NYC Department of Education

Similar documents
NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education

NYC Department of Education Building Condition Assessment Survey :49AM :00PM

NYC Department of Education

SCO # 1 & 2 PUNCLH LIST Project Name: VANCLEAVE UPPER ELEMENTARY CLA#: 13003

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

PLATTEVILLE MIDDLE SCHOOL

Electrical Inspection Special Electrical

Florence High School / Middle School Page 1 of 3 Florence, WI

Electrical Inspection Special Electrical

F. GENERAL REQUIREMENTS Electrical Design Criteria 2006 Edition 4/3/06 School District Palm Beach County Page-1 of 15

GARCIA GALUSKA DESOUSA Consulting Engineers

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

F. GENERAL REQUIREMENTS Electrical Design Criteria 2009 Edition 11/23/2009 School District Palm Beach County Page-1 of 17

Currently, all electrical upgrades would be voluntary, but there are situations in which upgrades would be required.

Transcription:

NYC Department of Education Building Assessment Survey 2017-2018 Asset: P.S. 310 - BRONX, 260 WEST KINGSBRIDGE RD, New York, 10463 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2017-12-07 8:22 AM 2017-12-12 5:06 PM Asset Data Type of Service Does Interactive Whiteboard (IWB) Exist? Water Penetration in Electrical Room? Have any Systems/Major Building Components been upgraded? DEDICATED INTERCOMS IN FIRE RESCUE AREAS Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms in your building? Answer Below Ground Yes Yes Yes Years: 2015 Years: 2009 Years: 2004 Years: 2002 Years: 1995 Years: 1993 Years: 1992 Telephone System, IPDVS/CCTV System, Gymnasium (LED ), LAN Service Switch, Switchboard, Grounding System, Lightning Protection, Fused Disconnect Switch Type Panel Board, Interior Fluorescent, Fire Alarm System (Fused Cutout Panel) Security Lights Public Address System (Amplifier, Tuner) Intrusion Alarm System Emergency Light/Exit Light Panel Fire Alarm System (Electronic Sub-Panel) Most Molded Case Circuit Breaker Panel Board Years: 1990, 1999, 2006, 2016 No Priority Priority Priority Exist Category Last Year? Description Component Affected Location Description Person(s) Notified Person(s) Title Status PhotoImage No Yes Water Leaks onto Electrical Water Penetration in Electrical Room N/A Fixture Room 307 Frank Granieri Custodian Sent to DSF N/A Electrical Electrical Room Frank Granieri Custodian Sent to DSF Inspection Electrical AUDITORIUM House Does a Chandelier exist? No Fixture - Fluorescent PB/A&W Page 1 of 15

Building Assessment Survey 2017-2018 AUDITORIUM House Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Local Sound System Installation Year 1980 5 - Poor AMPLIFIER NOT OPERATIONAL Quantity 1 REPLACE SYSTEM Photo1 Projection System Theater System Dimming System Theater LIGHTING FIXTURE BEYOND USEFUL LIFE Quantity 28 REPLACE-UPGRADE Urgency of Action PRIORITY 1 Photo1 CAFETERIA PB/A&W Page 2 of 15

Building Assessment Survey 2017-2018 CAFETERIA Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Local Sound System Installation Year 1980 5 - Poor AMPLIFIER NOT OPERATIONAL Quantity 1 REPLACE SYSTEM Photo1 Projection System Theater System CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Does a Chandelier exist? Fixture - Fluorescent Fixture - HID Fixture - Incandescent No PB/A&W Page 3 of 15

Building Assessment Survey 2017-2018 CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Fixture - LED COMPUTER LAB Power Panel Yes Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles GYMNASIUM Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED PB/A&W Page 4 of 15

Building Assessment Survey 2017-2018 GYMNASIUM Fixture - LED 1 - Good Local Sound System Installation Year 1980 5 - Poor AMPLIFIER NOT OPERATIONAL Quantity 1 REPLACE SYSTEM Photo1 Projection System Scoreboard Theater System KITCHEN Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED PB/A&W Page 5 of 15

