduce the extinguishing time, flame temperature and inhibit flame compared with the ordinary water mist. Additionally, the extinguishing efficiency significantly increases with the increase of charge-to-mass ratio. 2014 2014 The Published Authors. by Published Elsevier Ltd. by Elsevier Open access Ltd. under Selection CC BY-NC-ND and peer-review license. under responsibility of the Academic Committee of Peer-review ICPFFPE 2013. under responsibility of School of Engineering of Sun Yat-Sun University. Keywords: corona discharge, charged water mist, charge-to-mass ratio 1. Introduction Water mist extinguishing technique has been widely accepted and has a broad prospect. In recent years, researchers at home and abroad have made a large number of studies on the methods and theories of water mist fire extinguishing [1-3], and made a great progress. By the experiments, Acton etc. [4] found that explosion overpressure was significantly reduced by the use of water mist in the industrial environment of partially closed with geometry similarity and obstacles. But it also shortens the time of reaching the explosion overpressure peak due to the use of water mist. Catlin etc. [5] carried on the experiment of water mist suppressing explosive flame effect in the rectangular steel pipe, the results showed that the flame accelerated in the open pipeline than in the closed environment. The accelerating flame overpressure broke the water mist droplets, thus explosion overpressure decreased. Thomas etc. [6,7]thought that water mist only by evaporation was not enough to extinguish the gas explosion flame., The explosion suppression of water mist depended on the increase of heat transfer and mass transfer as a result of the break of the initial water mist droplets due to the induce flow before the flame front in combustion zone. In China,Lu etc. [8, 9] showed that water mainly broke the chain carrier as the third body or inert droplets to reduce the gas explosion reaction capacity through the balance calculation of explosion reaction and experimental verification. Gu and Wang etc. [10] had studied the explosion suppression of different-concentration methane by the unsusal volume micro-size sprays, and the critical volume of micro-size spray suppressing methane explosion was determined preliminarily. On the applied electric field, M.K. Kim, Eric K. Anderson, Mruthunjaya Uddi, Wookyung Kim, K. Criner M.S. Cha etc. [11-18] found that electric field affected stability and extinguishing of jet fire through changing the electric pulse field * Corresponding author. Tel.: +86-391-3986252; fax: +86-391-3986252. E-mail address: lanyun.wang@gmail.com 1877-7058 2014 Published by Elsevier Ltd. Open access under CC BY-NC-ND license. Peer-review under responsibility of School of Engineering of Sun Yat-Sun University doi: 10.1016/j.proeng.2014.04.035

Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 247 parameters under applied AC or DC field, which showed that the applied electric field had important influence on combustion. The water mist that carries some charges by charging in advance called charged water mist and we realize the specific purpose according to charge species. R. G. Maghirang, X.D. Xiang, R.Yadav etc. [19-21] conducted smoke suppression in smoke diffusion process using charged water mist. The similar research indicated that charged water mist is applied to dust, such as J.McCoy, E. Almuhanna and L.F.Gaunt etc. [22-24] improved the contact ability of water mist and industrial dust by using the charged water mist which is charged in advance so as to achieve the goal of dedusting. Therefore, in this article charged water mists charged by corona charging were used to control a kerosene fire. The mechanisms of flame extinction are analyzed in different forms of charged water mists. 2. The mechanism of water mist corona charged In the real application, the ways of droplets charged are divided into three types, namely the corona charging, induction charging and contact charging. In this article water mists were charged by corona charging. In this case, when charged electrode were applied high voltage direct current (dc),the electrode tip occurred corona discharge, producing a large number of anion-cation near it. Ions which were in contrast to the electrode polarity absorbed by the electrode turned into the neutral, and the ions which had the same polarity with electrodes rejected by the electrode formed ions area around it. Droplets that went through the ions area were charged by ion collisions. Many factors affected the droplets charged, in which the most important were the electric field intensity, particle concentration and relative dielectric constant of medium. 