Submittal Transmittal

Similar documents
VAV FAN POWERED TERMINAL UNITS TABLE OF CONTENTS FAN POWERED TERMINAL UNITS. C-2 Excellence in Air Distribution MODEL KQFS MODEL KQFP MODEL QFC

Lynergy Comfort Control SCR Electric Heater Application Guide

SINGLE DUCT TERMINAL UNITS

Chilled Water DOAS Fan Powered Terminal Units

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

Submittal Transmittal

Electric Coils. Blower Coils. Product Information

SECTION AIR COILS

FAN POWERED VAV TERMINALS

SECTION AIR DUCT ACCESSORIES

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Horizontal and Vertical DIRECT DRIVE BLOWER COIL UNITS. Rating and selection at

SECTION DUCTWORK

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION AIR COILS

FCI500/600/FVI500/FCL/FVL600/FCQ-700 Installation and Maintenance Manual

engineering guide FH Fan-Coil Units Low-Profile, Horizontal

FAN POWERED VAV TERMINALS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Modular Supply Make-Up Air Unit

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

Direct Fired Heater Model AD Specification

SECTION AIR HANDLING UNIT

Electric Duct Heaters. IDHB & IDHC Series

HEATER E L E CT R I C DUCT RENEWAIRE EVERYWHERE EVERY GEOGRAPHY, EVERY CLIMATE, EVERY HOME, EVERY BUILDING AND EVERY APPLICATION

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Custom Duct Heaters. Special Applications

Custom Duct Heaters. Special Applications

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER

catalog CDV Fan-Coil Units High-Performance, Vertical

Direct Gas-Fired Make-Up Air

SSL / SBS Sales Guide BLOWER-COILS REDUCED-FOOTPRINT, VERTICAL

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

SSL & SBS Engineering Guide

Modular Heating & Ventilating Unit Model IGX-HV

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION DUCTWORK

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

AIR DISTRIBUTION. C. Section Building Automation and Control System Guidelines. D. Section Fire Alarm System & Detection Systems

FEATURES AND BENEFITS

Installation and Maintenance Manual IM 1102

ADDENDUM No: 3 JOSEPHINE COUNTY BUILDING OPERATIONS DEPARTMENT. February 29, NO CHANGE: March 8, 2012 / NOT LATER THAN 2:00 PM

A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.

FCC Fan-Coil Units High-Performance, Vertical

.4 Section Ductwork Low Pressure Metallic to 500 Pa..3 ANSI/ARI 640 Commercial and Industrial Humidifiers.

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Duct Heaters volts/1 phase volts/3 phase volts/3 phases volts/3 phases. Flange Type Duct Heater.

PRODUCT CATALOG BLOWER COILS.

SECTION CONVECTION HEATING AND COOLING UNITS

ULTRA-SAFE Explosion-proof Duct Heaters

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

MANUAL INSTALLATION + SERVICE. Electric Coils. For VAV Terminals. v100 Issue Date: 01/09/ Price Industries Limited. All rights reserved.

ASHRAE JOURNAL ON REHEAT

INSTALLATION INSTRUCTIONS FOR FANLESS MAKE-UP AIR MODEL NER (USA)

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Installation and Maintenance Manual IM Single Duct VAV Terminals. Group: Controls Part Number: IM 1093 Date: February 2015

Standard Duct Heaters Open Coil

EHH SERIES DRAW THROUGH FAN COILS CFM

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Submittal Data Performance Data Electrical Data

INSTALLATION INSTRUCTIONS FOR MINI MAKE-UP AIR MODEL FER

ULTRA-SAFE Explosion-proof Duct Heaters

SECTION AIR HANDLING UNITS WITH COILS. 1. Central Station Air Handling Units. 1. Section Basic Mechanical Requirements.

Evolution Electric Heat Modulator CONTROLS INC. EVO/ EHM-S3

VIFB Coil Technical Guide

Gas-Fired Indoor and Outdoor Duct Furnaces

Warm. IFR Indirect Fired Gas Heating Systems. Applied Air. Keeps You

VH Series B ENVIRO-STAC Vertical Hi-Rise Fan Coil Unit with Enhanced Humidity Control

Bypass Terminal Units. DUCT VENTILATION AIR CONDITIONING Co. (W.L.L.) BYPASS TERMINAL UNITS

SECTION (15767) - UNIT HEATERS

Model 8120 and 8126 Safety & Installation Instructions

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

CxA to Answer this Section

Product Specifications. Vertical Floor Consoles By First Co.

