Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, KBTU R-410A

Similar documents
Product Data DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, MBTU R-410A

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

Product Data YCZ6036A through 4YCZ6060A Single Packaged Convertible Gas/Electric 16 SEER 3, 4 & 5 Ton, MBTU R-410A

4YCC3048A3096A /3/ /

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

Product Data EN. 4DCY4024 through 4DCY4060 Packaged Convertible Dual Fuel 14 SEER 2-5 Ton, MBTU R-410A

Product Data WCZ6036B through 4WCZ6060B Single Packaged Convertible Heat Pump 16 SEER 3, 4 & 5 Ton R-410A

Product Data. 4WCY4024A through 4WCY4060A Single Packaged Convertible Heat Pump 14 SEER 2-5 Ton R-410A Trane Pub. No.

Product Data TCC3018A through 4TCC3060A Single Packaged Convertible Cooling 13 SEER 1½ - 5 Ton R-410A 07/08

Product Data. 4TCY4024 through 4TCY4060 Single Packaged Convertible Cooling 14 SEER 2-5 Ton R-410A Trane Pub. No.

SEER 1½

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

Product Data TCC3018A through 4TCC3060A Single Package Convertible Cooling 13 SEER 1½ - 5 Ton R-410A. Mar. 03, 2006

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

Product Data WCC3018 through 4WCC3060 Single Packaged Convertible Heat Pump 13 SEER 1½ - 5 Ton R-410A 02/12

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

Submittal. Single Packaged Convertible Gas/Electric 14 SEER 4YCC4024A-SUB-1F-EN. August YCC4024A1060A TAG:

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

Split System Cooling Product & Performance Data

Split System Heat Pump Product & Performance Data

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Split System Cooling Product Data

Split System Cooling Product & Performance Data

36,000-62,000 BTUH Nominal Capacity

Product Data. Fig. 1 - Unit 50VR -A

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

Split System Cooling Product Data

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

High Heat COP. High/Low Stage

Split System Heat Pump Product Data

Split System Cooling Product Data

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

PAR5. Product Specifications

PAJ3. Product Specifications

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Heat Pump Product Data

Advance Release September 2009

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

AMERICAN STANDARD 14 MODELS 4A7B E

Split System Cooling Product Data

Split System Heat Pump Product Data

Split System Cooling Product Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

Split System Cooling Product Data

SPLIT SYSTEM COOLING 2, 3, 4 & 5 TON MODEL 4A7A American Standard Heating & Air Conditioning

Split System Heat Pump Product Data

Modular Multi-position Air Handler

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

Split System Cooling Product Data

Cooling/Heat Pump Convertible Air Handlers

Cooling/Heat Pump Convertible Air Handlers

RGE 13 A T - 1 A

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

Weathermaster Series 48HJ004, 005, 006, 007, 008, 009, 012 & 014 COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Split System Cooling Product Data

Product Data. Split System Cooling A. November 2013

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Split System Cooling Product Data

SPLIT SYSTEM COOLING 1 1 / 2 5 TON MODELS 4A7A

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Hyperion TM Split Systems

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

50TM TFF COMBINATION HEATING/COOLING UNITS

Model 655A Sizes

SPLIT SYSTEM HEAT PUMP 2, 3, 4 & 5 ton HERITAGE 20 MODELS 4A6Z0024, 036, 048, & 060A. with AccuLink and Charge Assist

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Cooling/Heat Pump Convertible Air Handlers

48TF GAS HEATING/ ELECTRIC COOLING UNITS

WPH4 Product Specifications

Product Data. Split System Heat Pump D-EN. February 2016

Product Data. Split System Cooling H-EN. January 2017

PACKAGE AIR CONDITIONER

Product Data. Split System Cooling E-EN. November 2016

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

50TM COMBINATION HEATING/COOLING UNITS

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Product Data. Split System Cooling D-EN. August 2016

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Roof Top Packaged Unit (RTU-1) Specification

Product Data. Split System Heat Pump A-EN. March 2016

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

SKYPAK II, 3 Ton Series, gives you a

Transcription:

Product Data 4DCZ6036A through 4DCZ6060A Single Packaged Convertible Dual Fuel 16 SEER 3, 4 & 5 Ton, 75-120 KBTU R-410A 2008 Trane Pub. No.

Single Packaged Convertible Dual Fuel System Trane offers a complete family of dual fuel heating and cooling systems, designed to keep you comfortable all year long, regardless of the weather, while keeping your operating costs as low as possible. The heat pump operates efficiently as both an air conditioner and a heater. In the summer, the heat pump cools your home just like any other air conditioner by pulling the heat from the inside and releasing it outdoors. In the winter, it captures the heat that is always present in the outdoor air and transfers it indoors. The gas furnace provides additional heating capacity for cooler weather. Introducing the new Trane Single Packaged Convertible Dual Fuel System. Single Packaged Convertible Dual Fuel Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane packaged dual fuel system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to a *CONT402, 802, or 803 comfort control and air distribution ducts, you have a highly efficient, total home comfort system. Single Packaged Dual Fuel Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service. Every Climatuff compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability. 2008 Trane 2

