Innovation that Endures

Similar documents
ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100(E) Emergency Command Center

ECC-50/100C. Emergency Command Center

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Fire Alarm Control Systems

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

July 14, 1999 DF C-100.

A World of Solutions

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

June 10, 2002 DF C S2424

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

E3 Series Broadband System

D7024 Fire Alarm Control Panel

30.45 Electric Release PDRP-2001

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Agent Release Control Panel

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

AL800ULADA. NAC Power Extender. Installation Guide

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

E3 Series Broadband System

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Pompano Pet Lodge 930 Northwest 31 st Avenue Pompano Beach, FL 33069

Addressable Fire Alarm Control Panel

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

A World of Solutions in Fire Protection Systems

LifeAlarm Fire Alarm Control Panels

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

SP40S-D. Kingfisher Company, inc. Features: Description:

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Fire Alarm Control Systems Simple. Smart. Reliable.

SMALL SCALE SOLUTIONS

FireNET Plus Wiring Instructions

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

MONROE PUBLIC LIBRARY WATERFLOW MONITORING SYSTEM

A World of Solutions

PART IV DETAILED SPECIFICATION

AL600ULADA. NAC Power Extender. Installation Guide

Conventional Releasing Control Panel

Section 4: Operating Instructions

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

PFC-4064 Conventional Fire Alarm Panel

Fire alarm system specification for multiple tenant retail buildings

Invitation to Bid - Bid # 3095

LifeAlarm Fire Alarm Controls

SAFEPATH Mass Notification System (SPMNS)

FireNET Series - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

Specification/ Data Sheet

NETWORK FIRE ALARM CONTROL PANEL. Features

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

Bid Specifications. Fire Alarm Equipment and Parts. USA Bid No

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

INTELLIGENT FIRE ALARM CONTROL UNITS MMX-MNS TM

Laptop / PC Programming Manual

INTELLIGENT FIRE ALARM CONTROL PANEL

Emergency Command Center ECC-50/100 ECC-50/100E. Instruction Manual. Document LS FL-E 5/3/2016 Rev: G P/N LS FL-E:G ECN

good things in small packages

Scott Barrett, President

PSN-1000 & PSN 1000(E) Installation Manual

IFP-2000 F r a en e h n y h t y PH P D

MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC

by Honeywell MS-9050UD(E) FireuTeALarms Fire Alarm Control Panel with DACT NOTIFICATION APPLIANCE CIRCUITS (NACS)

Mircom FX /01/16

Intelligent Single Loop Fire Alarm Control Panel

Fire Alarm Control Panels. MS-5UD Series MS-10UD Series. Manual. Document /24/2012 Rev: C2 P/N 52626:C2 ECN

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

Fire Alarm System Fundamentals

Addressable Fire Alarm Control Panel ES-200X ES-200XC. Manual. Document LS FL-E Rev: C 7/25/2018 ECN:18-323

Fire Alarm Control Panels. MS-5UD Series MS-10UD Series. Manual. Document /7/2014 Rev: C4 P/N 52626:C4 ECN

Desigo TM Fire Safety System A comprehensive fire-protection system

Autonomous control unit

MPC-6000 / MPC-7000 / RND-2

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Smoke Detector Activation of any smoke detector shall start the alarm verification mode.

Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC Manual

ARCHITECT AND ENGINEER SPECIFICATIONS

OJD ITB No Attachment E Duress Alarm Equipment Specifications

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

Manual. Addressable Fire Alarm Control Panel MS-9600LS/MS-9600LSE MS-9600UDLS/MS-9600UDLSE MS-9600LSC

Addressable Fire Alarm Control Panel ES-50X ES-50XC. Manual. Document LS FL-E Rev: A 12/19/2017 ECN:17-570

Data/ Specification Sheet

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX NDS Intelligent Network Fire Alarm Control Unit. Features. Description

A. This Section covers fire alarm systems, including initiating devices, notification appliances, controls, and supervisory devices.