KITCHEN Fixture - LED LIBRARY Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles Projection System LOCKER ROOM MULTIPURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB SCIENCE PREP ROOM SWIMMING POOL TOILET ROOM - STAFF Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED TOILET ROOM - STUDENT Fixture - Fluorescent NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 6 of 15

Building Assessment Survey 2017-2018 TOILET ROOM - STUDENT Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED AUXILIARY SIGNAL/BELL SYSTEM Replacement Quantity 79,000 Replacement Uom EMERGENCY DC STANDBY BATTERY POWER EMERGENCY GENERATOR SET EMERGENCY LIGHT/EXIT LIGHT PANEL PANEL BOARD COVER IS MISSING Location/ Electrical Room Quantity 1 MAINTENANCE Photo1 EMERGENCY LIGHTING Battery Pack Non Battery Pack EXIT LIGHT Battery Pack FIXTURE LAMP NOT OPERATIONAL Location/ Basement Corridor - By Cafeteria Quantity 1 MAINTENANCE Urgency of Action PRIORITY 5 Photo1 Non Battery Pack PB/A&W Page 7 of 15

Building Assessment Survey 2017-2018 EXIT LIGHT Non Battery Pack EXIT/EMERGENCY LIGHT FIXTURE LENS MISSING Location/ Basement Corridor - By Staircase B Quantity 1 INSTALL LENS Urgency of Action PRIORITY 5 Photo1 CITY FIRE ALARM SYSTEM FIRE ALARM SYSTEM Replacement Quantity 79,000 Replacement Uom Bell/Horn Strobe Manual Pull Station Fan Shutdown Control Duct Smoke Detector Area Smoke Detector CO Detector Heat Detector Elevator Recall Magnetic Door Holder/Contactor Fused Cutout Panel Fire Alarm Digital Communicator Main Panel Bell At Panel Fire Alarm Control Panel (Electronic) Fire Alarm Control Panel (Standard) PB/A&W Page 8 of 15

Building Assessment Survey 2017-2018 FIRE ALARM SYSTEM Main Panel Fire Alarm Control Panel (Standard) Manufacturer ACME N/A Capacity/Size Quantity 8 Capacity/Size UOM Circuits Source of Capacity/Size Installation Year 1953 Documented BEYOND USEFUL LIFE Location/ Quantity 79,000 REPLACE Urgency of Action PRIORITY 1 Photo1 Sub-Panel Bell At Panel Fire Alarm Control Panel (Electronic) Manufacturer Pyrotronics Model System 3 Capacity/Size Quantity 6 Capacity/Size UOM Source of Capacity/Size Visual Alarm Panel Zones Installation Year 1992 Quantity 1 PANEL DIRECTION/DIAGRAM IS MISSING MAINTENANCE Photo1 Manufacturer Pyrotronics PB/A&W Page 9 of 15

Building Assessment Survey 2017-2018 FIRE ALARM SYSTEM Sub-Panel Fire Alarm Control Panel (Electronic) Fire Alarm Panel Model System 3 Capacity/Size Quantity 4 Capacity/Size UOM Zones Source of Capacity/Size Installation Year 1992 PANEL DIRECTION/DIAGRAM IS MISSING Quantity 1 MAINTENANCE Photo1 Manufacturer Pyrotronics Model System 3 Capacity/Size Quantity 2 Capacity/Size UOM Source of Capacity/Size Sprinkler Alarm Panel Zones Installation Year 1992 Quantity 1 PANEL DIRECTION/DIAGRAM IS MISSING MAINTENANCE Photo1 Fire Alarm Control Panel (Standard) Manufacturer Capacity/Size Quantity 2 Capacity/Size UOM Source of Capacity/Size ACME N/A Circuits Installation Year 1953 PB/A&W Page 10 of 15

