Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Similar documents
Case Study. Custom Solutions for High Arc Flash Incident Energy and. Interlocked Electrical Enclosures. Overview: iriss.com

White Paper. Reducing Arc Flash Risks with Electrical Maintenance. Safety Devices. Abstract: iriss.com

Reducing Arc Flash Risks with Electrical Maintenance Safety Devices - Part 2

A Powerful Case for Infrared Windows

CAP Series ,,,,, The Clear Choice. CAP Series Features: Who Says Infrared Windows Have to be Round? Certifications:

Predictive Maintenance Training

Are Electrical Switchgear Surveys Still the Low-Hanging Fruit of Infrared Thermography?

NFPA 70B and CSA Z463 Standards for Electrical Maintenance Where Does Airborne Ultrasound Fit In?

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance.

Fluke IR Windows Easier NFPA 70E compliance without compromising on product performance. Fluke-Direct.com

White Paper. OSHA and NFPA 70 Understanding NFPA 70 and its. Implications in Electrical Inspections Abstract: iriss.com

infrared inspections efficient solutions. focused results.

Enhancing Current Maintenance Practices 04. Managing the Risk 06. Constant Monitoring of Electrical Enclosures 08

NFPA 70B and the Importance of Electrical Predictive Maintenance

Common Misconceptions Relating to Infrared Inspection Ports

White Paper. NFPA 70E 2018 Edition Changes and Implications for. Personnel Performing Condition Based Maintenance. Abstract: iriss.

VPFR. cma. Product Brochure. Industrial-Grade Infrared Inspection Viewing Panes

White paper. OSHA and NFPA 70 Safer by Design The History of IRISS. Infrared Windows. Abstract: iriss.com

Thermography Report. For: (Client) at: (location)

Broadening IR applications through using spectral filters

Certification of Thermographers

Infrared Business Tips & Insight

Monitoring of Electrical Equipment Failure Indicators and Alarming

Arc Flash Protection Training - NFPA 70e Electrical Safety

INFRARED WINDOW SERIES

IR Viewing Windows and Arc Ratings Dispelling the myth of Arc-Resistant IR Viewing Windows

Delta T Alert: Wireless Temperature Monitoring of Electrical Enclosures

Coal Pile Fire Monitoring System

Infrared Windows and Arc Ratings: Dispelling the Myth of Arc-Resistant IR Windows

Property risk solutions

Electrical Safety Compliance: NFPA 70E

NFEC FIRE SAFETY SEMINAR Krish Mysore

THERMAL DIAGNOSIS OF MV SWITCHBOARDS: A COST-EFFECTIVE, DEPENDABLE SOLUTION BASED ON AN OPTICAL SENSOR

White Paper. Maintenance Inspection Windows on Transformers. Maintenance Inspection Windows on Transformers. Abstract: iriss.com

A WORLD WITHOUT DOWNTIME

17 TH APRIL 2017 Switch Board Monitoring Protecting Switchboard. Courtesy of ABB. Paul Lee

Surface Acoustic Wave Technology based Temperature Monitoring of High Voltage and High Current Switchgear Boxes

NECA S System Approach to Electrical Safety for NFPA 70E

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

Basic Vehicle Fire Protection Manual

CONTINUOUS MONITORING IS ON THE RISE:

PROTECTING AGAINST ARC FLASH HAZARDS

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Measuring Couch Motion Accuracy with X-ray Beam Fluence

TIAMA recognizing critical defects immediately at the hot-end thanks to the Tiama HOT eye

Utilizing Finite Element Analysis (FEA) for Flexible Heater Designs

USING INFRARED TECHNOLOGY TO DEFINE ENERGY SAVINGS OPPORTUNITIES. James L. Park Energy Conservation Specialist I-Star Energy Solutions

October Airborne & Structure-Borne Ultrasound as a key component to Predictive Maintenance

Emerson s Pervasive Sensing strategies enable plants to realize full potential of Industrial IoT

How to spot and address potential process problems using thermal imaging

COMPLIANCE without compromise SAFETY without sacrifice YOUR RESULTS MATTER

NECA S System Approach to Electrical Safety for NFPA 70E

Using Infrared for Residential Energy Surveys

Development of standards for MV Switchgear for Arc Flash protection. ABB Group May 20, 2013 Slide 1

Guidance on Video Smoke Detection Technology (VSD)

Domestic Infrared Thermography Class 1 Operators Qualification Specification

Black Body Calibration Source User Manual

SAFETY MANUAL. X2200 UV, X9800 IR, X5200 UVIR SIL 2 Certified Flame Detectors

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Pulse Firing Doubles Capacity and Cuts Fuel Costs

Compliance without compromise Safety without sacrifice

SOLAR CELL PRODUCTION REQUIRES EFFECTIVE METROLOGY

Tollgrade Lighthouse Sensor Pilot at CenterPoint Energy. Presented at SWEDE 2011

WHY ELECTRICAL PREVENTIVE MAINTENANCE IS ESSENTIAL TO A SAFE AND PRODUCTIVE WORKPLACE

Performance Based Gas Detection System Design For

Wagner Meters has been an industry leader for over 40 years, creating innovative top-of-theline moisture measurement equipment.

Methane to Markets Oil and Natural Gas Technology Transfer Workshop

SEL Arc-Flash Solutions

APPLICATION NOTE INFRARED SCANNING FOR ENERGY EFFICIENCY

Infrared Inspection Reference Letters Commercial & Residential

Multi-Technology Fault Identification

SEL Arc-Flash Solutions

Continuous, real-time detection, alarming and analysis of partial discharge events

EC100. Thermal Imaging System for Quality Control in Extrusion Processes EC100 PROCESS IMAGING SYSTEM

PD alarm system brings peace of mind in Malta

PIPELINE LEAKAGE DETECTION

CCTV, HOW DOES IT WORK?

Ti Thermal Imaging LTD

An ASSA ABLOY Group brand. ABLOY Safety and Security Systems for Petroleum

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

PGR-8800 TECHNICAL FAQ

Effective Alarm Management for Dynamic and Vessel Control Systems

Why are infrared cameras indispensable for building inspections?

RESNET Infrared Inspection Standard and Certification

Classifying Forced Outages Transmission Maintenance Procedure No. 5

Mining Automation: Sensing Technologies

Developing ambient lighting products for the next generation of vehicles

Maintenance Strategy for High Pressure Piping Systems. by Ewert Snyman

High Temperature InfraRed Thermometer with Laser Pointer

I/R Thermometer Gun 12:1

Products Solutions Services. Energy Solutions. Food & Beverage industry. Slide 2

Oil Burner Controls LMO24... LMO44...

Arc Flash Analysis. Arc flash hazard analysis is required to determine the risk to personnel, warn them of the

PIDS Sensor Installation & Maintenance. 15/03/13/Rev1/PIDS Sensor Installation & Maintenance 1

Changes to NFPA 70E. - The Role of PdM &Safe PdM Work Practices. Tim Rohrer Exiscan LLC

.4 Do complete installation in accordance with latest Electrical Bulletins of the local inspection authority.

Standard for Infrared Inspection of Building Envelopes

NORTH TECHNICAL UNIVERSITY ENGINEERING SCHOOL OF APPLIED SCIENCE. Maintenance Electric Engineering TECHNICAL REPORT

ELECTRICAL/MECHANICAL INFRARED INSPECTION REPORT. The Corporate Facility 2001 Freedom Way United City, USA

Transcription:

A Geothermal Energy Generation Facility Embraces Infrared Polymer Window Inspections By Dominique Capili, Spectrum Scientific Corporation (An IRISS Distributor) Overview: A prominent geothermal energy producer in the Philippines has become a leader through the successful development and operation of numerous energy projects. Since 1983, the company has successfully developed, financed, built and operated seven geothermal steam fields for both wet and dry steam and also owns and operates eleven geothermal power plants. Using the company s expertise, they seek continual improvements to ensure the safe and efficient construction and operation of current and future power plants.

Temperature plays a key role in the everyday maintenance and condition monitoring processes of a power plant. Temperature is the first parameter that is monitored to measure the health of the equipment. Maintenance professionals have been integrating thermography in their maintenance programs to increase efficiency and determine if the equipment is still within the allowable temperatures set by its OEM during operation. For an effective thermographic survey, one must have a direct line of site exposing the surface to be measured. Previously, for an electrical inspection of a 4160-volt metal clad switchgear, the inspector had to remove eight bolts, carefully lift and removed the heavy steel back cover away from the panel and then later inspect it with an infrared camera. This procedure is time consuming, troublesome and most of all, dangerous due to the increased risk of producing an arc flash. Thermography is used in maintenance programs because of three unique characteristics: 1. It can be performed at a safe distance away from the hazards surrounding the equipment without compromising the safety of the plant personnel 2. Two-dimensional inspections enable the visualization of the changes in heat patterns on the surface of the equipment. This assists in the interpretation of what or where a fault may occur. 3. Real-time visualization of thermal patterns helps analyze the equipment in its fully energized state Infrared polymer windows, when mounted on fully energized equipment, allow infrared energy to pass through making thermography inspections safe and in compliance with NFPA/CSA/OSHA or any other local safety regulations. Inspections are completed without equipment shut-down providing real-time data assessments of a facility s critical assets. Installation Over a period of 3 weeks, twenty-seven (27) IRISS Infrared Windows were recently installed with no lost time or accidents. Due to safety concerns, the previous site survey and visual inspection was limited to external surface temperature measurement and visual inspection of panels with the absence of opening any doors or covers. The preliminary installation design was based on shop drawings that determined the quantity, size and specifications of the infrared windows needed. During the scheduled shutdown, actual visual inspections and de-energized opening of panels was conducted to identify and verify which components would be a main priority for the infrared inspections. Several windows sizes and exact locations were changed once the open panel inspections were performed. In total, twenty-two (22) CAP-C-6 and five (5) CAP-C-4 windows were installed on twelve (12) 4.16kV panels and fifteen (15) 13.8kV panels, generators and transformers.

Installation Photos Pre-Installation Step 1: Lay Out Post Installation Step 2: Cutting & Drilling

Step 3: Touchup Painting Equipment Testing Step 4: Mounting The last few days were allocated for bench testing, simulation of readings using multiple OEM IR camera types and training of personnel. The simulation of readings using the various camera types and a Black Body temperature source through the IRISS infrared polymer windows measured distance corrected ambient temperature, emissivity usage values and parameter setting on the respective devices. Bench Testing:

Black Body Simulation: Where possible, connections were taped with known emissivity insulating tape. In this way, more accurate temperature readings can be taken of the target potential hot spots. Emissivity Tape Mounting: As an opaque polymer optic was used on this project, digital photos were taken and laminated and then placed adjacent to the respective inspection window. Target locations for IR inspection were included on the digital image as well as the proper transmission rate for each camera type that might be used by the inspector. In this way, the future IR inspector will have a better idea of what they are looking at with the IR image and it will ensure consistent and accurate temperature data collection methods.

Labelling: Conclusion Since the initial IR Window installation, the program has helped the inspection team decrease the time required to conduct inspections as it does not require a hot work permit and can be done by a single person with no need for special personal protective equipment (PPE). As of publication of this document, they have not found any serious faults but have observed some slight temperature rise on some assets that are being trended and monitored for future change. Plans are being made to expand the use of IR windows on other equipment at this site as well as other power plants owned by the power producer.