3. The experimental apparatus and methods 3.1. Experimental device In this paper, the experimental device consists of the water mist system, temperature testing system and charged system shown in Fig.1. The charge-to-mass ratio testing system was shown in Fig.2. Fig. 1. The principle diagram of corona charging Fig. 2. The principle diagram of charge-mass ratio test The water mist system is composed of electrical power control board, water tanks, water pumps, steadying pressurepump, valves, pressure gauge, sprinklers etc.. The hollow cone nozzle of 1/2 LNN-4-SS type was used in this experiment. The spray angle is 90 degrees. Temperature testing system involves four thermocouples, temperature acquisition card and computer. Thermocouples denoted by1~4 were respectively placed from the bottom of flame to the top every 10cm. Temperature acquisition system collected a set of data every 4 seconds in this paper. Charged system is composed of high voltage power supply and electrode. As is shown in Fig.1, the electrode was made by welding from a polar ring 60 mm in diameter and 8 polar needles 5mm in diameter. Its inner diameter(r 2 ) was 50mm. The distance between the nozzle and the electrode was 20 mm. 3.2. The testing methods of charge-to-mass ratio The important index of measuring charging performance of droplets is charge-mass ratio. The greater the charge-mass ratio is, the better the charging performance of droplets is. The charging results, the measuring methods of charge-to-mass

248 Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 ratio consist of mesh target method, the simulated target and faraday cage method. Mesh target method was selected for this study, as is shown in Fig.2. The distance between target acquisition barrel and nozzle is 200 mm. When the charged water mist reached wire mesh in target acquisition barrel, the electric charge in the wire mesh conducts to the earth after passing the precise microammeter. Therefore the current can be read in the precise microammeter. Electrically neutral water mist flows to the sampling tube along the barrel wall, then the charge-to-mass ratio can be calculated by measuring time and the quality of water mist. The calculation formula of the charge-mass ratio is Q It I (1) M q t q Q - charge quantities, C; M - quality, kg; I - current, A; T - time, s; q m - mass flow, kg/s. 3.3. The experimental methods Firstly the testing experiments of charge-to-mass ratio were conducted, as shown in Fig.2. The electric quantity of water mist will change by changing the high voltage power supply output voltage to change electric field intensity of corona field. Then different charge-to-mass ratios were calculated by the different currents value and the corresponding output voltage value was recorded. Contrasting experiments had been carried out by selecting 0mC/kg, 0.5mC/kg, 1.0mC/kg, 1.5mC/kg, 2.0mC/kg five charge-to-mass ratio parameters. The nozzle whose location was constant with the location of water mist was moved to the top of confined space for the next stage fire extinguishing tests. Dimension of the confined space is 0.8m 0.8m 1.2m and the inner diameter of oil pan is 140mm. The fuel used was kerosene, 30g kerosene each time was ignited by 5g alcohol ignition. The time of pre-combustion was 60s and the time of free burning was 4min. The nozzle pressure of 0.6Mpa and the flow rate of 0.391L/min were used. 4. Experimental results and analysis 4.1. Analysis of fire extinguishing time In this paper, each experiment was repeated three times under the same conditions and then got an average time of different charge-to-mass ratios water mist for extinguishing kerosene fire. The experimental results are shown in Table 1. Charge-mass ratio of water mist/(mc kg -1 ) Table 1. Extinguishing time of different charge-to-mass ratio of water mist The first time of extinguishing /s m m The second time of extinguishing/s The third time of extinguishing/s average time of extinguishing/s 0 82 83 87 84 0.5 79 82 81 80.7 1.0 77 73 76 75.7 1.5 72 65 71 69.3 2.0 56 66 62 61.3 ` Tab.1 shows that the extinguishing time of charged water mist is shorter than normal water mist. And the greater the charge-to-mass ratio is, the shorter the extinguishing time of charged water mist becomes. This is because the process of fuel combustion produces a large number of free radicals, the producing, disappearing and reproducing, disappearing again of these free radicals which form a chain reaction to maintain the continuation of combustion process until the fuel is burnt out. Free radicals of fuel combustion are electrically charged as a whole, and the amount of positive and negative charges were balanced in the combustion field. Charged water mist is electrically charged, so it can prevent or inhibit the effective combination of free radicals to inhibit flame combustion and accelerate flame extinguishing after approaching the fire. The greater the charge-to-mass ratio of charged water mist is, the stronger the electrostatic interaction will be and the easier to enter the fire and combine effectively with free radicals of the flame, and the stronger inhibition of combustion. So, the fireextinguishing time is shortened, improving the efficiency of fire fighting.

Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 249 4.2. Effects of charged water mist on temperature during combustion The results that effects of charged water mist on temperature during combustion were shown in Figs.3~7. These figures show that charged water mist is more effective to reduce the flame temperature and shorten the time of fire-extinguishing. Due to the gas phase cooling effects of water mist, the vaporization of water mist can absorb part of heat released by the flame. In addition, the water mist can reduce thermal feedback on fuel by decreasing thermal radiation and absorbing part of thermal radiation. Water mist has electrostatic interaction after applied an electric field and charged. It is easier for charged water mist to enter into the fire due to electrostatic force of the positive and negative ions in combustion field and the entrainment of flame. Consequently, there will be more charged water mist entering into the fire. Because charged water mist is better in atomization effect, smaller in water mist particle size, and more uniform in spray effect than normal water mist, it is easier to enter into the fire and evaporate after absorbing heat of flame, further declining the flame temperature. So the cooling effect is further enhanced compared with normal water mist. With the increase of charge-to-mass ratio, charged water mist can enter into the fire and evaporate more easily. The flame temperature is more effectively reduced and the efficiency of fire fighting is improved. Fig. 3. 0 mc/kg temperature curve Fig. 4. 0.5 mc/kg temperature curve Fig. 5. 1.0 mc/kg temperature curve Fig. 6. 1.5 mc/kg temperature curve Fig. 7. 2.0 mc/kg temperature curve 4.3. Effects of charged water mist on combustion flame Effects of charged water mist on combustion flame are shown in Figs.8~12. Figures show that charged water mist is more effective to inhibit combustion flame and more quickly to extinguish the fire compared to normal water mist. With the increase of charge-to-mass ratio, the stronger the inhibition of charged water mist on the combustion flame, the shorter the time of fire extinguishing. Due to the charged water mist can more easily enter into the fire and evaporate, it is more effective to decrease the flame temperature and reduce the concentration of oxygen in the confined space quickly. As a

250 Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 result, effect of oxygen suffocation is stronger. In addition, due to the charged water mist could more effectively evaporate and interact with the entrainment of combustion flame. So the stretch and oscillation of flame were strengthened, combustion flame was weakened to extinguishing more quickly. In addition, due to the charged water mist can neutralize a part of free radicals and weaken the chain reaction to make flame shrunk more quickly, so the flame extinguishing was quickened. The larger charge-to-mass ratio is, the stronger weakening effect is, and therefore the shorter the time of extinguishing is, the more quickly flame will diminish, the higher the efficiency of fire fighting is. Fig. 8. 0 mc/kg changes of flame Fig. 9. 0.5 mc/kg changes of flame Fig. 10. 1.0 mc/kg changes of flame Fig. 11. 1.5 mc/kg changes of flame

Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 251 Fig. 12. 