Horsham Boil Water Advisory. June 13, 2018

Similar documents
The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Telecom Decision CRTC

Reconciliation table Equipment (Public Safety) Regulations

Tyco Integrated Security Monitoring Services. Helping you secure your business 24 hours a day, 365 days a year. Safer. Smarter. Tyco.

Driving simplicity. Facility and security management in a single interface

Fire Protection Essentials QA/QC Plan Sample

Facility/Campus Lockdown Plan Elements

Product Guide. What is 5LINX Security Systems? Selling Security Systems: Ask the customer. Features and Benefits:

Pennsylvania Conservation Explorer Conservation Planning and PNDI Environmental Review. September 29, 2015 Greg Podniesinski Kent Taylor

FACILITIES PLANNED UTILITY OUTAGES POLICY

ELEVATOR RESCUE PROCEDURE

HazLoc Essential Guides:

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

Nova Scotia Fire Dispatch Minimum Standards (2017)

FROM: CITY MANAGER DEPARTMENT: POLICE FIRE SUMMARY OF REDWOOD CITY FIRE/COMMUNITY ALERTING SYSTEM (TELEMINDER) FAILURE

Access Controls for High Radiation Areas NISP-RP-05

Department of Emergency Management Policy #2 Emergency Notification and Alerting

Department of Emergency Management Policy #2 Emergency Notification and Alerting

Austin Independent School District Police Department Policy and Procedure Manual

Comprehensive solutions for greater safety and security Answers for infrastructure.

ESF 15: EMERGENCY PUBLIC INFORMATION

COLLABORATION & TECHNOLOGY TO IMPROVE ACTIVE SHOOTER RESPONSE

MNEC NFPA 72 WHITE PAPER

WATER DIVISION INSPECTION REPORT

Persona. Landlord. Happy Tenants means that I have less stress, less work to do and I can relax and spend more time on my motorbikes

Emergency. Management. Emergency. Readiness Checklist

Public Safety Orientation

One call protects it all.

Public Notice of Amendment to New Shoreham General Ordinances Chapter 5 Fire Prevention and Protection New Article IV Fire Alarm Ordinance

Connect your life to your home and your security

SECURITY SERVICE LEVEL AGREEMENT

The European Commission s science and knowledge service. Building on core components of Technical Reachback

ARTICLE 4-13 ALARM SYSTEMS * Division 1. Generally

Bring understanding to the roles and responsibilities What is the plan? Understanding of campus assembly points Discuss evacuation routes Answer any

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Presented at the ISPE ISA Automation Forum VP, Engineering Services

The Participant will select one of the two Approval Categories (below) and submit the appropriate documentation.

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

DIRECT CONNECT RESIDENTIAL ALARM SYSTEM Application Form

SUBJECT: Monitoring the performance of a sonic cleaners and/or automatic washers cleaning ability for lumens/cannulated items daily.

NZQA registered unit standard version 4 Page 1 of 5

/ / White Paper. Focusing on user experience

Siemens Enterprise Security. Integrated Security Process. Airports. & Resource Management for Today s Airports. Steve Batt, Market Manager Airports

Narrative Reports As Regulated by 780 CMR, Section 903.0

Electro-Sensors is revolutionizing the way hazard monitoring is done, with its turnkey HazardPRO TM systems. Rugged sensors and the most advanced

FAQs Radio Equipment Directive (RE-D)

API RP 1175 IMPLEMENTATION TEAM LOTTERY IF WE ALL PLAY, WE ALL WIN

Dennis Mullen System Operations Manager

DUQUESNE UNIVERSITY. Fire Protection System Impairment Program (Red etag Permit)

Facility Emergency Action Plans

Hazelwood Mine Fire Inquiry Actions Update. July 2015

HEALTH AND SAFETY FIRE SAFETY POLICY Putnoe Primary School

Contamination Control Campaign Workshop Introduction and Overview

AT A GLANCE... Our People, Culture & Place. A plan to sustain Ballarat s heritage (final draft)

4 ESF 4 Firefighting

City Council and Planning & Zoning Commission Workshop March 20, 2018

Achieve Success with European Medical Device Commercialization. By Russ King

MANUAL OF ENVIRONMENTAL HEALTH PROCEDURES

Shell Canada Limited Hydrogen Sulphide (H2S) Release September 12, 2006

UAF Police Department Emergency Communication Center USAGE AND SERVICE REPORT. December 31, 2011

Today s world has more risk than ever. Today s G4S has more ways to protect you.

Gulf Sulphur Services Ltd., LLLP. Hookers Point Terminal - Tank #8 Fires. LEPC November 20, 2013

Trinity River Authority of Texas

About IntraLogic. In Business since 2004 Over 55 Full time employees

DynAMo Alarm & Operations Management

Dangerous Assumptions

Dynamic Solutions. Endless Possibilities. Steve Padasack, Finch Paper LLC Rick Van Fleet, Honeywell

Neotronics portable gas detection. Portable protection from hazardous gas

Loss Prevention Standards

SN5446A, 47A, 48, SN54LS47, LS48, LS49 SN7446A, 47A, 48, SN74LS47, LS48, LS49 BCD-TO-SEVEN-SEGMENT DECODERS/DRIVERS

AUTROSAFE. An interactive fire detection system for larger vessels

Agincourt Mall Planning Framework Review Public Open House #2 Consultation Summary

FRANCHISE OPPORTUNITIES BRITISH COLUMBIA / LOWER MAINLAND

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

West Yorkshire Fire & Rescue Authority. Fire Protection Policy

OPTIMIZING YOUR TECHNOLOGY INVESTMENT WITH SERVICE AND SUPPORT

Service Business Plan

SECTION Free/Available Chlorine Analysis System

The evolution of level switches and detectors

Low Rise Residential occupancies are required to perform one fire safety training and one evacuation drill annually

VILLAGE OF MOUNT PROSPECT 2016 STREET RESURFACING PROGRAM Frequently Asked Questions (FAQ s)

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Warning and Notification Plan. Custer County Colorado

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Candidate APCO/CSAA ANS x: Alarm Monitoring Company to PSAP CAD External Alarm Interface Exchange

Moving Beyond Compliance: Campaigns & Corporate Strategies

WHAT HAPPENS NEXT FOR ADT SMART BUSINESS CUSTOMERS

Planned, Limited Notice and Emergency Outage Guidelines

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

It is with great pleasure that I present the Eaton County Central Dispatch (ECCD) 2017 annual report for your information and review.

CITY OF MOUNTAIN BROOK FIRE DEPARTMENT

Development and Use of Interdivisional Box Alarm Cards

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

Streets for People, Place-Making and Prosperity. #TOcompletestreets

Florham Park Police Department Community Satisfaction Survey (2016)

Risk Management Services

Fire System Impairment Policy

ALARM RESPONSE POLICY

PREMISES FIRE SAFETY LOGBOOK

Transcription:

Horsham Boil Water Advisory June 13, 2018

Boil Water Advisory 5/30/18-6/1/18 For the first time in our 30+ year history, we were required to issue an advisory to our water customers, recommending that they boil their water as a precaution prior to consuming it Water from Well 40 was pumped to the system without chlorine for approximately 8 hours 4 hours longer than allowed by DEP Numerous samples taken on consecutive days confirmed that there was no contamination of the public water system as a result of this event The advisory lasted two days because DEP regulations require two days of consecutive samples. Each sample requires 24 hours to incubate

How Our System Works

How Our Water System is Operated HWSA is the owner and Aqua Pennsylvania is the certified operator of the system Aqua Routine well operations Distribution system (main breaks, flushing, meter installs) Technical/customer services during & after hours Compliance monitoring 24-hour control system monitoring/emergency dispatch HWSA Implementation of near- and long-term maintenance/capital improvement plans SCADA and instrumentation maintenance and upgrades Meter reading Billing

What Makes Well 40 Unique? Well 40 includes permanent treatment for removal of PFOS/PFOA, making it a valuable source of supply under our Short-term Plan Well 40 is 1 of only 6 Authority-owned sources operational under the Short-term Plan Well 40 supplies our system with 10% of our water As we implement the Long-term Plan, we strive to keep in operation all wells with treatment systems, including Well 40

What Happened? The Authority had been experiencing operational difficulties with Well 40 for several weeks. These difficulties were not related to the quality of water being produced by the well Because of the desirable water quality, we continued to use Well 40 while addressing operational issues. This required manual control of the well, making it susceptible to human and control system failures that would not have occurred had the well been able to be shut down While in manual mode, the well and chlorinator were being shut down at night. While doing so, the operator s actions inadvertently shut down the chlorinator without shutting down the well pump An alarm was generated and acknowledged by Aqua, but an operator was not dispatched

Other Important Factors The failure occurred overnight when demand is low Due to low demand, tanks were filling so the majority of Well 40 water was mixing with chlorinated water from 6 other sources As part of the Short-term Plan all active wells are currently being operated at disinfection levels well above minimum requirements

System Safeguards Normally, multiple layers of operational control are in place to prevent a disinfection failure Control system synchronizes the operation of the well pump with the operation of the chlorine pump Control system shuts the well down when chlorine is low or not present A phone alarm is placed to the Aqua control center An operator is dispatched

What has HWSA done? Additional Safeguards Engaged outside consultant to lead a forensic analysis of the events and identify corrective actions Instituted redundant emergency call-out parameters Created additional ad hoc control system activity reports Reviewed regulatory reporting requirements and procedures with staff Submitted public notification certification to DEP

What has HWSA Done? Our Public Notification System This advisory was the first in our history, and it exposed weaknesses in our public notification system Verification that the well did in fact pump continuously > 4 hours without disinfection took time Process was complicated by the fact that the well was being operated manually The system is monitored and data is logged continuously, but technical support was required to access the data Data gaps from equipment and personnel increased the incident response time

Public Notification Improvements Outbound call system has been transitioned to new platform Numerous sources of resident contact information are being integrated Outreach to obtain customer contact information will be expanded HWSA Facebook, Twitter social media accounts have been established (to be launched this week)

What has Aqua done? Aqua s control center has added a separate log book specifically for Horsham in which: all alarms will be recorded, along with the action taken All HWSA alarms must be responded to with documented action (recorded in custom log book) HWSA must be notified of all alarms Developing a joint Aqua/HWSA team to clarify roles, responsibilities to improve communications

What Remains to Be Done? Resolve operational issues at Well 40 and return well to standard operational status Conduct third-party inspection & evaluation of control system Develop protocol/chain of custody for manual operation of wells Update & expand emergency response plan Establish provisions for Authority personnel to be informed of after-hours emergencies and available to answer customer calls as necessary

Looking Forward As a result of the inconvenience and disruption of the boil water advisory to our customers, the Authority will grant a 3-day credit to all impacted customers A comprehensive review of the events leading up to and throughout the recent advisory, including weaknesses in the notification and communication process, is actively in process We will explore every opportunity to improve the service we provide Every corrective action necessary will be taken to minimize the risk of a recurrence