Contents Optional Equipment Listing 4 General Data 5 Performance Data Cooling 7 Heating 9 Indoor Blower Performance 11 Typical Wiring 13 Optional Equipment 16 Dimensional Data 21 Mechanical Specifications 27 3

Optional Equipment Listing OPTIONAL EQUIPMENT FOR 4DCZ6 PACKAGED UNITS (check mark [ ] indicates accessories included) Hinged Filter Access Door (DCZ6036) 8... BAYACCDOR1A[ ] Hinged Filter Access Door (DCZ6048-060) 8... BAYACCDOR2A[ ] Roof Curb Full Perimeter (4DCZ6036A) 3... BAYCURB050A[ ] Roof Curb Full Perimeter (4DCZ6048-060A) 3... BAYCURB051A[ ] Roof Curb Utility Extension Kit (BAYCURB050A)... BAYUTIL101B[ ] Roof Curb Utility Extension Kit (BAYCURB051A)... BAYUTIL102B[ ] Outside Air Control for V.S. Economizer (4DCZ6036A)... BAYOSAC001B[ ] Outside Air Control for V.S. Economizer (4DCZ6048-060)... BAYOSAC002B[ ] 0-25% Motorized Outside Air Damper (4DCZ6036)... BAYDMPR101A[ ] 0-25% Motorized Outside Air Damper (4DCZ6048-060)... BAYDMPR102A[ ] 0-25% Manual Fresh Air Damper (4DCZ6036A) 1... BAYOSAH001A[ ] 0-25% Manual Fresh Air Damper (4DCZ6048-60A) 1... BAYOSAH002A[ ] 16" Round Duct Adapter (2 per box) (4DCZ6036A) 6... BAYSQRD001A[ ] 18" Round Duct Adapter (2 per box) (4DCZ6036-060A) 6... BAYSQRD002A[ ] 0-100% Mod Economizer w/baro. Relief (4DCZ6036A) 124... BAYECON103A[ ] 0-100% Mod. Economizer w/baro. Relief (4DCZ6048-060A) 124.... BAYECON104A[ ] 0-100% Horizontal Economizer (4DCZ6036A) 12.... BAYECON203A[ ] 0-100% Horizontal Economizer (4DCZ6048-060A) 12.... BAYECON204A[ ] Economizer Relay Kit (required for Heat Pump applications)... BAYRLAY006A[ ] Enthalpy Control for Economizer (solid state).... BAYENTH001A[ ] Remote Potentiometer (All-BAYECON***A)... BAYSTAT023[ ] 1"-2" Filter Frame (4DCZ6036A) (20 x 25 filter not included) 1.... BAYFLTR101B[ ] 1"-2" Filter Frame (4DCZ6048-060A) (20 x 20,20X18 filter not included) 1.... BAYFLTR201B[ ] Evaporator Defrost Control (Low Ambient Cooling) Kit 5.... BAYLOAM011A[ ] Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5.... BAYLOAM105A[ ] Crankcase Heater Scroll(4DCZ6036,48, 60A1/3)(230v) 5.... BAYCCHT102A[ ] Crankcase Heater Scroll (4DCZ6036-060A3)(460v) 5.... BAYCCHT404B[ ] Adapter Curb 4DCZ6036A to BAYCURB030,38... BAYADAP050A[ ] Adapter Curb 4DCZ6036A to BAYCURB033... BAYADAP051A[ ] Adapter Curb 4DCZ6048-60A to BAYCURB030,38... BAYADAP052A[ ] Adapter Curb 4DCZ6048-60A to BAYCURB033... BAYADAP053A[ ] Adapter Curb 4DCZ6048-60A to BAYCURB034... BAYADAP054A[ ] 12" Duct Shroud Covers Horizontal 4DCZ6036-60A7.... BAYCOVR112A[ ] 18" Duct Shroud Covers Horizontal 4DCZ6036-60A 7.... BAYCOVR118A[ ] Extreme Condition Mounting Kit - All BAYCURB & BAYADAP... BAYEXMK001A[ ] Extreme Condition Mounting Kit - All BAYUTIL... BAYEXMK002A[ ] Extreme Condition Mounting Kit - All Slab Mounts... BAYEXMK003A[ ] Lifting Lug Kit (All Models)... BAYLlFT002B[ ] LP Conversion Kit (All 40K, 120K Models)... BAYLPKT100A[ ] LP Conversion Kit (All 64K, 96K Models)... BAYLPKT101A[ ] LP Conversion Kit (All 75K Models)... BAYLPKT102A[ ] NOTES: 1 Must use internal filter frame when economizer or fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications. 8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. 4

MODEL RATED Volts/PH/Hz Performance Cooling BTUH BTUH (High) Indoor Airflow (CFM) Power Input (KW) BTUH (Low) Indoor Airflow (CFM) Power Input (KW) EER - HI / LOW / SEER Sound Power Rating [db(a)]7 HP Heating Performance (High Temp.)BTUH / COP (High) Power Input (KW) (Low Temp.) BTUH / COP (High) Power Input (KW) (High Temp.)BTUH / COP (Low) Power Input (KW) (Low Temp.) BTUH / COP (Low) Power Input (KW) HSPF (BTU / Watt-Hr.) Gas Heating Performance Input BTUH - 1st Stage (Natural Gas) Input BTUH - 2nd Stage (Natural Gas) AFUE Temp. Rise Min/Max ( F) Orifice Qty / Drill Size (Natural Gas) POWER CONN. V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size Max. / Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN TYPE Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT / Charge (lbs.) GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT / Shipping / Net (lbs.) 4DCZ6036A1075A 35000 1125 2.63 25000 825 1.89 12 / 13.23 / 16 70 34000 / 3.75 2.63 21000 / 2.55 2.41 23800 / 3.8 1.83 12800 / 2.1 1.77 9 56250 75000 79.5 30 / 60 2 / #33 26.2 40 / 40 2-STAGE SCROLL 16.7 / 82 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 15.49 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 1 / 1 1/6 / 830 1.0 / 1.65 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 4.0 R410A / 7.8 1/2 H X W X L 47.86 / 44.5 / 52.03 488 / 392 General Data 4DCZ6036A3075A 208-230/3/60 35000 1125 2.63 25000 825 1.89 12 / 13.23 / 16 70 34000 / 3.75 2.63 21000 / 2.55 2.41 23800 / 3.8 1.83 12800 / 2.1 1.77 9 56250 75000 79.5 30 / 60 2 / #33 208-230/3/60 19.1 30 / 30 2-STAGE SCROLL 208-230/3/60 11.2 / 58 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 15.49 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 1 / 1 1/6 / 830.9 / 1.65 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1/2 / VARIABLE 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 4.0 R410A / 7.8 1/2 H X W X L 47.86 / 44.5 / 52.03 488 / 392 4DCZ6048A1096A 47500 1575 3.35 35500 1150 2.59 12 / 13.65 / 16 71 44500 / 4 3.35 27500 / 2.71 2.97 32500 / 4 2.37 18500 / 2.42 2.25 9 72000 96000 80 30 / 60 3 / #37 34.1 50 / 50 2-STAGE SCROLL 21.2 / 96 SPINE-FIN 2 / 24 23.57 3/8 PLATE FIN 4 / 15 23.57 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 1 / 1 1/6 / 830 0.9 / 1.7 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 5.3 R410A / 8.8 1/2 H X W X L 51.86 / 47.4 / 61.75 665 / 537 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 5

MODEL RATED Volts/PH/Hz Performance Cooling BTUH BTUH (High) Indoor Airflow (CFM) Power Input (KW) BTUH (Low) Indoor Airflow (CFM) Power Input (KW) EER - HI / LOW / SEER Sound Power Rating [db(a)]7 HP Heating Performance (High Temp.)BTUH / COP (High) Power Input (KW) (Low Temp.) BTUH / COP (High) Power Input (KW) (High Temp.)BTUH / COP (Low) Power Input (KW) (Low Temp.) BTUH / COP (Low) Power Input (KW) HSPF (BTU / Watt-Hr.) Gas Heating Performance Input BTUH - 1st Stage (Natural Gas) Input BTUH - 2nd Stage (Natural Gas) AFUE Temp. Rise Min/Max ( F) Orifice Qty / Drill Size (Natural Gas) POWER CONN. V/PH/HZ Min. Brch. Cir. Ampacity Fuse Size Max. / Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps L.R. Amps OUTDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN TYPE Dia. (in.) Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g. Motor HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN TYPE Drive/No. Speeds Motor HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.) REFRIGERANT / Charge (lbs.) GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT / Shipping / Net (lbs.) 4DCZ6048A3096A 208-230/3/60 47500 1575 3.35 35500 1150 2.59 12 / 13.65 / 16 71 44500 / 4 3.35 27500 / 2.71 2.97 32500 / 4 2.37 18500 / 2.42 2.25 9 72000 96000 80 30 / 60 3 / #37 208-230/3/60 24.5 35 / 35 2-STAGE SCROLL 208-230/3/60 13.5 / 88 SPINE-FIN 2 / 24 23.57 3/8 PLATE FIN 4 / 15 23.57 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 1 / 1 1/6 / 830 0.9 / 1.7 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 3/4 / VARIABLE 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 5.3 R410A / 8.8 1/2 H X W X L 51.86 / 47.4 / 61.75 665 / 537 General Data 4DCZ6060A1120A 57000 1900 4.38 40500 1350 3.26 11.5 / 12.5 / 15.2 73 55000 / 3.8 4.38 34500 / 2.52 4 39000 / 3.63 3.14 23000 / 2.21 3.03 8.6 90000 120000 80 30 / 60 3 / #32 37.1 60 / 60 2-STAGE SCROLL 23 / 118 SPINE-FIN 2 / 24 23.57 3/8 PLATE FIN 4 / 15 23.57 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 1 / 1 1/4 / 830 1.4 / 3.4 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1 / VARIABLE 6.9 / 6.9 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 6.7 R410A / 9.4 1/2 H X W X L 51.86 / 47.4 / 61.75 676 / 548 4DCZ6060A3120A 208-230/3/60 57000 1900 4.38 40500 1350 3.26 11.5 / 12.5 / 15.2 73 55000 / 3.8 4.38 34500 / 2.52 4 39000 / 3.63 3.14 23000 / 2.21 3.03 8.6 90000 120000 80 30 / 60 3 / #32 208-230/3/60 30.3 45 / 45 2-STAGE SCROLL 208-230/3/60 17.6 / 123 SPINE-FIN 2 / 24 23.57 3/8 PLATE FIN 4 / 15 23.57 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 1 / 1 1/4 / 830 1.4 / 3.4 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERFORMANCE TABLE 1 / VARIABLE 6.9 / 6.9 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 0.34 NO THROWAWAY 6.7 R410A / 9.4 1/2 H X W X L 51.86 / 47.4 / 61.75 676 / 548 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 6