2.0 mc/kg changes of flame 4.4. The mechanism of charged water mist fire suppression The nature of combustion is a redox reaction. Cations and anions from the electron exchange promote the chain reaction of combustion in redox reaction. Since the most compositions of kerosene are hydrocarbons, the free radicals from combustion of kerosene produces are H +, O -, OH -, and the chain reactions are as follows: RH + O 2 H + + 2O + R decomposition of combustible,endothermic reaction O + H + OH 2OH H 2 O + O exothermic reaction The last step is a strong exothermic reaction The heat output is greater than the absorbed heat of fuel decomposition in the first step. The O - and OH - decomposed from the combustible make sustained burning. A large number of free radicals, anions-cations and free electrons are produced due to incomplete combustion and the ionization process in the flame. Because of the charge of water mist, the coulomb force between the anions-cations causes the redistribution of ions in a flame and the chain reaction is weakened due to the mutual attraction of droplets and anions-cations to be neutral in flame and replacing a part of the chain reaction after the charged water mist added. Water mist inhibitting the flame burning spraying has momentum, and ions of droplets repel ions with the same charged polarity in the flame, the flame even more deviated from the direction of the charged water mist. Due to the entrainment effect of the combustion flame, a part of droplets that take the same charged polarity with the flame can enter the fire. The flame moves to the outside by the repulsive force, thereby the stretch and oscillation of flame was strengthened, combustion flame diminishes rapidly and the process of the flame extinguishing was accelerated. Electron plays a strengthening effect on combustion, charged water mist with a strong positive charge had more cations, the reaction rate of flame chemical ion was effectively reduced by the interattraction of cations and electrons combined into a neutral to consume large amounts of electrons in this process. With the increase of charge-to-mass ratio, the particle size of droplets is smaller and entrainment effect is enhanced, thus charged water mist is more likely to enter the fire and to absorb the flame heat to evaporate, further to reduce the flame temperature. The evaporation of droplets can absorb a lot of heat and thus effectively reduce the flame temperature making the production rate decline. With the increase of charge-tomass ratio results in cations increasing in the droplets, electrons are more likely to be neutralized, so that the flame will diminish more quickly and is extinguished more easily because there are not enough electrons to keep flame burning. 5. Conclusions (1)Compared to common water mist, the charged water mist can more quickly extinguish kerosene fire in confined space. With the increase of charge-to-mass ratio, the fire extinguishing speed becomes faster. (2)Due to electrostatic interaction, charged water mist can enter the fire evaporating more easily and flame temperature is lower. With the increase of charge-to-mass ratio, the cooling effect turns more obvious. (3)Water mist being charged is more likely to enter the fire and neutralize a part of the free radicals to weaken the chain reaction. It makes the flame smaller quickly, and quickens the flame extinguishing. With the increase of charge-to-mass ratio, the combustion flame diminishes faster and the time of extinguishing is shorter. Acknowledgment The authors gratefully acknowledge the support of the research fund provided by Henan Province in China(Project Nos. 122300413210 and 12B440004) and the Open Projects of State Key Laboratory of Coal Resources and Safe Mining, China

252 Yong-liang Xu et al. / Procedia Engineering 71 ( 2014 ) 246 252 University of Mining and Technology (Project No. 12KF02). We also wish to thank the reviewers and editors for their professional and constructive comments, which greatly improved this paper. References [1] S.Hostikkaa, K.McGrattan. Numerical modeling of radiative heat transfer in water sprays[j]. Fire Safety Journal, 2006, 41(1):76-86. [2] Jun QIN, Guang-xuan LIAO, Xi-shi WANG, Xiu-mei XU. Study on extinguishing gaseous diffusion flame by water mist[j]. Journal of Combustion Science and Technology, 2003, 9(5):391-396. [3] Ming-gao YU, Qiang HAO, Yu-long DUAN, Xi-ling LI. Experimental Study on