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

109-B Concord Drive Casselberry, FL DynaFire.com INSPECTION AND TESTING FORM PER NFPA 72. Owner s Address: Owner's Phone Number:

Transcription:

Innovation that Endures Fire-Lite on our NEW Emergency Communication Alarms is the first non-proprietary brand to receive UL2572 listing System! www.firelite.com

Suppression Control Panels Fire-Lite s releasing panels are designed to meet the most demanding conventional releasing applications. With the fl exibility and extra high reliability found typically only in advanced systems, the Deluge/Preaction and Agent release models offer a host of features, such as built-in easy-to-use programming templates. MRP-2001 Deluge/Preaction Control Panel 6-zone Style B (Class B) or 6-zone Style D (Class A) with optional modules 4 Programmable Output Circuits Style Y (Class B) or 4 Programmable Output Circuits Style Z (Class A) with optional modules Outputs programmable for Releasing Solenoids Dual hazard operation Adjustable waterfl ow discharge timer and two soak timers Cross-zone capability Pre-programmed and custom application templates Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices Built in programmer: Integral 80 character LCD display with backlighting and keypad Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, remote serial or parallel printer gateway, and LED graphic annunciator 7.0 amps total usable current Annunciators MRP-2002 Agent Release Control Panel 6-zone Style B (Class B) or 6-zone Style D (Class A) with optional modules Four Programmable Output Circuits Style Y (Class B) or Four Programmable Output Circuits Style Z (Class A) with optional modules Outputs programmable for Releasing Solenoids Dual hazard operation Adjustable pre-discharge, discharge and waterfl ow delay timers Programmable Abort operation Cross-zone capability Pre-programmed and custom application templates Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices Built in programmer: Integral 80 character LCD display with backlighting and keypad Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, remote serial or parallel printer gateway, and LED graphic annunciator 7.0 amps total usable current Pull Stations ANN-80 Series The ANN-80 is a compact, backlit, 80-character LCD fi re annunciator that mimics the Fire Alarm Control Panel (FACP) display. It provides system status indicators for AC Power, Alarm, Trouble, Supervisory, and Alarm Silenced conditions. ANN-LED The ANN-LED annunciator module provides LED annunciation of general system faults and input zones/points when used with a compatible Fire Alarm Control Panel. It provides alarm, trouble and supervisory indication for up to 10 input zones or addressable Points. ANN-IO The ANN-I/O is an LED driver module that can be used with a Fire Alarm Control Panel to drive most customized graphic annunciators. It comes in a plastic enclosure that may be mounted inside a custom annunciator or accessory cabinet and can drive up to 40 LEDs. BG-12 BG-12LX BG-12SP BG-12 Series The BG-12 Series is a cost-effective, non-coded series of fi re alarm pull stations. Available in both conventional and addressable versions, including single and dual actions, with either key lock or hex key, these Lexan pull stations are typically specifi ed and desired by most architects and engineers. BG-8 The BG-8, conventional, single action metal fi re alarm pull station for those jurisdictions where metal pull stations are still required.