Building Assessment Survey 2017-2018 FIRE ALARM SYSTEM Sub-Panel Fire Alarm Control Panel (Standard) Documented BEYOND USEFUL LIFE Location/ Quantity 79,000 REPLACE Urgency of Action PRIORITY 1 Photo1 Remote Annunciator Sprinkler Flow/Air Pressure Switch Tamper Flow Switch/Chain GROUNDING SYSTEM INTERCOM SYSTEM LAN Local Distribution Frame (I/LDF) Main Rack (MDF) LIGHTNING PROTECTION MOTOR CONTROL CENTER MOTOR STARTER/CONTACTOR PANEL BOARD Fused Disconnect Switch Type Fused Knife Switch Type Fused Toggle Switch Type Molded Case Circuit Breaker Type Location/ Quantity 1 1 - Good 1 - Good PANEL BOARD DIRECTORY MISSING OR REQUIRES UPDATING Basement Corridor - By Room B05 PB/A&W Page 11 of 15

Building Assessment Survey 2017-2018 PANEL BOARD Molded Case Circuit Breaker Type MAINTENANCE Photo1 Location/ Quantity 2 NO SPARE Room 108, Basement Corridor - By Room B20A Urgency of Action PRIORITY 3 Photo1 INSTALL NEW PANEL BOARD PANEL BOARD BEYOND USEFUL LIFE Location/ Corridor - By Rooms 103, 203, 303 Quantity 3 REPLACE-UPGRADE Urgency of Action PRIORITY 1 Photo1 PUBLIC ADDRESS SYSTEM Replacement Quantity 79,000 Replacement Uom Model General Office Installation Year 1980 N/A Location/ Room 204 Quantity 79,000 SPEAKER NOT OPERATIONAL REPLACE Urgency of Action PRIORITY 5 Photo1 Location/ Quantity 79,000 MASTER CLOCK NOT OPERATIONAL General Office PB/A&W Page 12 of 15

Building Assessment Survey 2017-2018 PUBLIC ADDRESS SYSTEM REPLACE Urgency of Action PRIORITY 3 Photo1 SECURITY Location/ BEYOND USEFUL LIFE Quantity 79,000 REPLACE Urgency of Action PRIORITY 1 Photo1 IPDVS/CCTV System Replacement Quantity 79,000 Replacement Uom Installation Year 2015 Intrusion Alarm System Custodial Staff 1 - Good Replacement Quantity 79,000 Replacement Uom Central Control Panel Model Custodian's Office Installation Year 1995 Infrared Sensor Panic Switch Remote Annunciator Siren/Strobe Ultrasonic Sensor - Security Vista - 50P PB/A&W Page 13 of 15

Building Assessment Survey 2017-2018 SECURITY - Security Replacement Quantity 19 Replacement Uom LIGHTING FIXTURE NOT OPERATIONAL Location/ On wall (Exit 6) facing West Kingsbridge Road Quantity 1 REPAIR Purpose of Action LEVEL 3 Photo1 Location/ Quantity 1 LIGHTING FIXTURE BALLAST DEFECTIVE Canopy (Exit 2) facing Heath Avenue REPLACE BALLAST Purpose of Action LEVEL 3 Photo1 SERVICE SWITCH Manufacturer Electrical Room Cutler Hammer Service Switch #1 Capacity/Size Quantity 2,000 Capacity/Size UOM Source of Capacity/Size Amps Installation Year 2009 SWITCHBOARD Number of Spares 2 Air Circuit Breaker Type Fused Disconnect Switch Type Manufacturer Nameplate Documented Electrical Room Capacity/Size Quantity 2,000 Capacity/Size UOM Capacity/Size2 Quantity 2 Cutler Hammer N/A Amps Total PB/A&W Page 14 of 15

SWITCHBOARD Fused Disconnect Switch Type Capacity/Size2 UOM Source of Capacity/Size Installation Year 2009 Fused Knife Switch Type Molded Case Circuit Breaker Type TELEPHONE SYSTEM PBX/Intercom Standard TRANSFORMER TV SYSTEM Cable System Exist? Operational? Main Rack NYC Department of Education Building Assessment Survey 2017-2018 Section(S) Nameplate Documented 1 - Good 1 - Good Yes No PB/A&W Page 15 of 15