Fire Suppression Effectiveness of Water Mist with Cobalt Chloride Additives[J]. Fire Safty Science, 2007,16(2):81-85. [4] Acton M. R, Sutton P, Wichens M. J. Lessons for Cycle Safety Management[C]. Symposium Series No.122, EChe me, Rugby UK, 1990. [5] Keesvan Wingerden, Erian Wilkins. The influence of water sprays on gas explosions. Part1: water spray generated turbulence[j]. Loss Prevention Process Ind, 1985, 8(20): 54 [6] Thomas G.O, Jones A, Edwards D.H. Influence of water sprays on explosion development in fuel-air mixtures[j]. Combust Sci Technology, 1991(80):47. [7] Thomas G.O. On the conditions required for explosion mitigation by water sprays[j]. Institution of Chemical Engineers Trans IchemE, Vol.78, Part B, September 2000. [8] Shou-xiang LU, Jie HE, Chun-hong YU, et al. Mechanism of gas explosion suppression by water[j]. Journal of China Coal Society,1998,23(4):417-421. [9] You-hua QIN, Zhao-wu SHEN, Shou-xiang LU, et al. Experimental study of the effect of water sprays on gas flame propagation. Journal of Safty And Environment, 2001,1(1):27-29. [10] Rui GU, Xi-shi WANG, Hong-li XU. Experimental study on suppression of methane explosion with ultra-fine water mist. FIRE SAFETY SCIENCE, 2010,19(2): 51-59. [11] M.K. Kim, S.K. Ryu, S.H. Won, S.H. Chung. Electric fields effect on liftoff and blowoff of nonpremixed laminar jet flames in a coflow. Combustion and Flame, 157(2010), 17-24. [12] Eric K. Anderson, Antonio P. Carlucci, Arturo De Risi, Dimitrios C. Kyritsis. Synopsis of experimentally determined effects of electrostatic charge on gasoline sprays. Energy Conversion and Management, 48(2007), 2762-2768. [13] S.H. Won, M.S. Cha, C.S. Park, S.H. Chung. Effect of electric fields on reattachment and propagation speed of tribrachial flames in laminar coflow jets[j]. Proceedings of the Combustion Institute, 31(2007) 963 970. [14] S.H. Won, S.K. Ryu, M.K. Kim, M.S. Cha, S.H. Chung. Effect of electric fields on the propagation speed of tribrachial flames in coflow jets[j]. Combustion and Flame, 152(2008) 496 506. [15] Mruthunjaya Uddi, Naibo Jiang, Evgeny Mintusov, Igor V. Adamovich, Walter R. Lempert. Atomic oxygen measurements in air and air/fuel nanosecond pulse discharges by two photon laser induced fluorescence[j]. Proceedings of the Combustion Institute, 32(2009) 929 936. [16] Wookyung Kim, Hyungrok Do, M. Godfrey Mungal, Mark A. Cappelli. Optimal discharge placement in plasma-assisted combustion of a methane jet in cross flow[j]. Combustion and Flame,153(2008) 603 615. [17] K. Criner, A. Cessou, J. Louiche, P. Vervisch. Stabilization of turbulent lifted jet flames assisted by pulsed high voltage discharge[j]. Combustion and Flame, 144 (2006) 422 425. [18] M.S. Cha, S.M. Lee, K.T. Kim, S.H. Chung. Soot suppression by nonthermal plasma in coflow jet diffusion flames using a dielectric barrier discharge[j]. Combustion and Flame, 141(2005) 438 447. [19] R.G. Maghirang, E.B. Razote. Smoke dissipation by solid particles and charged water spray in enclosed spaces,fire Safety J., 44(2009) 668-671. [20] X.D. Xiang, I. Colbeck, Charged water drops and smoke dissipation, Fire Safety J. 28 (1997) 227 232. [21] R. Yadav, R.G. Maghirang, L.E. Erickson, B. Kakumanu, S.G. Castro, Laboratory evaluation of the effectiveness of nanostructured and conventional particles in clearing smoke in confined spaces, Fire Safety J 43 (1) (2008) 36 41. [22] J. McCoy, L. Meicher, Evaluation of charged water sprays for dust control. US Bureau of Mines, Report No. 818, 1983. [23] E. Almuhanna, R.G. Maghirang, J.P. Murphy, L.E. Erickson, Effectiveness of electrostatically-charged water spray in reducing dust concentration in enclosed spaces, Trans. ASABE 51 (1) (2008) 279 286. [24] L. F. Gaunt, J. F. Hughes, N. M. Harrison. Removal of domestic airborne dust particles by naturally charged liquid sprays, Journal of Electrostatics, 58(2003), 159-169.