THERMAL STORE MAINS PRESSURE SYSTEM

Similar documents
THERMAL STORE MAINS PRESSURE SYSTEM

THERMflow Thermal Store Cylinders

CUBEflow Thermal Store Tank

UN-VENTED & VENTED STAINLESS STEEL HOT WATER CYLINDERS

Stainless Steel Unvented Cylinders

Torrent ECO. The final piece in your heating and hot water system. Open vented thermal store providing heating and mains pressure hot water

ADVANCE ECB ELECTRIC COMBINATION BOILER

Where gas is not an option,

Xcel HEATBANK Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

Renewable Range Cylinders providing a perfect partnership with renewable energy inputs SUPPLIERS TO THE MERCHANT TRADE FOR OVER 40 YEARS

HEATBANK Xcel Thermal Store The solution to multi-fuel heating. Renewable Energy Solutions

TORRENT ECO ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

TORRENT STAINLESS ONE NAME. EVERY SOLUTION. OPEN VENTED THERMAL STORE PROVIDING HEATING AND MAINS PRESSURE HOT WATER

Series 1000 & Storage Water Heaters

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

H o t Wa te r Syste m s. Senator Electric Flow Boilers. Making Life Simpler

Mains pressure hot water for fast filling baths and powerful showers Simultaneous supply of water to all bathrooms Long life low maintenance hot

ENERSTORE. Vented Hot Water Storage System INSTRUCTIONS PLEASE LEAVE WITH HOUSEHOLDER

STAINLESSLITE ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

JASPI GTV & Oval thermal storage

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Thermaflow. Creating Excellence, Building Reputation Unvented Water Storage From The Experts... Thermaflow Thermaflow. Thermaflow.

VENTED CYLINDER RANGE

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

STAINLESSLITE PLUS ONE NAME. EVERY SOLUTION. UNVENTED MAINS PRESSURE AND VENTED WATER STORAGE CYLINDERS

Torrent GreenHeat. Design, Installation & Servicing Instructions. Open vented thermal store providing heating and mains pressure hot water

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

Water Heating Systems

pod Installation, Operation & Maintenance viridian Pod-PV, Pod-ST solar v

A Hot water revolution

XCEL HEAT BANKS Installation Instructions. Thermal Integration Ltd., 1-3 Wealdstone Road, Sutton, Surrey SM3 9QN.

TORRENT ECO INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

Design, Installation & Servicing Instructions. A total hot water and heating thermal store that can also make the most of renewable energy

S T O R E R A N G E C Y L I N D E R & G R A N T FEATURES: GRANT MONOWAVE UNVENTED DIRECT AND INDIRECT SINGLE-COIL CYLINDERS

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

Why Vaillant? Home Heating Guide. Because they can reduce our heating bills and our carbon footprint

Installation and Commissioning Manual

Risk Assessment and Control Measures for Household Hot Water Systems

AquaCyl solar system solar water heating solution for the larger home with greater hot water demand (2 or more bathrooms in use simultaneously)

EXCELLENCE IN HOT WATER TECHNOLOGY CYLINDER PRODUCT GUIDE

the electric heating company ELECTRIC BOILER HANDBOOK

H ot Wa te r Syste m s. Copper Hot Water Products. Making Life Simpler

INTERCYL. INTERNAL EXPANSION EXCELLENCE

A HOT WATER REVOLUTION

Jaspi GTV and Jaspi Oval. Jaspi Oval thermal storage tanks

TORRENT STAINLESS INSTRUCTION MANUAL DESIGN, INSTALLATION & SERVICING ONE NAME. EVERY SOLUTION.

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

The Ultimate Solution for Electric Central Heating. Fusion. Comet

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

H o t Wa te r Syste m s. Tribune HE Unvented Hot Water Cylinders. Making Life Simpler

Section 7 F/602/2884 Understand and apply domestic hot water system installation and maintenance techniques

QUALITY DESIGN. BUILT-IN RELIABILITY. CYLINDERS. The complete range of Warmflow Cylinders.

Broag Pressurisation equipment

Plus. USER and INSTALLATION INSTRUCTIONS. 30,000-9kW for Heating and Hot Water

Link-Up. Solid Fuel Association Guide to Central Heating.