Conventional Fire Control Panels Fire-Lite s UL 9th Edition listed 24 Volt conventional fi re alarm control panels bring the latest in microprocessor technology to conventional fi re controls and are easy-toinstall, program and operate. With two-zone, four-zone, fi ve-zone and ten-zone confi gurations, these units offer a variety of options to meet most local, state and national requirements. MS-2 Two initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterfl ow One Notifi cation Appliance Circuit (NAC) with built-in horn/strobe synchronization for System Sensor, Wheelock or Gentex with selectable silence 3.0 amps total usable current MS-4 Four initiating zones compatible with 2- and 4-wire smoke detectors, one zone programmable for combo, supervisory and waterfl ow Two NACs with built-in horn/strobe synchronization for System Sensor, Wheelock or Gentex with selectable silence Optional module to convert all four initiating zones and two NACs to Class A Compatible with System Sensor s smoke detectors, providing EZ Walk Test and a Remote Maintenance Signal (panel is offered as i3 Ready, no additional modules needed) 3.0 amps total usable current and expandable to 6.0 amps total with optional second transformer Options include a plug-in 4XTMF transmitter module, a 4XLMF module to support LED annunciators, and a plug-in 4XZMF zone relay module MS-5UD Five-zone Style B (Class B) or Five-zone Style D (Class A) with optional module Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices Integral 80 character LCD display with backlighting and keypad Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators Built-in two-line digital communicator for off premises monitoring Three Form-C programmable relays 3.0 amps total usable current MS-10UD Ten-zone Style B (Class B) or Ten-zone Style D (Class A) with optional module Four NAC Circuits Style Y (Class B) or Four NAC Circuits Style Z (Class A) with optional modules Built-in NAC synchronization for System Sensor, Wheelock, Gentex, Faraday and Amseco devices Built in programmer: Integral 80 character LCD display with backlighting and keypad Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote Annunciator, ANN-S/PG remote serial or parallel printer gateway, ANN-RLY, 10 form C relay board, ANN-LED Zone annunciator and ANN-I/O LED driver board for graphic annunciators Built-in two-line digital communicator for off premises monitoring Three Form-C programmable relays 7.0 amps total shared power Synchronized Power Supplies Known for dependability, Fire-Lite s power supply family, the FCPS-24FS6 and FCPS-24FS8, are recognized as the benchmark for fi re alarm power supplies. Featuring built-in System Sensor, Wheelock, and Gentex strobe synchronization, these UL 9th Edition listed power supplies can be cascaded with strobe timing maintained to meet any installation requirement. FCPS-24FS6/FCPS-24FS8 24 volt, 6 or 8 amp versions available Four Class B (Style Y) Class A (Style Z) outputs Built-in Strobe Synchronization for ADA Compliance Built-in 18 amp Hour Battery Charger Operates as a sync follower or a sync generator (default)

Addressable Fire Alarm Control Panels MS-25, MS-9050UD, MS-9200UDLS and MS-9600LS/MS-9600UDLS Addressability Within Reach Fire-Lite Alarms addressable product offering includes four Fire Alarm control panels that vary in size and capability to meet a wide range of needs, while offering superior value and fl exibility. Our addressable product line offers ease of installation and programming, addressable point identifi cation, built-in digital communication, and NAC synchronization. Our super fast LiteSpeed TM protocol ensures that the safety and security of your building and its occupants are always met with the utmost urgency. Fire-Lite s addressable product line sets the benchmark for Fire protection with its innovative, non-proprietary, cost effective products. Included features on our most popular addressable panels: Ability to connect devices via unshielded fi re wire up to 10,000 feet, allowing for easier retrofi ts and less install time Autoprogram locates and programs the panel for each device and insures correct addressing and device type All electronics mounted on chassis, which can be changed by removing only two nuts, for faster change-outs and easier upgrades Notifi cation appliance circuits have built-in synch for the industry s leading manufacturers including System Sensor, Wheelock and Gentex Compatibility with Fire-Lite s Internet Fire Communicators, for communicating alarms over WAN or LAN to the central station MS-25 Single SLC that provides support for 25 addressable devices (any combination of addressable detectors and modules) SBUS supports two ANN-80 Remote Annunciators JumpStart auto-learn feature reduces installation time and makes programming easy Built-in digital communicator Two programmable Style Y (Class B) notifi cation appliance circuits (NACs) Selectable strobe synchronization for System Sensor, Gentex, Wheelock or AMSECO devices Two programmable Form-C relays and one Form-C trouble relay Uses standard wire (unshielded or twisted pair) Central Station reporting up to fi ve zones MS-9050UD Single SLC that provides support for 50 addressable devices (any combination of addressable detectors and modules) Uses PS-Tools programming utility Integrated DACT for off-premises monitoring Built-in NAC synchronization for System Sensor, Gentex, AND Wheelock devices Annunciator bus supports up to 8 devices, including ANN-80 LCD Remote annunciator, remote serial or parallel printer gateway, and LED graphic annunciator Auto programming feature quickly confi gures detectors and modules Competes with conventional systems, providing addressable point identifi cation at similar price point MS-9200UDLS Single SLC provides support for 198 addressable devices on twisted, unshielded fi re wire Uses PS-Tools programming utility LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard, unshielded wire Built-in digital communicator for off premises monitoring and remote up/download 4 NACs with built-in sync for System Sensor, Gentex, and Wheelock 3 amp total shared power supply expandable to 6 amps of notifi cation power with optional transformer Supports up to 32 optional LCD-80F or ACS LED annunciators MS-9600LS/MS-9600UDLS Up to 159 detectors and 159 control/monitor modules (total of 318 devices) per SLC (636 with SLC-2LS option card) Uses PS-Tools programming utility LiteSpeed protocol for SLC communication polls 10 devices at a time and operates on standard, unshielded wire Autoprogrammable function reduces installation time Advanced Fire Technology includes sensitivity testing and automatic drift compensation 7 amps of power distributed across 4 NAC circuits with onboard Sync Select for System Sensor, Gentex, or Wheelock devices