Performance Data Cooling HIGH STAGE: 4DCZ6036A AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 85 95 105 115 59 34.2 28.7 32.3 34.2 34.2 2.6 63 35.7 23.3 26.9 30.5 32.9 2.6 67 38.4 18.4 22.0 25.6 27.9 2.7 71 41.5 13.5 17.0 20.6 23.0 2.7 59 31.9 27.7 31.3 31.9 31.9 2.9 63 33.2 22.4 25.9 29.5 31.9 2.9 67 35.8 17.4 21.0 24.5 27.0 2.9 71 38.6 12.5 16.1 19.6 22.0 2.9 59 29.5 26.6 29.5 29.5 29.5 3.1 63 30.8 21.4 24.9 28.5 30.8 3.1 67 33.2 16.4 20.0 23.6 26.0 3.2 71 35.8 11.5 15.1 18.6 21.0 3.2 59 27.2 25.6 27.2 27.2 27.2 3.4 63 28.3 20.4 24.0 27.5 28.3 3.4 67 30.5 15.5 19.0 22.6 25.0 3.5 71 32.9 10.5 14.1 17.7 20.1 3.5 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1050 0.97 0.98 HIGH 1350 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1065 35000 16.00 12.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4DCZ6036A AT 900 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 75 85 90 95 59 25.4 21.6 24.2 25.4 25.4 1.4 63 26.4 17.5 20.2 22.9 24.7 1.4 67 28.5 13.8 16.5 19.2 21.0 1.4 71 30.8 10.1 12.8 15.5 17.3 1.4 59 23.5 20.7 23.4 23.5 23.5 1.6 63 24.5 16.7 19.4 22.1 23.9 1.6 67 26.4 13.0 15.7 18.4 20.2 1.6 71 28.5 9.3 12.0 14.7 16.5 1.6 59 22.6 20.3 22.6 22.6 22.6 1.7 63 23.5 16.3 19.0 21.7 23.5 1.7 67 25.4 12.6 15.3 18.0 19.8 1.7 71 27.4 8.9 11.6 14.3 16.1 1.7 59 21.6 19.9 21.6 21.6 21.6 1.8 63 22.6 15.9 18.6 21.3 22.6 1.8 67 24.3 12.3 15.0 17.6 19.4 1.8 71 26.3 8.5 11.2 13.9 15.7 1.8 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 790 0.97 0.98 HIGH 1010 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 840 25020 16.00 13.23 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. HIGH STAGE: 4DCZ6048A AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 85 95 105 115 59 45.3 38.7 43.6 45.3 45.3 3.6 63 47.3 31.3 36.2 41.1 44.4 3.6 67 50.9 24.5 29.4 34.3 37.6 3.6 71 55.0 17.6 22.5 27.4 30.8 3.6 59 42.3 37.4 42.3 42.3 42.3 3.9 63 44.2 30.0 34.9 39.8 43.1 3.9 67 47.6 23.2 28.1 33.0 36.3 4.0 71 51.4 16.3 21.3 26.2 29.5 4.0 59 39.4 36.0 39.4 39.4 39.4 4.2 63 41.0 28.7 33.7 38.6 41.0 4.2 67 44.2 21.9 26.9 31.8 35.1 4.3 71 47.8 15.1 20.0 25.0 28.3 4.3 59 36.4 34.7 36.4 36.4 36.4 4.5 63 37.9 27.5 32.4 37.3 37.9 4.5 67 40.9 20.7 25.6 30.6 33.9 4.6 71 44.1 13.9 18.8 23.8 27.1 4.6 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1400 0.97 0.98 HIGH 1800 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1585 47500 16.00 12.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 7

Performance Data Cooling LOW STAGE: 4DCZ6048A AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 75 85 90 95 59 34.4 29.2 32.9 34.4 34.4 1.9 63 35.9 23.7 27.4 31.0 33.4 1.9 67 38.7 18.7 22.4 26.0 28.4 1.9 71 41.8 13.7 17.3 20.9 23.4 1.9 59 32.2 28.2 31.9 32.2 32.2 2.1 63 33.5 22.7 26.4 30.1 32.5 2.2 67 36.1 17.7 21.4 25.0 27.4 2.2 71 39.0 12.7 16.3 20.0 22.4 2.2 59 31.0 27.7 31.0 31.0 31.0 2.3 63 32.3 22.3 25.9 29.6 32.0 2.3 67 34.8 17.3 20.9 24.6 27.0 2.3 71 37.6 12.2 15.9 19.5 21.9 2.3 59 29.9 27.2 29.9 29.9 29.9 2.4 63 31.2 21.8 25.4 29.1 31.2 2.4 67 33.6 16.8 20.4 24.1 26.5 2.5 71 36.2 11.8 15.4 19.1 21.5 2.5 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1050 0.97 0.98 HIGH 1350 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1165 35107 16.00 13.58 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. HIGH STAGE: 4DCZ6060A AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 85 95 105 115 59 54.4 46.9 53.1 54.4 54.4 4.4 63 56.7 37.8 43.9 50.0 54.1 4.5 67 61.1 29.3 35.4 41.5 45.6 4.5 71 65.9 20.8 26.9 33.0 37.1 4.5 59 51.3 45.5 51.3 51.3 51.3 4.9 63 53.5 36.5 42.6 48.7 52.7 4.9 67 57.6 28.0 34.1 40.2 44.3 5.0 71 62.2 19.5 25.6 31.8 35.8 5.0 59 48.2 44.2 48.2 48.2 48.2 5.3 63 50.3 35.2 41.3 47.4 50.3 5.3 67 54.2 26.7 32.9 38.9 43.0 5.4 71 58.5 18.3 24.3 30.5 34.6 5.4 59 45.2 42.9 45.2 45.2 45.2 5.7 63 47.1 33.9 40.0 46.1 47.1 5.8 67 50.7 25.5 31.6 37.7 41.8 5.9 71 54.8 17.0 23.1 29.3 33.3 5.9 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1750 0.97 0.98 HIGH 2250 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1885 57000 15.20 11.50 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4DCZ6060A AT 1500 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD ID TOT SENS CAP AT ENTERING DB TEMP TOTAL AMB WB CAP 72 75 78 80 KW 75 85 90 95 59 40.3 35.2 39.7 40.3 40.3 2.3 63 42.0 28.4 33.0 37.5 40.5 2.3 67 45.3 22.2 26.7 31.2 34.2 2.3 71 48.9 15.9 20.4 25.0 28.0 2.3 59 37.6 34.0 37.6 37.6 37.6 2.7 63 39.2 27.3 31.8 36.4 39.2 2.7 67 42.3 21.1 25.6 30.1 33.1 2.7 71 45.6 14.8 19.3 23.9 26.9 2.7 59 36.3 33.4 36.3 36.3 36.3 2.8 63 37.8 26.7 31.2 35.8 37.8 2.9 67 40.8 20.5 25.0 29.6 32.6 2.9 71 44.0 14.3 18.8 23.3 26.3 2.9 59 34.9 32.8 34.9 34.9 34.9 3.0 63 36.4 26.2 30.7 35.2 36.4 3.0 67 39.2 20.0 24.5 29.0 32.0 3.1 71 42.4 13.7 18.2 22.8 25.8 3.1 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1310 0.97 0.98 HIGH 1680 1.03 1.02 ARI RATING FOR COOLING CFM CAPACITY (A) TEST SEER EER 1320 40743 15.20 12.50 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 8

Performance Data Heating HIGH STAGE: 4DCZ6036A AT 1200 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 2 14.2 13.9 13.8 13.7 2.2 2.3 2.4 2.4 7 16.5 16.2 16.1 15.9 2.2 2.3 2.4 2.5 12 18.9 18.6 18.4 18.2 2.2 2.4 2.5 2.5 17 21.3 20.9 20.7 20.5 2.3 2.4 2.5 2.6 22 21.7 21.3 21.1 20.9 2.3 2.4 2.5 2.6 27 22.2 21.7 21.5 21.3 2.2 2.4 2.5 2.5 32 22.6 22.2 22.0 21.8 2.2 2.4 2.4 2.5 37 25.0 24.5 24.3 24.0 2.3 2.4 2.5 2.6 42 30.2 29.6 29.3 29.1 2.4 2.6 2.6 2.7 47 35.4 34.8 34.4 34.1 2.5 2.7 2.8 2.9 52 37.8 37.1 36.7 36.4 2.6 2.7 2.8 2.9 57 40.2 39.4 39.0 38.7 2.6 2.8 2.9 2.9 62 42.5 41.7 41.3 40.9 2.7 2.8 2.9 3.0 67 44.9 44.1 43.6 43.2 2.7 2.9 3.0 3.0 72 47.3 46.4 45.9 45.5 2.7 2.9 3.0 3.1 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1050 0.987 0.975 HIGH 1350 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 1065 34000 3.75 20400 2.50 9.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4DCZ6036A AT 900 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 22 14.3 14.1 13.9 13.8 1.6 1.7 1.8 1.9 27 15.4 15.1 15.0 14.8 1.7 1.8 1.8 1.9 32 16.5 16.1 16.0 15.8 1.7 1.8 1.8 1.9 37 18.2 17.9 17.7 17.5 1.7 1.8 1.9 1.9 42 21.0 20.6 20.4 20.2 1.7 1.8 1.8 1.9 47 23.7 23.3 23.1 22.9 1.7 1.8 1.8 1.9 52 25.5 25.0 24.8 24.5 1.7 1.8 1.9 1.9 57 27.2 26.7 26.5 26.2 1.7 1.8 1.9 1.9 62 29.0 28.4 28.2 27.9 1.7 1.8 1.9 1.9 67 30.7 30.1 29.8 29.6 1.7 1.8 1.9 1.9 72 32.5 31.9 31.5 31.3 1.7 1.8 1.9 2.0 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 800 0.987 0.975 HIGH 1025 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 840 23005 3.79 12872 2.20 9.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. HIGH STAGE: 4DCZ6048A AT 1600 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 2 18.6 18.3 18.1 17.9 2.5 2.7 2.8 2.8 7 21.6 21.2 21.0 20.8 2.6 2.7 2.8 2.9 12 24.6 24.1 23.9 23.7 2.6 2.8 2.9 3.0 17 27.6 27.1 26.8 26.5 2.7 2.9 3.0 3.0 22 28.4 27.9 27.6 27.3 2.7 2.9 3.0 3.1 27 29.2 28.7 28.4 28.1 2.7 2.9 3.0 3.1 32 30.1 29.5 29.2 28.9 2.8 2.9 3.0 3.1 37 33.0 32.4 32.1 31.8 2.8 3.0 3.1 3.2 42 39.2 38.5 38.1 37.8 2.9 3.1 3.2 3.3 47 45.4 44.6 44.1 43.7 3.1 3.3 3.4 3.5 52 48.4 47.5 47.0 46.6 3.1 3.3 3.4 3.5 57 51.4 50.4 49.9 49.5 3.2 3.4 3.5 3.6 62 54.4 53.3 52.8 52.3 3.3 3.5 3.6 3.7 67 57.3 56.3 55.7 55.2 3.3 3.5 3.6 3.7 72 60.3 59.2 58.6 58.1 3.4 3.6 3.7 3.8 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1400 0.987 0.975 HIGH 1800 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 1585 44500 4.00 27000 2.76 9.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 9

Performance Data Heating LOW STAGE: 4DCZ6048A AT 1200 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 22 20.6 20.2 20.0 19.8 2.1 2.3 2.3 2.4 27 22.3 21.9 21.7 21.5 2.2 2.3 2.4 2.4 32 24.0 23.6 23.3 23.1 2.2 2.3 2.4 2.5 37 26.3 25.8 25.6 25.3 2.2 2.4 2.4 2.5 42 29.4 28.9 28.6 28.3 2.2 2.4 2.4 2.5 47 32.6 32.0 31.7 31.4 2.2 2.4 2.4 2.5 52 34.9 34.2 33.9 33.6 2.2 2.4 2.4 2.5 57 37.1 36.5 36.1 35.8 2.3 2.4 2.5 2.5 62 39.4 38.7 38.3 38.0 2.3 2.4 2.5 2.6 67 41.7 40.9 40.5 40.2 2.3 2.4 2.5 2.6 72 44.0 43.2 42.7 42.4 2.3 2.5 2.5 2.6 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1050 0.987 0.975 HIGH 1350 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 1165 31799 3.98 18430 2.44 9.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. HIGH STAGE: 4DCZ6060A AT 2000 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 2 23.3 22.9 22.6 22.4 3.6 3.8 3.9 4.0 7 27.0 26.5 26.2 26.0 3.6 3.9 4.0 4.1 12 30.7 30.1 29.8 29.6 3.7 3.9 4.0 4.1 17 34.4 33.8 33.4 33.1 3.7 4.0 4.1 4.2 22 35.0 34.4 34.0 33.7 3.7 3.9 4.1 4.2 27 35.7 35.0 34.6 34.3 3.7 3.9 4.0 4.2 32 36.3 35.6 35.2 34.9 3.7 3.9 4.0 4.1 37 40.0 39.2 38.8 38.5 3.7 4.0 4.1 4.2 42 48.3 47.4 47.0 46.5 3.9 4.1 4.2 4.4 47 56.7 55.6 55.1 54.6 4.0 4.3 4.4 4.5 52 60.4 59.2 58.7 58.1 4.1 4.3 4.5 4.6 57 64.1 62.9 62.3 61.7 4.1 4.4 4.5 4.7 62 67.8 66.5 65.9 65.3 4.2 4.5 4.6 4.7 67 71.5 70.2 69.5 68.8 4.2 4.5 4.6 4.8 72 75.2 73.8 73.1 72.4 4.3 4.6 4.7 4.8 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1750 0.987 0.975 HIGH 2250 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 1885 55000 3.80 33400 2.50 8.60 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. LOW STAGE: 4DCZ6060A AT 1500 NOM CFM (HEATING PERFORMANCE AT INDOOR DRY BULB TEMPERATURE) OD TOTAL CAPACITY MBH TOTAL POWER IN KILOWATTS AMB 60 70 75 80 60 70 75 80 22 24.9 24.4 24.2 24.0 2.8 3.0 3.1 3.2 27 26.7 26.2 25.9 25.7 2.8 3.0 3.1 3.2 32 28.5 28.0 27.7 27.4 2.9 3.1 3.1 3.2 37 31.2 30.6 30.3 30.1 2.9 3.1 3.2 3.3 42 35.3 34.6 34.3 34.0 2.9 3.1 3.2 3.3 47 39.4 38.6 38.3 37.9 2.9 3.1 3.2 3.3 52 42.1 41.3 40.9 40.5 2.9 3.1 3.2 3.3 57 44.8 44.0 43.5 43.1 2.9 3.1 3.2 3.3 62 47.5 46.6 46.2 45.7 3.0 3.1 3.2 3.3 67 50.2 49.3 48.8 48.4 3.0 3.2 3.3 3.3 72 52.9 52.0 51.4 51.0 3.0 3.2 3.3 3.4 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1325 0.987 0.975 HIGH 1700 1.011 1.025 ARI RATING FOR HEATING CFM CAPACITY 47 COP 47 CAPACITY 17 COP 17 HSPF 1320 37709 3.63 22106 2.21 8.60 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS (A) Cooling 80 F DB, 67 F WB air entering indoor coil, 95 F DB air entering outdoor coil. (B) High Temperature Heating 47 F DB, 43 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (C) Low Temperature Heating 17 F DB, 15 F WB air entering outdoor coil, 70 F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 10

Indoor Blower Performance Indoor Fan Performance 4DCZ6036A Horizontal 350 CFM/Ton Setting 400 CFM/Ton Setting 450 CFM/Ton Setting External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low - 741 743 744 744 743 742 740 737 - - High - 1059 1062 1063 1063 1062 1059 1057 1053 - - Low - 825 837 843 844 844 842 839 836 - - High - 1179 1196 1204 1206 1205 1203 1199 1194 - - Low - 976 964 959 957 953 949 945 945 - - High - 1394 1377 1371 1367 1362 1355 1350 1350 - - Down Flow 350 CFM/Ton Setting 400 CFM/Ton Setting 450 CFM/Ton Setting External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Low - 722 745 747 744 742 743 744 736 - - High - 1032 1064 1068 1063 1060 1062 1063 1052 - - Low - 830 841 842 840 839 838 836 828 - - High - 1186 1201 1203 1201 1198 1197 1194 1184 - - Low - 978 965 964 963 958 948 941 949 - - High - 1397 1378 1377 1376 1368 1354 1344 1356 - - Indoor Fan Performance 4DCZ6048A Horizontal 350 CFM/Ton Setting 400 CFM/Ton Setting 450 CFM/Ton Setting Down Flow 350 CFM/Ton Setting 400 CFM/Ton Setting 450 CFM/Ton Setting External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low - 954 973 977 973 966 957 950 944 - - High - 1363 1390 1396 1390 1379 1368 1358 1349 - - Low - 1121 1106 1104 1106 1108 1108 1104 1097 - - High - 1601 1580 1577 1580 1583 1583 1577 1567 - - Low - 1223 1254 1268 1271 1268 1264 1261 1258 - - High - 1747 1792 1811 1816 1812 1806 1801 1797 - - External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low - 948 977 977 970 969 975 979 962 - - High - 1354 1396 1396 1386 1384 1393 1399 1375 - - Low - 1102 1106 1109 1113 1116 1119 1120 1118 - - High - 1574 1580 1585 1589 1594 1599 1601 1597 - - Low - 1295 1277 1272 1273 1274 1273 1272 1273 - - High - 1851 1824 1817 1818 1820 1819 1817 1819 - - Indoor Fan Performance 4DCZ6060A Horizontal 350 CFM/Ton Setting 400 CFM/Ton Setting Down Flow 350 CFM/Ton Setting 400 CFM/Ton Setting External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low 1163 1238 1259 1256 1246 1240 1237 1230 High - 1662 1768 1799 1794 1780 1771 1767 1757 - - Low 1443 1427 1422 1422 1423 1422 1418 1410 High - 2062 2038 2031 2032 2034 2032 2025 2015 - - External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Low - 1259 1219 1208 1207 1206 1199 1188 1185 - - High - 1799 1742 1726 1725 1723 1712 1698 1692 - - Low - 1410 1393 1386 1384 1383 1380 1368 1344 - - High - 2015 1990 1980 1977 1976 1971 1955 1920 - - 11

Indoor Blower Performance 4DCZ6036 Auxiliary Heating Airflow, horizontal or downflow from.2 to.6 wg. Switch Settings Selection Nominal Airflow Low Stage High Stage 7-OFF 8-OFF A 725 1000 7-ON 8-OFF B 775 1075 7-OFF 8-ON C 850 1150 7-ON 8-ON D 925 1250 4DCZ6048 Auxiliary Heating Airflow, horizontal or downflow from.2 to.6 wg. Switch Settings Selection Nominal Airflow Low Stage High Stage 7-OFF 8-OFF A 1075 1375 7-ON 8-OFF B 1100 1450 7-OFF 8-ON C 1150 1500 7-ON 8-ON D 1200 1575 4DCZ6 Auxiliary Heating Airflow, horizontal or downflow from.2 to.6 wg. Switch Settings Selection Nominal Airflow Low Stage High Stage 7-OFF 8-OFF A 1375 1800 7-ON 8-OFF B 1450 1900 7-OFF 8-ON C 1525 1975 7-ON 8-ON D 1575 2075 COOLING FAN DELAY OPTIONS NOMINAL SWITCH SETTINGS DELAY AIRFLOW 5-OFF 6-OFF NONE 100% 5-ON 6-OFF 45 SEC 100% 5-OFF 6-ON 90 SEC 50% 5-ON 6-ON ** 50-100% ** This ENHANCED MODE selection provides a ramping up and ramping down of the indoor blower speed to provide improved comfort, quietness, and potential energy savings. The Graph below shows the ramping process SYSTEM AIRFLOW (CFM) OFF 50% 35% 1 minute 80% SECOND STAGE 56% FIRST STAGE Dehumidify Fast Coil Cooling Enhanced Comfort 7.5 minutes COMPRESSOR OPERATION ON 100% Only if required 70% Only if required Enhanced Efficiency 3 minutes (Fan Only) OFF 50% 35% OFF 12