SECTION ROTARY-SCREW WATER CHILLERS

SECTION FAN COIL UNITS

INSTALLATION, OPERATION & MAINTENANCE MANUAL ELECTRIC DUCT HEATER

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

CR1 Series Triton Corrosion Resistant Washdown Heaters

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

VIFB Coil Technical Guide

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

SECTION PACKAGED COMPRESSOR AND CONDENSER UNITS

Section (CSI ) I-Series Drum & Tube (04/23/10) Indirect-Fired Heating & Ventilating

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

DACC Health Sciences Building Air Handler Assessment/Study

Installation Instructions

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

BULLETIN. Temperature Controls (VAV) (3/11/2010)

READ AND SAVE THESE INSTALLATION INSTRUCTIONS

BULLETIN. Temperature Controls (10/2013)

Transcription:

Submittal Transmittal Standard St. Joe's - Sonntag Pavillion St. Joseph s Hospital 350 W. Thomas Road Phoenix, AZ 85013 Project # 5690A Tel: Fax: Kitchell Contractors Inc of AZ Date: 8/28/2011 Reference Number: 0087 To: Jarom Prows Comfort Systems USA SW 6875 W Galveston St Chandler, AZ 85226-2516 Tel: (480) 961-7241 Fax: (480) 961-7201 From: David Brown Kitchell Contractors Inc of AZ 1707 E Highland Ave, Suite 190 Phoenix, AZ 85016 Tel: (602) 222-5300 Fax: (602) 798-5750 Transmitted For Delivered Via Tracking Number Action Email Submittal Package No Qty Description Due Date Package Action 0001-23 36 00-0 1 Air Terminal Devices Closed Items Qty Description Item Action 1 1 Air Terminal Devices Closed Cc: Company Name Contact Name Copies Remarks Reviewed and approved as noted. Signature Signed Date Prolog Manager Printed on: 8/28/2011 KCI_Production_Standardized Page 1 of 1

AT-3 and AT-4 shall be size 6. 10822-00 X 0001-233600-0 Digitally signed b Digitally signed by David Bro y David Brown wn Date: Date: 2011.08.15 2011.08.15 21:40:02-0 7'00' 21:40:44-07'00' Brian Spotts ts 8/23/2011

6875 W. Galveston Street Chandler, AZ 85226 2516 480 940 8400 Fax 480 961 7200 KITCHELL CONTRACTORS Sonntag Pavilions - St. Joes Job No: 5690A Comfort Systems USA - Southwest Job No: 760009 Submittal Tab B VAV Boxes List of Manufacturers Krueger Submittal Review RFI Project #: 5690A #### Submittal #: 0001-233600-1 Date: 08/15/2011 8:56:55 PM Submittal Name : Air Terminal Devices X Reviewed and Approved Resubmitted as Noted Not in Compliance with Drawings and Specifications These documents have been reviewed and approved for general conformance with the Contract Documents. The approval is not to be construed as direction from the Contractor to the Subcontractor to deviate from the requirements of the Contract Documents. By : Dave Brown Supplier Climatec 2851 W Kathleen Rd. Phoenix, AZ 85053 (602) 944-3330 Main Contact Chris Carlson

VAV TERMINAL UNIT SUBMITTAL DATA PROJECT: Sonntag Pavilion @ St Joseph's Hospital & Medical Center LOCATION: ENGINEER: CONTRACTOR: SUBMITTED BY: MANUFACTURER: PRODUCT: TAG: Phoenix, Arizona AEI Comfort Systems USA Southwest Climatec, Inc. 2851 W. Kathleen Road Phoenix, AZ 85053 602-944-3330 Krueger LMHS AT-1,2,3,4 Submittal Date: 7/29/2011 Plan Date: 4/8/2011 Specification Section: 233600 Sales Engineer: Bryan Nelson Prepared by: Sandy Shugart

Material List Project: Equipment: Manufacturer: Tags: Sonntag Pavilion @ St Joseph's LMHS Krueger AT-1,2,3,4 MARK: AT-1~4 (4) Krueger VAV Terminal Unit(s), complete with: Single Duct Flow Sensor DDC Controls furnished and mounted in the field by others Std. 1/2" Liner Electric Heater Including Disconnect Switch Airflow Switch Contactors NOTE: 460 Volt 3 Phase Electric Reheat is 4 Wire. No External Vibration Isolation Provided ONLY THOSE ITEMS AND ACCESSORIES SPECIFICALLY LISTED ARE INCLUDED IN SCOPE EXCLUSIONS: All manual volume dampers, spin-ins, extractors, plenums and square to rounds of any kind unless noted otherwise. No filter media.

JOB NAME Sonntag Pavilion @ St Joe's Hospital ARCHITECT ENGINEER AEI CONTRACTOR Comfort Systems USA Southwest LOCATION AT-1 ~ AT-4 SUBMITTAL SHEET Form TS0013-EC.2 Effective Date 12/05 Replaces Form TS0013-EC.1 LMHS ELECTRIC HEAT UNIT ELECTRONIC CONTROL C TYP W AIR FLOW SENSOR 6 1/4 (159) TYP OPTIONAL FOUR QUADRANT FLOW SENSOR DAMPER (2 PLCS) H 12 (305) TYP 18 (457) 16 (406) 10 1/4 (260) INLET VIEW SIZES 4-16 DAMPER A D CHARTED 'A' DIMENSION INCLUDES INLET ADAPTER PROVIDED ON SIZES 4 & 5 39 1/2 (1003) 1/2 (13) INLET VIEW SIZE 22 4 1/4 (108) 24 (610) 38 (965) 39 1/2 (1003) 6 1/4 (159) TYP C 1/2 (13) INLET DISCHARGE INLET DISCHARGE AIR FLOW SLIP & DRIVE OUTLET DUCT CONNECTION AIR FLOW AIR FLOW ELECTRONIC DAMPER & REHEAT CONTROL ENCLOSURES AIR FLOW ELECTRONIC DAMPER & REHEAT CONTROL ENCLOSURES 36 5/8 (930) B PROVIDE 36" MINIMUM ACCESS PER NEC REQUIREMENTS SLIP & DRIVE OUTLET DUCT CONNECTION TOP VIEW SIZES 4-16 TOP VIEW SIZE 22 6 3/16 (157) 32 5/8 (829) PROVIDE 36" MINIMUM ACCESS PER NEC REQUIREMENTS STANDARD FEATURES: 22 Ga. Zinc coated steel construction. 1/2 thick dual density fiberglass insulation meeting NFPA 90A and UL 181 safety requirements. Linear averaging sensor. Variety of analog and digital electronic control packages for pressure independent systems. ETL listed Adherence to UL 429 for electrically operated valves ETL listed electric heater Electronic damper & reheat controls enclosure. Magnetic contactors are standard step controllers when electronic control systems are specified. Automatic reset thermal cutout Manual reset thermal cutout Positive pressure air flow switch OPTIONAL FEATURES: 20 Ga. Zinc coated steel construction Liners: None Double-Wall Cellular Steriliner Sterilwall Perf double wall 1 dual density fiberglass insulation Right hand control & electric heat. Left hand control & electric heat. Four quadrant averaging cross flow sensor. Hanger Brackets LineaHeat controlled SSR heat (no mercury contactor option) Discharge temperature sensor. Heater voltages: 120v/1Ø 240v/1Ø 208v/3Ø/3-wire 208v/1Ø 277v/1Ø 480v/3Ø/4-wire Mercury contactors Dust tight construction Heater disconnect switch Heater fused disconnect switch Fuse block w/ fuses for primary overload protection INLET NOM MAX SIZE CFM (L/s) W H A B C D NOTE : 4 230 (109) 12 (305) 8 (203) 5 3/8 (136) 5 1/2 (140) 2 (51) 3 7/8 (98) RIGHT HAND 5 360 (170) 12 (305) 8 (203) 5 3/8 (136) 5 1/2 (140) 2 (51) 4 7/8 (124) CONFIGURATION 6 520 (245) 12 (305) 8 (203) 3 3/8 (86) 5 1/2 (140) 2 (51) 5 7/8 (149) SHOWN ABOVE. 7 710 (335) 12 (305) 10 (254) 3 3/8 (86) 5 1/2 (140) 1 (25) 6 7/8 (175) LEFT HAND IS 8 925 (437) 12 (305) 10 (254) 3 3/8 (86) 5 1/2 (140) 1 (25) 7 7/8 (200) AVAILABLE 9 1200 (566) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 1/2 (89) - 8 7/8 (225) 10 1450 (685) 14 (356) 12 1/2 (318) 3 3/8 (86) 3 1/2 (89) - 9 7/8 (251) DIMENSIONS ARE 12 2100 (991) 16 (406) 15 (381) 3 3/8 (86) 3 1/2 (89) - 11 7/8 (302) GIVEN AS 14 2900 (1369) 20 (508) 17 1/2 (445) 3 3/8 (86) 1 1/2 (38) - 13 7/8 (352) INCHES (MM) 16 3700 (1746) 24 (610) 18 (457) 3 3/8 (86) 1 1/2 (38) - 15 7/8 (403) 22 7100 (3351) 38 (965) 18 (457) SEE ABOVE - 1 1/8 (29) SEE ABOVE Product Information is Subject to Change Without Notice