MS-9200UDLS Fire Alarm Control Panel Applications ECC-50/100 Primary Operator Console ECC-FFT Fire Fighter Telephone SD355 Photo Detector AD355 Adapt Detector H355/H355R/H355T Heat Detector SPSR Series Speaker/Strobe LCD-80F 24VDC Loop SPCW Series Speaker SPR Speaker ECC-50DA/ECC-125DA Distributed Audio Amplifi ers ECC-RM Remote Microphone ECC-RPU Remote Paging Unit ECC-LOC Local Operator Console Innovation that Endures MDF-300 Dual Monitor Module SD355T Photo/Thermal Detector MMF-300 Monitor Module MMF-302 2-Wire Detector Monitor Module ANN-80/ANN-80W Annunciator Power Supply FCPS-24FS6 FCPS-24FS8 D355PL Duct Detector SLC Loop P2R Strobe P2R Strobe P2R Strobe Multi-Modules CRF-300-6 Six-Relay Control Module CMF-300-6 Six-Circuit Supervised Control Module MMF-302-6 Six-Zone Interface Module MMF-300-10 Ten Input Monitor Module Beam 355 Beam Detector CDRM-300 Dual Relay/ Monitor Module Fire-Lite Alarms is recognized as a worldleading manufacturer of innovative, unrestricted, non-proprietary fi re alarm products. Specializing in broad range of applications, Fire-Lite s technologies are proven to install and commission easily while offering superior value at an economical price. Fire-Lite is the perfect solution for a wide range of markets such as schools, churches, malls, healthcare facilities, military facilities, theaters, restaurants, factories, warehouses, and more. Our reputation for manufacturing reliable products with extended longevity insures that you will receive years of trouble free operation and maximum return on investment. www.firelite.com BG-12LX Addressable Manual Pull Station Fire-Lite s continuous commitment to quality, our free training courses and our extended technical support hours guarantee maximum value along with a reliable and trouble-free installation.

Emergency Voice Evacuation/Mass Notification Mass Notifi cation/emergency Communications is about delivering critical messages when they matter most. Our NEW Emergency Command Center (ECC) leverages advanced technology and our 60+ years of life safety dedication and unrestrictive, non-proprietary products. The ECC is ideal for any stand-alone building that needs a fl exible, multi-zoned and highly confi gurable fi re evacuation and mass notifi cation system that s easy to install and maintain. ECC-50/100 Primary Operator Console Seamless integration and control when connected to select Fire-Lite addressable panels through the ANN/ACS communication bus. May be used with any UL-listed Fire Alarm control panels. (Messages can be initiated by using a dry contact or via a Fire Alarm NAC circuit) Includes a single 25V,50 watt speaker circuit. (Upgradable to 100 watts and two speaker circuits with optional amplifi er) Speaker circuits are expandable by up to eight (8) outputs (With an optional ECC-CE6 module) Includes 14 pre-recorded messages that are fi eld programmable for up to 60 seconds of message playback Built in 2 Amp NAC output with sync generator. 8 Command Input Circuits that can be used to activate messages 1 to 8 Optional amplifi er can be confi gured as a backup in the event the primary amplifi er fails. Amplifi ers are independently powered to eliminate system interruption during a short circuit condition. Optional transformer conversion module available for 70.7V speaker operation Supports charging up to 26AH batteries ECC-50DA / ECC-125DA Distributed Audio Amplifiers Externally mounted amplifi ers provide an additional 50 or 125 watts of addressable audio power when connected to the ECC-50/100 Up to eight distributed amplifi ers can be connected to the ECC-50/100 for a total of 1100 watts of audio power Includes four built-in speaker circuits which are expandable to eight circuits with an optional ECC-CE4 module (A maximum of 24 audio circuits) Speaker output voltage is fi eld confi gurable on ECC-50DA for either 25 volts or 70.7 volts of operation Includes a built-in power supply and backup battery charger ECC-RTZM Remote Telephone Zone Module Module allows authorized personal access to the system via any telephone ECC-LOC Local Operator Console Provides a complete control and interface like the ECC-50/100 Includes built in microphone for ALL CALL paging along with message and zone control A maximum of eight ECC-LOCs (or combination of other remote display consoles) ECC-RPU Remote Page Unit Includes built-in microphone for ALL CALL paging along with message control A maximum of eight ECC-RPUs (or combination of other remote display consoles) Additional 9th button can be used to activate an optional monitor module that can be mounted inside the cabinet for applications such as HVAC shutdown ECC-RM Remote Microphone Includes built-in microphone for ALL CALL paging over available speaker zones A maximum of eight ECC-RMs (or combination of other remote display consoles) ECC-FFT Fire Fighter Telephone Provides supervision, annunciation and control for up to 24 remote telephone handsets Built-in auto-program feature for quick installation Full System status LED display Can be wired for class A (Style 6 or Style 7) or class B (Style 4) confi guration Can be confi gured for Multi-Phone Jack Audio Circuit supervision Onboard Form-C system trouble relay Allows simultaneous operation of up to 10 fi refi ghter remote handsets