AquaFlo II. Issue 3 December Please read these instructions carefully before commencing installation of the AquaFlo unvented water heater

Multipoint Technical Data

Installation & User Instructions

Total Hot Water Solutions

Re n ewa b l e s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

A-Class. A-Rated Homes with Dimplex heat pumps. The name you can trust. Building Regulations and Part L Compliance made easy with Dimplex. dimplex.

Unvented Hot Water Systems for the Professionals

H o t Wa te r Syste m s. Tribune HE. Unvented Hot Water Cylinders. Making Life Simpler

High Output Boiler Systems

Instructions for Use Installation and Servicing

H o t Wa te r Syste m s. Ultrasteel. Unvented Hot Water Cylinders. Exceeding the Standard

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

ADVANCE ELECTRIC THERMAL STORE

Combined electric boiler and domestic hot water store

Electric PRODUCT.GUIDE. Electrical Water Heaters and Cylinders suitable for a comprehensive range of hot water requirements.

UNVENTED STAINLESS STEEL CYLINDERS

Instructions & Maintenance

Unvented Calorifier Range. Operating and Maintenance Manual. For Models & 500

Unvented Water Heating. Zircon

Technical and Installation manual All Models

SEALED THERMAL STORE

WATER HEATERS. Simplicity, performance, comfort... Hydraflo. Unvented Cylinders. 125 to 300 litres, directly or indirectly heated.

ADVANCE UNIVERSAL MULTI-FUEL THERMAL STORE

H ot Wa te r Syste m s. Copper Hot Water Products. Total Hot Water Solutions

THERMOSTATIC CONTROL TECHNOLOGY HORNE 40 AND 50 THERMOSTATIC MIXING SYSTEMS

Exceeding the Standard

Exceeding the Standard

Introduction. There is no obligation to follow the methods or comply with the standards set out in this Technical Booklet.

Cylinders & Water Heaters

Extreme Domestic Hot Water Loading System TECHNICAL DOCUMENTATION. Issue 11/09

Installation & Technical Guide. Domestic & Commercial.

Mains Pressure Hot Water from an existing vented copper cylinder... Allows the cold water tank to be removed, freeing loft space.

Cistern-fed water heating

Slide 1 Jul 20, 2006 Viessmann UK

water solar heating SOLAR

EFFICIENCY THERMAL STORAGE SYSTEMS

MAXIMISER Semi-Storage Calorifiers

H o t Wa te r Syste m s. Copper Hot Water Products. Exceeding the Standard

CPC-150-ABIAB. Important Installation Notes.

Hotflo. Unvented point of use hot water

Amptec. Electric flow boiler

Efficiency Maximiser for Solid Fuel Central Heating

Experienced. Flexible. Reliable. Approachable. Genuine

Copper-Fin GAS-FIRED WATER HEATERS

Transcription:

THERMAL STORE MAINS PRESSURE SYSTEM Hot Water Storage Solutions T: 015 1

Our THERMflow thermal store, works at the heart of your heating and hot water system to provide a high performance, mains pressure solution which delivers enormous benefits. Our thermal store approach can incorporate multiple energy sources to heat the home as well as meet hot water demand to achieve improved efficiencies and cost savings. And with our unique design and manufacture solution, we can offer significant cost savings both during installation and ongoing running costs. DISCOVER THE BENEFITS OF A ThermFLOW THERMAL STORE > No costly pumps and electronic controls required - providing piping hot water even during a power outage > Delivers mains pressure hot water with scald protection and inherent safety of vented system > Can incorporate multiple fuel sources > ALL energy inputs can be transferred to heating AND hot water circuits > Perfect partner for solid fuel with copper feed and epansion tanks > Fit and forget solution with no G certification required > Being copper provides complete peace of mind killing % of bacteria > Available in any shape and any size including like for like replacements WHY ThermFLOW Manufactured from premium grade copper, our THERMflow mains pressure hot water system delivers unrivalled performance thanks, in part, to copper s superior thermal transfer properties. One of our key advantages is the etra long finned copper coil which we incorporate into every THERMflow cylinder. This ensures greater flow rates, improves efficiency and reduces ongoing costs. This means our THERMflow thermal store cylinder is designed to achieve a consistently high water temperature due to a combination of our unique design and copper s increased efficiency. With a comprehensive range of thermal store solutions and the ability to have your cylinder any size, any shape and with any fuel sources, you can be assured of the optimum hot water storage solution T: 015 1

Multifuel Combination Type 15 The multi-fuel thermal store allows the incorporation of multiple heat sources into a single tank. Using your solid fuel appliance along with solar thermal, the system can be heated without the need for gas, oil or electric. Only at times where the other heat sources are unable to cope with demand, will the boiler come on to top up the temperature. 1 1 The combination type can be installed anywhere in the property, normally the top floor or attic. Providing the primary feed and epansion tank is at the highest level, the entire system can remain open vented. The minimum gap between highest radiator and base of header tank is 500mm. If this minimum distance can not be achieved then a sealed heating coil can be installed in the thermal store, alternatively select the Cylinder Type. See page. 7 5 1. Ballvalve & copper float. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. Solar Probe Pocket 1 1. Solar Coil. Immersion Heater. Thermostats 1. Temperature Gauge 1. Solid Fuel Flow 1. Solid Fuel Return 15. Boiler Flow 1. Boiler Return Incorporates multiple heat inputs Great all-in-one solution Connections positioned for optimum performance Solar thermal can contribute to hot water and space heating Maintenance Free Ball Valve & Copper Float mm DHW Coil & Miing Valve 1.m sq solar coil (larger coils are available) no. mm Solar Probe Pockets mm Flow & Return for Vented Boiler 1 mm Flow & Return for Solid Fuel mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted no. Thermostats Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 50+) 1. If sealed system boiler then coil required.. Etra immersions can be included. STORAGE CAPACITY 50 00 00 Model No. TFI1MF TFIMF TFIMF TFIMF TFI5MF TFIMF TFI7MF Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 1500 050 150 70 AVAILABLE INCLUDING SLIMLINE AND RECTANGULAR MODELS T: 015 1

1 Multi-fuel Cylinder Type 1 The multi-fuel thermal store allows the incorporation of multiple heat sources into a single tank. Using your solid fuel appliance along with solar thermal, the system can be heated without the need for gas, oil or electric. Only at times where the other heat sources are unable to cope with demand, will the boiler come on to top up the temperature. 1 The cylinder type can be installed anywhere in the property, and is linked with a separate copper feed and epansion tank which is normally located in an attic space. 7 5 1. Vent to Header Tank. Hot Draw Out (c/w TMV). Epansion Chamber 1 1 17 15. Solar Coil. Immersion Heater 1. Thermostat Incorporates multiple heat inputs Great all-in-one solution Connections positioned for optimum performance Solar thermal can contribute to hot water and space heating mm DHW Coil & Miing Valve 1.m sq solar coil (larger coils are available) no. mm Solar Probe Pockets mm Flow & Return for Vented Boiler 1 mm Flow & Return for Solid Fuel mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted no. Thermostats Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 50+). Cold Mains In (c/w Y Strainer). Central Heating Flow 1. Temperature Gauge 1. Solid Fuel Flow 15. Solid Fuel Return 1. Boiler Flow 1. If sealed system boiler then coil required.. Etra immersions can be included.. Use with our copper high temp header tank on page 1.. Feed from Header Tank 17. Boiler Return. Solar Probe Pocket STORAGE CAPACITY 50 00 00 Model No. TFIC1MF TFICMF TFICMF TFICMF TFIC5MF TFICMF TFIC7MF Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 170 170 170 70 AVAILABLE INCLUDING SLIMLINE MODELS T: 015 1

Open Vented Boiler Combination This thermal store simply accepts heat input from an open vented boiler to provide domestic hot water and central heating throughout the property. The combination tank is best installed on an upper floor or in a loft or attic space keeping the primary feed and epansion tank at the highest level, keeping the entire system open vented. If the gap between highest radiator and base of header tank is less than 500mm then you will require a sealed heating coil. An ideal alternative to a combi boiler, with the major benefit being high flow rate, mains pressure hot water with increased reliability and no annual service. No annual service Mains pressure hot water Immersion heater backup for entire system Epertly positioned connections for optimum performance 5 7 1. Ballvalve & Float. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow 1. Immersion Heater. Temperature Gauge. Thermostat. Boiler Flow 1. Boiler Return mm DHW Coil & TMV mm Flow & Return for Boiler mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted 1no. Thermostat Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) STORAGE CAPACITY 50 00 00 Model No. TFI1OV TFIOV TFIOV TFIOV TFI5OV TFIOV TFI7OV Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 1500 050 150 70 AVAILABLE INCLUDING SLIMLINE MODELS T: 015 1 5

