NYC Department of Education Building Assessment Survey 2017-2018 Asset: PS 152 ANNEX -BROOKLYN, 1087 OCEAN AVENUE, New York, 11210 Inspection Id Inspection Type Time In Last Edited EE : Electrical 2018-03-20 12:16 PM 2018-03-23 5:24 PM Asset Data Type of Service Does Interactive Whiteboard (IWB) Exist? Water Penetration in Electrical Room? Have any Systems/Major Building Components been upgraded? DEDICATED INTERCOMS IN FIRE RESCUE AREAS Are there any Life Rescue Assistance Areas, Fire Rescue Areas, and/or Holding Rooms in your building? Answer Below Ground Yes No Yes Systems: Years: 2015 Systems: Years: 2010 Systems: Years: 2008 Systems: Years: 2007 Systems: Interior Security Lights, Partial Motor Starter Intercom System (Elevator) Grounding System, LAN, Telephone System, Exit Lights (Battery Pack), Exit/Emergency Light Partial Molded Case Circuit Breaker Panel Board Years: 2000, 2006, 2010 No Priority Priority Priority Exist Category Last Year? Description Component Affected Location Description Person(s) Notified Person(s) Title Status PhotoImage No condition recorded Inspection Electrical AUDITORIUM CAFETERIA Fixture - Fluorescent Fixture - HID Fixture - Incandescent PB/A&W Page 1 of 10
Building Assessment Survey 2017-2018 CAFETERIA Fixture - LED Local Sound System Projection System Theater System CLASSROOM/CORRIDOR/ADMINISTRATIVE SPACE Does a Chandelier exist? No Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED COMPUTER LAB GYMNASIUM KITCHEN Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED LIBRARY PB/A&W Page 2 of 10
LIBRARY Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED Raceway With Receptacles Projection System LOCKER ROOM MULTIPURPOSE ROOM SCIENCE DEMO ROOM SCIENCE LAB SCIENCE PREP ROOM SWIMMING POOL TOILET ROOM - STAFF Fixture - Fluorescent Fixture - HID Fixture - Incandescent Fixture - LED TOILET ROOM - STUDENT Fixture - Fluorescent Fixture - HID NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 3 of 10
Building Assessment Survey 2017-2018 TOILET ROOM - STUDENT Fixture - Incandescent Fixture - LED AUXILIARY SIGNAL/BELL SYSTEM Replacement Quantity 24,000 Replacement Uom DOOR PUSH BUTTON NOT OPERATIONAL Location/Instance Main Entrance Door Quantity 1 MAINTENANCE Urgency of Action PRIORITY 3 Photo1 EMERGENCY DC STANDBY BATTERY POWER EMERGENCY GENERATOR SET EMERGENCY LIGHT/EXIT LIGHT PANEL EMERGENCY LIGHTING Battery Pack Location/Instance Quantity 1 FIXTURE LENS MISSING Cafeteria INSTALL LENS Urgency of Action PRIORITY 5 Photo1 Non Battery Pack EXIT LIGHT Battery Pack Non Battery Pack EXIT/EMERGENCY LIGHT CITY FIRE ALARM SYSTEM FIRE ALARM SYSTEM Replacement Quantity 24,000 Replacement Uom Bell/Horn PB/A&W Page 4 of 10
Building Assessment Survey 2017-2018 FIRE ALARM SYSTEM Bell/Horn Strobe Manual Pull Station Fan Shutdown Control Duct Smoke Detector Area Smoke Detector CO Detector Heat Detector Elevator Recall Magnetic Door Holder/Contactor Fused Cutout Panel Fire Alarm Digital Communicator Main Panel Bell At Panel Fire Alarm Control Panel (Electronic) Fire Alarm Control Panel (Standard) Instance Room 012 Instance Instance Quantity 1 Instance Instance Manufacturer ACME Equipment N/A Capacity/Size Quantity 4 Capacity/Size UOM Circuits Source of Capacity/Size Inspector Estimate Installation Year 1955 Source of Installation Documented PANEL DIRECTION/DIAGRAM IS MISSING Quantity 24,000 MAINTENANCE Urgency of Action PRIORITY 2 Photo1 Location/Instance Room 012 Quantity 24,000 BEYOND USEFUL LIFE REPLACE Urgency of Action PRIORITY 1 PB/A&W Page 5 of 10