The Industry s FIRST Upload/Download IP Fire Alarm Communicator FireWatch TM Series of Communicators Fire Panel IPDACT-2UD Router Router Central Station Main Receiver Serial Connections Alarm Server External UD Operator Internet Fire Communicator Introducing FireWatch TM IP Communicator, Fire-Lite s Internet Fire Communicator. Designed to work with later-model Contact ID and DACT-equipped Fire-Lite fi re panels, the IP Communicator sends information over any type of Ethernet network Router connection to a central station equipped with a compatible Teldat VisorALARM IP receiver. The IP Communicator supervises the connection to the central station every 90 seconds, providing faster detection of a connection fault and saves the cost of dedicated redundant phone lines. Router Backup Receiver Maintenance Receiver Remote Monitoring Station No Back-up Phone Lines Required! Serial Connection Alarm Server Compatible to MS-25, MS-9600 and MS-9600LS with DACT-UD, MS-9200UD, MS-9200UDLS, MS-9600UDLS, MS-9050UD, MS-5UD, MS-10UD, and any competitive panel using the 411 series Transmits alarms/events over any IP network: Internet and intranet using customer shared equipment Supports contact ID over IP and does not require static IP address Plugs into Primary phone line on panel DACT UL 864 9th Edition listed to meet NFPA 72 OT (other transmission technologies), packet switched data network, PSDN Telephone Line Communicators 411 Series The Fire-Watch UL 9th Edition listed 411 Series is a compact, slave and Stand-Alone Digital Alarm Communicator Transmitters (DACTs). DACTs are programmable for a variety of fi re, supervisory, trouble, and non-fi re applications. The series consists of the 411, 411UD and 411UDAC products. The 411 provides three supervised monitoring inputs/channels, while the 411UD and 411UDAC provide four inputs/channels. The 411 and 411UD are cost-effective solutions for slave applications that require a control panel to transmit system status to an offsite monitoring facility. The 411UDAC can also provide slave communication, however its primary function is a Stand-Alone Communicator. The 411 and the 411UD can be used with the IP Communicator to monitor the alarm trouble and supervisory relays of any competitive fi re panel. Three models: 411/411UD/411UDAC, slave or Stand-Alone up to 4 input/channels, programmable with PC based upload/download utility PK- 411UD or with on-site programmer PRO-411 Industry-fi rst, UL recognized dialer-runaway prevention feature Complies with FCC long distance Carrier Access Code (CAC) requirements of up to 20-digit telephone numbers Fifteen reporting formats including Contact ID 411UDAC includes an integral power supply/battery charger