Typical Field Wiring 4DCZ6 FIELD WIRING DIAGRAM Y2 (YL/RD) 2ND STAGE COMPRESSOR 1ST STAGE COMPRESSOR 13

Typical Wiring 14

Typical Wiring 15

Optional Equipment BAYCURB050A FULL PERIMETER ROOF MOUNTING CURB FOR *****018-036A 17 7/8 46 3/8 3 3 5/8 19 1/2 2 3/16 15 19 1/2 38 7/8 14 1 1/2 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 35 7/8 43 3/8 16

Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 15 7/8 56 1/8 3 1 1/2 20 19 1/2 4 3/4 10 7/8 41 7/8 19 1/2 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 38 7/8 53 1/8 17

Optional Equipment BAYFLTR101, 201B, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 18

BAYECON103,104A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Optional Equipment A Economizer rain hood Economizer Models A Mist eliminator Outside air dampers Return air dampers Required filter kit, order separately BAYECON103A BAYECON104A 4WCZ6036A 4DCZ6036A 4YCZ6036A 4WCZ6048-060A 4DCZ6048-060A 4YCZ6048-060A 20 1/8" 24 3/8" Relief damper Roofcurb Return Duct BAYECON203,204A Horizontal Economizer and Rain Hood Economizer A C B D Gaskets (2) Duct E Mixed Air Sensor Economizer A B C D E BAYECON203AA 22" 20" 16 7/8" 15 11/16 11 11/16 BAYECON204AA 24" 22 21/32" 19" 17 11/16 14 11/16 Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 19

Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. D C A FULLY OPEN 2/3 1/3 B FULLY CLOSED Manual Fresh Air Model BAYOSAH001 BAYOSAH002 Unit Application Models 2/4YC,WC3018-036A 4TC*3018-036A 4W/T/Y/DCY4024-036A 4W/Y/DCZ6036A 2/4YC,WC3042-060A 4TC*3042-060A 4W/T/Y/DCY4042-060 4W/Y/DCZ6048-060A A B C D 22 7/16" 20 11/16" 12 3/8" 9 3/16" 25 3/16" 20 11/16" 12 3/8" 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C B E BAYDMPR101A BAYDMPR102A Unit Application Models 2/4YC,WC3018-036A 4TC3018-036A 4W/T/Y/DCY4024-036A 4W/Y/DCZ6036A 2/4YC,WC3042-060A 4TC3042-060A 4W/T/Y/DCY4042-060A 4W/Y/DCZ6048-060A A B C D E 15 13/16" 11 13/16" 10 1/4" 11 1/2" 12 1/4" 18 3/16" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 20 D

Dimensional Data 4DCZ6036A (1 of 3) 21

Dimensional Data 4DCZ6036A (2 of 3) 22

Dimensional Data 4DCZ6036A (3 of 3) 23

Dimensional Data 4DCZ6048A through 4DCZ6060A (1 of 3) 24

Dimensional Data 4DCZ6048A through 4DCZ6060A (2 of 3) 25

Dimensional Data 4DCZ6048A through 4DCZ6060A (3 of 3)

General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 115 F. Cooling capacities shall be rated in accordance with A.R.I. standards. The 4DCZ6 heating/cooling unit design is UL listed, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Shipped for horizontal application, convertible to downflow. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced insulation shall be in the heat exchanger section. Foil-faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Refrigeration System Compressors The Climatuff compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. Evaporator Coil Internally enhanced 3/8-inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow. Mechanical Specifications Condenser Coil The Spine Fin condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan Direct-drive, forwardcurved, centrifugal wheel in a Composite Vortica Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan Direct-drive, draw through propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. Low Ambient Standard refrigerant system operation down to 55 F. Low ambient accessory required for operation to 0 F ambient condition. Gas-Fired Heating System Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System Main burner is lit each time thermostat calls for gas heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger stainless steel tubes. Free floating design. Burners Stainless steel. Multiport inshot. Accessories (U.S. Domestic Models) Roof Curb The roof curb shall be designed to mate with the unit and provide support and complete weather-tight installation when properly installed. Curb shall ship knocked down for field assembly, and include wood nailer strips. Modulating Economizer This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor fixed dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment off cycle. Manual Fresh Air Hood Manual outside air provides a fixed outside air quantity from 0 to 25 percent. Includes hood and birdscreen. Low Ambient Control Control allows cycling of compressor under low ambient cooling conditions. Required for cooling operation to 0 F. Propane Gas Conversion Kit For conversion from natural gas to LP gas. Trane 6200 Troup Highway Tyler, TX 75707-9010 The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.