Building Assessment Survey 2017-2018 FIRE ALARM SYSTEM Main Panel Fire Alarm Control Panel (Standard) Photo1 Sub-Panel Remote Annunciator Sprinkler Flow/Air Pressure Switch Tamper Flow Switch/Chain GROUNDING SYSTEM INTERCOM SYSTEM Elevator Holding Area LAN Local Distribution Frame (I/LDF) Main Equipment Rack (MDF) LIGHTNING PROTECTION MOTOR CONTROL CENTER MOTOR STARTER/CONTACTOR PANEL BOARD Fused Disconnect Switch Type Fused Knife Switch Type Fused Toggle Switch Type Molded Case Circuit Breaker Type Location/Instance Quantity 1 PANEL BOARD DIRECTORY MISSING OR REQUIRES UPDATING Cafeteria MAINTENANCE Urgency of Action PRIORITY 2 Photo1 NO SPARE Location/Instance 2nd Floor Corridor - By Room 202 Quantity 1 REPLACE PANEL BOARD PB/A&W Page 6 of 10
Building Assessment Survey 2017-2018 PANEL BOARD Molded Case Circuit Breaker Type Urgency of Action PRIORITY 3 Photo1 PANEL BOARD BEYOND USEFUL LIFE Location/Instance Kitchen, Cafeteria, Corridor - By Rooms 102, 302 Quantity 4 REPLACE-UPGRADE Urgency of Action PRIORITY 1 Photo1 PUBLIC ADDRESS SYSTEM Replacement Quantity 24,000 Replacement Uom Instance Room 110 Instance Instance Quantity 1 Instance Model Bogen Installation Year 1980 Source of Installation Inspector Estimate CLOCK NOT OPERATIONAL Location/Instance Classrooms and Corridors Quantity 24,000 REPLACE Urgency of Action PRIORITY 3 Photo1 BEYOND USEFUL LIFE Location/Instance Room 012 Quantity 24,000 REPLACE Urgency of Action PRIORITY 1 Photo1 SECURITY IPDVS/CCTV System Intrusion Alarm System Replacement Quantity 24,000 Replacement Uom PB/A&W Page 7 of 10
Building Assessment Survey 2017-2018 SECURITY Intrusion Alarm System Central Control Panel Instance Room 110 Instance 5 - Poor Instance Quantity 1 Instance Model Magnum Alert 1008LK Installation Year 1988 Source of Installation Inspector Estimate PANEL NOT OPERATIONAL Quantity 24,000 REPLACE SYSTEM Urgency of Action PRIORITY 4 Purpose of Action LEVEL 3 Photo1 Infrared Sensor Panic Switch Remote Annunciator Siren/Strobe Ultrasonic Sensor - Security Replacement Quantity 8 Replacement Uom SERVICE SWITCH Instance Room 012 Instance Instance Quantity 1 Instance Instance Manufacturer Empire Switchboard Equipment N/A Capacity/Size Quantity 800 Capacity/Size UOM Amps Source of Capacity/Size Nameplate Installation Year 1955 Source of Installation Documented BEYOND USEFUL LIFE Location/Instance Room 012 Quantity 24,000 PB/A&W Page 8 of 10
Building Assessment Survey 2017-2018 SERVICE SWITCH REPLACE Urgency of Action PRIORITY 1 Photo1 SWITCHBOARD Number of Spares 2 Air Circuit Breaker Type Fused Disconnect Switch Type Instance Room 012 Instance Instance Quantity 1 Instance Instance Manufacturer Equipment Capacity/Size Quantity 800 Capacity/Size UOM Capacity/Size2 Quantity 2 Capacity/Size2 UOM Source of Capacity/Size Installation Year 1955 Source of Installation Quantity 1 Empire Switchboard N/A Amps Total Section(S) Service Switch Size Documented SWITCHBOARD DIRECTORY MISSING OR REQUIRES UPDATING MAINTENANCE Urgency of Action PRIORITY 2 Photo1 Location/Instance Room 012 Quantity 24,000 BEYOND USEFUL LIFE REPLACE Urgency of Action PRIORITY 1 Photo1 Fused Knife Switch Type Molded Case Circuit Breaker Type TELEPHONE SYSTEM PBX/Intercom Standard PB/A&W Page 9 of 10
TELEPHONE SYSTEM Standard TRANSFORMER TV SYSTEM NYC Department of Education Building Assessment Survey 2017-2018 PB/A&W Page 10 of 10