SUBMITTAL SHEET Form Number TSLX4.0 Effective Date 09/04 LINEAHEAT CODE LX4 2-10 Volt X designates input power code Proportional Electric Heat Controlled by Analog 2-10 dcv (4-20 ma) Output (Discharge Temperature Sensor Optional) LX4 Provides proportional electric heat from 0 to 100% for those controllers that have 2-10 dcv (4-20 ma) available for supplemental heat control. Heater output is directly proportional to dc Volt signal over 2 dcv. For example, 4 dcv (6 ma) provides 25% (2dcV/ 8dcVs * 100%) of the heater s kw rating. For inputs below 2 dcv (4 ma), heater will stay off. If LineaHeat is used with optional discharge temperature sensor, the heater is set to modulate heat to a set discharge temperature. User defined maximum temperature and controller defined temperature desired are maintained independent of heater kw or incoming air temperature. The maximum discharge temperature produced by the heater is set by rotary dial on the LineaHeat control board. When the unit receives a signal to start heating, % HEATER CAPACITY 100 80 60 40 20 0 0 2V (4 ma) the board will take an initial temperature reading and modulate heat from that point to the maximum temperature. For example, if a thermostat requires only a 10% increase in heating of air that was initially 60 F, and has a maximum temperature setting of 90 F, the EHM will modulate the heater s output temperature to 63 F (the additional 3 degrees coming from (90-60 )*10%). This option allows an increase of heater energy into occupancy by increasing discharge airflow while keeping an optimal discharge temperature. ASHRAE Fundamentals Handbook (Chapter 31) states that discharging air at a temperature more than 15 F above the room (90 F in a 75 F room) will likely result in significant unwanted air temperature stratification. 4V (8 ma) ANALOG OUTPUT 6V (12 ma) 8V (16 ma) 10V (20 ma) Product Information is Subject to Change Without Notice

SUBMITTAL SHEET Form Number TSLXY.0 Effective Date 09/04 LINEAHEAT PROPORTIONAL HEATERS With Optional Discharge Temperature Sensor LineaHeat is an electronic, time proportional electric heat system utilizing quiet, rapid performing solid-state relays. The solid-state relays are switched off and on by the LineaHeat Electric Heat Module (EHM) dependent on the call for heat from the controls. The LineaHeat EHM accepts a variety of different input signals from terminal unit controllers or thermostats, which can be determined by the position of one or two jumpers easily accessible on the board. Specific LineaHeat Submittals are available for each application that details the function and wiring of the board. LineaHeat is available with an optional discharge temperature sensor that will modulate the discharge temperature between the maximum temperature setting and initial temperature of incoming air before heating began. The discharge temperature set point is easily set in the field by rotating the temperature dial on the EHM. The EHM will not allow temperatures over the set point to insure meeting of ASHRAE 62, Addenda N, preventing unwanted temperature stratification and direct heat loss through return ductwork. On/Off (LX1) One 24 Vac input at Inc steps the heater output from OFF to 100% heater kw rating. The signal may be pulsed off and on over a small time period to provide proportional heat. 2 Stage (LX2) Two 24 Vac inputs step the heater output from OFF to 50% or 100% heater kw rating. 0-10V (LX3) 0-10 Vdc (0-20mA) signal proportionally modulates the heater output. 2-10V (LX4) 2-10 Vdc (4-20 ma) signal proportionally modulates the heater output. Incremental (LX5) One 24 Vac input modulates heater output, mirroring a Normally Closed water valve s action. An increase signal will increase the heater output from 0% to 100% over a 4 minute 15 second interval. When the signal is removed, the heater output will decrease to 0% over the same time period. Binary (LX6) Two 24 Vac inputs step the heater from OFF to 33%, 67%, or 100% of the heater kw rating. 3 Point Floating (LX7) Two 24 Vac inputs increase or decrease heater output, mirroring a Three-Point floating hot water valve. When the increase signal is sent, the heater will increase from 0% to 100% over a 4 minute 15 second interval. If the increase signal is removed, or the decrease signal is also added, the heater will stay constant at the present point. When only the decrease signal is sent, the heater will decline from the present level to 0% over the same time period. 24 Vac Neutral Signal Com Dec icom Inc } } 24VAC POWER FOR CONTROLS 0-10 dcv INPUTS } FROM CONTROLS OPTIONAL DISCHARGE } TEMPERATURE SENSOR 24 VAC INPUTS FROM CONTROLS Inc icom Dec Com Signal Neutral 24Vac (24Vac) (24Vac) 10Vmax Aux Inc icom Dec Sensor Com Signal Neutral 24Vac Com 49 C 120 F Tcal 32 C 90 F High Limit Earth 20 C 68 F EVO/EHM- 24Vac Neutral Xfmr 24Vac Neutral + Relay - SSRs + Relay - 0-10V 2-10V Float 2Stg Incr On/Off Bin Select Sequence> 24 VAC POWER FROM HEATER TRANSFORMER{ PROPORTIONALLY PULSED dc SIGNAL TO SOLID STATE RELAYS { 24 Vac Neutral Relay + Relay - JUMPER PINS DESIGNATE CONTROL SEQUENCE Product Information is Subject to Change Without Notice

JOB NAME Sonntag Pavilion @ St Joe's Hospital ARCHITECT ENGINEER AEI CONTRACTOR Comfort Systems USA Southwest LOCATION AT-1 ~ AT-4 SUBMITTAL SHEET Form Number TUIN00.0 Effective Date 8/04 ½ Dual Density (Standard) Insulation Submittal Physical Properties Material Dual Density Fiberglass Thickness 1/2 inch R-Value 1.9 Density 1.5 lbs / ft 3 with 4.0 lbs / ft 3 Face Maximum Operating Temperature 250 F / (121 C) Flame Spread Less than 25 Smoke Density Less than 50 Mold Growth and Humidity None Edge Treatment Sealant (NFPA 90A Approved) Code Compliances UL 181 Air Erosion UL 181 Mold Growth and Humidity UL 723 Flame / Smoke Spread (25/ 50) NFPA 255 Flame / Smoke Spread (25/ 50) NFPA 90A & 90B Appliances ASTM E 84 Flame / Smoke Spread (25/50) ASTM C 1071 Fiberglass Duct Liner

VAV SINGLE DUCT TERMINAL UNITS LMHS LMHS SUGGESTED SPECIFICATION & CONFIGURATION KRUEGER 2006 LMHS UNIT Furnish and install Krueger model LMHS single duct (variable or constant) terminal units of the sizes shown in the plans. Terminals shall be certifi ed by use of the ARI Standard 880-98 Certifi cation Program and carry the ARI seal. Unit casing shall be constructed of not less than 22 gage galvanized steel. (Optional) Unit casing shall be constructed of not less than 20 gage galvanized steel. All round air inlet collars shall accommodate standard fl ex duct sizes. Unit discharge shall be slip and drive construction for fi eld attachment to downstream ductwork. Unit labels shall be adhered to each unit including model size, airfl ow (CFM), balancing chart, and tagged data. (OPTIONAL) SOUND ATTENUATOR The single duct terminal units shall be provided with a onepiece integral sound attenuator section. The sound attenuator section shall consist of a continuous extension of the standard galvanized coated steel casing. Separate slip and drive attached attenuator will not be accepted. The control air damper assembly shall be constructed of heavy gage galvanized steel with solid 1/2 shaft rotating in Delrin bearings. Damper shaft shall be marked on the end to indicate damper position. Damper blade shall incorporate a fl exible gasket for tight airfl ow shutoff and operate over a full 90 rotation. LMHS unit shall be equipped with a factory installed airfl ow sensing device. Provide a linear, multi-point, velocity averaging sensor with an amplifi ed signal. (Optional) Provide a K4 LineaCross, four quadrant, multipoint center averaging sensor with an amplifi ed signal. Provide balancing taps to allow for easy airfl ow verifi cation. The radiated and discharge attenuation factors for the specifi ed NC levels shall be based on either room absorption, plus an environmental adjustment factor or the attenuation factors from ARI Standard 885-98 Appendix E, which includes room absorption, environmental adjustment factor, duct insertion, end refl ection and duct branching. CASING LINERS Unit casing shall be lined with 1/2 thick, 1 1/2 lb. dual density fi berglass insulation that meets UL 181 and NFPA 90A. (Optional) 1 Thick Insulation: Unit casing shall be lined with 1 thick, 1 1/2 lb. dual density fi berglass insulation that meets UL 181 and NFPA 90A. (Optional) Cellular Insulation: Unit casing shall be lined with glued and riveted 3/8 thick, 1 1/2 lb. density, smooth surface, polyolefi n, closed-cell foam insulation for fi ber free application. Cellular insulation meets UL 181 and NFPA 90A and does not support mold or bacteria growth. Cellular insulation is enclosed between the unit casing and a non-perforated internal sheetmetal cover extending over the cellular unsulation, as well as covering the liner cut edges. (Optional) Steriliner Insulation: Unit casing shall be lined with 13/16 thick, 4 lb. density, rigid board insulation with nylon reinforced foil covering insulation fi bers that meets UL 181 and NFPA 90A. Liner shall be attached to unit casing by insulation adhesive and full-seam-length Z-strips to enclose and seal the insulation cut edges. (Optional) Sterilwall Insulation: Unit casing shall be lined with 1/2 or 1 thick, 1 1/2 lb. dual density fi berglass insulation, meeting UL 181 and NFPA 90A, enclosed between the unit casing and a non-perforated internal sheetmetal cover extending over the fi berglass insulation, as well as covering the liner cut edges. (Optional) Perforated Doublewall Insulation: Unit casing shall be lined with 1/2, 1 1/2 lb. dual density fi berglass insulation, meeting UL 181 and NFPA 90A, enclosed between the unit casing and a perforated internal sheetmetal cover extending over the fi berglass insulation, as well as covering the liner cut edges. (Optional) No Liner: Unit casing shall be equipped with no internal insulation liner. ELECTRIC HEATING COILS Electric coils shall be supplied by the terminal unit manufacturer and shall be ETL listed and designed to comply with UL Standard 1096. Construct coil casing with minimum of 20 gage galvanized steel. Elements shall be 80/20 Ni-Cr and supported by ceramic isolators. The integral control panel shall be housed in a NEMA 2 enclosure with access to all controls and safety devices. Electric coils shall contain a primary automatic and secondary manual reset thermal cutout and differential pressure airfl ow switch for proving of airfl ow. (Optional) Electric coils shall include fused or non-fused door interlocking disconnect switch, mercury contactors, fuseblock, dust tight enclosure construction, all mounted and/or wired within the control enclosure. (Optional) LineaHeat solid state electronic proportional control of electric heat shall meet the requirements of ASHRAE Standard 62, Addenda N. (Optional) LineaHeat solid state electronic controlled electric heater with control of the leaving air temperature limiting the unit discharge temperature to a set value. HOT WATER COILS Hot water coil casing shall be constructed with minimum 20 gage galvanized steel with slip and drive discharge for attachment to downstream ductwork. Coils shall be factory attached to the terminal unit. Fins shall be rippled and corrugated heavy gage aluminum, mechanically bonded to tubes. Tubes shall be copper with minimum wall thickness of 0.016 and with male solder header connections. Coils shall be leak tested to 400 psi. Number of coil rows and circuits shall be selected to provide performance as required by the plans. Coil performance data shall be based on tests run in accordance with ARI Standard 410. SINGLE DUCT TERMINAL UNITS L M HS www.krueger-hvac.com Excellence in Air Distribution B-29