Quick Reference Guide Conventional Fire Alarm Control Panels Feature MS-2 MS-4 MS-5UD MS-10UD MS-25 MS-9050UD MS-9200UDLS MS-9600UDLS Panel Voltage 24 24 24 24 24 24 24 24 Addressable Points N/A N/A N/A N/A 25 50 198 636 (2 loops) LiteSpeed TM Protocol N/A N/A N/A N/A N/A No Yes Yes Number of Zones 2 4 5 10 5 20 99 99 Class A or B Initiating Zones B Only B or A option B or A option B or A option B Only A or B A or B A or B Supports System Sensor i3 Yes Yes Yes Yes N/A N/A N/A N/A Detectors with Freeze Warning Notifi cation Circuits 1 2 4 (A or B) 4 (A or B) 2 (B Only) 2 (A or B) 4 (A or B) 4 (A or B) Notifi cation Power (Amps) 3 3.0-6.0 3 7 2.0 2.5 3.0-6.0 7 Communicator 411 Series 411 Series Built-in Built-in Built-in Built-in Built-in Built-in Supports Upload/Download No No Remote or Local Remote or Local Local Remote or Local Remote or Local Remote or Local Works with IP Communicator No No Yes Yes Yes Yes Yes Yes Battery Range (in Amp Hours) 7.0-18 7.0-18 7.0-18 7.0-26 7.0-33 7.0-18 7.0-18 7.0-26 Alarm Contact Yes Yes Programmable Programmable Programmable Programmable Programmable Programmable Trouble Contact Yes Yes Programmable Programmable No Programmable Yes Yes Supervisory Contact No Yes Programmable Programmable Programmable Programmable Programmable Programmable Reverse Polarity Transmitter Option Option Option Option Option Option Option Option Temporal Coding Yes Yes Programmable Programmable Programmable Programmable Programmable Programmable Optional Remote Annunciator No Yes Yes Yes Yes Yes Yes Yes Built-in Sync-Selective Silence Yes Yes Yes Yes Yes Yes Yes Yes Supports Printer No No Option Option No Option Option Yes Listings UL, CSFM UL, CSFM UL, CSFM, UL, CSFM, UL, ULC UL, CSFM, UL, CSFM, ULC, CSFM, MEA MEA MEA, FM MEA, FM CSFM MEA, FM MEA, FM MEA, FM Fire Alarm Panel Communicators Addressable Fire Alarm Control Panels Suppression Control Panels Feature 411 411UD 411UDAC IPDACT-2UD MRP-2001 MRP-2002 Input DC Voltage 12/24 12/24 12 12/24 24 24 Number of Zones/Channels 3 4 4 Addressable 6 6 Class A or B Zones B B B (one A) N/A B or A Option B or A Option Control Communicator Slave Comm. Slave Comm. Stand-Alone or Slave Comm. No No Slave Comm. Contact ID Only Remote Upload/Download No Yes Yes Yes No No No. of Notifi cation Circuits N/A N/A 1 N/A 4 4 Supports System Sensor i3 N/A N/A N/A N/A Yes Yes Detectors with Freeze Warning Notifi cation Power (Amps) N/A N/A 1 N/A 7 7 Battery Range (in Amp Hours) N/A N/A Up to 14.0 N/A 7.0-26 7.0-26 Aux Input No No No Yes N/A N/A Alarm Contact No Option (prog.) Option (prog.) No Programmable Programmable Trouble Contact No Option (prog.) Option (prog.) No Programmable Programmable Supervisory Contact/Output No Option (prog.) Option (prog.) Yes Programmable Programmable Optional Remote Annunciator No No No No Yes Yes Supports Printer No No No No Yes Yes Listings UL, ULC, UL, ULC, UL, ULC, UL, UL, CSFM, UL, CSFM, CSFM, MEA CSFM, MEA CSFM, MEA CSFM MEA, FM MEA, FM One Fire-Lite Place, Northford, CT 06472-1601 USA - Phone: (203) 484-7161 Fax: (203) 484-7118 Canada - Phone: (905) 856-8733 Fax: (905) 856-9687 www.fi relite.com FL-4 8/2013 2013 Honeywell International, Inc. Follow Fire-Lite Alarms on: