R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

Similar documents
VALTRONICS IAQ Monitor

User's Guide. CO 2 Monitor. Model CO200

Model ST-128M Moisture Detector

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Model R9400. Instruction Manual. CO Meter with Temperature. wwwreedinstruments. com

WBGT Heat Stress Meter


Indoor Air Quality Meter Rev. 2.x Meters. The Value Leader TM

Manual Vane Anemometer PCE-VA 20

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

USER GUIDE Heat Index Psychrometer

CO2 RESPONDER Portable Carbon Dioxide Detector QUICK REFERENCE GUIDE

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

KANE-ALERT-CO 2 Monitor with Temperature

Carbon Monoxide Meter Model CO15. User Manual. Additional User Manual Translations available at

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

SGA71. Kane International Ltd Kane House Swallowfield Welwyn Garden City Hertfordshire AL7 1JG

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

ALTAIR 5X Multigas Detector Product Specification

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

GasAlertMicroClip X3 Specifications

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Introduction. OM-THA2

USER MANUAL Digital CO Monitor Model CO30

USER MANUAL ENVIRONMENTAL METER. Model EN510. Additional User Manual Translations available at

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

ToxiRAE II. PGM-1100 Series Personal Toxic Gas Monitor. User Manual

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Manual Hygrometer PCE-555

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

DI220 Using the Optional Docking Station The maintenance and operating functions of the Micro IV can be automated with the Micro IV Docking Station.

User Manual. Humidity-Temperature Chart Recorder. Model RH520

CALIBRATABLE 7-FUNCTION THERMO- HYGROMETER USER S MANUAL

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Bacharach Bodyguard 4 User's Guide

GasAlert. Introduction. WWarning. Table 1. GasAlert Models. Gas Monitored

Instruction Manual for FORMALDEHYDE GAS DETECTOR MODEL FP-30/FP-40

Toxic and Explosive Smart Gas Monitor PN / Installation and User Manual

Issue 4 10/10/11. Part Number: 48160

Pocket CO2 Monitor & Data Logger SAN-0001

Digital Salt / TDS Meter. 390a. The Value Leader TM

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Series Temperature Controller Instruction Sheet

Using the MiniRAE 2000 & ppbrae PID

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

USER GUIDE. Paperless Humidity/Temperature Chart Recorder. Model RH520A 21.2 C 13:

CO2 & Oxygen Monitor Operating Instructions Model: RAD

Model C-380. Instruction Manual. Refrigerant Leak Detector. reedinstruments

BST-MG08/09 Multi-gas Detecting Alarm. Manual Instruction

Operate the Mutli-Gas Monitor PID

Reference Manual. MultiVision Gas Detector

TOOLS AND INSTRUMENTS

Personal Single Gas Monitor. Activation Operation Troubleshooting

GMH 285 / GMH 285-BNC

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

HOBO U14 Data Logger User Manual

Dräger X-am 7000 Multi-Gas Detection

Smart Temp. Model

Carbon Monoxide Transmitter

Thermohygrometer with Single Type K Input and Superheat Function

EL-USB-1-LCD Temperature Data Logger with LCD

Specifications Minimum Typical Maximum Unit

Wöhler CM 220. Carbon Monoxide Meter. The Measure of Technology. Contents. 1. Important information Specification... 13

Wet Bulb Thermo-Hygrometer Datalogger

TDU Series LCD Thermostat For EFCB and EVCB Controllers. Models. Features. Functions. Onboard Sensors. Model # Temp RH CO2 Color.

ORDERING INFORMATION FEATURES EL-WIN-USB (CONTROL SOFTWARE) Maximum Speci cations Typical Minimum Unit

Using the QRAE Plus personal multigas monitor

Counting Scales. HC-i Series.

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Reference Manual. MultiPro Gas Detector

Infrared Moisture Balance (FD-660)

Refrigerator/Freezer Thermometer

ATX620. Instruction Manual. Multi-Gas Monitor. P/N REV 02 Printed Specifications Subject to Change GUARANTEED. FOR LIFE.

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

IMR IX176 Portable Gas Detector User Manual

Pioneer-R16 Gas Monitor Operator s Manual

User's Guide. Pinless Moisture Meter. Model MO257

data logger DL200H DL200D DL200L

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

Wireless Humidity/ Temperature Monitor Remote Wireless Sensor

ToxiPro. Single Gas Detector. Reference Manual

Refrigerator/Freezer Thermometer

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

Pressure measuring instruments

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Reference Manual MultiPro Gas Detector

EasyLog Data Logger Series

OPERATION MANUAL. THE JENCO MODEL 6230 MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

SENSIT HXG-2d Combustible Gas Detector INSTRUCTION MANUAL Read and understand Instructions before use. PENDING Ex. II3G Ex ic llb T3 IP20

II 2 G. SENSIT HXG-2d. Ex ib IIB T3 IP20. Suitable for combustible gases such as Methane, Butane, Propane and Natural Gas MADE IN USA

Microtherm Heat Stress WBGT

K100A Insertion Probe Thermometer

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Transcription:

Model R9900 Indoor Air Quality Meter Instruction Manual reedinstruments com

Table of Contents Features... 3 Specifications...3-4 Instrument Description...4-5 Operating Instructions...5-8 Data Hold... 5 Backlight... 5 Max, Min, & Weighted Averages... 6 Auto Power Off... 6 Alarm...6-7 Temperature Unit... 7 CO2 Calibration... 7 RH Calibration... 8 Software... 8 Troubleshooting... 9 Battery Replacement... 10 reedinstruments com 2

Features Simultaneously monitors carbon dioxide (CO 2 ), relative humidity and temperature Instantaneous readings are displayed on a high resolution LCD with backlight Dew point and wet bulb temperatures can also be displayed Displays STEL readings (Short-Term Exposure Limit) over a 15-minute period and TWA readings (Time-Weighted Average) over a period of 8 hours Hold function freezes displayed reading Maximum, minimum and average functions Low drift, non-dispersive infrared CO 2 sensor Audible warning alarm of excessive CO 2 concentrations RS232 output Specifications Ranges: Resolution: Accuracy: Sensors: Response Time: Audible Alarm: CO 2 : 0 to 5,000 ppm; Temperature: -10 to 60 C (14 to 140 F); Humidity: 0 to 99.9% RH; Dew Point: -73.4 to 60 C; Wet Bulb: -13.3 to 60 C CO 2 : 1 ppm; Temperature: 0.1 C/ F; Humidity: 0.1% RH CO 2 : ±5% rdg. ±50 ppm; Temperature: ±0.6 C (±0.9 F); Humidity: ±3% RH @ 25 C (10 to 90% RH) ±5% RH <10% & >90% CO 2 : Non-Dispersive Infrared (NDIR); Humidity: Rotronic capacitor 30 seconds 80dB continued... reedinstruments com 3

Power Supply: Battery Life: Includes: Optional accessories: 4 x AA alkaline batteries 24 hours 4 AA batteries and a hard carrying case 33% Calibration Salt (RHA-33) 75% calibration salt (RHA-75) Instrument Description Power/Set button Calibration/Escape button Hold button Up/Mode/Backlight button Down/Dew Point/WBT button Max/Min/Average/Enter button LCD Display 1. Air temp/dew Point/Wet Bulb temp in C or F 2. CO 2 concentration in ppm 3. Relative humidity % reedinstruments continued... com 4

TWA Time weighted average STEL Short-term exposure limit HOLD Readings are held on the LCD MIN/MAX Minimum/Maximum readings Low battery indicator DP Dew point temperature AIR Air temperature WBT Wet bulb temperature % Unit of relative humidity E (C or F) Celsius/Fahrenheit Operating Instructions 1. Press the POWER button to turn the meter on and off. When powering on, the meter will beep and commence a 30 second warm-up. The meter will then enter the normal-measuring mode, displaying the current CO 2, temperature, and humidity readings. Readings will be updated every second. Note: When the meter experiences extreme environment changes (ex. from high to low temp.), it will take 30 sec for the CO 2 sensor to respond and 30 minutes for the RH sensor. 2. Press the DP/WBT button to switch the temperature display from air temperature, dew point, and wet bulb. Data Hold To hold the readings that are currently being displayed on the LCD, press the HOLD button. The HOLD symbol on the LCD will indicate the function is activated. Backlight Hold down the BACKLIGHT button for a second to activate and to cancel the backlight function. reedinstruments com 5

Max, Min, & Weighted Averages While in the normal-measuring mode, press the MAX/MIN button to view the maximum, minimum, and weighted average readings. Each press of the MAX/MIN button will display the MIN, MAX, STEL (short term exposure limit), and TWA (time weighted average), in sequence and will then return to normal-measuring mode. In MIN and MAX modes, the LCD will show the minimum and maximum readings of CO2 on the main display and of the readings on the lower displays. In STEL and TWA modes, the main display will show the weighted average of CO2 readings for the past 15 minutes (STEL) or 8 hours (TWA). The lower displays will continue to measure normally. NOTE: If the meter is turned on for less than 15 minutes, the STEL value will be the weighted average of readings taken since power on. This is the same for TWA values before 8 hours of activity. It takes at least 5 minutes to calculate STEL and TWA. The display will show ---- during the first 5 minutes from power on. While all readings are held unchanged, STEL and TWA will keep updating every 5 minutes. Auto Power Off This meter turns off automatically after 20 minutes of inactivity. To override the function, turn the meter off and hold down the SET and HOLD buttons for 2 seconds to turn on the meter on. n will appear on the LCD if indicating Auto Power Off is deactivated. NOTE: the auto power off function will be disabled during calibration mode. Alarm This meter features an audible alarm when CO2 concentrations exceed a set limit. To set-up the alarm, press and hold the SET button for two seconds. AL and P1.0 will appear on the LCD. Press the ENTER button to modify the alarm setting. continued... reedinstruments com 6

The current alarm value will appear on the LCD. Press the UP and DOWN buttons to modify the ppm value by increments of 100. The alarm ranges from 100 to 9900ppm. When the desired alarm value is displayed, press the ENTER button to save, or press the ESC button to cancel. When measured CO 2 values are above the set limit the meter will start to beep. Press any button (except for the POWER button) to stop the beeping, or move the meter to a location where the ppm value is below the alarm limit. If the beeping does not stop, restart the meter. Temperature Unit To change the temperature scale from C to F, press and hold the SET button for 2 seconds. Press the DOWN button and Unit and P3.0 will appear on the LCD. Press the ENTER button, and modify the temperature unit by pressing the UP or DOWN buttons. Press the ENTER button to save the setting, or press the ESC button to cancel. CO 2 Calibration This meter is calibrated at a standard 400ppm CO 2 concentration. It s suggested to perform manual calibration regularly to maintain good accuracy. For a more thorough calibration and for maintenance for this product, please contact REED Instruments at info@reedinstruments.com. Do not calibrate this meter in an environment with unknown CO 2 concentrations. Manual calibration should be done in fresh outdoor air that is well ventilated and in sunny weather. Turn on the meter and hold down the CAL and MODE buttons simultaneously. 400ppm and CAL will blink on the LCD indicating you have activated manual calibration, and will blink for approximately 5 minutes. When the blinking stops, CO 2 calibration is complete, and the meter will automatically switch back to normalmeasuring mode. To abort the calibration, turn off the meter at any time. NOTE: Ensure the batteries are with full voltage during the calibration to prevent from interruption or failed calibration. reedinstruments com 7

RH Calibration The humidity sensor can be manually calibrated with the optional 33% and 75% salt solutions. It is recommended that the ambient condition to be at 25 C and at an stable humidity for the highest accuracy. To abort the calibration at any time, turn the meter off. Do not calibrate the humidity without the specified calibration salt otherwise it will cause permanent damage. Contact REED Instruments at info@reedinstruments for calibration salt or for service. Turn the meter on and plug the sensor probe into the 33% salt bottle. Hold down the CAL and DP/WBT button to initiate RH Calibration. CAL and the calibrating value of 33% (32.7% if at 25 C) will blink on the LCD along with the current temperature at the left. The meter is now calibrating and will finish when CAL and humidity stop blinking, which is about 60 minutes. After the 33% calibration is complete, plug the sensor probe into the 75% salt bottle. Press the ENTER button to initiate 75% calibration. CAL and the calibrating value of 75% (75.2% if at 25 C) will blink on the LCD along with the current temperature at the left. The meter is now calibrating and will finish when CAL and humidity stop blinking, which is about 60 minutes. To calibrate 33% only, press the ESC button when calibration is complete. To calibrate 75% only, press the UP or DOWN button after you press the CAL and DP/WBT buttons. Software This meter can link to a PC for logging and data analysis via the optional RS232 interface and software. The protocol is as follows: A. 9600 bps, 8 data bits, no parity. B. Cxxxxppm:Txxx.xC(F):Hxx.x%:dxxx.xC(F):wxxx.xC(F) LRC CRLF Description: $CO2:Air:RH:DP:WBT LRC CRLF reedinstruments com 8

Troubleshooting Won t power on Press and hold the POWER button for more than 1 second and try again. Check that the batteries are in good contact and correct polarity. Change the batteries if necessary. Fixed readings Check if the data hold function is activated. Slow response Check to see if the airflow channels on the rear are blocked. Error messages E01: CO 2 sensor damaged E02: The value is under range E03: The value is over range E04: The data error results in DP/WB readings E07: Too low voltage to measure CO 2 E11: Retry the humidity calibration E17: Retry CO 2 the calibration E31: Temperature sensor damaged E34: Humidity sensor damaged For service (repairs or calibration) on this or any other REED product or information on other REED products, contact REED Instruments at info@reedinstruments.com reedinstruments com 9

Battery Replacement The low battery symbol and Lob will appear on the LCD when the battery needs to be replaced. When the battery power is low, the meter will beep to indicate failed measurements. Press any button but the power button to turn off the beeping. Install the batteries in the battery compartment on the rear and make sure they are correct polarity and in good contact. Notes reedinstruments com 10