VAV SINGLE DUCT TERMINAL UNITS LMHS LMHS SUGGESTED SPECIFICATION & CONFIGURATION ACCESS PANEL Access panel shall be in the unit casing for viewing of damper components and/or for upstream cleaning of the hot water coil fi ns. (Access panel not available with electric heat.) SINGLE DUCT TERMINAL UNITS 1. SERIES: (XXXX) LMHS - Single Duct Terminal Unit 2. SENSOR TYPE: (X) 1 - Linear Averaging (Standard) 3 - K4 LineaCross (Four Quadrant) 3. UNIT STYLE: (X) 0 - Standard LMHS 1 - LMHS with Attenuator 2 - LMHS with Multiple Outlets 3 - LMHS with Electric Heat 4 - LMHS with Water Heat and Multiple Outlets 5 - LMHS Exhaust Unit + 6 - LMHS Low Profi le 7 - LMHS Low Profi le with Attenuator 8 - LMHS Low Profi le with Electric Heat 4. LINER TYPE: (X) 0-1/2 Liner 4 - Sterilwall 1-1 Liner 5 - Cellular 2 - Steriliner A - Perforated Doublewall 3 - No Liner 5. UNIT CASING CONTROLS: (XX) 0L - Left-hand Side, 22 Gage 1L - Left-hand Side, 22 Gage & Access Panel * 2L - Left-hand Side, 20 Gage 3L - Left-hand Side, 20 Gage & Access Panel * 0R - Right-hand Side, 22 Gage 1R - Right-hand Side, 22 Gage & Access Panel * 2R - Right-hand Side, 20 Gage 3R - Right-hand Side, 20 Gage & Access Panel * 6. INLET CODE: (XX) 04-4 05-5 06-6 07-7 08-8 09-9 10-10 12-12 14-14 16-16 20-20 22-24 x16 7. CONTROL TYPE: (X) D - Digital Controls ** A - Analog Controls P - Pneumatic Controls 8. UNIT ACCESSORIES: (X) (X) (X) (X) 0 - None S - Hangers D - Disconnect for Controls *** E - Dust-tight Control Enclosure *** G - 24-24 Vac Transformer H - 120-24 Vac Transformer J - 208-24 Vac Transformer K - 240-24 Vac Transformer L - 277-24 Vac Transformer P - Cam Locks (for Liner Codes 1-5) Y - Cam Locks (for Liner Codes 4 & A) 9. WATER HEAT: (XXX) (ROWS/CONNECTION HAND) 000 - N/A / None W11-1-Row/Right W21-1-Row/Left W12-2-Row/Right W22-2-Row/Left W13-3-Row/Right W23-3-Row/Left W14-4-Row/Right W24-4-Row/Left 10. ELECTRIC HEAT: (XX) 00 - None E1-120V/1-Phase L1 - LineaHeat, 120V/1-Phase E2-208V/1-Phase L2 - LineaHeat, 208V/1-Phase E3-240V/1-Phase L3 - LineaHeat, 240V/1-Phase E4-277V/1-Phase L4 - LineaHeat, 277V/1-Phase E6-208V/3-P/4-W L6 - LineaHeat, 208V/3-P/4-W E9-480V/3-P/4-W L9 - LineaHeat, 480V/3-P/4-W 10A.ELECTRIC HEAT STEPS: (X) 0 - None, 1-1-Stage 2-2-Stage 3-3-Stage 11. HEAT COIL ACCESSORIES: (X) (X) (X) (X) 0 - None A - Mercury Contactors for Pneumatic Controls B - Mercury Contactors for Electronic Controls C - Fuse Block E - Chicago Code Construction G - Dust-tight Construction K - Door-interlocking Fused Disconnect Switch L - Door-interlocking Non-fused Disconnect Switch S - Discharge Temperature Sensor/Cable (For LineaHeat Control Only) L M HS (*) Access Panel is not available with Electric Heat. (**) Digital controls are supplied by others; mounted by Krueger. (***) Disconnect for Controls not available with electric heat. Dust-tight Control Enclosure not available with Pneumatic Ellanious Control Types. Transformer standard when ordering electric heat. ( ) Water coil vent and drain optional. (+) Exhaust unit not available with Hot Water or Electric Heat. SAMPLE CONFIGURATION: LMHS - 3-3 - 1-0L - 08 - D - S - 000 - E92 - K KRUEGER 2006 B-30 Excellence in Air Distribution www.krueger-hvac.com