1 Open Vented Boiler Cylinder This thermal store simply accepts heat input from an open vented boiler to provide domestic hot water and central heating throughout the property. The cylinder type can be installed almost anywhere in the property and requires a separate high temperature header tank installed at the highest point in the property, keeping the entire system open vented. An ideal alternative to a combi boiler, with the major benefit being high flow rate, mains pressure hot water with increased reliability and no annual service. No annual service Mains pressure hot water Immersion heater backup for entire system Epertly positioned connections for optimum performance 5 7 1 mm DHW Coil & TMV mm Flow & Return for Boiler mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted 1no. Thermostat Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) 1. Vent to Header Tank. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. Feed from Header Tank. Immersion Heater. Temperature Gauge. Thermostat 1. Boiler Flow 1. Boiler Return STORAGE CAPACITY 50 00 00 Model No. TFIC1OV TFICOV TFICOV TFICOV TFIC5OV TFICOV TFIC7OV Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 170 170 70 AVAILABLE INCLUDING SLIMLINE MODELS T: 015 1

Sealed System Boiler Combination This thermal store simply accepts heat input from a pressurised boiler to provide domestic hot water and central heating throughout the property. The combination tank is best installed on an upper floor or in a loft or attic space keeping the primary feed and epansion tank at the highest level, to keep the central heating system open vented. If the gap between highest radiator and base of header tank is less than 500mm then you will require a sealed heating coil. Alternatively have a look at our pressurised thermal store on page. No annual service Mains pressure hot water Immersion heater backup for entire system Epertly positioned connections for optimum performance 5 7 1 mm DHW Coil & TMV mm Flow & Return for Sealed Boiler Coil mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted 1no. Thermostat Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) 1. Ballvalve & Float. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. Immersion Heater. Temperature Gauge. Thermostat. Sealed Boiler Coil Flow 1. Sealed Boiler Coil Return STORAGE CAPACITY 50 00 00 Model No. TFI1SB TFISB TFISB TFISB TFI5SB TFISB TFI7SB Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 1500 050 150 70 AVAILABLE T: 015 1 7

Sealed System Boiler Cylinder This thermal store simply accepts heat input from a pressurised boiler to provide domestic hot water and central heating throughout the property. The cylinder type can be installed almost anywhere in the property and requires a separate high temperature header tank installed at the highest point in the property, keeping the entire system open vented. 1 Mains pressure hot water Immersion heater backup for entire system Epertly positioned connections for optimum performance 5 7 1 mm DHW Coil & TMV mm Flow & Return for Sealed Boiler Coil mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted 1no. Thermostat Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) 1. Auto Air Vent. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. Immersion Heater. Thermostat. Temperature Gauge. Boiler Flow 1. Boiler Return 1. Temperature & Pressure Relief Valve 1. Epansion Relief Valve 15. Tundish STORAGE CAPACITY 50 00 00 Model No. TFI1SB TFISB TFISB TFISB TFI5SB TFISB TFI7SB Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 150 70 AVAILABLE T: 015 1

Electric Combination This thermal store only provides hot water from a minimum of no kw immersion heaters, normally one using off-peak, cheaper, electricity while the other acts as a boost hours a day. The tank can be installed almost anywhere within the property, provided an overflow pipe can be safely routed away. Commonly used in apartments where an unvented cylinder cannot be installed due to strict G guidelines surrounding discharge pipework. 7 No annual service Mains pressure hot water Utilises off-peak electricity for reduced running costs Connections located centrally for ease of installation Boost and immersion 5 mm DHW Coil & TMV no. kw LWD Immersion Heaters Fitted Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) 1. Ballvalve & Float. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Immersion Heaters 7. Temperature Gauge STORAGE CAPACITY 50 00 00 Model No. TFD1 TFD TFD TFD TFD5 TFD TFD7 Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 1500 050 150 70 AVAILABLE INCLUDING RECTANGULAR MODELS T: 015 1

1 1 Pressurised Thermal Store This thermal store accepts heat input from a pressurised boiler, often a biomass boiler, to provide domestic hot water and central heating throughout the property. 15 It allows the store to be installed almost anywhere in the property and creates a fully pressurised system, which requires a suitably sized heating epansion vessel. Where a boiler is the only heat source, and locating a header tank is not an option this could be the ideal solution. Consideration must be taken for the relief valves that come factory fitted, and will operate the same as an unvented cylinder. Mains pressure hot water Immersion heater backup for entire system Epertly positioned connections for optimum performance 5 7 1. Connection for Auto Air Vent. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. System Feed 1. Immersion Heater. Thermostat. Temperature Gauge 1. Boiler Coil Flow 1. Boiler Coil Return 1. Temperature & Pressure Relief Valve 15. Epansion Relief Valve 1. Tundish Maimum Primary Working Pressure of.5 Bar Relief Valves & Tundish Factory Fitted mm DHW Coil & TMV mm Flow & Return for Boiler mm Flow & Return for Central Heating kw LWD Immersion Heater Fitted 1no. Thermostat Dial Thermometer 0mm Polyurethane Foam Lagging (70mm on 00+) STORAGE CAPACITY 50 00 00 Model No. TFIC1SS TFICSS TFICSS TFICSS TFIC5SS TFICSS TFIC7SS Bedrooms 1 - - - - 5 5 - Baths & Showers 1 1 5 5 Ma Heating Load (kw) 1 1 1 7 5 0 150 150 70 AVAILABLE T: 015 1

15 Rectangular Thermal Store Our thermal store range, ecluding the pressurised model, can also be supplied as a rectangular tank. 1 These units offer fantastic space saving solutions, typically providing the same capacity in up to 7% less space. Whilst we list a few typical eamples of sizes, our bespoke manufacturing ability enables us to manufacture any shape or size. ADDITIONAL OPTIONS Solar Coil Solid Fuel Connections Etra Immersions Available with steel frame to elevate tank 7 1 1 Ecellent space saving solution for tight spaces White cased as standard for superior quality finish The most customisable thermal store on the market 5 1. Ballvalve & Float. Hot Draw Out (c/w TMV). Epansion Chamber. Cold Mains In (c/w Y Strainer). Central Heating Flow. Immersion Heater. Thermostat. Temperature Gauge. Boiler Flow 1. Boiler Return 1. Solid Fuel Flow 1. Solid Fuel Return 15. Overflow STORAGE CAPACITY 150 50 00 Width mm 00 Depth mm 5 55 00 Height mm 15 15 15 OTHER CAPACITIES AND SIZES ARE AVAILABLE T: 015 1

Copper High Temperature Feed and Epansion Tanks 1 Our high temperature feed and epansion tanks are designed to be used with open vented thermal storage systems, especially when combined with additional fuel sources such as wood burning stoves, where high temperatures are prevalent. Manufactured from premium grade copper to withstand temperatures of over 0 C, our feed and epansion tanks can be manufactured to any shape and size to suit your requirements. 1. Ballvalve. Epansion from Cylinder / Overflow. Epansion from Cylinder / Overflow. Feed to Cylinder Can cope with temperatures over 0 C No chance of meltdown in an overheat situation Factory fitted insulation minimises dangers of freezing Proven to be healthy and safe Copper is 0% recyclable, benefiting the environment Maintenance free ball valve.5 float 5mm polyurethane foam lagging Alloy lid Additional Options Available: Different sizes to suit space restrictions Any capacity Compression Connections Connection sizes and positions adjusted to suit DIMENSIONS CAPACITY (LITRES) SIZE INCLUDING INSULATION STORAGE CAPACITY 0 0 50 0 70 0 Diameter mm 70 70 50 50 50 50 Height mm 75 70 500 50 50 T: 015 1 1

QUEENSWAY INDUSTRIAL ESTATE GLENROTHES FIFE KY7 5QF T: 015 1 F: 015 1 E: sales@mcdonaldwaterstorage.co.uk